BrandBCC
OriginHebei, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelMGA-6000
Sampling MethodExtractive
Power Supply220 V AC
Explosion ProtectionEx d IIB T4
Ingress ProtectionIP65
Detection PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Target AnalytesEthyl Mercaptan, Tetrahydrothiophene (THT), Acrylic Ester
Measurement Range0–100 ppm
Response Time (T90)≤60 s
Accuracy±1 ppm or ±1% of reading (whichever is greater)
Zero/ Span Drift≤±1% FS / 24 h
Output Interfaces4–20 mA, RS-232 / RS-485, USB, Ethernet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA-3000P (Ammonia-Specific)
PrincipleNon-Dispersive Infrared (NDIR) Absorption
TypePortable Multicomponent Gas Analyzer
Measurement Range1 ppb to 100% vol NH₃ (customizable)
Sensitivity1 ppb (NH₃)
Response TimeT₉₀ ≤ 20 s
Repeatability±1–2% FS
Zero/ Span Drift≤ ±1% FS / 24 h
Power Consumption< 100 W
Output Interfaces4–20 mA, RS232 / RS485, USB, Ethernet (TCP/IP)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA6000
PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
TypeFixed-mount analyzer
Measurement Range0–1000 ppm H₂O
Limit of Detection (LOD)10 ppb H₂O
Response Time (T90)≤20 s
Repeatability≤±1% FS
Output InterfacesRS-485, Ethernet (TCP/IP)
Data StorageEmbedded SSD (5-year capacity)
DesignModular, maintenance-free architecture
ComplianceDesigned for continuous industrial process monitoring per ISO 8573-3 and ASTM D7217
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
ModelMGA-6000
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Detection Range0–1 ppm to 0–100% (selectable, multi-range auto-switching)
Sensitivity1 ppb (gas-dependent)
Response TimeT90 ≤ 20 s
Repeatability≤ ±1% FS
Zero/Scale Drift≤ ±1% FS / 24 h
Operating Temperature StabilityActive thermal control with proprietary temperature management
Enclosure Options19" rack-mount, benchtop, and portable configurations
Data Interfaces4–20 mA analog output, RS232 / RS485 serial, USB, Ethernet (TCP/IP)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelKPV-2000
Instrument TypeContinuous Emission Monitoring System (CEMS)
Measurement ParametersTemperature, Pressure, Velocity
Temperature Range0–500 °C (customizable up to 1100 °C)
Pressure Range−8 to +8 kPa
Velocity Range5–40 m/s
Measurement MethodsPt100 resistance thermometer (temperature), piezoresistive pressure transducer (pressure), Pitot tube differential pressure method (velocity)
Accuracy±2% relative error
Power Consumption< 0.04 kVA
Output Signal4–20 mA analog
Environmental RatingRated for continuous operation at ambient housing temperatures up to 1100 °C
Additional FeatureIntegrated automatic purge system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA-3000
Detection PrincipleNon-Dispersive Infrared (NDIR) Spectroscopy
Target AnalytesEthyl Mercaptan, Tetrahydrothiophene (THT), Acrylic Ester
Measurement Range0–100 ppm
Accuracy±1 ppm or ±2% of reading (whichever is greater)
Zero/ Span Drift≤±2% FS/24 h
Response Time (T90)≤90 s
Sampling MethodExtractive
Output Interfaces4–20 mA, RS-232 / RS-485, USB, Ethernet
Enclosure RatingIP65
Explosion ProtectionEx d IIB T4 Gb
Power Supply220 V AC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA-3000Ex
PrincipleNon-Dispersive Infrared (NDIR) Absorption
TypeFixed-Mount Industrial Analyzer
Detection Range1 ppb to 100% vol
Sensitivity1 ppb (for select gases)
Response TimeT90 ≤ 60 s
Repeatability≤ ±1% FS
Accuracy±0.1–2% FS (gas-dependent)
Zero/Full-Scale Auto-CalibrationYes
Drift≤ ±1% FS / 24 h
Output Interfaces4–20 mA, RS232/RS485, USB, Ethernet (TCP/IP)
Enclosure Options19" rack-mount, benchtop
Certified ProtectionEx d IIB T4 Gb / Ex tb IIIC T130°C Db (IEC 60079-0, -1, -7, -31)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
ModelMGA-3000P
PrincipleNon-Dispersive Infrared (NDIR) Absorption
TypePortable
Detection Range0.1 ppm to 100% vol
Sensitivity0.01 ppm
Response Time (T90)≤30 s
