Biochemical Analyzer
Filter
Showing all 13 results
| Brand | Buide |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | BUI |
| Pricing | Available Upon Request |
| Brand | Hitachi |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | LABOSPECT 008α |
| Architecture | Discrete Analysis System |
| Sample Type | Whole Blood, Serum, Plasma |
| Reagent Compatibility | Hitachi-Approved Dedicated Reagents |
| Throughput | Up to 2,000 tests/hour per chemistry module |
| ISE Throughput | Up to 1,800 tests/hour |
| Module Independence | Yes |
| Maintenance Mode | Per-module shuttering and pause functionality |
| Software Interface | Touch-optimized GUI with real-time data navigation and multi-project reagent tracking |
| Brand | Kehua Bio (KHB) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZY-1200 |
| Instrument Type | High-throughput Fully Automated Analyzer (1000–2000 tests/hour) |
| Assay Speed | 800 photometric tests/hour (biochemistry), 400 tests/hour (optional ISE module) |
| Minimum Sample Volume | 1.0 µL (0.1 µL increment) |
| Minimum Reagent Volume | 10 µL |
| Minimum Reaction Volume | 90 µL |
| Sample Types | Serum, plasma, whole blood, urine (per reagent package insert) |
| Reagent Compatibility | Kehua Bio–branded IVD reagents only |
| Regulatory Status | NMPA-certified Class II IVD device for clinical use in China |
| Test Menu | ~80 assays available with CE-IVD–marked or NMPA-registered reagents |
| Brand | Kehua Bio (KHB) |
|---|---|
| Origin | Shanghai, China |
| Model | ZY-400 |
| Instrument Type | Low-speed fully automated analyzer (0–400 tests/h) |
| Sample Types | Whole blood, serum, plasma, urine (per reagent instructions) |
| Throughput | 400 photometric tests/h (biochemistry) |
| Cross-contamination rate | <0.08% |
| Sample volume range | 1.5–70 µL (0.1 µL increment) |
| Cuvette material | Permanent optical glass |
| Reaction temperature control | Dual-phase liquid-gas thermostatic system, maintained at 37 ± 0.1 °C with real-time display and over-limit alarm |
| Calibration methods | Linear (K-factor, 2-point/multi-point), nonlinear (spline, piecewise linear, exponential, logarithmic, 3P/4P/5P logistic) |
| Analytical methods | End-point (single/dual), kinetic (rate), fixed-time, ISE potentiometry |
| Reagent refrigeration | Semiconductor-cooled reagent tray |
| Reagent monitoring | Real-time residual volume tracking with estimated remaining test count |
| Interface | Bidirectional LIS/HIS connectivity via standard network protocols (TCP/IP, ASTM, HL7) |
| User management | Role-based access control with audit trail |
| Compliance | CNAS-accredited medical laboratory validation framework |
| Power management | 24-hour continuous operation with auto-sleep/wake cycle |
| Brand | Kehua Bio (KHB) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZY-680 |
| Instrument Class | Mid-Speed Fully Automated Analyzer (400–1,000 tests/h) |
| Assay Throughput | 680 photometric tests/h (biochemistry), 400 tests/h (ISE module, optional) |
| Sample Types | Serum, plasma, whole blood, urine (per reagent package insert) |
| Reagent Compatibility | Kehua Bio–branded reagents only |
| Wavelength Range | 340–800 nm |
| Optical System | Holographic flat-field concave grating + diode array transient detection |
| Temperature Control | Water-bath incubation at 37.0 ± 0.1 °C with real-time display and out-of-range alarm |
| Cleaning System | Multi-step warm-water cuvette washing, independent polished vortex stirrer, KHB-specific cleaning solution |
| Sample/Reagent Capacity | High-capacity sample and reagent carousels with priority emergency sample insertion, auto-dilution & retest |
| Reagent Cooling | Peltier-based refrigeration (2–8 °C) |
| Reagent Monitoring | Real-time residual volume tracking with test-count estimation |
| Cuvette Design | Optimized geometry with bottom-structured reagent vials for minimized dead volume |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Polaris c1000 |
| Price Range | USD 63,000 – 91,500 (based on EUR/USD exchange parity and typical export pricing) |
| Instrument Type | Mid-Speed Fully Automated Analyzer (400–1000 tests/hour) |
| Reagents | KHB-licensed reagents only |
| Sample Types | Serum, Plasma, Urine, Whole Blood, Cerebrospinal Fluid (CSF) |
| Throughput | Constant-speed 1000 tests/hour |
| ISE module | 600 tests/hour (optional) |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Polaris c2000 |
| Price Range | USD 95,000–136,000 (FOB) |
| Instrument Type | High-throughput Fully Automated Analyzer (1000–2000 tests/hour) |
| Reagents | KHB-licensed in vitro diagnostic reagents only |
| Sample Types | Serum, Plasma, Urine, Whole Blood, Cerebrospinal Fluid (CSF) |
