| Brand | Hach |
|---|---|
| Origin | USA |
| Model | NA9600 sc |
| Detection Limit | 0.01 ppb |
| Measurement Range | 0.01–10,000 ppb (non-cation-bed mode) |
| Accuracy | ±0.1 ppb (0.01–2 ppb, non-cation-bed) |
| Repeatability | <0.02 ppb or 1.5% of reading (whichever is greater) |
| Response Time | T90 ≤ 2 min (1–100 ppb) |
| Sample Temperature Range | 5–45 °C |
| Ambient Operating Temperature | 5–50 °C |
| Sample Pressure | 0.2–6 bar |
| Sample Flow Rate | 100–150 mL/min |
| Sample pH Adjustment | Diisopropylamine (DIPA), 1 L/90 days (non-cation-bed), 1 L/month (cation-bed) |
| Enclosure Rating | NEMA 4 / IP65 (with enclosure) |
| Display | 5.7-inch color LCD |
| Analog Outputs | 6 isolated 4–20 mA (max 600 Ω load) |
| Digital I/O | 6 programmable relay outputs (SPDT, 5 A, 240 VAC), 6 isolated TTL/dry-contact digital inputs |
| Communication Protocols | HART, PROFIBUS DP, Modbus RTU/TCP |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (H×W×D) | 681 × 452 × 335 mm (with enclosure) |
| Weight | 20 kg (with enclosure, no reagents) |
| Maintenance Interval | Electrolyte, activator, and calibration solutions replenished every 90 days |
| Brand | HACH |
|---|---|
| Origin | USA |
| Model | ULR CL17sc |
| Measurement Principle | DPD (N,N-Diethyl-p-phenylenediamine) Colorimetric Method |
| Measurement Range | 0.008–5 mg/L Cl₂ |
| Accuracy | ±5% or ±0.01 mg/L (whichever is greater) for 0–4 mg/L |
| Detection Limit | 0.008 mg/L Cl₂ at 25°C |
| Cycle Time | 2.5 minutes |
| Sample Flow Rate | 60–200 mL/min |
| Inlet Pressure | 0.3–5.2 bar (to Y-strainer) |
| Sample Temperature | 5–40°C |
| Operating Temperature | 5–40°C |
| Operating Humidity | 0–90% RH, non-condensing |
| IP Rating | IP66 |
| Power Supply | 12 VDC, max. 400 mA |
| Dimensions (H×W×D) | 342 × 329 × 177 mm |
| Weight | 4.1 kg |
| Light Source | LED at 510 nm, 1 cm optical path |
| Certifications | CE (EN 61326-1, CISPR 11, EN 50581), ACMA RCM, Korea KC, FCC DoC, IEC/EN 60529, ICES-003 |
| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CJ-L37 |
| Temperature Control Range | −180 °C to +50 °C |
| Temperature Accuracy | ≤ ±0.5 °C |
| Temperature Uniformity | < ±2 °C |
| Cooling/Heating Rate Adjustment Range | 0.1–12 °C/min |
| Display Resolution | 0.1 °C |
| Liquid Nitrogen Level Monitoring | Real-time with <20% threshold alarm |
| Preloaded Programs | 6 standard protocols |
| Custom Protocol Support | Yes |
| ADRC Control Algorithm | Patented Active Disturbance Rejection Control |
| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HYY.G002 |
| Instrument Category | Dry-Phase Thawing System |
| Data Interface | USB and RS232 |
| Display | High-Resolution LED Touchscreen |
| Data Export | CSV-formatted thawing logs with timestamp, temperature profile, and cycle ID |
| Brand | Hamilton |
|---|---|
| Origin | USA |
| Model | GFGJ-81000 |
| Capacity | 10–500 µL |
| Needle Gauge Options | 26s (OD 0.47 mm, ID 0.13 mm), 22s, 22 (OD 0.72 mm, ID 0.41 mm), 25 |
| Needle Length | 2 in (51 mm) |
| Volume per Inch (26s) | 0.26 µL/in |
| Volume per Inch (22) | 3.35 µL/in |
| Type | N-type (fixed needle, gas-tight plunger seal) |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HN-1200Y |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1000 W (adjustable 1–100% duty cycle) |
| Operating Frequency Range | 19–23 kHz |
| Temperature Control Range | −5 °C to +100 °C |
| Maximum Sample Volume | 1000 mL |
| Single-Sample Processing Capacity | 1 unit per cycle |
| Standard Probe Diameter | Φ20 mm |
| Optional Probes | Φ10 mm, Φ15 mm, Φ22 mm |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | TYZD-III |
