Empowering Scientific Discovery

Beijing Kair Science & Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA-3000P (Ammonia-Specific)
PrincipleNon-Dispersive Infrared (NDIR) Absorption
TypePortable Multicomponent Gas Analyzer
Measurement Range1 ppb to 100% vol NH₃ (customizable)
Sensitivity1 ppb (NH₃)
Response TimeT₉₀ ≤ 20 s
Repeatability±1–2% FS
Zero/ Span Drift≤ ±1% FS / 24 h
Power Consumption< 100 W
Output Interfaces4–20 mA, RS232 / RS485, USB, Ethernet (TCP/IP)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA6000
PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
TypeFixed-mount analyzer
Measurement Range0–1000 ppm H₂O
Limit of Detection (LOD)10 ppb H₂O
Response Time (T90)≤20 s
Repeatability≤±1% FS
Output InterfacesRS-485, Ethernet (TCP/IP)
Data StorageEmbedded SSD (5-year capacity)
DesignModular, maintenance-free architecture
ComplianceDesigned for continuous industrial process monitoring per ISO 8573-3 and ASTM D7217
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
ModelMGA-6000
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
Detection Range0–1 ppm to 0–100% (selectable, multi-range auto-switching)
Sensitivity1 ppb (gas-dependent)
Response TimeT90 ≤ 20 s
Repeatability≤ ±1% FS
Zero/Scale Drift≤ ±1% FS / 24 h
Operating Temperature StabilityActive thermal control with proprietary temperature management
Enclosure Options19" rack-mount, benchtop, and portable configurations
Data Interfaces4–20 mA analog output, RS232 / RS485 serial, USB, Ethernet (TCP/IP)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA-3000Ex
PrincipleNon-Dispersive Infrared (NDIR) Absorption
TypeFixed-Mount Industrial Analyzer
Detection Range1 ppb to 100% vol
Sensitivity1 ppb (for select gases)
Response TimeT90 ≤ 60 s
Repeatability≤ ±1% FS
Accuracy±0.1–2% FS (gas-dependent)
Zero/Full-Scale Auto-CalibrationYes
Drift≤ ±1% FS / 24 h
Output Interfaces4–20 mA, RS232/RS485, USB, Ethernet (TCP/IP)
Enclosure Options19" rack-mount, benchtop
Certified ProtectionEx d IIB T4 Gb / Ex tb IIIC T130°C Db (IEC 60079-0, -1, -7, -31)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
ModelMGA-3000P
PrincipleNon-Dispersive Infrared (NDIR) Absorption
TypePortable
Detection Range0.1 ppm to 100% vol
Sensitivity0.01 ppm
Response Time (T90)≤30 s
Repeatability±1–2% FS
Zero/ Span Drift≤±1% FS / 24 h
Detection Limits0.1–1 ppm (gas-dependent)
Power Consumption<100 W
Data Interfaces4–20 mA, RS232/RS485, USB, Ethernet
Sample HandlingDual-mode (cold-dry and hot-wet)
Gas SelectivityEnhanced via Gas Correlation Filtering (GCF)
Simultaneous ChannelsUp to 7 gas components
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA-6000P
PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
TypePortable
Detection Rangeppb to 100% (gas-dependent)
Sensitivity1 ppb
Response Time (T90)≤20 s
Repeatability1–2% FS
Drift≤±1% / 24 h
Power Consumption<100 W
Detection Limits1 ppb – 1 ppm (varies by target gas)
Data Interfaces4–20 mA, RS232/RS485, USB, Ethernet
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA-6000Ex
PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
TypeFixed-mount
Detection Rangeppb to 100% vol
Sensitivity1 ppb
Response TimeT90 ≤ 20 s
Repeatability≤ ±1% FS
Accuracy0.1–2% FS
Drift≤ ±1% FS / 24 h
Output Interfaces4–20 mA, RS232/RS485, USB, Ethernet (TCP/IP)
Auto-CalibrationZero & Span
Certified ProtectionEx d IIB T4 Gb / Ex tb IIIC T130°C Db (IEC 60079-0, -1, -7, -31)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
ModelMGA-3000
PrincipleNon-Dispersive Infrared (NDIR) Absorption
ConfigurationFixed-Mount
Detection Range0–10 / 50 / 100 / 500 / 1000 ppm to 100% vol (gas-dependent, customizable)
Sensitivity1 ppb
Response TimeT90 ≤ 60 s
Repeatability≤ ±1 % FS
Accuracy≤ ±2 % FS
Zero Drift≤ ±1 % FS / 24 h
Detection Limit0.1–1 ppm (varies by target gas)
Output Interfaces4–20 mA, RS232/RS485, USB, Ethernet
Enclosure Options19″ rack-mount, benchtop, portable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
OriginHebei, China
ModelMGA6000
PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS)
TypeFixed-Installation Multicomponent Gas Analyzer
Measurement TargetH₂O vapor in gas streams
Detection Range0–10 / 50 / 100 / 500 / 1000 ppm up to % level (configurable)
Limit of Detection (LOD)10 ppb
Response Time (T90)≤20 s
Repeatability≤±1% FS
Output InterfacesRS-485, Ethernet (TCP/IP) for DCS integration
Data StorageEmbedded SSD with 5-year local retention
DesignModular, maintenance-free architecture
ConsumablesNone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBCC
ModelMGA-8000
Measurement PrincipleTunable Diode Laser Absorption Spectroscopy (TDLAS) with Off-Axis ICOS
Detection Range0–1 / 10 / 50 / 100 / 500 ppm (selectable per gas)
Detection Limit<1 ppb (gas-dependent)
Response Time (T90)≤20 s
Repeatability≤±0.1% FS
Drift≤±1% FS / 24 h
Temperature Control Stability±0.005 °C
Pressure Control Stability±0.0002 atm
Sample Temperature Range−10 to +50 °C
Output Interfaces4–20 mA, RS-232 / RS-485 (Modbus RTU), USB, Ethernet
Power Supply200–240 VAC, 50/60 Hz
Enclosure Options19″ rack-mount, benchtop, portable