| Brand | Axcend |
|---|---|
| Origin | USA |
| Model | Focus LC |
| Instrument Type | Portable Capillary HPLC |
| Detection Principle | UV Absorbance (254 nm standard) |
| Max Operating Pressure | 10,000 psi |
| Power Input | AC 100–240 V, 50/60 Hz, 1.4 A |
| Battery | 12 V DC, 126 Wh LiFePO₄ |
| Runtime | >10 hours per charge |
| Cycle Life | >2,000 charge/discharge cycles |
| Solvent Consumption | <10 mL/week (typical operational use) |
| Cartridge-Based System | Tool-free, modular hardware reconfiguration |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | ATS 200S/40998 |
| Measurement Principle | Atomic Emission Spectrometry (Flame Photometry) |
| Elements Measured (Standard) | Na, K, Ca, Mg |
| Optional Channels | Ba or custom single-element channel |
| Measurement Units | ppm, mmol/L, mEq/L |
| Linear Range | Na/K/Ca 0–200 ppm |
| Detection Limit | 0.2 ppm (Na, K) |
| Sensitivity | 0.4 ppm (Na, K) |
| Precision | ≤1% CV (n=10) |
| Drift | ≤1% over 30 min |
| Fuel Gases | Butane, Propane, LPG |
| Air Supply | Oil-free, water-free, particle-free compressed air with buffer tank |
| Optical Design | Fixed interference filters (non-movable) |
| Calibration | Automatic zeroing + single-point memory calibration |
| Software | ATS MiniSoftWin™ (GLP-compliant reporting, multi-point calibration curve generation, method/data archiving, ISO/IEC 17025 report templates) |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | 300GM |
| Spectral Dispersion | Grating and Interference Filters |
| Slit Width (Spectral Bandpass) | 1.5 nm |
| Resolution | 1 nm |
| Sensitivity | 200:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±2 nm |
| Detection Range | 1–800 ppm U |
| Precision | ≤1% CV at 100 ppb U |
| Measurement Cycle Time | 5 s |
| Display | Backlit LCD/LED |
| Interface | RS-232, USB 2.0 |
| Power Supply | ATS/37009: 230 VAC, 50/60 Hz |
| ATS/37010 | 110 VAC, 60 Hz |
| Dimensions | 420 × 280 × 380 mm (L×W×H) |
| Net Weight | 9 kg |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | ATS 200S |
| Detection Elements | Na, K, Li, Ca (standard) |
| Measurement Range | Na/K/Li/Ca: 0–200 ppm |
| Ba | 50–1000 ppm |
| Units | ppm, mmol/L, mEq/L |
| Sensitivity | 0.4 ppm (Na, K) |
| Detection Limit | 0.2 ppm (Na, K) |
| Linearity | Natural logarithmic linearity (R² > 0.999 over full range) |
| Repeatability | ≤1% CV (n=10) |
| Drift | ≤1% over 30 min |
| Calibration | One-touch auto-zero and multi-point calibration |
| Operating Temperature | 15–36 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Dimensions (Analyzer) | 320 × 400 × 400 mm (L×W×H) |
| Net Weight (Analyzer) | 9 kg |
| Air Compressor Dimensions | 340 × 250 × 350 mm |
| Net Weight (Compressor) | 6 kg |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Software Interface | USB 2.0, RS-232, optional Ethernet module |
| Brand | -- |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TEA4000 |
| Pricing | Upon Request |
| Brand | SMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ABL |
| Pricing | Available Upon Request |