Empowering Scientific Discovery

Beijing Jingwei Gaobo Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelDSC 600
Sample CapacitySingle-sample
Instrument TypeDifferential Scanning Calorimeter
Temperature Range−150 °C to 600 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–200 °C/min
Temperature Precision±0.1 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRuboLab
OriginGermany
ModelRuboSORP MSB
Measurement PrincipleGravimetric (High-Temperature/High-Pressure Weight Method)
Temperature Range–10 °C to 400 °C (model-dependent
Pressure RangeUp to 700 bar
Mass Resolution1 μg (standard), 10 μg (high-load variant)
Maximum Sample Load10 g or 20 g (depending on configuration)
Compatible FluidsInert gases, corrosive/toxic gases, flammable/explosive gases, supercritical fluids, vapors, and gas mixtures
ComplianceDesigned for GLP/GMP-aligned workflows with audit-trail-capable software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSpecific Surface Area and Pore Size Analyzer
ModelJW-BK400 Quad-Station Specific Surface Area and Pore Size Analyzer
PrincipleStatic Volumetric Gas Adsorption Method
Number of Analysis Stations4 independent stations
Specific Surface Area Range0.005 m²/g to unlimited
Relative Pressure RangeP/P₀ = 10⁻⁴ to 0.99
Theoretical BasisGas Adsorption Theory, Static Volumetric Method
Repeatability≤ ±1.5% for surface area
Average Analysis Time per Sample~10 min (BET single-point)
Degassing Temperature RangeAmbient to 400 °C (±1 °C accuracy)
Pressure Transducers4 imported sensors, accuracy ≤ ±0.15% FS
Vacuum SystemStainless-steel multi-port parallel manifold with micro-adjustable vacuum speed control (2–200 mL/s)
Ultimate Vacuum10⁻² Pa
Data AcquisitionEthernet-based, Windows 7/XP (32/64-bit) compatible
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelJW-M100A True Density Analyzer (Open/Closed Cell Porosity)
Instrument TypeTrue Density Analyzer
Form FactorBenchtop Laboratory Instrument
Sample TypeSolid Materials
Density Range0 g/mL — No Known Upper Limit
Density Accuracy≤ 0.03%
Resolution0.00001 g/mL
Temperature Control Range0–50 °C
Measurement PrincipleGas Displacement (Helium/Nitrogen/Air)
Analysis Stations1
Vacuum SystemIntegrated Oil-Free Diaphragm Pump
Pressure SensorImported High-Stability Sensor, ±0.04% FS Accuracy, Long-Term Drift ≤ 0.025% FS
Thermal ManagementIntegrated Active Temperature Stabilization Module for Sample & Reference Chambers
Sample Chamber Volume Options10–120 mL (6 Standard Aluminum Cells Supplied)
Cycle Time≤ 2 Minutes per Measurement
Data InterfaceFull-Touch LCD Console + USB Export
ComplianceCE Certified, CNAS-Validated Calibration Traceability, Meets ISO 12154, ASTM D5550, and USP <699> Requirements for Solid Density Determination
Added to wishlistRemoved from wishlist 0
Add to compare
Temperature Range–125 to 1500 °C
Heating Rate0.1–40 °C/min
Max Sample Mass0.4 g
Balance Resolution0.1 µg
Furnace Options650 °C / 1200 °C / 1500 °C
DSC/DTA ModeYes
Gas ControlDual- or Quad-channel purge system
SoftwareInfinity Pro Thermal Analysis Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandISI
OriginUSA
ModelTGA 1000
Temperature RangeRT–1000°C
Balance Sensitivity0.1 µg
Heating/Cooling Rate0.1–300 K/min
Maximum Sample Mass0.4 g
Sample CapacitySingle
EnvironmentHigh-Temperature/Controlled-Atmosphere
ConstructionStainless Steel Gas Pathway
CoolingWater-Cooled Furnace
Software PlatformInfinity Pro for Windows
ComplianceASTM E1131, ISO 11358, USP <691>, GLP-Ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Origin CategoryDomestic (China)
ModelJW-MIX100 Pro
Gas RangeCustomizable
MFC Count4
Column ConfigurationCustomizable
Maximum Adsorption Pressure100 bar
DetectorTCD (Thermal Conductivity Detector)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSpecific Surface Area and Pore Size Analyzer
ModelMatrix 1000 Series
Analysis Stations12
Pore Size Range0.35 – 500 nm
Pressure Range10⁻⁸ – 0.998 atm