| Throughput | Constant-speed mode: 2000 tests/hour |
| Stat Emergency (SE) mode | 600 tests/hour (optional) |
| Brand | Roche |
|---|---|
| Origin | Switzerland |
| Model | Cedex Bio / Cedex Bio HT |
| Principle | Continuous Flow (Channel-Based) Analysis |
| Reagents | Roche-Approved Only |
| Sample Type | Cell Culture Supernatant |
| Analyte Scope | Substrates, Metabolites, Products |
| Throughput | High (Cedex Bio HT), Standard (Cedex Bio) |
| Regulatory Context | Designed for GMP-aligned bioprocess monitoring and QC release testing |
| Brand | Selecta |
|---|---|
| Origin | Spain |
| Model | PhotometerS-2000 |
| Measurement Principle | Continuous Flow (Flow-Through Cuvette System) |
| Detection Reagents | Selecta-branded clinical reagent kits |
| Optical System | Dual-wavelength solid-state photodiode detector with 7 fixed interference filters (340, 405, 500, 546, 578, 620, 670 nm) |
| Bandwidth | 10 nm |
| Cuvette Volume | 30 µL |
| Absorbance Range | 0.000–2.500 ABS |
| Display Resolution | 0.001 ABS |
| Computational Resolution | 0.0001 ABS |
| Temperature Control | Peltier-heated sample holder (setpoints: 25 °C, 30 °C, 37 °C |
| Light Source | 6 V / 10 W tungsten-halogen lamp |
| Lamp Life-Saving Mode | Yes |
| Display | 640 × 240 pixel LCD, 256-color graphics |
| Data Interface | RS-232 serial port |
| Ambient Operating Conditions | 15–32 °C, ≤85% RH (non-condensing) |
| Internal Storage | Up to 134 assay methods, 1000 patient results |
| Preloaded Methods | 47 most common clinical assays (e.g., cholesterol, glucose, serum iron, LDH, AST, urea) |
| Curve Fitting Algorithms | Endpoint, Kinetic, Linear Regression, Multi-Point Calibration, Best-Fit Polynomial, Bichromatic Correction |
| Control Interface | Scroll wheel or external USB mouse |
| Dimensions (H×W×D) | 41.2 × 45.3 × 33 cm |
| Power Supply | 100–220 V AC, 50–60 Hz |
| Weight | 15 kg |
| Optional Accessory | BIO-BATH metal dry-block incubator (37 °C, 8-position, for 75 × 13 mm test tubes) |
| Brand | SOOHOW INSTRUMENT |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | STS-A200 |
| Pricing Range | USD 14,000–21,000 |
| Architecture | Discrete Analytical System |
| Instrument Class | Low-Speed Fully Automated (0–400 rpm equivalent throughput logic) |
| Sample Types | Whole Blood, Serum, Plasma, Urine, Cerebrospinal Fluid (CSF) |
| Analyte Class | Specific Proteins (e.g., CRP, IgG, IgA, IgM, C3, C4, ASO, RF, HbA1c, etc.) |
| Throughput | 180 Tests per Hour |
| Optical Principle | Rate Nephelometry and/or Turbidimetry |
| Light Source | 12 V Long-Life Halogen Lamp |
| Wavelength Range | 340–700 nm (8 Fixed Wavelengths) |
| Reaction Temperature Control | 37.0 ± 0.1 °C via Solid-State Direct-Heating with Full-Circumference Thermal Sensors |
| Reaction Vessels | 40 UV-Transparent Cuvettes |
| Sample Capacity | 25 Tubes on 5-Position Rack-Based Continuous Feed |
| Dispensing Accuracy | ±5% at 3–30 µL (Sample), ±5% at 20–200 µL (Reagent) |
| Precision (CV) | ≤5% |
| Carryover | <1% |
| Stability (4h/8h) | Deviation (B) ≤ ±5% vs. Calibrator Assigned Values |
| Compliance | GB/T 14710–2009 (Environmental & Mechanical Robustness), GB 4793.1–2007 / GB 4793.9–2013 / YY 0648–2008 (Electrical Safety), GB/T 18268.1–2010 / GB/T 18268.26–2010 (EMC) |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ADME |
| Pricing | Available Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | Global Manufacturing Network |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Indiko / Indiko Plus |
| Pricing | Available Upon Request |
| Brand | INFORS |
|---|---|
| Origin | Switzerland |
| Model | YSI 2900 |
| Detection Principle | Continuous Flow (Flow-Through) |
| Sample Types | Fermentation Broth, Whole Blood, Serum, Plasma, Cell Culture Supernatants |
| Analytes | Glucose, Lactate, Glutamine, Glutamate, Ammonium*, Potassium*, Xylose, Ethanol, Methanol, Sucrose, Galactose, Lactose, Choline, Glycerol, Hydrogen Peroxide |
| Analysis Time | 60 s |
| Measurement Volume | 10–50 µL |
| Precision | CV < 2% |
| Linearity Deviation | ±5% |
| Dimensions (W×D×H) | 20.3 × 52.1 × 40.0 cm |
| Weight | 12.7 kg (excl. rack) |
| Operating Environment | 15–35 °C, 10–90% RH |
| Power | 110–120 VAC or 220–240 VAC, 50–60 Hz, 50 W |
| Compliance | CE, RoHS |
| Automation Capacity | Up to 96 samples |
| Interface Options | USB, RS232, Ethernet, OPC UA |
| Software Features | Touchscreen GUI, Multilingual Support (EN, DE, FR, ES, PT, IT, KO, ZH), Audit Trail, Data Export to CSV/Excel, Embedded Training Videos |
| Optional Modules | YSI Sitini Online Sampling System, ISE Sensor Cartridges, Thermal Printer, 96-Well Plate Sealing Membrane, Tube Racks (4/8/24/96-position) |