| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AMI-300HP High-Pressure Chemisorption Analyzer (100 bar) |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable up to 12 |
| Heating Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar / 100 bar (dual-range configuration) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 TPD/TPO/TPR Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BenchCAT Custom Catalyst Evaluation System |
| Reaction Pressure | 300 bar |
| Reaction Temperature | 1200 °C |
| Catalyst Loading Capacity | mL- to L-scale configurable |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300Neo Basic Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Ramp Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Model | AMI-Master 400 Quadrupole Mass Spectrometer |
| Configuration | Benchtop Process Mass Spectrometry System |
| Ion Source | Electron Impact (EI), 70 eV standard |
| Mass Range | 1–300 amu |
| Detection Modes | Faraday Cup & Electron Multiplier (dual-mode) |
| Scan Speed | <10 ms per decade |
| Response Time | <100 ms (full-spectrum acquisition) |
| Operating Pressure (Ion Source) | 1×10⁻⁶ to 5×10⁻⁵ Torr |
| Vacuum System | Turbo-molecular pump (200 L/s) + Oil-free diaphragm backing pump |
| Inlet Temperature Control | Ambient to 200 °C (capillary + filter assembly, independently regulated) |
| Chamber Bake-out Capability | Up to 200 °C |
| Software Platform | Windows 7/10-compatible multi-channel gas analysis suite with real-time quantitation, spectral library matching, and audit-trail-enabled data logging |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated High-Sensitivity TCD (dual-filament or quad-filament, W or Au/W), MS/GC/FTIR/FID compatibility |
| Sample Capacity | 0.1–1.0 g |
| Sample Tube Types | Quartz U-tube, bubble tube, straight-wall tube (low-pressure) |
| Tubing | 1/16″ OD 316 SS, heated throughout |
| Gas Mixing | Internal precision gas mixer (no external mixer required) |
| Cooling | Automated air-cooling module |
| Safety Systems | Dual-zone temperature monitoring, over-temperature cutoff, TCD flow interlock, front-panel emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace & bed), GLP-compliant data audit trail, FDA 21 CFR Part 11-ready configuration options |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Jingwei Gaobo Instrument Co., Ltd. |
| Reactor Type | Fixed-Bed Microreactor |
| Configuration | 8 Parallel Stations |
| Pressure Rating | High-Pressure (up to 100 bar typical for catalytic evaluation) |
| Volume Class | Small-Scale (individual reactor volume: 0.1–5 mL) |
| Application Focus | Catalytic Activity Screening, Kinetic Studies, Stability Testing, and Process Development |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AMI-400 Automated Chemisorption Analyzer |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Model | AMI-Master400 |
| Vacuum System | Turbo-molecular pump + oil-free diaphragm dry pump with full-range vacuum gauge |
| Inlet System | Heated stainless-steel or quartz capillary (ambient–200 °C), dual-stage pressure reduction |
| Mass Analyzer | Quadrupole mass filter with electron impact (EI) ion source |
| Detectors | Dual-mode detection — Faraday cup and electron multiplier |
| Detection Range | 100% to sub-ppb (v/v) |
| Response Time | <100 ms |
| Scan Speed | Millisecond-scale mass scanning |
| Mass Range | 1–300 u (standard), upgradable to 500 u |
| Operating Software | Multi-channel gas analysis suite for Windows 7/10, compliant with GLP/GMP data integrity requirements |
| Bake-out Capability | Mass spectrometer chamber heatable to 200 °C for in-situ outgassing |
| Compliance | Designed to support ASTM D7622, ISO 10156, USP <1251>, and FDA 21 CFR Part 11 audit-trail functionality |
| Brand | Altamira Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BenchCAT Custom Microreactor |
| Instrument Category | Catalytic Reaction System |
| Reactor Volume | Small-scale (typically 0.1–10 mL) |
| Operating Pressure | Up to 100 bar (customizable to 200 bar) |
| Design Standard | ASME BPVC Section VIII Div. 1 compliant |
| Materials | 316L stainless steel, Hastelloy C-276, or quartz-lined options available |
| Temperature Range | Ambient to 500 °C |
| Flow Configuration | Continuous-flow, plug-flow, or recirculating modes |
