- All
- Favorite
- Popular
- Most rated
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-2.0 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±4% of reading |
| Resolution | 1 ppb |
| Detection Limit | 1 ppb |
| Repeatability | ≤3% RSD |
| Conductivity Range | 0.055–8.000 µS/cm |
| Sample Temp. | 1–95 °C |
| Ambient Temp. | 5–65 °C |
| Power | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Compliance | USP <643>, EP 2.2.44, FDA 21 CFR Part 11 (Audit Trail & User Authentication), GLP/GMP-ready |
| Brand | Neuronbc |
|---|---|
| Origin | Beijing, China |
| Model | RIT-1000 |
| Compliance | FDA 21 CFR Part 11, EU Annex 11, GAMP 5 |
| Test Principle | Pressure Decay Method |
| Port Compatibility | Universal RTP interface (ISO 14644-3 compliant flange dimensions) |
| Sensitivity | ≤0.1 Pa/s pressure decay detection threshold |
| Operating Environment | ISO Class C/D cleanrooms |
| Form Factor | Portable benchtop unit with integrated pressure sensor and vacuum pump |
| Brand | NeuronBC |
|---|---|
| Model | FPOSM-V2.0 |
| Measurement Principle | Freezing Point Depression (based on Raoult’s Law) |
| Measurement Range | 0–2000 mOsmol/kg |
| Sample Volume | 100 µL |
| Analysis Time | ≤3 min |
| Pre-cooling Time | ≤3 min |
| Accuracy | ≤±1% |
| Repeatability | ≤±1% |
| Linearity | ≤±1% |
| Operating Temperature | 0–30 °C (recommended 15–25 °C) |
| Relative Humidity | ≤60% RH |
| Power Supply | 220 V AC, 50 Hz, 150 VA |
| Dimensions | 225 × 275 × 345 mm |
| Weight | 15 kg |
| Compliance | Designed to support 21 CFR Part 11-compliant data integrity requirements (electronic signatures, user-level access control, audit-trail-ready data storage) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GT-2.0 |
| Pricing | Available Upon Request |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | GT-5.0 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 500–5000 Pa |
| Pressure Resolution | ≤50 Pa |
| Operating Noise | ≤50 dB(A) |
| Maximum Seal Pressure | ≤0.8 MPa |
| Data Storage Capacity | ≥10,000 test records |
| Gas Supply | Compressed air, nitrogen, or inert gas |
| Tray Configuration | Up to 6 glove trays (customizable) |
| Compliance | Designed per GB/T 25915.7–2010 / ISO 14644-7:2004 |
| Regulatory Alignment | 21 CFR Part 11–ready (electronic signatures, audit trail, user access control) |
| Optional Features | USB data export, audit trail module, backup data archiving |