Empowering Scientific Discovery

Beijing Luda Hengyu Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRestek
ModelGC-Specific Thermal Conductivity Gas Leak Detector
Detection PrincipleThermal Conductivity Differential Sensing
Detectable GasesHe, H₂, N₂, Ar, CO₂
Minimum Detectable Leak Rate1.0 × 10⁻⁶ atm·cc/sec (H₂), 1.0 × 10⁻⁵ atm·cc/sec (He), 1.0 × 10⁻⁴ atm·cc/sec (Ar/CO₂), 1.4 × 10⁻³ atm·cc/sec (N₂)
Response Time≤2 seconds
Power SupplyRechargeable NiMH battery (6 h typical operation) with low-battery and charging indicators
Operating Temperature0–48 °C (32–120 °F)
Relative Humidity0–97 % RH
Enclosure RatingCE, Ex (ATEX/IECEx compliant for non-incendive use), Japan PSE
ComplianceRoHS, WEEE
Auto-Zero FunctionOne-button activation
Probe DesignRuggedized, flexible-tip, cleanable, position-switch enabled
HousingErgonomic handheld chassis with side-grip reinforcement
Auto-ShutdownEnabled after 5 minutes of inactivity
Accessories IncludedHard-shell carrying case, universal AC adapter kit
Warranty1 year limited
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ModelG3388A
Detection PrincipleThermal Conductivity Differential Sensing
Response Time<1 s
Minimum Detectable Leak Rate0.01 mL/min (H₂/He)
Dimensions6.35 cm × 3.81 cm × 14.6 cm (2.5 in × 1.5 in × 5.75 in)
Weight310 g
Power SourceRechargeable NiMH Battery (5 h runtime)
ComplianceDesigned for use with Agilent GC systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ModelADM 1000
Accuracy±3% of reading or ±0.2 mL/min (whichever is greater)
Flow Range0.5–1000 mL/min
Operating Temperature (Instrument)0–45 °C
Operating Temperature (Line)–70 to 135 °C
CalibrationNIST-traceable 5-point calibration
Power Supply9 V battery
Gas CompatibilityClean, dry, non-corrosive gases
Output InterfaceNone (ADM 1000)
Measurement PrincipleVolumetric flow measurement via thermal dispersion sensing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRestek
ModelProFLOW 6000
OriginUSA
Flow Range0.5–500 mL/min
Accuracy±2% of reading or ±0.05 mL/min (whichever is greater)
Calibration TraceabilityNIST-traceable
Explosion ProtectionCertified for flammable and explosive gases (Ex-rated)
Operating Temperature0–48 °C
Relative Humidity0–97% RH (non-condensing)
Power Supply2 × AA batteries
Data InterfaceUSB
CertificationsCE, RoHS, WEEE
Enclosure OptionsHandheld and benchtop configurations
Auto-shutdownYes
Warranty1 year
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAgilent Technologies
OriginUSA
ModelADM 2000
Flow Range0.5–1000 mL/min
Accuracy±3% of reading or ±0.2 mL/min (whichever is greater)
Gas CompatibilityClean, dry, non-corrosive gases (e.g., N₂, H₂, He, Air, CO₂, CH₄, 95% Ar/CH₄)
Measurement TypeVolumetric flow with mass flow calculation
Output InterfaceRS-232
Power Supply9 V battery or 120/220 V AC adapter
ComplianceDesigned for laboratory-grade gas flow verification in GC systems
AccessoriesOptional carrying case (P/N 907-0056)
Part Number220-1171-U (120 V), 220-1171-E (220 V)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerkinElmer
OriginUSA
ModelFlowMark 1000
Flow Range0.1–1000 mL/min
Accuracy±3% of reading or ±0.05 mL/min (whichever is greater)
Operating Temperature0–45 °C
Calibration TraceabilityNIST-traceable
DisplayAlphanumeric LCD
Power Supply9 V battery (also compatible with 2 × AA batteries per variant specifications)
ComplianceCE, ATEX/IECEx Ex-certified (for hazardous areas), RoHS, WEEE
Gas CompatibilityClean, dry, non-corrosive, non-flammable gases only
Data InterfaceUSB port
Auto-power-offYes
EnclosureErgonomic handheld housing with side-grip design
Warranty1 year
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRestek
OriginUSA
ModelLD-229
Detection PrincipleThermal Conductivity (TCD-based)
Detectable GasesHe, H₂, Ar, Ne
Minimum Detectable Leak Rate0.01 mL/min (for He and H₂)
Power SourceRechargeable Ni-Cd battery (4 h charge time, 5 h typical operation, up to 9 h with fresh fully charged battery)
Operating Temperature10–35 °C
Dimensions65 mm (W) × 37 mm (D) × 143 mm (H)
Probe Length85 cm
Net Weight330 g
DisplayLCD with real-time status indication
AlarmDual-mode — visual (LED) and audible (variable-tone buzzer)
ComplianceDesigned for laboratory and industrial leak-checking in accordance with ASTM E1715 and ISO 10012-based verification practices
AccessoriesEU-type AC adapter (220 V), replaceable particulate filter (P/N 2702-19395)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing
Manufacturer TypeDistributor
Origin CategoryDomestic (China)
Model100 mL/min Full-Scale
PricingUpon Request