| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GXH-3010/3011BF |
| Instrument Type | Portable |
| Detection Target | Multi-component |
| Minimum Range | (0–50.0) × 10⁻⁶ CO, 0–0.500% CO₂ |
| Repeatability | ≤1% FS |
| Resolution | 0.1 × 10⁻⁶ CO |
| Response Time | CO: t₀–t₉₀ ≤45 s |
| CO₂ | t₀–t₉₀ ≤15 s |
| Zero Drift | ≤±2% FS/h |
| Span Drift | ≤±2% FS/3 h |
| Linearity Error | ≤±2% FS |
| Brand | Huayun |
|---|---|
| Model | GXH-3010D |
| Type | NDIR-based Fixed Gas Analyzer |
| Measurement Principle | Gas Filter Correlation (GFC) Infrared Spectroscopy |
| Measurands | CO, CO₂, Hydrocarbons (HC) |
| Range | 0–100% vol (user-selectable sub-ranges) |
| Repeatability | ≤1% FS |
| Warm-up Time | ≤30 min |
| Response Time (T90) | ≤10 s |
| Output | 4–20 mA analog + RS-232/RS-485 digital interface |
| Temperature Control | Internal thermostatic stabilization |
| Compliance | JJG 635–1999, GB/T 18204.24–2000 |
| Enclosure | Customizable compact chassis (standard or application-specific rackmount) |
| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GXH-3011N |
| Instrument Type | Online |
| Detection Target | Single-component |
| Minimum Range | CO (0–500) × 10⁻⁶ |
| Repeatability | ≤ ±1% FS |
| Resolution | ≤ ±1% FS |
| Response Time | t₀–t₉₀ ≤ 30 s (from sample gas entry) |
| Zero Drift | ≤ ±2% FS / 72 h |
| Span Drift | ≤ ±2% FS / 72 h |
| Linearity Error | ≤ ±2% FS |
| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GXH-3010H (with One-Touch Zero Calibration) |
| Instrument Type | Portable |
| Detection Target | Single-Component Gas |
| Measurement Range | 0–0.500% CO₂ (expandable to 0–1.000%) |
| Repeatability | ≤1% of Full Scale |
| Resolution | 0.001% |
| Response Time (t₀–t₉₀) | ≤15 s |
| Zero Drift | ≤±2% FS/h |
| Span Drift | ≤±2% FS/3 h |
| Linearity Error | ≤±2% FS |
| Sampling Method | Integrated Pump-Aspiration |
| Flow Rate | 0.5–1.0 L/min |
| Warm-up Time | ≤10 min |
| Operating Temperature | 10–45 °C |
| CO Interference | ≤±0.3% FS at 1250 mg/m³ CO |
| Power Supply | AC 220 V (±10%) or Rechargeable Li-ion Battery |
| Dimensions | 200 × 95 × 35 mm |
| Weight | ≤500 g |
| Compliance | GB/T 18204.2–2014, GBZ/T 300.37–2017, JJG 635–2011 |
| Brand | Huayun Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HY-3000 |
| Instrument Type | Online Fixed-Mount System |
| Target Analyte | Single-Component Gas |
| Measurement Range (Minimum) | 0–50 ppm |
| Repeatability | ≤1% F.S. |
| Resolution | 0.1 ppm |
| Response Time | ≤60 s |
| Zero Drift | ≤±5% F.S. |
| Span Drift | ≤±1% F.S. |
| Linearity Error | ≤±2% F.S. |
| Key | Origin: Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | LD-3C |
| Measurement Principle | Light Scattering (Laser Nephelometry) |
| Safety Rating | Non-explosion-proof |
| Range (Low) | 0.01–100 mg/m³ |
| Range (High) | 0.001–10 mg/m³ |
| Sensitivity (L) | 1 CPM = 0.01 mg/m³ |
| Sensitivity (H) | 1 CPM = 0.001 mg/m³ |
| Sampling Time Options | 0.1, 1, 2, 5, 10 min + manual mode |
| Accuracy | ±10% |
| Dimensions | 192 × 69 × 140 mm |
| Weight | 1.4 kg |
| Compliance | WS/T 206–2001, LD 98–1996, TB/T 2323–92 |
| Brand | Huayun Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GXH-3010/3011BF |
| Instrument Type | Portable |
| Detection Target | Multi-component (CO & CO₂) |
| Minimum Range | CO: 0–50 ppm |
| CO₂ | 0–0.500% |
| Repeatability | ≤1% F.S. |
| Resolution | CO: 0.1 ppm |
| CO₂ | 0.001% |
| Response Time | ≤15 s (CO₂), ≤45 s (CO) |
| Zero Drift | ≤±2% F.S./4 h |