| Oscillation Frequency | 10–210 rpm (adjustable) |
| Oscillation Amplitude | 22 mm |
| Timer Range | 0–24 h (countdown mode |
| Platform Dimensions | 384 × 248 mm |
| Power | 15 W |
| Input Voltage | AC 220 V, 50/60 Hz |
| Fuse | 2 A |
| Number of Shaking Platforms | 1 |
| Temperature Control | None |
| Instrument Category | Rotary Oscillator (Non-incubated) |
| Brand | Hechuang |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HC-1500T |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–120 °C |
| Operating Frequency | 25 kHz |
| Ultrasonic Power Output | 1500 W |
| Sample Volume Capacity | 0.2–2000 mL |
| Control Interface | 7-inch capacitive touchscreen |
| Pulse Mode | Adjustable from 0.1 s to 999.9 s (on/off) |
| Amplitude Compensation | Auto-compensated |
| Transducer Material | PZT ceramic (lead zirconate titanate) |
| Probe Material | ASTM-grade TC4 titanium alloy (Ti-6Al-4V) |
| Standard Probe Diameter | 15 mm (optional: 8/10/12/20 mm) |
| Integrated Cooling Compatibility | Yes |
| Enclosure | Powder-coated steel frame with polymer housing |
| Dimensions (W×D×H) | 350 × 300 × 500 mm |
| Built-in Stainless Steel Vertical Stage | Yes |
| Brand | Hechuang |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HC-2000E |
| Instrument Type | Ultrasonic Cell Disruptor |
| Temperature Range | 0–120 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 2000 W |
| Sample Volume Capacity | 0.2–2000 mL |
| Control Interface | 7-inch capacitive touchscreen |
| Pulse Mode Timing | 0.1 s to 999 min (on/off cycles independently configurable) |
| Probe Material | ASTM F136 TC4 titanium alloy |
| Transducer | PZT-4 piezoelectric ceramic (CV33-grade) |
| Amplitude Adjustment | 0–100% continuous |
| Real-time Display | Amplitude %, frequency (Hz), cumulative operating time, temperature (if external probe connected) |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Models | FB-01T (1000 mL), FB-02T (2000 mL) |
| Price Range | USD 140 – 1,400 |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Air-Bath Constant-Temperature Orbital Shaker |
| Model | HMS-310 |
| Timing Range | 0–99 min |
| Oscillation Frequency | 0–300 rpm |
| Orbit Diameter | 24 mm |
| Temperature Control | Ambient Only (No Heating/Cooling) |
| Platform Quantity | 1 |
| Platform Dimensions | 290 × 225 mm |
| External Dimensions | 300 × 270 × 145 mm |
| Max Load Capacity | 5 kg |
| Motor Power | 50 W |
| Drive Type | Brushless DC Motor |
| Display | Digital LED (Speed & Timer) |
| Brand | HengAo |
|---|---|
| Model | HMS-350 |
| Type | Vortex Mixer |
| Speed Range | 0–3000 rpm |
| Motor Power | 15 W |
| Orbit Diameter | 4 mm |
| Platform Diameter Options | 25.4 mm (single-tube) or 88.9 mm (multi-tube) |
| Max Load Capacity | 1 kg |
| Housing Material | Powder-coated aluminum alloy |
| Contact Materials | Stainless steel (304) |
| Compliance | CE-marked for laboratory use |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 80 W (HPU-100) / 400 W (HPU-400A) |
| Operating Frequency | Adjustable |
| Temperature Range | 0–100 °C |
| Sample Volume | 150 µL (minimum) |
| Sample Capacity | Single sample per cycle |
| Pulse Duty Cycle | 1–99% (adjustable) |
| Timer Range | 1–99 min |
| Probe Options | 1/8″ (HPU-100), 1/2″ (HPU-400A) |
| Sample Volumes Supported | 1–100 mL (HPU-100) |
| Memory Presets | 5 user-defined protocols |
| Brand | HengAo |
|---|---|
| Model | HSF-G3 / HSF-G6 |
| Construction | 316L Stainless Steel Support Frame & Borosilicate Glass Filtration Units |
| Configuration | 3- or 6-position parallel filtration stations |
| Filtration Principle | Vacuum-assisted membrane filtration (negative pressure-driven) |
