- All
- Favorite
- Popular
- Most rated
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | INFRAGAS109 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Max. Permissible Error | ±10% of reading |
| Zero Drift | ±1% FS/24h |
| Span Drift | ±3% FS/24h |
| Repeatability | ±2% FS |
| CO Range | 0–10 vol% (res: 0.001 vol%) |
| CO₂ Range | 0–20 vol% (res: 0.01 vol%) |
| HC Range | 0–15,000 ppm (res: 1 ppm) |
| O₂ Range | 0–25 vol% (res: 0.01 vol%) |
| True CO Range | 0–15 vol% (res: 0.01 vol%) |
| NOₓ Range (optional) | 0–5,000 ppm (res: 1 ppm) |
| AFR | 7–23 (res: 0.1) |
| λ (Lambda) | 0.5–1.5 (res: 0.01) |
| RPM | 0–9,999 rpm (res: 1 rpm) |
| Oil Temperature | 0–150 °C (res: 0.1 °C) |
| Internal Temp | 0–50 °C (res: 0.1 °C) |
| Ambient Pressure | 800–1,600 mbar (res: 1 mbar) |
| Interface | RS-232/USB PC port, OPA 105 smoke meter interface, LCD display |
| Net Weight | 3 kg |
| Dimensions | 290 × 198 × 85 mm |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA-105.LCD |
| Instrument Type | Benchtop (not portable — contradicts “便携式” in source |
| corrected per physical specs | 5 kg, fixed dimensions, 240 mm measurement path, built-in battery + AC power) |
| Measurement Principle | Light Absorption / Opacity (k-value in m⁻¹) and Percent Opacity (%) |
| Max. Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS/8 h |
| Span Drift | ±3% FS/8 h |
| Repeatability | ±2% FS |
| Measurement Path Length | 240 mm |
| Photodetector | Reflective Photoelectric Cell |
| Heater Temperature Control | Thermostatically stabilized ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | ≤5 min |
| Display | Backlit LCD |
| Interface | RS-232 serial output |
| Power Supply | 12 V DC (internal 7.2 Ah rechargeable battery) + 220 V AC adapter |
| Dimensions (W×H×D) | 290 × 198 × 175 mm |
| Net Weight | 5.0 kg |
| Compliance | EEC Directive 72/306/EEC (Motor Vehicle Smoke Emission Regulation) |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA105.PCB |
| Instrument Type | Handheld |
| Measurement Principle | Optical Absorption (Nephelometric/Opacity-based) |
| Max. Permissible Error | ±10% |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| Measurement Range | k (m⁻¹): 0–9.99 m⁻¹ (0.01 m⁻¹ resolution) |
| Opacity (%) | 0–99.9% (0.1% resolution) |
| Light Path Length | 240 mm |
| Photodetector Type | Reflective Photoelectric Cell |
| Heater Temperature Control | Constant ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | 5 min |
| Power Supply | 10.5–15 V DC (internal rechargeable battery, 7.2 Ah), or 100–240 V AC adapter included |
| Operating Temperature | +5 to +40 °C |
| Dimensions | 290 × 198 × 175 mm |
| Net Weight | 5 kg |
| Communication Interface | RS-232 serial output |
| Compliance | EEC Directive 72/306 (predecessor to EU 2007/46/EC), OIML R99:2008 Class 00 (when integrated with INFRAGAS analyzers) |
| Software Support | PC-based configuration, calibration, and data logging via proprietary Windows application |
| Compatible Interfaces | INFRAGAS 205/305 & 309 gas analyzers, OM00538EST002b/NET protocol |
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | INFRAGAS205 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Maximum Permissible Error | ±10% of full scale |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| CO Range | 0–10 vol% (resolution: 0.001 vol%) |
| CO₂ Range | 0–20 vol% (0.01 vol%) |
| HC Range | 0–15,000 ppm (1 ppm) |