| Gas/Liquid Handling | Dual-phase (gas–liquid–solid) catalytic operation supported |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300IR In Situ FTIR-Coupled Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira |
|---|---|
| Origin | USA |
| Model | AMI-300S Corrosion-Resistant Chemisorption Analyzer |
| Testing Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional 100 bar) |
| Analytical Capabilities | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | JW-MIX100 |
| Gas Range | Customizable |
| Mass Flow Controllers (MFCs) | 4 units |
| Column Configuration | Customizable breakthrough columns |
| Maximum Adsorption Pressure | 100 bar |
| Detector | Thermal Conductivity Detector (TCD) |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C (optional low-temp module: –130°C to 1200°C) |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated high-sensitivity TCD (dual-filament or quad-filament, W or Au/W), compatible with external MS, FTIR, FID, GC |
| Gas Handling | Built-in precision gas mixer, heated/insulated lines & valves, vapor-saturated gas generation (temperature-controlled saturator) |
| Sample Configuration | Removable clamshell furnace, quartz U-tube/bubble tube/straight-wall tubes (low-pressure) |
| Safety Systems | Multi-point temperature monitoring, over-temperature cutoff, TCD flow interlock, dry-run protection, front emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace + bed), FDA 21 CFR Part 11–ready audit trail (optional), GLP/GMP-compliant data export |
| Brand | 3P Instruments |
|---|---|
| Origin | Germany |
| Model | mixSorb S |
| Maximum Adsorption Pressure | 68 bar |
| Mass Flow Controllers (MFCs) | 4 |
| Detector | TCD (Thermal Conductivity Detector) |
| Temperature Control | Up to 400 °C pre-treatment, Linear Heating Rate: 10 K/min |
| Software | mixSorb Manager (real-time control & programmable operation), 3P sim (data fitting, breakthrough curve simulation, multicomponent adsorption modeling, selectivity/affinity/kinetics calculation) |
| Brand | 3P Instruments |
|---|---|
| Origin | Germany |
| Model | mixSorb L |
| Maximum Adsorption Pressure | 68 bar |
| Number of Mass Flow Controllers (MFCs) | 4 |
| Detector Type | TCD (Thermal Conductivity Detector) |
| Column Dimensions (Standard) | 30 mm ID × 200 mm length |
| Gas Range | Customizable |
| Column Configuration | Customizable |
| Temperature Pre-treatment Range | Up to 400 °C |
| Heating Rate | Up to 10 K/min |
| Software | mixSorb Manager & 3P sim |
| Compliance | Designed for GLP/GMP-aligned operation with audit-trail-capable data logging |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YG-97A Mercury Intrusion Porosimeter (Shale Porosity) |
| Price | Upon Request |
| Pore Diameter Range | 30 nm – 600 µm |
| Pressure Range | 0.01 – 50 MPa (7250 psi) |
| Vacuum Level | ≤ 0.05 Pa |
| Sample Chamber Volume | Up to 15 cm³ |
| Measurement Accuracy | ≤ 0.5% |
| Blank Volume at 50 MPa | ~0.25 mL |
| Safety | Integrated Mercury Vapor Containment System |
| Compliance | ISO 15901-1:2005, GB/T 21650.1-2008 |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | JW-TB400 Calcium Hydroxide-Specific Specific Surface Area and Pore Size Analyzer |
| Instrument Type | Specific Surface Area and Pore Size Analyzer |
| Principle | Static Volumetric Gas Adsorption Method |
| Number of Analysis Stations | 4 |
| Specific Surface Area Range | >0.0005 m²/g |
| Pressure Range | 10⁻⁵–0.998 atm |
| Theoretical Basis | Static Volumetric Adsorption Theory |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| X-ray Source | Sealed Mo-target Tube |
| Maximum Power | 1600 W |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.1° |
| Goniometer Geometry | Vertical θ–2θ |
| Goniometer Radius | 144 mm |
| Angular Range | 0°–150° |
| Detector | Photon-counting 2D Array Detector |
| Sample Stage | Temperature-Controlled Pouch-Cell Holder (−30 °C to 300 °C) |
| Dimensions | 900 mm × 680 mm × 550 mm |
| Weight | 100 kg |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | YG-97A Mercury Intrusion Porosimeter |
| Price | Upon Request |
| Pore Diameter Range | 30 nm – 600 µm |
| Pressure Range | 0.01 – 50 MPa (7250 psi) |
| Vacuum Level | ≤ 0.05 Pa |
| Sample Chamber Volume | Up to 15 cm³ |
| Measurement Accuracy | ≤ 0.5% |
| Blank Volume at 50 MPa | ~0.25 mL |
| Safety | Integrated Mercury Vapor Containment System |
| Compliance | ISO 15901-1:2005, GB/T 21650.1–2008 |