| Compliance | Meets ISO 7218:2017 (Microbiology of food and animal feeding stuffs — General requirements and guidance for microbiological examinations), USP <61> & <62>, and ASTM D5465-22 (Standard Test Method for Determination of Total Coliforms and Escherichia coli in Water by Membrane Filtration) |
| Sterilization Compatibility | Autoclavable (121 °C, 20 min) and compatible with ethylene oxide (EtO) and vaporized hydrogen peroxide (VHP) decontamination protocols |
| Operating Pressure Range | −0.08 to −0.1 MPa (adjustable via individual inline valves) |
| Filter Diameter | 47 mm standard |
| Maximum Sample Volume per Station | 500 mL |
| Material Certifications | FDA-compliant silicone gaskets |
| Data Integrity | Designed for GLP/GMP environments with optional audit-trail-enabled vacuum controller integration |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Line | HSF-S1/S3/S6 (Stainless Steel Configuration) |
| Material | 316L Surgical-Grade Stainless Steel |
| Sterilization Compatibility | Autoclavable up to 180°C |
| Filter Capacity | 1/3/6 Stations (Configurable) |
| Compliance | USP <71> Sterility Testing, ISO 8573-1 Clean Air Classification (when used with certified vacuum source) |
| Vacuum Interface | Standard 1/4" NPT or Quick-Connect Fitting |
| Filtration Vessel Options | Removable 250 mL or 500 mL Stainless Steel Filter Cups with Sintered 316L Stainless Steel Frits (Pore Size: 0.2 µm or 0.45 µm standard) |
| Valve Type | Individual On/Off Ball Valves per Station |
| Sealing | FDA-Compliant Silicone or EPDM O-Rings (USP Class VI certified) |
| Dimensions (S6) | 320 × 220 × 280 mm (W × D × H) |
| Weight (S6) | 4.8 kg |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HVS-10M/4M |
| Timer Range | 0–99 min |
| Oscillation Frequency | 60–500 rpm |
| Amplitude | 30 mm |
| Temperature Control | Ambient Only |
| Platform Quantity | 2 |
| Power Supply | 220 V ±10%, 50–60 Hz, 1.0 A |
| Dimensions (L×W×H) | 320 × 320 × 340 mm |
| Power Consumption | 150 W |
| Weight | 35 kg |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vertical Orbital Shaker for Liquid-Liquid Extraction |
| Timer Range | 0–99 min |
| Oscillation Frequency | 20–300 rpm |
| Stroke Amplitude | 40 mm |
| Temperature Control | Ambient Only |
| Shelf Configuration | Dual Adjustable Shelves |
| Oscillation Modes | Vertical and Tilted (selectable) |
| Maximum Flask Capacity | 2 L separatory funnels |
| Brand | HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Water Bath Incubator Shaker |
| Model | HWT-10C |
| Heating Capacity | 10 L |
| Temperature Range | Ambient to 95 °C |
| Oscillation Frequency | 10–200 rpm |
| Oscillation Amplitude | 0–24 mm |
| Number of Shaking Platforms | 1 |
| Control System | Microprocessor-based PID temperature control with LED display |
| Heating Element | PTC ceramic heater with silicone rubber heating belt |
| Drive Mechanism | Brushless DC motor |
| Construction Material | 304 stainless steel (wetted parts) |
| Insulation Design | Multi-layer side-and-bottom thermal insulation |
| Lid Design | V-shaped anti-drip cover |
| Operational Mode | Integrated shaker + standalone water bath (removable platform) |
| Brand | HOF |
|---|---|
| Origin | Germany |
| Model | FT4-38 |
| Temperature Range | −73 °C to +40 °C |
| Temperature Accuracy | ±1 °C |
| Cooling Rate | −1 °C/min |
| Heating Rate | +1 °C/min |
| Batch Capacity | up to 10 × 20 L single-use bags |
| Compliance | FDA 21 CFR Part 11 (audit trail, role-based access control), GMP-ready architecture |
| Software | Integrated PC with validated GUI, PDF report generation |
