| Brand | NeuronBC |
|---|---|
| Model | V6.5 |
| Origin | Beijing, China |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (mm) | 400 (D) × 240 (W) × 270/220 (H1/H2) |
| Weight | 8 kg |
| Bubble Point Accuracy | ±50 mbar |
| Diffusive Flow Accuracy | ±4% |
| Water Intrusion Accuracy | ±0.01 mL |
| Net Volume Test Accuracy | ±4% |
| Bubble Point Range | 100–8,000 mbar |
| Diffusive Flow Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Pre-stored Protocols | 80 |
| Event Log Capacity | ≥16 auditable events with timestamped traceability |
| User Access Levels | 4-tier role-based authentication with electronic signature support |
| Data Storage | ≥5,000 test records, USB backup of full datasets including real-time curves |
| Display | 7" high-resolution color touchscreen |
| Interface Options | RS232, USB, optional industrial fieldbus (e.g., Modbus TCP, Profibus DP) and analog I/O |
| Language Support | English / Chinese |
| Compliance | FDA 21 CFR Part 11, ALCOA+ principles, Annex 11 (EU GMP), ISO 13408-2, ASTM F838, USP <1207> |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | 20-Position |
| Instrument Type | Gas Chromatography & TOC Analyzer Autosampler |
| Maximum Sample Capacity | 20 vials |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volume | 100 µL |
| Positioning Accuracy | < 0.3 mm |
| Motion Control | Motorized XYZ Stage |
| Needle Wash Cycles | Unlimited |
| Replicate Injection Capability | Unlimited |
| Brand | NeuronBC |
|---|---|
| Model | BGT-100 |
| Origin | Beijing, China |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 0–5000 Pa |
| Pressure Resolution | 0.1 Pa |
| Response Threshold | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Dimensions | 370 × 220 × 210 mm |
| Weight | 4.5 kg |
| Data Storage Capacity | ≥10,000 test records |
| External Gas Source | Compressed air, nitrogen, or inert gas (≤0.5 MPa inlet pressure) |
| Audit Trail | Optional |
| Printer | Integrated thermal printer |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Benchtop Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photocatalytic Oxidation (254 nm) |
| Measurement Range | 0.001–1.0 mg/L (1–1000 ppb) |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ±3% RSD |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Dimensions (L×W×H) | 400 × 240 × 270 mm |
| Weight | 8.5 kg |
| Sample Temperature Range | 1–99 °C |
| Audit Trail | 16-event log with timestamped entries |
| User Access Control | 4-tier role-based authentication |
| Data Export | USB flash drive support |
| Data Storage Capacity | >5000 test records |
| Display | Color capacitive touchscreen |
| Compliance | Meets Chinese Pharmacopoeia 2020 Edition (ChP) General Chapter <0682>, FDA 21 CFR Part 11 (electronic records & signatures), and GLP/GMP-aligned validation protocols (IQ/OQ/PQ support available) |
| Brand | NeuronBC |
|---|---|
| Model | NBTB |
| Material | Sintered Titanium Powder |
| Filtration Accuracy | 1–50 µm (standard options: 1, 2, 3, 5, 10, 15, 30, 50 µm) |
| Porosity | 35–45% |
| Air Permeability Coefficient | 5×10⁻⁷ – 1×10⁻⁴ L/cm²·min·Pa |
| Minimum Burst Strength | ≥4 MPa |
| End Cap Configurations | Threaded, 222, 226, Flat-Plate |
| Outer Diameter | 30–80 mm |
| Length | 5", 10", 20", 30", 40" |
| Origin | Beijing, China |
| Regulatory Compliance | Designed for USP <788>, ISO 4074, and GMP-compliant bioprocessing environments |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | NeuronBC GT-2.0 Online |
| Power Supply | 100–220 VAC, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 500–5000 Pa |
| Pressure Resolution | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Operating Mode | Continuous |
| External Gas Source | Compressed air, nitrogen, or inert gas (max. inlet pressure ≤0.5 MPa) |
| Seal Pressure Capacity | ≤0.8 MPa |
| Data Storage Capacity | ≥10,000 test records |
| Dimensions | 400 × 260 × 250 mm |
| Weight | 7.5 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME2 |
| Price | USD 198,000 (FOB) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V8.0 |
| Operating Pressure Range | 100–10,000 mbar (150 psi) |