Theoretical ModelsHK, SF, BJH, MP, t-plot, DR, DA, DFT/NLDFT
Ambient Temperature Range15 – 40 °C
Ultimate Vacuum10⁻⁸ Pa
Adsorption GasesN₂, Ar, Kr, CO₂, CH₄, C₂H₄, C₂H₆, H₂O, benzene, toluene, xylene, NH₃, SO₂, H₂S
Degassing Temp RangeRT – 400 °C (±0.1 °C)
Pressure Sensors1000 Torr (0.05% F.S.), optional 10/1/0.1 Torr for micropore resolution
Thermal Stability±0.1 °C valve box temperature control
Corrosion ProtectionFFKM seals + fluoropolymer-coated gas path
Added to wishlistRemoved from wishlist 0
Add to compare
BrandISI
OriginUSA
ModelSTA 650
Temperature Range–125 to 650 °C
Heating Rate0.1–100 °C/min
Maximum Sample Mass400 mg
Balance Resolution0.1 µg
SoftwareInfinity Pro Thermal Analysis Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
ManufacturerYes
Product TypeDomestic
ModelYG-23A Mercury Intrusion Porosimeter (Pore Size Distribution & Porosity Analysis)
PriceUpon Request
Pore Size Range30 nm – 126 µm
Pressure Range0.01 – 50 MPa
Pore Volume Range0.3 – 3.5 mL
Measurement Accuracy≤ 0.5%
Sample Chamber VolumeUp to 15 cm³
Vacuum Level≤ 0.05 Pa
Blank Volume at 50 MPa~0.25 mL
SafetyIntegrated mercury vapor containment system
ComplianceISO 15901-1:2005, GB/T 21650.1-2008
Analysis OutputsCumulative pore volume, cumulative specific surface area, average pore diameter, pore size distribution curve, pore throat ratio, intrusion/extrusion hysteresis curves
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelJW-M100A Automated True Density Analyzer
Instrument TypeTrue Density Analyzer
Form FactorBenchtop Laboratory Instrument
Sample TypeSolid Materials
Density Measurement Range0 g/mL to no known upper limit
Density Accuracy≤ 0.03%
Resolution0.00001 g/mL
Temperature Control Range0–50 °C
Minimum Sample Mass5 g
PrincipleGas Displacement (Helium, Nitrogen, or Air)
Analysis Stations1
Pressure Sensor Accuracy±0.04% FS
Long-Term Stability±0.025% FS
Vacuum SourceIntegrated Oil-Free Diaphragm Pump
Sample Cell Volumes10–120 mL (6 standard aluminum cells included)
Cycle Time≤ 2 minutes per analysis
Data InterfaceFull-touch LCD panel with USB export
ComplianceCE certified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelJW-DX400 Specific Surface Area Analyzer
Instrument TypeSpecific Surface Area Analyzer
Operating PrincipleDynamic Flow (Carrier Gas) Method
Number of Analysis Stations4
Measurable Surface Area Range0.01 m²/g to unlimited upper limit
Operating PressureAtmospheric pressure
Theoretical BasisDynamic Chromatographic Method
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSpecific Surface Area and Pore Size Analyzer
ModelJW-BK300C Research-Grade Specific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations3
Specific Surface Area RangeDown to 0.0001 m²/g
Relative Pressure Rangep/p₀ down to 10⁻⁸ (N₂ at 77 K)
Theoretical ModelsBET Multilayer Adsorption, BJH Desorption for Mesopores, HK/SF for Micropores, NLDFT Non-Local Density Functional Theory
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument CategoryDomestic
ModelJW-TB400 High-Throughput Specific Surface Area and Pore Size Analyzer
Instrument TypeSpecific Surface Area and Pore Size Analyzer
Measurement PrincipleStatic Volumetric Gas Adsorption
Number of Analysis Stations4
Specific Surface Area Range>0.0005 m²/g
Pressure Range1×10⁻⁵ – 0.998 atm
Analytical TheoryStatic Volumetric Method
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB (Jingwei Gaobo)
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelLattice GO
Instrument TypePowder X-ray Diffractometer
Instrument ConfigurationPortable
X-ray Tube Power30 W
Angular Accuracy±0.01°
Angular Resolution0.2°
Dimensions (L×W×H)120 mm × 300 mm × 305 mm
Weight12 kg
X-ray TubeCu anode, 30 kV / 1 mA
Goniometer GeometryVertical θ–2θ Bragg–Brentano
Goniometer Radius110 mm
DetectorPhoton-counting 2D array detector
Scan Speeds6°/min or 13°/min (selectable)
2θ Range0°–130°
Battery Runtime3 hours
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
ManufacturerJWGB Instrument Co., Ltd.