Repeatability±1–2% FS
Zero/ Span Drift≤±1% FS / 24 h
Detection Limits0.1–1 ppm (gas-dependent)
Power Consumption<100 W
Data Interfaces4–20 mA, RS232/RS485, USB, Ethernet
Sample HandlingDual-mode (cold-dry and hot-wet)
Gas SelectivityEnhanced via Gas Correlation Filtering (GCF)
Simultaneous ChannelsUp to 7 gas components
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelKSP-L-1000 (Extractive)
Measurement PrincipleLaser Light Scattering
Safety RatingNon-Explosive
Measurement Range0–5–200 mg/m³
Resolution0.01 mg/m³
Accuracy±2% FS
Relative Error≤±2% FS
Zero Drift≤±2% FS/24h
Span Drift≤±2% FS/24h
Detection Limit0.01 mg/m³
Sampling Flow RateUp to 250 L/min
Heating TemperatureFull-Path Heated Sampling Line (Typical Setpoint: 120–180°C)
CalibrationAutomated Zero & Span Calibration
Carrier GasIntegrated Air Pump (Frost-Resistant Design)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA-6000P
PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
TypePortable
Detection Rangeppb to 100% (gas-dependent)
Sensitivity1 ppb
Response Time (T90)≤20 s
Repeatability1–2% FS
Drift≤±1% / 24 h
Power Consumption<100 W
Detection Limits1 ppb – 1 ppm (varies by target gas)
Data Interfaces4–20 mA, RS232/RS485, USB, Ethernet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelBKS-3000
Instrument TypeFlue Gas CEMS
Accuracy≤±1% FS/24h
Repeatability≤±1% FS/24h
Response Time≤10 s
Stability (Zero/Scale Drift)≤±1% FS/24h (gaseous), negligible drift (particulate)
Measured ParametersSO₂, NOₓ (NO, NO₂, N₂O), CO, CO₂, SO₃, CH₄, O₂, HCl, NH₃, HF, H₂S, H₂O, particulate matter (PM)
Detection MethodsNon-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), UV Differential Optical Absorption Spectroscopy (UV-DOAS), Electrochemical (O₂), Optical Scattering (PM)
Output InterfacesRS232, RS485, 4–20 mA, Ethernet, 4G/5G cellular
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA-6000Ex
PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
TypeFixed-mount
Detection Rangeppb to 100% vol
Sensitivity1 ppb
Response TimeT90 ≤ 20 s
Repeatability≤ ±1% FS
Accuracy0.1–2% FS
Drift≤ ±1% FS / 24 h
Output Interfaces4–20 mA, RS232/RS485, USB, Ethernet (TCP/IP)
Auto-CalibrationZero & Span
Certified ProtectionEx d IIB T4 Gb / Ex tb IIIC T130°C Db (IEC 60079-0, -1, -7, -31)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
ModelMGA-3000
PrincipleNon-Dispersive Infrared (NDIR) Absorption
ConfigurationFixed-Mount
Detection Range0–10 / 50 / 100 / 500 / 1000 ppm to 100% vol (gas-dependent, customizable)
Sensitivity1 ppb
Response TimeT90 ≤ 60 s
Repeatability≤ ±1 % FS
Accuracy≤ ±2 % FS
Zero Drift≤ ±1 % FS / 24 h
Detection Limit0.1–1 ppm (varies by target gas)
Output Interfaces4–20 mA, RS232/RS485, USB, Ethernet
Enclosure Options19″ rack-mount, benchtop, portable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA6000
PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
TypeFixed-Installation Multicomponent Gas Analyzer
Measurement TargetH₂O vapor in gas streams
Detection Range0–10 / 50 / 100 / 500 / 1000 ppm up to % level (configurable)
Limit of Detection (LOD)10 ppb
Response Time (T90)≤20 s
Repeatability≤±1% FS
Output InterfacesRS-485, Ethernet (TCP/IP) for DCS integration
Data StorageEmbedded SSD with 5-year local retention
DesignModular, maintenance-free architecture
ConsumablesNone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
ModelMGA-8000
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS) with Off-Axis ICOS
Detection Range0–1 / 10 / 50 / 100 / 500 ppm (selectable per gas)
Detection Limit<1 ppb (gas-dependent)
Response Time (T90)≤20 s
Repeatability≤±0.1% FS
Drift≤±1% FS / 24 h
Temperature Control Stability±0.005 °C
Pressure Control Stability±0.0002 atm
Sample Temperature Range−10 to +50 °C
Output Interfaces4–20 mA, RS-232 / RS-485 (Modbus RTU), USB, Ethernet
Power Supply200–240 VAC, 50/60 Hz
Enclosure Options19″ rack-mount, benchtop, portable