| Pressure Units | mbar, kPa, psi, kgf/cm² |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Enclosure Rating | IP54 |
| Dimensions (L×W×H) | 480 × 300 × 190 mm |
| Weight | 10 kg |
| Compliance | CE Marked, FDA 21 CFR Part 11, GMP-Aligned Audit Trail & Electronic Signature Support |
| Display | 10-inch true-color touchscreen |
| Data Export | USB (raw test data, configuration files, audit logs) |
| Connectivity | RS232, USB |
| Sensor Accuracy | High-precision pressure transducers with low drift and extended pneumatic line compensation up to 100 m |
| Integrated Thermal Printer | Non-ink, particle-free, archival-grade print retention (>10 years) |
| User Management | Four-tier role-based access control with customizable permissions, mandatory electronic signatures, and password-protected login |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TA-1.0 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 1–1000 µg/L (ppb) |
| Accuracy | ±3% of reading |
| Detection Limit | 1 µg/L |
| Resolution | 1 µg/L |
| Repeatability | ≤3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | <5 minutes per sample |
| Display | Color TFT Touchscreen |
| Power Supply | 220 V AC |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Variants | BLCC03 (3-Channel), BLCC06 (6-Channel) |
| Price Range | USD 2,800 – 7,000 |
| Material | 316 Stainless Steel |
| Connection to Filter Units | #8 Rubber Stopper |
| Connection to Vacuum Flask | Φ6 mm Silicone Tubing |
| Sterilization | Autoclavable at 121°C for 30 min |
| Dimensions (BLCC03) | 400 × 150 × 160 mm |
| Weight (BLCC03) | 8.0 kg |
| Dimensions (BLCC06) | 820 × 150 × 160 mm |
| Weight (BLCC06) | 12.0 kg |
| Packaging | 1 set per carton |
| Brand | NeuronBC |
|---|---|
| Model | GT-2.0 |
| Type | Online & Offline Glove Integrity Tester |
| Compliance | GB/T 25915.7–2010 / ISO 14644-7:2004 |
| Power Supply | 100–220 VAC, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 500–5000 Pa |
| Pressure Resolution | ≤50 Pa |
| Operating Noise | ≤50 dB(A) |
| Max Seal Pressure | ≤0.8 MPa |
| Data Storage Capacity | ≥10,000 test records |
| Dimensions | 400 × 260 × 250 mm |
| Weight | 7.5 kg |
| External Gas Source | Compressed air, nitrogen, or inert gas |
| Mobility | Portable with rapid-connect fittings |
| Interface | Color touchscreen with time/date stamping |
| Regulatory Conformance | 21 CFR Part 11 (electronic records & signatures), audit trail, role-based access control |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GT-2.0 |
| Power Supply | 100–220 VAC, 50 Hz |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 500–5000 Pa |
| Response Threshold | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Operating Mode | Continuous |
| External Gas Source | Compressed Air, Nitrogen, or Inert Gas |
| Max Seal Pressure | ≤0.8 MPa |
| Data Storage Capacity | ≥10,000 test records |
| Dimensions | 400 × 260 × 250 mm |
| Weight | 7.5 kg |
| Brand | NeuronBC |
|---|---|
| Model | BGT-120 |
| Principle | Pressure Decay Method (ASTM F2095-01) |
| Power Supply | AC 220 V, 50 Hz with Li-ion backup |
| Rated Power | 120 W |
| Test Duration | 2–8 min |
| Pressure Range | 0–5000 Pa |
| Pressure Resolution | 0.1 Pa |
| Response Threshold | ≤50 Pa |
| Noise Level | ≤50 dB(A) |
| Data Storage Capacity | ≥10,000 test records |
| Dimensions | 370 × 220 × 210 mm |
| Weight | 4.5 kg |
| Audit Trail | Optional |
| Compliance | ASTM F2095-01, FDA 21 CFR Part 11 (electronic records & signatures), GMP-aligned validation support (IQ/OQ/PQ/SOP) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PES |
| Price Range | USD 140 – 1,400 (FOB) |
| Membrane Material | Hydrophilic, Asymmetric Sulfonated Polyethersulfone |
| Sterilization Compatibility | Steam-in-Place (SIP) & Autoclave (121°C, 30 min) |
| Max Operating Temperature | 90°C @ 0.20 MPa |
| Forward Pressure Differential | 0.40 MPa (25°C) |
| Reverse Pressure Differential | 0.21 MPa (25°C) |
| Endotoxin Level | <0.25 EU/mL |
| Extractables | <30 mg per 10-inch Φ69 mm cartridge |
| Biocompatibility | USP <88> Class VI In Vivo Reactivity Testing |
