Empowering Scientific Discovery

Beijing Jingwei Gaobo Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRuboLab
OriginGermany
ModelRuboSORP MSB
Measurement PrincipleMagnetic Suspension Balance
Number of Gas Inlets8
Maximum Operating Pressure700 bar
Temperature Range−10 °C to +400 °C
Mass ResolutionDown to 1 μg
Maximum Sample Load10 g or 20 g (model-dependent)
Compatible FluidsInert gases, corrosive/toxic gases, flammable/explosive gases, supercritical fluids, vapors, and gas mixtures
ComplianceDesigned for GLP/GMP-aligned workflows with full audit trail support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelHX-100 Basic Chemisorption Analyzer
Instrument TypeChemisorption Analyzer
Measurement PrincipleContinuous Flow Method
Gas Inlet PortsExpandable to 12
Heating Temperature RangeAmbient to 1200°C
Isothermal Stability±0.01°C
Ramp Rate1–50°C/min
Pressure RangeAtmospheric to 30 bar (optional up to 100 bar)
Analytical FunctionsTPR, TPO, TPD, TPSR, Pulse Chemisorption, Pulse Calibration, Dynamic BET Surface Area
Sample Capacity0.1–1 g
Analysis Stations1
Cooling MethodForced-air rapid cool-down
Detection SystemHigh-stability 4-filament TCD (Re-W wire, 200°C heated)
Gas Flow Control2–100 mL/min
Sample Tube OptionsQuartz U-tube or bubble tube
Tubing Material316 stainless steel, 1/16″ OD
System Dead VolumeMinimized via low-volume valves and heated manifold
Cold TrapIntegrated desiccant trap downstream of sample tube
Quantitative LoopPrecision-calibrated pulse injection port
Low-Temp Option–100°C to 1200°C (with cryo-cooler)
Dimensions43 × 64 × 62 cm (W × H × D)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJWGB
OriginBeijing, China
Manufacturer TypeDirect Manufacturer
Instrument TypeChemisorption Analyzer
ModelHX-100
Measurement PrincipleContinuous Flow Method
Gas Inlet PortsExpandable to 12
Heating Temperature RangeAmbient to 1200 °C
Isothermal Stability±0.01 °C
Ramp Rate1–50 °C/min
Pressure RangeAtmospheric to 30 bar (optional up to 100 bar)
Core FunctionsTPR, TPO, TPD, TPSR, Pulse Chemisorption, Pulse Calibration, Dynamic BET Surface Area
DetectorHigh-Stability 4-Filament TCD (Re-W alloy, 200 °C heated)
Sample TubeQuartz U-tube or bubble tube (0.1–1 g capacity)
Gas Flow Control2–100 mL/min
Valve & TubingHeated 1/16″ 316 stainless steel lines
Dimensions43 cm (W) × 64 cm (H) × 62 cm (D)
Optional AccessoriesCryogenic trap (–100 °C), Mass Spectrometer (MS) interface, GC integration module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAltamira Instruments (USA)
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelAMI-300HP High-Pressure Chemisorption Analyzer (100 bar)
Instrument TypeChemisorption Analyzer
Measurement PrincipleContinuous Flow Method
Gas Inlet PortsExpandable up to 12
Heating Temperature RangeAmbient to 1200 °C
Isothermal Stability±0.01 °C
Ramp Rate1–50 °C/min
Pressure RangeAtmospheric to 30 bar / 100 bar (dual-range configuration)
Analytical ModesTPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAltamira (USA)
OriginUSA
ModelAMI-300 TPD/TPO/TPR Chemisorption Analyzer
Test PrincipleContinuous Flow Method
Gas Inlet PortsExpandable to 12
Temperature RangeAmbient to 1200 °C
Isothermal Stability±0.01 °C
Heating Rate1–50 °C/min
Pressure RangeAtmospheric to 30 bar (optional up to 100 bar)
FunctionsTPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAltamira (USA)
OriginUSA
ModelAMI-300Neo Basic Chemisorption Analyzer
Test PrincipleContinuous Flow Method
Gas Inlet PortsExpandable to 12
Temperature RangeAmbient to 1200°C
Isothermal Stability±0.01°C
Ramp Rate1–50°C/min
