Bioengineering Equipment
Filter
Showing 361–390 of 1942 results
| Brand | D&A (De’an Te) |
|---|---|
| Model | ES-F101 |
| Origin | Tianjin, China |
| Type | Halogen-based Thermogravimetric Moisture Analyzer |
| Maximum Capacity | 120 g |
| Readability | 10 mg |
| Moisture Content Readability | 0.1% |
| Sample Pan Diameter | Ø90 mm |
| Heating Source | Circular 450 W Halogen Lamp |
| Temperature Range | 60–160 °C (1 °C increments) |
| Drying Modes | Standard, Step, Rapid |
| Termination Modes | Auto-stop (loss-on-drying threshold), Manual Stop, Timer Stop |
| Calibration | External weight calibration |
| Interface | RS232 bidirectional serial port |
| Operating Temperature | 13–25 °C |
| Warm-up Time | 30–60 min |
| Display | LCD with real-time parameter indicators (%MC, %DC, %AD, %AM, Program ID, stability status) |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Daxluot-16S |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 22–2200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Parallel Channels | 16 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Auto-compensated under variable load |
| Data Storage Capacity | 20 user-defined protocols |
| Display | 7-inch TFT capacitive touchscreen |
| Safety Protections | Overtemperature, overcurrent, overtime, and fault alarm |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Daxluot-24S |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 25–2500 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Range | −5 to 100 °C |
| Sample Volume per Channel | 0.1–5 mL |
| Number of Simultaneous Samples | 24 |
| Display | 7-inch TFT Touchscreen |
| Data Storage | 20 Preset Protocols |
| Amplitude Control | Auto-compensated |
| Probe Material | Titanium Alloy (Grade 5) |
| Safety Features | Overtemperature, Overpower, and Overtime Protection |
| Cooling Interface | Integrated Low-Temperature Circulating Rack (−5 to 100 °C) |
| Communication Option | RS-232/USB (optional) |
| Footswitch Support | Optional |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-4SKII |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 18–1800 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 4 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Auto-compensated under variable load |
| Data Storage Capacity | 20 user-defined protocols |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Safety Protections | Overtemperature, over-power, and overtime cutoffs |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Cryogenic Compatibility | Integrated Peltier-cooled sample rack with external chiller port |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-8S |
| Ultrasonic Power | 20–2000 W (adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking) |
| Temperature Control Range | −5 to 100 °C |
| Sample Volume per Channel | 5–100 mL |
| Number of Simultaneous Samples | 8 |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic Load-Compensated |
| Data Storage | 20 Preset Protocols |
| Display | 7-inch TFT Touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Brand | Daxluot |
|---|---|
| Model | Dxluot-4SKI |
| Origin | Shanghai, China |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 12–1200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-frequency tracking) |
| Sample Volume per Channel | 1–10 mL |
| Number of Simultaneous Samples | 4 |
| Temperature Control Range | −5 to 100 °C |
| Probe Material | Titanium Alloy (Ti-6Al-4V) |
| Amplitude Regulation | Automatic load-compensated |
| Programmable Parameters | 20 user-defined protocols |
| Ultrasound On/Off Time | 0.1–99.9 s (adjustable) |
| Total Cycle Duration | 0.1 s – 99 h 59 min 59 s |
| Safety Protections | Overtemperature, Overpower, Overtime |
| Display | 7-inch TFT capacitive touchscreen |
| Input Power | AC 220 V ±5%, 50 Hz (110 V optional) |
| Communication Interface | RS-232 or USB (optional) |
| Footswitch Support | Optional |
| Data Logging | Timestamped protocol execution history |
| Cooling Integration | Integrated Peltier-assisted cold block with recirculating thermal management |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ddSEQ |
| Regulatory Classification | Import (CE-IVD compliant for research use only) |
| Intended Use | Automated microfluidic droplet generation for single-cell RNA sequencing library preparation |
| Brand | Deers/DS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MS-100 Heated |
| Pricing | USD 980 (FOB) |
| Instrument Type | Compact Programmable Temperature-Controlled Shaker |
| Timer Range | 0–99 h 59 min |
| Oscillation Speed | 300–2000 rpm |
| Oscillation Amplitude | 3 mm (Horizontal Orbital) |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Uniformity | ≤ ±0.3°C |
| Temperature Stability | ±0.3°C |
| Display Resolution | 0.1°C |
| Heating Rate | <15 min (20°C → 100°C) |
| Power Consumption | 200 W |
| Dimensions (W×D×H) | 270 × 190 × 170 mm |
| Net Weight | 8.3 kg |
| Plate Configuration | Single interchangeable aluminum block platform |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | DLT-2400 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Power Output | 2400 W (continuously adjustable from 1% to 100%) |