| Water Contact Safety | Compliant with GB/T 17219–2001 (Drinking Water Safety) |
| Brand | NeuronBC |
|---|---|
| Model | Carbon TA5.0 |
| Origin | Beijing, China |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis (Static UV Oxidation) |
| Measurement Range | 1–1000 ppb (as C) |
| Accuracy | ±5% of reading |
| Detection Limit | 1 ppb (as C) |
| Resolution | 0.1 ppb (display), 1 ppb (reporting) |
| Repeatability | ±5% RSD |
| Conductivity Detection Range | 0.055–6.000 µS/cm |
| Sample Temperature Range | 0–100 °C |
| Ambient Operating Temperature | 5–65 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Power Supply | 220 V ±10%, 50 Hz ±10% |
| Response Time | ≤5 min (t₉₀) |
| Drift | ±5% FS/24 h |
| Detector Unit Rated Power | 50 W per unit |
| Communication Interface | RS-485 (up to 48 nodes) |
| Display | 10-inch capacitive touchscreen HMI |
| Data Terminal | TOC-D500 central controller supporting up to 8 distributed TA5.0 sensor units |
| Sample Tubing | PTFE, 1 mm ID, fitted with Swagelok® 50-series quick-connect fittings |
| Data Storage | Internal SD card (≥8 GB), 10-year historical archive (1-min intervals) |
| Output | Real-time analog 4–20 mA, Modbus RTU/TCP, optional thermal printer integration |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | PG16300 |
| Price | USD 670 (FOB) |
| Filter Area | 63.5 cm² (Φ100 mm), 132.6 cm² (Φ150 mm), 243.2 cm² (Φ200 mm), 572.2 cm² (Φ300 mm) |
| Max Operating Pressure | 0.8 MPa |
| Sterilization | Autoclavable at 121°C for 30 min |
| Housing Material | ASTM A240 UNS S31603 (316L stainless steel) |
| Gasket Material | Medical-grade silicone rubber |
| Inlet/Outlet | Hygienic clamp-type quick-release fittings (DIN 11851 / ISO 2852 compliant) |
| Surface Finish | Electropolished to Ra ≤ 0.4 µm |
| Chemical Compatibility | Enhanced by PTFE-coated wetted surfaces |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | Integtest™ V4.0 Portable |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Operating Pressure Range | 100–6900 mbar |
| Pressure Resolution | ±1.0 mbar |
| Bubble Point Accuracy | ±75 mbar |
| Test Duration (Rapid Bubble Point) | 8 ± 2 min |
| Test Duration (Bubble Point Scan) | 20 ± 2 min |
| Ambient Operating Conditions | 5–35 °C, 10–80% RH |
| Display | Monochrome LCD, 73 × 39 mm with backlight |
| Data Storage | 20 test records |
| Print Output | Integrated Chinese-language thermal printer |
| Dimensions (W × D × H₁ × H₂) | 400 × 380 × 100 × 235 mm |
| Weight | Approx. 8.2 kg |
| Compliance | Designed to support FDA 21 CFR Part 11 readiness, USP <1207>, ISO 13408-2, and Annex 1 (2022) requirements for sterile filtration validation |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | WGT-1200 |
| Price | Upon Request |
| Power Supply | DC 12 V, 20 W |
| Built-in Battery | 12 V Li-ion |
| Detection Accuracy | Minimum Detectable Hole Size: 300 µm |
| Test Duration | 3–8 min |
| Pressure Range | 500–3000 Pa |
| Pressure Resolution | 0.1 Pa |
| Noise Level | ≤50 dB(A) |
| Communication | Wi-Fi |
| Air Source | Integrated Sanitary-Grade Diaphragm Pump |
| Maximum Seal Pressure | ≤200 kPa |
| Data Storage Capacity | >12,000 test records |
| Data Storage Medium | Onboard Flash Memory |
| Glove Identification | RFID or Manual Entry |
| Unit Weight | 4.2 kg |
| Max. Controlled Test Units per Controller | 10 |
| Operating Time | Up to 8 h continuous / >48 h standby |
| User Accounts | 120 max |
| Predefined Test Protocols | 120 max |
| Access Control | Four-Tier Role-Based Permissions |
| Software Compliance | FDA 21 CFR Part 11 (Electronic Records & Signatures), GMP Annex 11, ALCOA+ Principles |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | FIT-V4.0 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (115 psi) |
| Test Methods | Bubble Point, Diffusion Flow, Pressure Hold, Water Intrusion |
| Accuracy | Bubble Point ±50 mbar |
| Test Range | Bubble Point 590–6900 mbar |
| Display | 5.7″ TFT monochrome LCD with backlight |
| Data Storage | 500 test records |
| Connectivity | RS232 serial interface |
| Language | English / Chinese |