TypeCustom-Built Benchtop Microreactor System
Reactor ConfigurationTubular
Operating PressureHigh-Pressure
Volume ClassSmall-Scale
ComplianceDesigned for ASTM D3663, ISO 15901-2, and IUPAC physisorption/chemisorption methodology
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
ModelAMI 400TPx
PricingUpon Request
Core FunctionalityFully Automated TPD, TPR, TPO, TPSR, Pulse Chemisorption, Single-Point BET, Optional MS/GC/FID/FTIR Coupling
Gas CompatibilityInert, Reducing (H₂), Oxidizing (O₂, NO, CO₂), Corrosive (SO₂, H₂S)
Control ArchitectureIntegrated Pneumatic Valve Manifold with Real-Time Flow Path Visualization
SoftwareProprietary ChemiSoft™ with Live System Status Dashboard, Parameter Logging, and Audit-Trail-Ready Data Export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic Instrument
ModelDX Series Dedicated Specific Surface Area Analyzer for Cathode Materials (28 Samples per Hour)
Instrument TypeSpecific Surface Area Analyzer
Operating PrincipleDynamic Flow Method (Carrier Gas Chromatography)
Number of Analysis Stations4
Measurable Surface Area Range0.01 m²/g to unlimited upper limit
Operating PressureAmbient Pressure
Theoretical BasisDynamic Chromatographic Adsorption Theory
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeDynamic Specific Surface Area Analyzer
ModelJWGB DX Series (28 Samples per Hour)
Analysis Stations4
Measurement PrincipleDynamic Chromatographic Method (Flow Method)
Pressure RangeAtmospheric Pressure
Theoretical BasisDirect Comparison Method & BET Theory
Specific Surface Area Range0.01 m²/g to Unlimited
Operating ConditionLiquid Nitrogen Temperature (−196 °C), N₂/He Carrier Gas Mixture
Detection SystemHigh-Precision Thermal Conductivity Detector (TCD)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
ManufacturerYes
Product TypeDomestic
ModelDX400 Hard Carbon Anode-Specific Specific Surface Area Analyzer (28 Samples per Hour)
Instrument CategorySpecific Surface Area Analyzer
Operating PrincipleDynamic Flow Method (Gas Chromatography-Based)
Number of Analysis Stations4
Measurement Range0.01 m²/g to unlimited upper limit
Pressure ConditionAmbient Pressure
Theoretical BasisDynamic Chromatographic Adsorption Theory
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRuboLab
OriginGermany
ModelRuboSORP MSB
Measurement PrincipleMagnetic Suspension Balance
Number of Gas Inlets8
Maximum Operating Pressure700 bar
Temperature Range−10 °C to +400 °C
Mass ResolutionDown to 1 μg
Maximum Sample Load10 g or 20 g (model-dependent)
Compatible FluidsInert gases, corrosive/toxic gases, flammable/explosive gases, supercritical fluids, vapors, and gas mixtures
ComplianceDesigned for GLP/GMP-aligned workflows with full audit trail support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelJW-M100A Foam-Specific True Density and Porosity Analyzer
Instrument TypeTrue Density Analyzer
Form FactorBenchtop Laboratory Instrument
Sample TypeSolid Materials (Including Rigid & Flexible Foams)
Measurement PrincipleGas Displacement Pycnometry (Helium/Nitrogen/Air)
Density Range0 g/mL to No Known Upper Limit
Density Accuracy≤ 0.03% (RSD)
Resolution0.00001 g/mL
Temperature Control Range0–50 °C
Analysis Station1
Vacuum SystemIntegrated Oil-Free Diaphragm Pump
Pressure SensorImported High-Stability Transducer, 0.04% FS Accuracy, Long-Term Drift ≤ 0.025% FS
Pressure RegulationFully Automated, Max Pressure ≤ Atmospheric
Sample Chamber Volume Options10–120 mL (6 Standard Aluminum Cells Supplied)
Cycle Time≤ 2 Minutes per Measurement
Data InterfaceFull-Touch LCD Console + USB Export
ComplianceCE Certified, Meets JJG 99–2006 (Chinese National Metrology Verification Regulation), Supports GLP Audit Trail via Exported Timestamped Logs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
ManufacturerYes
Product TypeDomestic
ModelDX Graphite-Specific Specific Surface Area Analyzer (28 Samples per Hour)
Instrument CategorySpecific Surface Area Analyzer
PrincipleDynamic Flow Method (Gas Chromatography-Based)
Number of Analysis Stations4
Measurement Range0.01 m²/g to unlimited upper limit
Operating PressureAmbient pressure
Theoretical BasisDynamic Chromatographic Method with Thermal Conductivity Detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelJW-M100A True Density Analyzer for Ceramic Proppants and Quartz Sand
Instrument TypeTrue Density Analyzer
Form FactorBenchtop Laboratory Instrument
Sample TypeSolid Materials
Density Measurement Range0 g/mL — No Upper Limit
Density Accuracy≤ 0.03% (RSD)
Resolution0.00001 g/mL
Temperature Control Range0–50 °C
Measurement PrincipleGas Displacement (Helium/Nitrogen/Air)
Analysis Stations1
Vacuum SystemIntegrated Oil-Free Diaphragm Pump
Pressure SensorImported High-Stability Sensor, ±0.04% FS Accuracy, Long-Term Drift ≤ 0.025% FS
Thermal ManagementIntegrated Precision Isothermal Module for Sample & Reference Chambers
Sample Chamber Volume Options10–120 mL (6 Standard Aluminum Cells Supplied)
Data InterfaceFull-Touch LCD Console + USB Export
ComplianceCE Certified
CalibrationIncludes Certified Reference Standards
Testing Time per Sample≤ 2 Minutes
Porosity ModesOpen-Cell & Closed-Cell Porosity Calculation
SoftwareEmbedded Firmware with Audit-Trail Capable Data Logging (GLP-Compatible)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0