| Sample Volume Capacity | 500–2000 mL |
| Temperature Control Range | 0–99.9 °C |
| Duty Cycle Adjustment | 0.1–99.9% |
| Display | 7-inch TFT capacitive touchscreen |
| Probe Material | TC4 titanium alloy |
| Standard Horn Diameter | Φ25 mm (optional horns: Φ3, 6, 10, 15, 20, 22, 25, 28 mm) |
| Safety Features | Overcurrent, overvoltage, overtemperature, and timer fault protection |
| Cooling | Integrated NTC thermistor-based sample temperature monitoring |
| Configuration | Separated main unit + acoustic isolation chamber with motorized lift stage and LED illumination |
| Optional Upgrades | UV sterilization module |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | DWY-TS4228T-V3 |
| Price | USD 1,150 (FOB Shanghai) |
| Thermal Detector | Uncooled Vanadium Oxide (VOx) |
| Thermal Spectral Band | 8–14 µm |
| Thermal Resolution | 256 × 192 |
| Visible Sensor | 4 MP CMOS |
| Optical Zoom | 32× (4.8–153 mm) |
| IR Illumination Range | 100 m |
| Digital Image Enhancement | Defogging Algorithm |
| Temperature Range | −20 °C to +550 °C |
| Temperature Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Fire Detection Distance | up to 250 m |
| Smoke Detection Distance | up to 1500 m |
| Pan | Continuous 360° |
| Pan Speed | 0.1–200°/s |
| Tilt | −5° to +90° |
| Presets | 300 |
| Scan Patterns | 8 |
| Positioning Accuracy | 0.1° |
| Housing Material | High-Strength Aluminum Alloy |
| Ingress Protection | IP66 |
| Surge Protection | 6 kV |
| Operating Temperature | −40 °C to +70 °C |
| Power Input | AC24 V / DC36 V / DC48 V / HI-POE |
| Onboard Storage | 256 GB microSD |
| Data Resilience | Offline Recording & Resume-on-Connect |
| Protocol Support | ONVIF Profile S/G, RTSP, HTTP, PSIA, GB/T 28181 |
| Third-Party Integration | Compatible with VMS, SCADA, and IoT platforms |
| [Brand | Denator AB |
|---|---|
| Origin | Sweden |
| Model | Stabilizor T1 |
| Type | Import |
| Distribution Status | Authorized Distributor] |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | BS600 |
| Pricing | Available Upon Request |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BS600 |
| Pricing | Available Upon Request |
| Sealing Diameter Range | 1/4″ to 1″ (6.35 mm to 25.4 mm) OD |
| Seal Width | 20 mm |
| Sealing Time | 2–4 min |
| Actuation | Fully Automatic Compression |
| Cooling Method | Forced Air Cooling |
| Dimensions (W×H×D) | 141 × 223 × 369 mm |
| Net Weight | ~3.5 kg |
| Operation Interface | Touch-Enabled Single-Touch Control Panel |
| User Access Control | Three-Tier Role-Based Authentication |
| Audit Trail | Full GLP/GMP-Compliant Electronic Log with Timestamped Events |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Compliance | ISO 13485 Design Controls, ASTM F2097 (Standard Guide for Sterile Barrier Systems), FDA 21 CFR Part 11 Ready (via optional software module) |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | BW600 |
| Pricing | Upon Request |
| Cooling Method | Air-cooled |
| Welding Cycle Time | 90–180 s |
| Compatible Tubing OD | 1/4″ to 1″ (6.35 mm to 25.4 mm) |
| Power Supply | 220 V / 50 Hz |
| Dimensions (W × H × D) | 270 × 304 × 570 mm |
| Net Weight | 15 kg |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | BW600 |
| Type | Fully Enclosed Automated Sterile Tubing Connector |
| Operating Principle | Thermal Cutting & Fusion Welding of Thermoplastic Tubing |
| Compliance Framework | Supports 21 CFR Part 11 Audit Trail, GLP/GMP-Ready Software Architecture |
| User Access Control | Three-Tier Role-Based Permissions (Admin/Operator/Viewer) |
| Cycle Capacity | ≥100 Consecutive Sterile Connections Without System Interruption |
| Consumables | Domestically Sourced, ISO 13485–Certified Tubing Adapters and Heating Blades |
| Environmental Sealing | Class A (ISO 5) Internal Chamber Integrity Verified per ISO 14644-1 |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Dry-Phase Thawing System |
| Model | C1 (Single-Position) / C4 (Four-Position) |
| Temperature Range | 35–40 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Compatible Vials | 2 mL Internal Thread, External Thread, and CBS-Standard Cryovials |
| Regulatory Design Basis | Engineered for GLP/GMP-aligned workflows |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Models | FF-16, FF-18, FF-26 |
| Price Range | USD 28,000 – 57,000 |
| Fill Capacity | 1 L × 6 bottles, 1 L × 8 bottles, or 2 L × 6 bottles |
| Pump Type | Peristaltic |
| Weighing Integration | Simultaneous centrifuge bottle and cap weighing |
| Enclosure | Foam-suppression shield |
| Form Factor | Benchtop, ISO Class 5-compatible |
| Control Interface | Touchscreen HMI with automated cycle sequencing |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 0402257 (Configurable Layer Count) |
| Price Range | USD 7,000 – 14,000 (FOB Tianjin) |
| Temperature Range | Ambient to 40 °C (with optional incubator integration) |
| Working Volume per Layer | 200 mL |
| Total Configurable Capacity | Up to 10 layers = 36 parallel culture vessels |
