Empowering Scientific Discovery

Beijing Jinhengxiang Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAxcend
OriginUSA
ModelFocus LC
Instrument TypePortable Capillary HPLC
Detection PrincipleUV Absorbance (254 nm standard)
Max Operating Pressure10,000 psi
Power InputAC 100–240 V, 50/60 Hz, 1.4 A
Battery12 V DC, 126 Wh LiFePO₄
Runtime>10 hours per charge
Cycle Life>2,000 charge/discharge cycles
Solvent Consumption<10 mL/week (typical operational use)
Cartridge-Based SystemTool-free, modular hardware reconfiguration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATS
OriginSwitzerland
ModelATS 200S/40998
Measurement PrincipleAtomic Emission Spectrometry (Flame Photometry)
Elements Measured (Standard)Na, K, Ca, Mg
Optional ChannelsBa or custom single-element channel
Measurement Unitsppm, mmol/L, mEq/L
Linear RangeNa/K/Ca 0–200 ppm
Detection Limit0.2 ppm (Na, K)
Sensitivity0.4 ppm (Na, K)
Precision≤1% CV (n=10)
Drift≤1% over 30 min
Fuel GasesButane, Propane, LPG
Air SupplyOil-free, water-free, particle-free compressed air with buffer tank
Optical DesignFixed interference filters (non-movable)
CalibrationAutomatic zeroing + single-point memory calibration
SoftwareATS MiniSoftWin™ (GLP-compliant reporting, multi-point calibration curve generation, method/data archiving, ISO/IEC 17025 report templates)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATS
OriginSwitzerland
Model300GM
Spectral DispersionGrating and Interference Filters
Slit Width (Spectral Bandpass)1.5 nm
Resolution1 nm
Sensitivity200:1 (Signal-to-Noise Ratio)
Wavelength Accuracy±2 nm
Detection Range1–800 ppm U
Precision≤1% CV at 100 ppb U
Measurement Cycle Time5 s
DisplayBacklit LCD/LED
InterfaceRS-232, USB 2.0
Power SupplyATS/37009: 230 VAC, 50/60 Hz
ATS/37010110 VAC, 60 Hz
Dimensions420 × 280 × 380 mm (L×W×H)
Net Weight9 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandATS
OriginSwitzerland
ModelATS 200S
Detection ElementsNa, K, Li, Ca (standard)
Measurement RangeNa/K/Li/Ca: 0–200 ppm
Ba50–1000 ppm
Unitsppm, mmol/L, mEq/L
Sensitivity0.4 ppm (Na, K)
Detection Limit0.2 ppm (Na, K)
LinearityNatural logarithmic linearity (R² > 0.999 over full range)
Repeatability≤1% CV (n=10)
Drift≤1% over 30 min
CalibrationOne-touch auto-zero and multi-point calibration
Operating Temperature15–36 °C
Relative Humidity≤85% RH (non-condensing)
Dimensions (Analyzer)320 × 400 × 400 mm (L×W×H)
Net Weight (Analyzer)9 kg
Air Compressor Dimensions340 × 250 × 350 mm
Net Weight (Compressor)6 kg
ComplianceCE, RoHS, ISO/IEC 17025-compatible operation
Software InterfaceUSB 2.0, RS-232, optional Ethernet module
Added to wishlistRemoved from wishlist 0
Add to compare
Brand--
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTEA4000
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSMS
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelABL
PricingAvailable Upon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0