| Output Flow | 0–5000 mL/min @ 0.4 MPa |
|---|---|
| Output Pressure | 0–0.4 MPa |
| Pressure Stability | < 0.003 MPa |
| Noise Level | < 35 dB(A) |
| Power Consumption | 275 W |
| Input Voltage | 220 V ±10% |
| Dimensions (W×D×H) | 480 × 260 × 350 mm |
| Net Weight | ~25 kg |
| Operating Environment | 0–45 °C, RH ≤85% (non-dusty, non-corrosive atmosphere) |
| Compliance | Designed for ISO/IEC 17025-compliant labs |
| Output Flow | 0–10 L/min @ 0.4 MPa |
|---|---|
| Output Pressure | 0–0.5 MPa (factory-set to 0.4 MPa) |
| Pressure Stability | < 0.003 MPa |
| Power Consumption | 550 W |
| Dimensions (W×H×D) | 380 × 570 × 400 mm |
| Net Weight | ~38 kg |
| Compressor Type | Oil-Free Diaphragm |
| Noise Level | ≤52 dB(A) |
| Internal Sealing Material | Low-Sulfur Silicone Rubber |
| Gas Purity | Hydrocarbon-free, Oil-free, Particulate-free (< 0.01 µm), Dew Point ≤ −40 °C @ 0.4 MPa |
| Output Flow | 0–8000 mL/min @ 0.4 MPa |
|---|---|
| Output Pressure | 0–0.4 MPa |
| Pressure Stability | < 0.003 MPa |
| Noise Level | < 35 dB(A) |
| Power Consumption | 300 W |
| Input Voltage | 220 V ±10% |
| Dimensions (W×D×H) | 480 × 260 × 350 mm |
| Net Weight | ~25 kg |
| Operating Environment | 0–45 °C, RH ≤85% (non-dusty, non-corrosive atmosphere) |
| Compliance | Designed for ISO/IEC 17025-compliant labs and GLP/GMP environments |
| Output Flow | 0–2000 mL/min @ 0.4 MPa |
|---|---|
| Output Pressure | 0–0.4 MPa |
| Pressure Stability | < 0.003 MPa |
| Noise Level | < 35 dB(A) |
| Power Consumption | 175 W |
| Input Voltage | 220 V ±10% |
| Dimensions (W×D×H) | 400 × 180 × 250 mm |
| Net Weight | ~15 kg |
| Operating Environment | 0–45 °C, RH ≤85% (non-condensing, dust-free, non-corrosive atmosphere) |
| Compliance | Designed for GLP-compliant laboratory environments |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZA-1000 |
| Price | Upon Request |
| Output Hydrocarbon (as CH₄) | <0.1 ppm |
| Max. Input Hydrocarbon (as CH₄) | <100 ppm |
| Max. Input Pressure | 0–0.6 MPa |
| Max. Output Flow Rate | 1000 mL/min |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Power Consumption | 200 W |
| Catalyst Operating Temperature | 450–500 °C (factory-set at 450 °C) |
| Ambient Operating Temperature | 0–40 °C |
| Ambient Relative Humidity | <85 % RH |
| Dimensions (W×D×H) | 400 × 360 × 220 mm |
| Net Weight | ~12 kg |
| Output Flow | 0–2000 mL/min @ 0.4 MPa |
|---|---|
| Output Pressure | 0–0.4 MPa |
| Pressure Stability | < 0.003 MPa |
| Noise Level | < 35 dB(A) |
| Power Consumption | 175 W |
| Input Voltage | 220 V ±10% |
| Dimensions (W×D×H) | 420 × 260 × 350 mm |
| Net Weight | 22 kg |
| Operating Environment | 0–45 °C, RH ≤85% (non-dusty, non-corrosive atmosphere) |
| Filtration | Dual stainless steel filters + stainless steel air reservoir |
| Sealing Material | Low-sulfur silicone O-rings |