| Material | Medical-Grade Imported Polymeric Resin (USP Class VI compliant) |
| Sterilization Method | Autoclavable (121 °C, 20 min, saturated steam) |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Large-Scale Cell Culture System |
| Temperature Range | −60 °C to 60 °C |
| Culture Volume per Layer | 636 mL (scalable to 636 × n mL) |
| Stackable Layers | 1–40 |
| Material | Polyethylene (PE) |
| Sterilization Method | Gamma Irradiation |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | MaxMixer-100 |
| Timing Range | Mixing Time 1–99 min, Pause Time 0–9 s, Cycles 1–9 |
| Oscillation Frequency | 50–100 rpm |
| Amplitude | 50 mm |
| Tray Quantity | 1 |
| Power Supply | 220 V / 50 Hz, 800 W |
| Dimensions (L×W×H) | 840 × 670 × 490 mm |
| Net Weight | 52 kg |
| Construction | Full stainless steel chassis |
| Compliance | Designed for GMP-compliant environments |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | MaxMixer-100 |
| Timer Range | Mix Time 1–99 min, Pause Time 0–99 sec, Cycles 1–9 |
| Oscillation Frequency | 50–100 rpm (adjustable) |
| Amplitude | 50 mm |
| Chamber Temperature | Ambient |
| Platform Count | 1 |
| Dimensions (L×W×H) | 840 × 670 × 490 mm |
| Net Weight | 52 kg |
| Power Supply | 220 V / 50 Hz, 800 W |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DHS Quad-Cell Factory System |
| Pricing | Available Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DHZ-C |
| Price | USD 2,350 (approx.) |
| Instrument Type | Orbital Shaker |
| Timer Range | None (Manual Operation) |
| Oscillation Frequency | 40–280 rpm, Continuously Adjustable with Digital Display |
| Oscillation Amplitude | 25 mm (Standard Orbital Motion) |
| Temperature Control Range | Ambient +5°C to 60°C |
| Shelf Quantity | 1 Platform |
| Max Capacity | 6 × 5000 mL Flasks (Configurable per User Requirement) |
| Noise Level | <50 dB(A) at 1 m Distance During Maximum Speed Operation |
| Dimensions (W×D×H) | 1300 × 650 × 700 mm |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 300 W |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Bioruptor Pico |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 300 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 4 °C to ambient |
| Sample Volume | 5 µL – 2 mL |
| Maximum Sample Capacity | 18 tubes (depending on adapter) |
| Cooling System | Integrated electromagnetic valve-controlled recirculating chiller |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Pico |
| Ultrasonic Power | 25–210 W |
| Operating Frequency | 20–60 kHz |
| Temperature Range | −20 °C to 40 °C |
| Sample Volume Capacity | 5 µL – 12 mL (dependent on adapter selection) |
| Maximum Simultaneous Samples | 12 |
| Cooling System | Integrated solenoid-valve-controlled recirculating chiller |
| Fragment Size Range (DNA) | 100 bp – 1 kb |
| Adapter Standard | 0.5 mL tube holder with mechanical locking mechanism |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Bioruptor Plus |
| Instrument Type | Non-contact ultrasonic cell disruptor |
| Sample Capacity | 6–12 tubes (0.5 mL to 50 mL) |
| Cooling | Integrated 4 °C water bath with optional recirculating chiller |
| Control Interface | Digital LCD timer & power selector (Low/High) |
| Safety | Fully sealed tube processing, acoustic shielding enclosure, overheat protection |
| Compliance | Designed for GLP-compliant chromatin shearing and DNA fragmentation workflows per EN ISO 13485-aligned manufacturing standards |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | UCD-300 (Plus) |
| Instrument Type | Non-contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 160–320 W |
| Operating Frequency | 40 kHz (typical, fixed-frequency transducer array) |
| Temperature Range | −20 °C to +40 °C (with optional chiller integration) |
| Sample Volume Capacity | 5 µL – 20 mL (dependent on adapter configuration) |
| Throughput | 1–12 samples per run (6–12 standard with rotating rack |
| Cooling Method | External recirculating chiller or integrated Peltier-assisted bath temperature control |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Bioruptor Plus |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 400–700 W |
| Operating Frequency | 20 kHz |
| Temperature Control | Ambient (with optional water-cooling system) |
| Sample Volume Range | 5 µL – 20 mL |
| Maximum Parallel Samples | 12 |
| Compatible Tube Formats | 0.5 mL, 1.5 mL, 15 mL, 50 mL centrifuge tubes |
| Safety | Closed-tube, non-contact, aerosol-free operation |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ISO/IEC 17025 laboratory practices |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | new pico |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 300 W |
| Operating Frequency | 40 kHz |
| Temperature Range | 4 °C to ambient |
| Maximum Sample Capacity | 16 tubes |
| Sample Volume Range | 20 µL – 2 mL |
| Cooling System | Integrated solenoid-valve-controlled recirculating chiller |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | Megaruptor |
| Application | High-Throughput HMW DNA Fragmentation for Long-Read Sequencing Platforms |