Empowering Scientific Discovery

Beijing NiuYin Huaxin Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNeuronBC
OriginBeijing, China
ModelTA-2.0
Instrument TypeOnline TOC Analyzer
Detection PrincipleDirect Conductivity Method
Oxidation MethodUV Photolysis (185/254 nm)
Measurement Range1–1000 ppb (as C)
Accuracy±4% of reading
Resolution1 ppb
Detection Limit1 ppb
Repeatability≤3% RSD
Conductivity Range0.055–8.000 µS/cm
Sample Temp.1–95 °C
Ambient Temp.5–65 °C
Power100–240 VAC, 50 Hz, 120 W
Dimensions (L×W×H)400 × 240 × 270 mm
Weight8.5 kg
ComplianceUSP <643>, EP 2.2.44, FDA 21 CFR Part 11 (Audit Trail & User Authentication), GLP/GMP-ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNeuronbc
OriginBeijing, China
ModelRIT-1000
ComplianceFDA 21 CFR Part 11, EU Annex 11, GAMP 5
Test PrinciplePressure Decay Method
Port CompatibilityUniversal RTP interface (ISO 14644-3 compliant flange dimensions)
Sensitivity≤0.1 Pa/s pressure decay detection threshold
Operating EnvironmentISO Class C/D cleanrooms
Form FactorPortable benchtop unit with integrated pressure sensor and vacuum pump
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNeuronBC
ModelFPOSM-V2.0
Measurement PrincipleFreezing Point Depression (based on Raoult’s Law)
Measurement Range0–2000 mOsmol/kg
Sample Volume100 µL
Analysis Time≤3 min
Pre-cooling Time≤3 min
Accuracy≤±1%
Repeatability≤±1%
Linearity≤±1%
Operating Temperature0–30 °C (recommended 15–25 °C)
Relative Humidity≤60% RH
Power Supply220 V AC, 50 Hz, 150 VA
Dimensions225 × 275 × 345 mm
Weight15 kg
ComplianceDesigned to support 21 CFR Part 11-compliant data integrity requirements (electronic signatures, user-level access control, audit-trail-ready data storage)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelGT-2.0
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNeuronBC
OriginBeijing, China
ModelGT-5.0
Power SupplyAC 220 V, 50 Hz
Rated Power120 W
Test Duration2–8 min
Pressure Range500–5000 Pa
Pressure Resolution≤50 Pa
Operating Noise≤50 dB(A)
Maximum Seal Pressure≤0.8 MPa
Data Storage Capacity≥10,000 test records
Gas SupplyCompressed air, nitrogen, or inert gas
Tray ConfigurationUp to 6 glove trays (customizable)
ComplianceDesigned per GB/T 25915.7–2010 / ISO 14644-7:2004
Regulatory Alignment21 CFR Part 11–ready (electronic signatures, audit trail, user access control)
Optional FeaturesUSB data export, audit trail module, backup data archiving
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0