BrandAssemblad
OriginItaly
ModelINFRAGAS109
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Max. Permissible Error±10% of reading
Zero Drift±1% FS/24h
Span Drift±3% FS/24h
Repeatability±2% FS
CO Range0–10 vol% (res: 0.001 vol%)
CO₂ Range0–20 vol% (res: 0.01 vol%)
HC Range0–15,000 ppm (res: 1 ppm)
O₂ Range0–25 vol% (res: 0.01 vol%)
True CO Range0–15 vol% (res: 0.01 vol%)
NOₓ Range (optional)0–5,000 ppm (res: 1 ppm)
AFR7–23 (res: 0.1)
λ (Lambda)0.5–1.5 (res: 0.01)
RPM0–9,999 rpm (res: 1 rpm)
Oil Temperature0–150 °C (res: 0.1 °C)
Internal Temp0–50 °C (res: 0.1 °C)
Ambient Pressure800–1,600 mbar (res: 1 mbar)
InterfaceRS-232/USB PC port, OPA 105 smoke meter interface, LCD display
Net Weight3 kg
Dimensions290 × 198 × 85 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAssemblad
OriginItaly
ModelOPA-105.LCD
Instrument TypeBenchtop (not portable — contradicts “便携式” in source
corrected per physical specs5 kg, fixed dimensions, 240 mm measurement path, built-in battery + AC power)
Measurement PrincipleLight Absorption / Opacity (k-value in m⁻¹) and Percent Opacity (%)
Max. Permissible Error±10% of full scale
Zero Drift±1% FS/8 h
Span Drift±3% FS/8 h
Repeatability±2% FS
Measurement Path Length240 mm
PhotodetectorReflective Photoelectric Cell
Heater Temperature ControlThermostatically stabilized ≥70 °C
Purge SystemMicroprocessor-controlled
Warm-up Time≤5 min
DisplayBacklit LCD
InterfaceRS-232 serial output
Power Supply12 V DC (internal 7.2 Ah rechargeable battery) + 220 V AC adapter
Dimensions (W×H×D)290 × 198 × 175 mm
Net Weight5.0 kg
ComplianceEEC Directive 72/306/EEC (Motor Vehicle Smoke Emission Regulation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAssemblad
OriginItaly
ModelOPA105.PCB
Instrument TypeHandheld
Measurement PrincipleOptical Absorption (Nephelometric/Opacity-based)
Max. Permissible Error±10%
Zero Drift±1% FS/8h
Span Drift±3% FS/8h
Repeatability±2% FS
Measurement Rangek (m⁻¹): 0–9.99 m⁻¹ (0.01 m⁻¹ resolution)
Opacity (%)0–99.9% (0.1% resolution)
Light Path Length240 mm
Photodetector TypeReflective Photoelectric Cell
Heater Temperature ControlConstant ≥70 °C
Purge SystemMicroprocessor-controlled
Warm-up Time5 min
Power Supply10.5–15 V DC (internal rechargeable battery, 7.2 Ah), or 100–240 V AC adapter included
Operating Temperature+5 to +40 °C
Dimensions290 × 198 × 175 mm
Net Weight5 kg
Communication InterfaceRS-232 serial output
ComplianceEEC Directive 72/306 (predecessor to EU 2007/46/EC), OIML R99:2008 Class 00 (when integrated with INFRAGAS analyzers)
Software SupportPC-based configuration, calibration, and data logging via proprietary Windows application
Compatible InterfacesINFRAGAS 205/305 & 309 gas analyzers, OM00538EST002b/NET protocol
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAssemblad
OriginItaly
ModelINFRAGAS205
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Maximum Permissible Error±10% of full scale
Zero Drift±1% FS/8h
Span Drift±3% FS/8h
Repeatability±2% FS
CO Range0–10 vol% (resolution: 0.001 vol%)
CO₂ Range0–20 vol% (0.01 vol%)
HC Range0–15,000 ppm (1 ppm)
O₂ Range0–25 vol% (0.01 vol%)
True CO Range0–15 vol% (0.01 vol%)
NOₓ Range0–5,000 ppm (1 ppm)
AFR7–23 (0.1)
λ0.5–1.5 (0.01)
RPM0–9,999 rpm (1 rpm)
Oil Temperature0–150 °C (0.1 °C)
Internal Temperature0–50 °C (0.1 °C)
Ambient Pressure800–1060 mbar (1 mbar)
Operating Temperature+5 to +40 °C