| Brand | Honeywell BW |
|---|---|
| Origin | Canada |
| Model | XCD |
| Sensor Compatibility | Catalytic Bead (LEL), Electrochemical (Toxic/O₂), NDIR (Combustible) |
| Output | 4–20 mA (3-wire), HART optional |
| Certifications | ATEX/IECEx Zone 1/2, UL Class I Div 1/2, CSA C/US |
| Enclosure Rating | IP66/IP67 |
| Operating Temperature | –40 °C to +65 °C |
| Display | Backlit LCD with bar graph, gas type icon, status indicators |
| Calibration | Magnetic wand–enabled, no-open-box configuration & bump test |
| Relay Outputs | 3 programmable SPDT relays |
| Housing Material | UV-stabilized polycarbonate & stainless steel mounting plate |
| Sensor Mounting | Integral bottom port, remote sensor option (RTD/RFD variants) |
| Compliance | EN 60079-29-1, EN 45544-1, IEC 61000-6-2/6-4, FDA 21 CFR Part 11–ready software support (via Honeywell Analytics Suite) |
| Brand | EXODUS |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T-2800 |
| Temperature Control Range | 2–8 °C |
| Sample Processing Volume | 0.5–10 L |
| Sterilization Method | Ethylene Oxide (EO) Gas |
| Operating Principle | Ultrasonic Nanofiltration |
| Purification Throughput | 1–2 L/h |
| Brand | IBI Scientific |
|---|---|
| Origin | USA |
| Model | Belly Button |
| Instrument Type | Mini Orbital Shaker |
| Speed Range | 0–100 rpm |
| Tilt Angle Adjustment | 0–8° |
| Operating Temperature | 0–40 °C |
| Platform Size | 18 × 18 cm |
| Load Capacity | 2 kg (5 lbs) |
| Platform Material | Chemically Resistant Polymer |
| Noise Level | <45 dB(A) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE, RoHS |
| Compliance | Suitable for ISO 13485-aligned lab workflows, compatible with GLP documentation requirements |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Integrated Control Tower Bioreactor System |
| Reactor Volume Range | 0.5–10 L |
| Temperature Range | 0–100 °C |
| Sterilization Method | Autoclavable (121 °C, 20 min) |
| Number of Independent Gas Channels | 4 (Air, O2, N2, CO2) |
| Mass Flow Control Range | 0–2000 cc/min per channel |
| Integrated Peristaltic Pumps | 4 (Watson-Marlow 114DV) |
| Stirring Speed Range | 1–2200 rpm |
| pH Measurement Range | 0–14 pH (±0.02 pH accuracy) |
| Dissolved Oxygen Range | 0–200 %sat (±0.3 %sat accuracy) |
| Conductivity & Turbidity Sensor Interfaces | Yes |
| CO₂ Sensor Interface | Yes |
| Chaotic Mixing Mode | Yes |
| Heating Blanket Power | 250 W |
| Data Storage Capacity | 32 GB internal |
| Compliance Options | FDA 21 CFR Part 11–compliant software version available |
| Connectivity | Ethernet, USB, RS232, Wi-Fi, external pump/thermostat/single-use reactor interfaces |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Type | Integrated Control Tower Fermenter System |
| Vessel Capacity | 0.5–10 L |
| Aeration | Four Independent Mass Flow Controlled Gas Lines (Air, O2, N2, CO₂) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200 % saturation |
| Accuracy | ±0.3 % sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring | Chaotic Mixing Mode + Standard Profile/Cascade Modes |
| Speed Range | 1–2200 rpm |
| Reversibility | Yes |
| Peristaltic Pumps | 4 × Watson-Marlow 114DV heads (Acid, Base, Antifoam, Feed) |
| Flow Range | 1–270 mL/min |
| Data Management | 32 GB internal storage, Ethernet, USB, RS232, Wi-Fi, FDA 21 CFR Part 11-compliant software option available |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Benchtop Bioreactor with Integrated Control Tower |
| Vessel Capacity | 0.5–10 L |
| Gas Supply | Four independent mass flow-controlled gas lines (Air, O2, N2, CO2) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200% saturation |