| Span Drift | ≤±2% F.S./4 h |
| Linearity Error | ≤±2% F.S. |
| Operating Temperature Range | 10–45 °C |
| Flow Rate | 0.5–1.2 L/min |
| Data Storage Capacity | Up to 5000 records |
| Interface | USB with proprietary data transfer software |
| Power Supply | AC 220 V (±10%) or rechargeable internal battery |
| Dimensions | 270 × 230 × 90 mm |
| Weight | ≤3.5 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LD-5C |
| Price | ¥27,800 |
| Sampling Method | Real-time Laser Scattering with Optional Filter-Based Gravimetric Validation |
| Particle Size Selectivity | PM₁₀ / PM₅ / PM₂.₅ via Interchangeable Impactors |
| Concentration Range | LD-5C(L): 0.01–100 mg/m³ |
| LD-5C(H) | 0.001–10 mg/m³ |
| Detection Limit | LD-5C(L): 0.1 mg/m³ |
| LD-5C(H) | 0.001 mg/m³ |
| Display | Backlit LCD with Chinese Character Menu |
| Data Storage | 99 Cyclic Records |
| Sampling Duration | Configurable from 0.1 min to user-defined intervals (1–9999 s) |
| Communication Interfaces | RS232 Serial Port, Thermal Printer Output, 0–1 V Analog Output, Digital TTL-Level Output |
| Power Supply | Rechargeable Ni-MH Battery (8 h continuous operation), AC/DC Adapter Included |
| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | GXH-3010/3011AE |
| Instrument Type | Portable |
| Detection Target | Multi-component |
| Minimum Range | 0–50 ppm |
| Repeatability | ≤1% F.S. |
| Resolution | 0.1 ppm |
| Response Time | ≤30 s |
| Zero Drift | ≤±2% F.S./4 h |
| Span Drift | ≤±2% F.S./4 h |
| Linearity Error | ≤±2% F.S. |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Sampling Method | Built-in Pump-aspiration |
| Flow Rate | 0.5–1.2 L/min |
| Power Supply | AC 220 V (±10%) or Rechargeable Battery |
| Dimensions | 260 × 210 × 90 mm |
| Weight | ≤3.5 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 1027 |
| Sampling Method | Active (Pump-Driven) |
| Measurement Range | 0.1–999 pCi/L (3.7–37,000 Bq/m³) |
| Minimum Detectable Concentration | 0.1 pCi/L |
| Sensitivity | 2.5 counts per hour per pCi/L (cph/pCi/L) |
| Accuracy | ±25% or ±1 pCi/L (whichever is greater) |
| Display | 3-digit LCD |
| Power Supply | 220 VAC / 9 VDC adapter |
| Dimensions | 200 × 120 × 65 mm |
| Weight | 0.9 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HY-3000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Repeatability | <1% |
| Response Time | 30 s |
| Measured Gases | CO, CO₂, CH₄, O₂ |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ML-91 |
| Price | USD 950 (FOB Jiangsu) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | 66 % ±15 % RH |
| Atmospheric Pressure | 750 mmHg ±30 mmHg |
| Frequency Band | 3–33 cm (i.e., 0.9–10 GHz) |
| Power Density Range | 0.2 µW/cm² to 20 mW/cm² |
| Display | 3-digit LED, auto-ranging across 200 µW/cm² / 2 mW/cm² / 20 mW/cm² scales with LED range indicators |
| Alarm Threshold | Adjustable, default ≥5 mW/cm² |
| Calibration Field Accuracy | ±0.75 dB |
| Full-Scale Indication Error (at rated voltage) | ≤±1.5 % |
| Indicator Dimensions | 82 mm × 40 mm × 172 mm |
| Net Weight | 0.8 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 4160-2 |
| Price | USD 3,650 (FOB) |
| Principle | Electrochemical Sensor |
| Measurement Range | 0–19.99 ppm |
| Extended Low-Range Mode | 0–500 ppb |
| Resolution | 0.01 ppm |
| Accuracy | ±2% Rd ±0.01 ppm |
| Flow Rate | 1.0 L/min |
| Dimensions | 178 × 102 × 225 mm |
| Weight | 2.0 kg |
| Power | Rechargeable Li-ion battery with real-time voltage monitoring |
