Empowering Scientific Discovery

Beijing Huayun Analytical Instrument Research Institute Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginChina
Manufacturer TypeDistributor
ModelHS6288B
PriceUSD 1,390 (FOB)
Frequency Range31.5 Hz – 8 kHz
Sound Pressure Level Range35–130 dB(A), 40–130 dB (Linear)
Self-Noise<20 dB(A)
Time WeightingFast (F), Slow (S), Max Hold
Measurement FunctionsLeq, LAE, LN (L10/L50/L90), Lmin, Lmax, SD, Ld, Ln, Ldn
Measurement DurationsManual trigger, 10 s, 1 min, 5 min, 10 min, 20 min, 1 h, 8 h, 24 h, and full-hour synchronized logging
Display54 × 42 mm LCD with analog bar graph, real-time time stamp, measurement mode indicator, and 1/1-octave center frequency readout
InterfaceRS-232 serial port for PC connectivity and data export
Standard AccessoriesHS6288B(D) main unit, 4784A thermal printer (with charger), mounting bracket, software CD, thermal paper roll, 18″ protective carrying case, windscreen, screwdriver
Optional Accessories5 m / 10 m extension cables, Class 1 acoustic calibrator (e.g., HS6020)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun Instruments
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelHY-400 (New)
PriceUSD 5,600 (FOB Beijing)
Temperature Control Accuracy±0.1 °C
Setpoint Range–20 °C to +10 °C (factory default: 4 °C)
Dimensions (W×H×D)484 × 178 × 320 mm
Gas Path MaterialPTFE-lined stainless steel
Cooling MethodStaged refrigeration + condensate aggregation
MountingPanel-mount (19″ rack compatible)
Liquid Level Alarm OutputDry contact relay (NO/NC configurable)
Integrated Pump MountingYes (for sampling pump & peristaltic drain pump)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginChina
TypePortable
Measurement Range60–140 dB (re 10⁻⁶ m/s²)
Frequency Range1–80 Hz
Frequency WeightingsWhole-body vertical (VLz), whole-body horizontal (VLx-y), linear (VAL)
Dimensions (main unit)24 × 8.1 × 3.1 cm
Weight (main unit)0.4 kg
Data Storage Capacity127 measurement sets
ComplianceISO 2631-1, ISO 5349-1, and IEC 61260 Class 2 requirements for vibration meters
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelN962A
Instrument TypeHot-Wire Anemometer
Resolution0.01 m/s
Accuracy≤ ±5%
Operating Temperature0–40 °C
Operating Relative Humidity0–85% RH
Measurement Range0–30 m/s (auto-ranging across 0–10 / 0–20 / 0–30 m/s)
Power SupplyRechargeable Ni-MH Battery (memory-free)
DisplayLarge-format LED
Sensor ElementThin-film Platinum RTD (ceramic substrate)
ComplianceDesigned for GLP-aligned field use in occupational & environmental monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun Instruments
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelHY-400
PriceUSD 5,600 (FOB Beijing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun Instruments
OriginBeijing, China
Manufacturer TypeOEM Manufacturer
Region CategoryDomestic (China)
ModelHY-4000
PriceUSD 4,200 (FOB Beijing)
Gas Mixing Ratio Range0.1–99.9% of source gas
Output Flow Rate600 mL/min
Mixing Accuracy±1%
Linearity Error±1%
Repeatability±1%
Response Time≤5 s
Output Pressure34 kPa
Operating Temperature0–50 °C
Dimensions240 × 300 × 120 mm
Weight1.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayun Instruments
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelGXH-3011 (4U)
Measurement PrincipleNon-Dispersive Infrared (NDIR)
Target GasesNO, CO, CO₂, O₂ (configurable per unit)
Measurement RangesNO: (0–500) to (0–5000) ppm
CO0–0.500% vol
CO₂0–0.500% vol
Linearity Error≤ ±2% F.S.
Repeatability≤ 1% F.S.
Zero Drift≤ ±2% F.S. / 72 h
Span Drift≤ ±2% F.S. / 72 h
Response Time (t₀–t₉₀)≤ 15 s
Output Signal4–20 mA (max 3 isolated channels, load ≤ 500 Ω)
Power Consumption≤ 120 W
Supply Voltage220 VAC ±10%, 50 Hz ±10%
Enclosure19″ 4U rack-mount chassis (360 mm H × 482.6 mm W × 300 mm D)
Weight≤ 10 kg
Operating Temperature5–45 °C (non-condensing, no direct sunlight)
Relative Humidity≤ 80% RH
Ambient Airflow≤ 0.5 m/s
InstallationHorizontal mounting only
Electrical IsolationDedicated circuit recommended—avoid shared supply with inductive loads (e.g., large motors, RF furnaces)