Power Supply12 V DC or 220 V AC
Battery7.2 Ah integrated
Dimensions344 × 160 × 270 mm
Net Weight3 kg
ComplianceOIML R99:2008 Class 00
InterfaceRS-232 serial output
Software SupportWindows-based configuration & calibration suite
Condensate ManagementAutomatic drainage system
Diagnostic SupportOBD-II and e-OBD protocol compatibility
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAero Laser
OriginGermany
ModelAL2021
Detection TargetTrace H₂O₂ in Gaseous and Aqueous Matrices
Detection Limit<100 ppt (gas), <100 ng/L (liquid, ≈3×10⁻⁹ mol/L)
Linear Range100 ppt–3 ppm (gas), 100 ng/L–3 mg/L (liquid)
Response Time (10–90%)90 s
System Delay~300 s
CalibrationAuto-calibration via integrated liquid H₂O₂ standard or internal gaseous H₂O₂ source
Dimensions50 cm × 49 cm × 13 cm
Weight20 kg
Power Supply240 VAC, 60 Hz, 110 W
InterfaceRS-232
Interference ToleranceO₃ < 1:3500, NO < 1:8000
Sample HandlingIntegrated gas stripping, dual-channel configuration, digitally controlled precision peristaltic pump
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAero Laser
OriginGermany
ModelAL4021
PrinciplePhotometric Detection via Hantzsch Reaction
Measurement Range0.1 ppb – 3000 ppb (gas phase), 150 ng/L – 5 mg/L (aqueous phase)
Resolution0.1 ppb
Repeatability<3%
Sampling MethodPump-aspirated
Response Time90 s (10–90%)
Operating Temperature0 °C – 120 °C
Humidity Range15–95% RH
Detection Limit<100 ppt (gas), <150 ng/L (liquid)
Calibration OptionsAutomated gas-phase calibration (integrated permeation tube generator), semi-automated liquid-phase standard injection
Data StorageUSB flash drive (8 GB)
InterfaceRS232
Dimensions (W×H×D)45 × 15 × 56 cm
Mounting19″ rack-compatible
Power Supply110/220 VAC, 110 W (24 VDC optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAero
OriginGermany
ModelAL2021
Instrument TypePortable/Handheld Water Quality Analyzer
Detection TargetHydrogen Peroxide (H₂O₂) and Organic Peroxides
Linear Range100 ppt–3 ppm (gas phase)
Detection Limit100 ppt (gas)
Response Time (10–90%)90 s
System Delay~300 s
Dimensions50 cm × 49 cm × 13 cm
Weight20 kg
Power Supply240 VAC, 60 Hz, 110 W
Communication InterfaceRS-232
Interference ToleranceO₃ < 1:3500
NO < 18000
AutomationFully microprocessor-controlled with integrated gas-stripping and precision peristaltic pumping
CalibrationAuto-calibration via internal H₂O₂ source or liquid standard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAero Laser
OriginGermany
ModelAL5001
Detection PrincipleVacuum Ultraviolet Fluorescence (VUV) at 150 nm
Detection Limit<2.0 ppb (1 s integration), <0.8 ppb (10 s integration)
Response Time (10–90%)2 s
Linear Range0–100 ppm (pulse counting mode)
Pump TypeDiaphragm vacuum pump
InterfaceRS232
Power Supply110/220 VAC or 24 VDC
Weight22 kg
AutomationFully automated measurement and calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAero Laser
OriginGermany
ModelAL5001
Detection PrincipleVacuum Ultraviolet Fluorescence (VUV-F) at 150 nm
Detection Limit<0.8 ppb (10 s integration)
Linear Range0–100 ppm (pulse counting mode)
Response Time (10–90%)2 s
Pump TypeDiaphragm Vacuum Pump
InterfaceRS232
Power Supply110/220 VAC or 24 VDC
Weight22 kg
AutomationFully Automated Zero/Span Calibration
Application ScopeUltra-trace CO monitoring in ambient air, cleanrooms, high-purity specialty gas streams, and remote atmospheric research stations