| Certification | China NIM Type Approval (Certificate No. 2021F012), Evaluated by Chinese Center for Disease Control and Prevention – Institute of Environmental Health and Related Product Safety |
| Brand | Huayun Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Type | Online Fixed-Mount Analyzer |
| Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Response Time | T₀–T₉₀ ≤ 15 s (from sample gas entry) |
| Repeatability | ≤ ±1% FS for CO, CO₂, CH₄ |
| Linearity Error | ≤ ±2% FS |
| Zero Drift | ≤ ±2% FS / 72 h |
| Span Drift | ≤ ±2% FS / 72 h |
| Measurement Ranges | CO (0–500) ppm, CO₂ (0–500) ppm, CH₄ (0–1000) ppm |
| Output Signal | 4–20 mA analog |
| Power Supply | 220 VAC ±10%, 50 Hz ±10% |
| Dimensions | 436 × 426 × 133 mm (L×W×H, excluding protrusions) |
| Weight | ≤10 kg |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Environmental Requirements | Non-corrosive atmosphere, airflow ≤0.5 m/s, vibration-free horizontal mounting |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | HY-3000 |
| Instrument Type | Online Continuous Emission Monitoring System (CEMS) |
| Target Gases | CO, CO₂, CH₄, O₂, SO₂, H₂ |
| Response Time | ≤30 s |
| Zero Drift | ±2% FS / 48 h |
| Span Drift | ±2% FS / 48 h |
| Linearity Error | ±2% FS |
| O₂ Range Options | 0–2% or 0–25% vol |
| H₂ Range Options | 0–5% or 0–100% vol |
| CO Range | 0–5000 ppm (expandable) |
| CO₂/CH₄/SO₂ Ranges | 0–500 ppm / 0–500 ppm / 0–2000 ppm (all expandable) |
| Origin | China |
|---|---|
| Manufacturer Type | Distributor |
| Model | HS6288B |
| Price | USD 1,390 (FOB) |
| Frequency Range | 31.5 Hz – 8 kHz |
| Sound Pressure Level Range | 35–130 dB(A), 40–130 dB (Linear) |
| Self-Noise | <20 dB(A) |
| Time Weighting | Fast (F), Slow (S), Max Hold |
| Measurement Functions | Leq, LAE, LN (L10/L50/L90), Lmin, Lmax, SD, Ld, Ln, Ldn |
| Measurement Durations | Manual trigger, 10 s, 1 min, 5 min, 10 min, 20 min, 1 h, 8 h, 24 h, and full-hour synchronized logging |
| Display | 54 × 42 mm LCD with analog bar graph, real-time time stamp, measurement mode indicator, and 1/1-octave center frequency readout |
| Interface | RS-232 serial port for PC connectivity and data export |
| Standard Accessories | HS6288B(D) main unit, 4784A thermal printer (with charger), mounting bracket, software CD, thermal paper roll, 18″ protective carrying case, windscreen, screwdriver |
| Optional Accessories | 5 m / 10 m extension cables, Class 1 acoustic calibrator (e.g., HS6020) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HD-2000 |
| Price | USD 1,240 (FOB) |
| Measurement Range | 0.01–100 µGy/h |
| Energy Threshold | 60 keV |
| Linearity (r vs. CPS) | ≥0.999 |
| Stability | ≤6% |
| Accuracy | ±20% |
| Sensitivity | ≥350 cps at 1 µGy/h |
| Power Consumption | ≤100 mW |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90% @ 40 °C |
| Weight | 6 kg |
| Dimensions | 35 × 20 × 25 cm |
| Brand | Huayun Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY-400 (New) |
| Price | USD 5,600 (FOB Beijing) |
| Temperature Control Accuracy | ±0.1 °C |
| Setpoint Range | –20 °C to +10 °C (factory default: 4 °C) |
| Dimensions (W×H×D) | 484 × 178 × 320 mm |
| Gas Path Material | PTFE-lined stainless steel |
| Cooling Method | Staged refrigeration + condensate aggregation |
| Mounting | Panel-mount (19″ rack compatible) |
| Liquid Level Alarm Output | Dry contact relay (NO/NC configurable) |
| Integrated Pump Mounting | Yes (for sampling pump & peristaltic drain pump) |
| Brand | Huayun Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GXH-3010F |