| Operating Environment | ISO Class B cleanroom compliant |
| Dimensions (W×D×H) | 240 × 400 × 270 mm (base) + 220 mm (top module) |
| Weight | 7.5 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | V1.2 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (max. 115 psi) |
| Bubble Point Accuracy | ±75 mbar |
| Diffusion Flow Accuracy | ±4% |
| Bubble Point Range | 590–6900 mbar |
| Diffusion Flow Range | 1–180 mL/min |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (L×W×H) | 400 × 240 × 270 mm (base) + 220 mm (height with display module) |
| Weight | 7.5 kg |
| Display | 3.2″ monochrome LCD |
| Data Storage | 20 test records |
| Language | Chinese only |
| Test Modes | Bubble Point (fully automated), Diffusion Flow (semi-automated), Hold Pressure (pressure decay) |
| Sample Compatibility | Symmetric & asymmetric membranes |
| Cleanroom Suitability | ISO Class B and above |
| Compliance | Designed to support execution of ASTM F838-22, USP <1207>, EP 2.6.27, and ISO 13408-2 integrity test protocols |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | MFT-1000 |
| Detection Principles | Vacuum Decay & Pressure Decay |
| Compliance | USP <1207>, ASTM F2338-22, FDA 21 CFR Part 11, GMP Annex 1 (2022), ISO 15378:2017 |
| Test Range | −0.1 to 1.0 MPa (selectable ranges) |
| Differential Pressure Sensor | ±2 kPa, accuracy ≤0.5% FS, resolution 0.1 Pa |
| Minimum Detectable Equivalent Orifice Diameter | 1–2 µm |
| Display | 10-inch color capacitive touchscreen |
| Power | AC 100–240 V, 50/60 Hz, ≤200 W |
| Enclosure Rating | IP54 |
| Data Retention | ≥10 years (audit trail + event logs) |
| User Management | 4-tier role-based access control with customizable permissions |
| Output Interfaces | 4–20 mA, RS485, Ethernet, USB, 12 V alarm |
| Data Export | Raw test data, metadata, configuration files via USB |
| Optional Connectivity | Wireless module (Wi-Fi/Bluetooth), OPC UA, MQTT support |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | TOC-TA-200 |
| Instrument Type | Laboratory TOC Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion |
| Measurement Range | 0–30,000 mg/L |
| Accuracy | ±3% |
| Detection Limit | 1 ppb |
| Resolution | 1 ppb |
| Repeatability | ±3% |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | PTFE |
| Filtration Rating (Liquid) | 0.22 µm & 0.45 µm |
| Filtration Rating (Gas) | 0.01 µm |
| Bubble Point | ≥ 0.08 MPa (95% IPA) |
| Diffusion Flow | ≤ 5.5 mL/min (60:40 IPA:Water at 0.064 MPa) |
| Gas Flow Rate (Hydrophobic, 0.01 µm) | ≥ 6 m³/min (ΔP = 0.015 MPa at 0.13 MPa inlet) |
| Water Flow Rate (Hydrophilic, 0.22 µm) | ≥ 6.89 L/min (ΔP = 0.01 MPa at 0.13 MPa inlet) |
| Max Operating Pressure (Forward) | 0.42 MPa @ 25°C |
| Max Reverse Pressure | 0.21 MPa @ 25°C |
| Max Service Temperature | 65°C @ 0.21 MPa (Standard), 95°C @ 0.1 MPa (High-Temp Grade) |
| Sterilization | 142°C @ 0.276 MPa (Autoclave) |
| Online Steam | 135°C @ 0.1 MPa, 30 min per cycle (up to 160 cycles) |
| Max ΔP for Replacement | 0.20 MPa |
| Housing Material | Polypropylene (PP) |
| Core Support | PP, 304 SS, or 316 SS |
| End Cap & Connector | PP |
| Support Layer | Imported Polyester Nonwoven |
| Seal Materials | Food-Grade EPDM, Silicone, or FKM |
| Effective Filtration Area | 0.70 m² (10-inch format) |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | V6.5 Audit-Trail |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar |
| Temperature Range | +5°C to +40°C |
| Relative Humidity | 10–80% |
| Dimensions (mm) | 400(D) × 240(W) × 270(H1) × 220(H2) |
| Weight | 8 kg |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Water Intrusion Accuracy | ±0.01 mL |
| Bubble Point Range | 100–8,000 mbar |
| Diffusion Flow Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Pre-stored Protocols | 80 |
| Event Log Capacity | ≥16 auditable parameters with timestamp |
| User Access Levels | 4-tier role-based authentication with electronic signature support |
| Compliance | Fully aligned with FDA 21 CFR Part 11, ALCOA+ data integrity principles, and ISO 13485 / ASTM F838-22 / USP <1207> guidance for filter integrity testing |