- All
- Favorite
- Popular
- Most rated
| Brand | RuboLab |
|---|---|
| Origin | Germany |
| Model | RuboSORP MSB |
| Measurement Principle | Magnetic Suspension Balance |
| Number of Gas Inlets | 8 |
| Maximum Operating Pressure | 700 bar |
| Temperature Range | −10 °C to +400 °C |
| Mass Resolution | Down to 1 μg |
| Maximum Sample Load | 10 g or 20 g (model-dependent) |
| Compatible Fluids | Inert gases, corrosive/toxic gases, flammable/explosive gases, supercritical fluids, vapors, and gas mixtures |
| Compliance | Designed for GLP/GMP-aligned workflows with full audit trail support |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HX-100 Basic Chemisorption Analyzer |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Heating Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Ramp Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Functions | TPR, TPO, TPD, TPSR, Pulse Chemisorption, Pulse Calibration, Dynamic BET Surface Area |
| Sample Capacity | 0.1–1 g |
| Analysis Stations | 1 |
| Cooling Method | Forced-air rapid cool-down |
| Detection System | High-stability 4-filament TCD (Re-W wire, 200°C heated) |
| Gas Flow Control | 2–100 mL/min |
| Sample Tube Options | Quartz U-tube or bubble tube |
| Tubing Material | 316 stainless steel, 1/16″ OD |
| System Dead Volume | Minimized via low-volume valves and heated manifold |
| Cold Trap | Integrated desiccant trap downstream of sample tube |
| Quantitative Loop | Precision-calibrated pulse injection port |
| Low-Temp Option | –100°C to 1200°C (with cryo-cooler) |
| Dimensions | 43 × 64 × 62 cm (W × H × D) |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Chemisorption Analyzer |
| Model | HX-100 |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Heating Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPSR, Pulse Chemisorption, Pulse Calibration, Dynamic BET Surface Area |
| Detector | High-Stability 4-Filament TCD (Re-W alloy, 200 °C heated) |
| Sample Tube | Quartz U-tube or bubble tube (0.1–1 g capacity) |
| Gas Flow Control | 2–100 mL/min |
| Valve & Tubing | Heated 1/16″ 316 stainless steel lines |
| Dimensions | 43 cm (W) × 64 cm (H) × 62 cm (D) |
| Optional Accessories | Cryogenic trap (–100 °C), Mass Spectrometer (MS) interface, GC integration module |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AMI-300HP High-Pressure Chemisorption Analyzer (100 bar) |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable up to 12 |
| Heating Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Ramp Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar / 100 bar (dual-range configuration) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 TPD/TPO/TPR Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300Neo Basic Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Ramp Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated High-Sensitivity TCD (dual-filament or quad-filament, W or Au/W), MS/GC/FTIR/FID compatibility |
| Sample Capacity | 0.1–1.0 g |
| Sample Tube Types | Quartz U-tube, bubble tube, straight-wall tube (low-pressure) |
| Tubing | 1/16″ OD 316 SS, heated throughout |
| Gas Mixing | Internal precision gas mixer (no external mixer required) |
| Cooling | Automated air-cooling module |
| Safety Systems | Dual-zone temperature monitoring, over-temperature cutoff, TCD flow interlock, front-panel emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace & bed), GLP-compliant data audit trail, FDA 21 CFR Part 11-ready configuration options |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AMI-400 Automated Chemisorption Analyzer |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300IR In Situ FTIR-Coupled Chemisorption Analyzer |
| Test Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Analytical Modes | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira |
|---|---|
| Origin | USA |
| Model | AMI-300S Corrosion-Resistant Chemisorption Analyzer |
| Testing Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200 °C |
| Isothermal Stability | ±0.01 °C |
| Heating Rate | 1–50 °C/min |
| Pressure Range | Atmospheric to 30 bar (optional 100 bar) |
| Analytical Capabilities | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Brand | Altamira (USA) |
|---|---|
| Origin | USA |
| Model | AMI-300 |
| Instrument Type | Chemisorption Analyzer |
| Measurement Principle | Continuous Flow Method |
| Gas Inlet Ports | Expandable to 12 |
| Temperature Range | Ambient to 1200°C (optional low-temp module: –130°C to 1200°C) |
| Isothermal Stability | ±0.01°C |
| Heating Rate | 1–50°C/min |
| Pressure Range | Atmospheric to 30 bar (optional up to 100 bar) |
| Core Functions | TPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration |
| Detector Options | Integrated high-sensitivity TCD (dual-filament or quad-filament, W or Au/W), compatible with external MS, FTIR, FID, GC |
| Gas Handling | Built-in precision gas mixer, heated/insulated lines & valves, vapor-saturated gas generation (temperature-controlled saturator) |
| Sample Configuration | Removable clamshell furnace, quartz U-tube/bubble tube/straight-wall tubes (low-pressure) |
| Safety Systems | Multi-point temperature monitoring, over-temperature cutoff, TCD flow interlock, dry-run protection, front emergency stop |
| Software | Windows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace + bed), FDA 21 CFR Part 11–ready audit trail (optional), GLP/GMP-compliant data export |
Show next