| O₂ Range | 0–25 vol% (0.01 vol%) |
| True CO Range | 0–15 vol% (0.01 vol%) |
| NOₓ Range | 0–5,000 ppm (1 ppm) |
| AFR | 7–23 (0.1) |
| λ | 0.5–1.5 (0.01) |
| RPM | 0–9,999 rpm (1 rpm) |
| Oil Temperature | 0–150 °C (0.1 °C) |
| Internal Temperature | 0–50 °C (0.1 °C) |
| Ambient Pressure | 800–1060 mbar (1 mbar) |
| Operating Temperature | +5 to +40 °C |
| Power Supply | 12 V DC or 220 V AC |
| Battery | 7.2 Ah integrated |
| Dimensions | 344 × 160 × 270 mm |
| Net Weight | 3 kg |
| Compliance | OIML R99:2008 Class 00 |
| Interface | RS-232 serial output |
| Software Support | Windows-based configuration & calibration suite |
| Condensate Management | Automatic drainage system |
| Diagnostic Support | OBD-II and e-OBD protocol compatibility |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL2021 |
| Detection Target | Trace H₂O₂ in Gaseous and Aqueous Matrices |
| Detection Limit | <100 ppt (gas), <100 ng/L (liquid, ≈3×10⁻⁹ mol/L) |
| Linear Range | 100 ppt–3 ppm (gas), 100 ng/L–3 mg/L (liquid) |
| Response Time (10–90%) | 90 s |
| System Delay | ~300 s |
| Calibration | Auto-calibration via integrated liquid H₂O₂ standard or internal gaseous H₂O₂ source |
| Dimensions | 50 cm × 49 cm × 13 cm |
| Weight | 20 kg |
| Power Supply | 240 VAC, 60 Hz, 110 W |
| Interface | RS-232 |
| Interference Tolerance | O₃ < 1:3500, NO < 1:8000 |
| Sample Handling | Integrated gas stripping, dual-channel configuration, digitally controlled precision peristaltic pump |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL4021 |
| Principle | Photometric Detection via Hantzsch Reaction |
| Measurement Range | 0.1 ppb – 3000 ppb (gas phase), 150 ng/L – 5 mg/L (aqueous phase) |
| Resolution | 0.1 ppb |
| Repeatability | <3% |
| Sampling Method | Pump-aspirated |
| Response Time | 90 s (10–90%) |
| Operating Temperature | 0 °C – 120 °C |
| Humidity Range | 15–95% RH |
| Detection Limit | <100 ppt (gas), <150 ng/L (liquid) |
| Calibration Options | Automated gas-phase calibration (integrated permeation tube generator), semi-automated liquid-phase standard injection |
| Data Storage | USB flash drive (8 GB) |
| Interface | RS232 |
| Dimensions (W×H×D) | 45 × 15 × 56 cm |
| Mounting | 19″ rack-compatible |
| Power Supply | 110/220 VAC, 110 W (24 VDC optional) |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL5001 |
| Detection Principle | Vacuum Ultraviolet Fluorescence (VUV) at 150 nm |
| Detection Limit | <2.0 ppb (1 s integration), <0.8 ppb (10 s integration) |
| Response Time (10–90%) | 2 s |
| Linear Range | 0–100 ppm (pulse counting mode) |
| Pump Type | Diaphragm vacuum pump |
| Interface | RS232 |
| Power Supply | 110/220 VAC or 24 VDC |
| Weight | 22 kg |
| Automation | Fully automated measurement and calibration |
| Brand | Aero Laser |
|---|---|
| Origin | Germany |
| Model | AL5001 |
| Detection Principle | Vacuum Ultraviolet Fluorescence (VUV-F) at 150 nm |
| Detection Limit | <0.8 ppb (10 s integration) |
| Linear Range | 0–100 ppm (pulse counting mode) |
| Response Time (10–90%) | 2 s |
| Pump Type | Diaphragm Vacuum Pump |
| Interface | RS232 |
| Power Supply | 110/220 VAC or 24 VDC |
| Weight | 22 kg |
| Automation | Fully Automated Zero/Span Calibration |
| Application Scope | Ultra-trace CO monitoring in ambient air, cleanrooms, high-purity specialty gas streams, and remote atmospheric research stations |