Pressure RangeAtmospheric to 30 bar (optional up to 100 bar)
Core FunctionsTPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAltamira (USA)
OriginUSA
ModelAMI-300
Instrument TypeChemisorption Analyzer
Measurement PrincipleContinuous Flow Method
Gas Inlet PortsExpandable to 12
Temperature RangeAmbient to 1200°C
Isothermal Stability±0.01°C
Heating Rate1–50°C/min
Pressure RangeAtmospheric to 30 bar (optional up to 100 bar)
Analytical ModesTPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration
Detector OptionsIntegrated High-Sensitivity TCD (dual-filament or quad-filament, W or Au/W), MS/GC/FTIR/FID compatibility
Sample Capacity0.1–1.0 g
Sample Tube TypesQuartz U-tube, bubble tube, straight-wall tube (low-pressure)
Tubing1/16″ OD 316 SS, heated throughout
Gas MixingInternal precision gas mixer (no external mixer required)
CoolingAutomated air-cooling module
Safety SystemsDual-zone temperature monitoring, over-temperature cutoff, TCD flow interlock, front-panel emergency stop
SoftwareWindows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace & bed), GLP-compliant data audit trail, FDA 21 CFR Part 11-ready configuration options
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAltamira (USA)
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelAMI-400 Automated Chemisorption Analyzer
Instrument TypeChemisorption Analyzer
Measurement PrincipleContinuous Flow Method
Gas Inlet PortsExpandable to 12
Temperature RangeAmbient to 1200 °C
Isothermal Stability±0.01 °C
Heating Rate1–50 °C/min
Pressure RangeAtmospheric to 30 bar (optional up to 100 bar)
Analytical ModesTPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAltamira (USA)
OriginUSA
ModelAMI-300IR In Situ FTIR-Coupled Chemisorption Analyzer
Test PrincipleContinuous Flow Method
Gas Inlet PortsExpandable to 12
Temperature RangeAmbient to 1200 °C
Isothermal Stability±0.01 °C
Heating Rate1–50 °C/min
Pressure RangeAtmospheric to 30 bar (optional up to 100 bar)
Analytical ModesTPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAltamira
OriginUSA
ModelAMI-300S Corrosion-Resistant Chemisorption Analyzer
Testing PrincipleContinuous Flow Method
Gas Inlet PortsExpandable to 12
Temperature RangeAmbient to 1200 °C
Isothermal Stability±0.01 °C
Heating Rate1–50 °C/min
Pressure RangeAtmospheric to 30 bar (optional 100 bar)
Analytical CapabilitiesTPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAltamira (USA)
OriginUSA
ModelAMI-300
Instrument TypeChemisorption Analyzer
Measurement PrincipleContinuous Flow Method
Gas Inlet PortsExpandable to 12
Temperature RangeAmbient to 1200°C (optional low-temp module: –130°C to 1200°C)
Isothermal Stability±0.01°C
Heating Rate1–50°C/min
Pressure RangeAtmospheric to 30 bar (optional up to 100 bar)
Core FunctionsTPR, TPO, TPD, TPS, Pulse Chemisorption, Pulse Calibration
Detector OptionsIntegrated high-sensitivity TCD (dual-filament or quad-filament, W or Au/W), compatible with external MS, FTIR, FID, GC
Gas HandlingBuilt-in precision gas mixer, heated/insulated lines & valves, vapor-saturated gas generation (temperature-controlled saturator)
Sample ConfigurationRemovable clamshell furnace, quartz U-tube/bubble tube/straight-wall tubes (low-pressure)
Safety SystemsMulti-point temperature monitoring, over-temperature cutoff, TCD flow interlock, dry-run protection, front emergency stop
SoftwareWindows-based, fully automated experiment sequencing, real-time dual-temperature logging (furnace + bed), FDA 21 CFR Part 11–ready audit trail (optional), GLP/GMP-compliant data export
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0