| Accuracy | ±0.3% sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring | Chaotic Mixing mode + conventional profile/Cascade control |
| Speed range | 1–2200 rpm |
| Reversibility | Yes |
| Sensors Supported | pH, DO, temperature, level, foam, CO₂, conductivity, turbidity |
| Peristaltic Pumps | 4 × Watson-Marlow 114DV heads (acid, base, antifoam, feed) |
| Flow range | 1–270 mL/min |
| Software | Touch-enabled tablet interface (10.4″), real-time data logging, calibration management, FDA 21 CFR Part 11-compliant version optional |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Connectivity | Ethernet, USB, RS232, Wi-Fi, external thermostat & pump interfaces |
| Enclosure Rating | IP20 |
| Power | 100–240 V AC, 50/60 Hz |
| Max. input power | 1100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HABITAT |
| Dimensions (W×H×D) | 224 × 624 × 405 mm |
| Stirring Speed Range | 1–2200 rpm |
| Peristaltic Pump Heads | 4 (acid, base, antifoam, level) |
| Pump Flow Rate | 1–270 mL/min |
| Gas Flow Rate | 0–2 L/min (CELL/CCT) |
| Mass Flow Controllers (MFCs) | 4 (Air, O₂, N₂, CO₂) |
| Controlled Parameters | Agitation, Aeration, Liquid Feed, Off-gas Analysis, Temperature, pH, Dissolved Oxygen (DO), Foam, Level, Conductivity, CO₂, Turbidity, Light |
| Interfaces | USB, RS-232, Ethernet, SU Connection, Chiller Interface, External Pump Control, 4–20 mA Analog I/O |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Model | HABITAT Photo Ferment CCT |
| Vessel Volume | 0.5–10 L |
| Gas Supply | Four independent mass flow-controlled gas lines (N₂, O₂, air, CO₂) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200% saturation |
| Accuracy | ±0.3% sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring Speed | 1–2200 rpm |
| Speed Deviation | ±2% (≥100 rpm), ±5 rpm (<100 rpm) |
| LED Illumination | Adjustable intensity & timing for circadian simulation |
| Chaotic Mixing Mode | Enabled |
| Integrated Peristaltic Pumps | 4 Watson-Marlow 114DV heads (acid, base, antifoam, feed) |
| Data Storage | 32 GB internal |
| Compliance Options | FDA 21 CFR Part 11–compliant software version available |
| Interfaces | Ethernet, USB, RS232, external pump/thermostat/single-use reactor ports |
| Protection Rating | IP20 |
| Power Input | 100–240 V, 50/60 Hz |
| Max. Power Consumption | 1100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | HABITAT photo ferment |
| Vessel Volume | 0.5–10 L |
| Aeration System | Integrated 4-channel mass flow controllers (N₂, O₂, air, CO₂) |
| pH Control | Range 0–14, Accuracy ±0.02 |
| Dissolved Oxygen (DO) Control | Range 0–200% saturation, Accuracy ±0.03% |
| Temperature Control | Range 0–100 °C, Accuracy ±0.2 °C |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | HS 260 basic |
| Instrument Type | Reciprocal Shaker |
| Timer Range | 5–50 min |
| Oscillation Frequency | 0–300 rpm |
| Stroke Length | 20 mm |
| Temperature Control | None |
| Platform Quantity | 1 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS 260 basic |
| Timer Range | 5–50 min |
| Oscillation Frequency | 0–300 rpm |
| Stroke Length | 20 mm |
| Platform Quantity | 1 |
| Max Load Capacity (incl. clamp) | 7.5 kg |
| Input Power | 45 W |
| Dimensions (W×H×D) | 360 × 420 × 100 mm |
| Weight | 8.5 kg |
| Ambient Temperature Range | 5–50 °C |
| Relative Humidity Limit | ≤80 % |
| Protection Class | IP21 |
| Voltage | 220–240 V / 100–120 V, 50/60 Hz |
| Motor Output Power | 10 W |
| Minimum Adjustable Speed | 20 rpm |
| Display | LED for speed and timer |
| Operation Modes | Timed or continuous |
| Platform Type | Flat reciprocating platform |