| Price | Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Standard Range | 0–5000 ppm or 0–10000 ppm CO₂ |
| Response Time | ≤10 s |
| Linearity | ≤±2% FS |
| Repeatability | ≤1% FS |
| Power Supply | AC 220 V / Internal Rechargeable Battery |
| Weight | ≤3 kg |
| Dimensions | 248 mm × 185 mm × 85 mm |
| Optional Accessories | RS232 Interface, Real-Time Data Acquisition & Processing Software |
| Customization Options | Alternate Ranges, Integrated Temperature Sensor, O₂ Sensor (for Controlled Atmosphere Storage), Leaf Chamber Integration (Agricultural CO₂ Monitoring), Soil Probe Integration (Soil Respiration Studies) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GXH-3010E |
| Instrument Type | Portable |
| Detection Target | Single-component (CO₂) |
| Measurement Range | 0–0.500% v/v (configurable to 0–1.000%) |
| Repeatability | ≤1.0% FS |
| Resolution | 0.001% v/v |
| Response Time (t₀–t₉₀) | ≤15 s |
| Zero Drift | ≤±2% FS/h |
| Span Drift | ≤±2% FS/3 h |
| Linearity Error | ≤±2% FS |
| CO Interference | ≤±0.3% FS at 1250 mg/m³ CO |
| Temperature Effect | ≤±2% FS/10°C (10–45°C) |
| Warm-up Time | ≤10 min |
| Sample Flow Rate | 0.5–1.0 L/min |
| Power Supply | AC 220 V ±10% or rechargeable Li-ion battery |
| Dimensions | 210 × 165 × 85 mm |
| Weight | ≤2.0 kg |
| Origin | China |
|---|---|
| Type | Portable |
| Measurement Range | 60–140 dB (re 10⁻⁶ m/s²) |
| Frequency Range | 1–80 Hz |
| Frequency Weightings | Whole-body vertical (VLz), whole-body horizontal (VLx-y), linear (VAL) |
| Dimensions (main unit) | 24 × 8.1 × 3.1 cm |
| Weight (main unit) | 0.4 kg |
| Data Storage Capacity | 127 measurement sets |
| Compliance | ISO 2631-1, ISO 5349-1, and IEC 61260 Class 2 requirements for vibration meters |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | IFC-2 |
| Price | USD 690 (FOB Beijing) |
| Flow Rate Range | 5–25 L/min (continuously adjustable) |
| Timer Range | 0–99 minutes |
| Power Supply | AC 220 V / DC rechargeable battery (≥3 h continuous operation) |
| Dimensions | 210 × 130 × 90 mm |
| Explosion Protection | Intrinsic Safety “ib I” per GB 3836.4–2021 / IEC 60079-11 |
| Brand | Huayun |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GXH-3010F |
| Instrument Type | Portable |
| Detection Target | Single-component gas |
| Measurement Range | 0–0.500% CO₂ (customizable up to 0–20.00%) |
| Repeatability | ≤1% FS |
| Resolution | 0.001% CO₂ |
| Response Time | t₀–t₉₀ ≤15 s |
| Zero Drift | ≤±2% FS/h |
| Span Drift | ≤±2% FS/3 h |
| Linearity Error | ≤±2% FS |
| Temperature Effect | ≤±2% FS/10°C (10–45°C) |
| CO Interference | ≤±0.3% FS at 1250 mg/m³ CO |
| Power Supply | AC 220 V (±10%) or internal rechargeable battery |
| Dimensions | 255 × 215 × 92 mm |
| Weight | ≤3.2 kg |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | P5-L2C |
| Price | ¥18,600 |
| Operating Principle | Light Scattering (Nephelometric) |
| Safety Rating | Non-Explosive |
| Measurement Range | 0.01–100 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Sampling Duration Options | 0.1, 1, 3, 5, 10, 15 min or user-defined manual interval |
| Display | 4-digit LCD showing CPM and mass concentration (mg/m³) simultaneously |
| Data Output | RS-232 serial interface for PC connection |
| Data Storage | 99 measurement records |
| Environmental Operating Range | 0–40 °C |
| Power Supply | NiMH ×9 rechargeable battery (12 h continuous operation) |
| Dimensions | 202 × 84 × 183 mm |
| Weight | 3.4 kg |