| Brand | Lianhua |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | LH-OM20 |
| Instrument Category | Vortex Mixer |
| Control Modes | Continuous & Pulse (Touch-Activated) |
| Drive System | Imported Brushless DC Motor |
| Design | Compact, Portable, Low-Profile Benchtop Form Factor |
| Application Focus | Microvolume Liquid Homogenization (0.2–15 mL Tubes) |
| Brand | Lohand |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LH-ES20 |
| Instrument Type | Magnetic Stirring & Mixing Equipment |
| Speed Range | 0–1500 rpm |
| Housing Material | Stainless Steel (304) |
| Power Input | Low-voltage DC (compatible with portable power banks and automotive 12 V systems) |
| Form Factor | Compact Benchtop Design |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 131-1310 |
| Instrument Category | Vortex Mixer / Sample Homogenizer |
| Timer Range | 0–1000 min |
| Oscillation Frequency | 0–3000 rpm |
| Orbital Amplitude | 4.5 mm (circular motion) |
| Platform Quantity | 1 |
| Power Consumption | 12 W |
| Input Voltage | 100–240 V, 50/60 Hz |
| Enclosure Rating | IP42 |
| Operating Environment | 5–40 °C, ≤80% RH |
| Dimensions (W×D×H) | 100 × 93 × 72 mm |
| Net Weight | 0.7 kg |
| Max Sample Volume per Tube | 50 mL |
| Control Method | Single-knob fixed-speed adjustment |
| Motor Type | Brushless DC Motor |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model No. | 130-0580 |
| Instrument Type | Orbital Shaker |
| Timer Range | 1 min – 23 h 59 min |
| Oscillation Speed | 40 – 200 rpm (5 rpm increments) |
| Platform Quantity | 1 |
| Platform Size | 250 × 250 mm |
| Max Load Capacity | 2 kg |
| Motor Type | Brushless DC Motor |
| Motion Type | Orbital (Circular), 20 mm diameter orbit |
| Power Consumption | 30 W |
| Input Voltage | AC 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 355 × 260 × 100 mm |
| Net Weight | 3.65 kg |
| Brand | Mancang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | MC-ABSF-II |
| Price Range | USD 70,000 – 112,000 |
| Category | Life Science / Bioengineering |
| Measurement Resolution | 0.01 mL |
| Flow Rate Detection Range | 0–250 mL/h |
| Reactor Volume Options | 0.25 L or 0.5 L per compartment |
| Maximum Parallel Reactors | 1, 2, 3, 4, or 6 channels |
| Brand | Mancang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | MC-JGF-5L/4 |
| Vessel Volume Range | 0.5–500 L |
| Aeration System | Integrated |
| pH Control Range | 2–12 |
| Dissolved Oxygen (DO) Control Range | 0–100% |
| Temperature Control Range | 5–65 °C (chilled coolant + electric heating) |
| Brand | Mancang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MC-JSF-1T/3 |
| Vessel Volume | 10 L (per vessel) × 3 |
| Aeration System | Quadruple sterile air supply lines |
| pH Control Range | 2.0–12.0 |
| Dissolved Oxygen (DO) Control Range | 0–200% saturation |
| Temperature Control Range | 5–65 °C (via chilled water + electric heating) |
| Brand | Mancang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Model | MC-JSF-50 |
| Vessel Volume | 0.5–500 L (Standard Config: 50 L) |
| Aeration System | Integrated Deep-Flow Sterile Air Supply |
| pH Control Range | 2.0–12.0 |
| Dissolved Oxygen (DO) Control Range | 0–100% (or 0–200%) |
| Temperature Control Range | 0–100 °C |
| Design Pressure | 0.3 MPa |
| Operating Pressure | 0.15 MPa |
| Material | SUS316L/SUS304 Stainless Steel |
| Internal Surface Finish | Ra ≤ 0.4 µm |
| External Finish | Bead-Blasted or Polished |
| Stirring Speed | 50–600 rpm (±1% accuracy, 1 rpm resolution) |
| Sterilization | In-situ Steam Sterilization (SIP), 121 °C for 30 min |
| Compliance | Meets ISO 8573-1 (compressed air purity), ASME BPE-2021 (bioprocessing equipment), and GLP/GMP design principles |
| Brand | Mancang |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MC-NFS-II |
| Reactor Volume | 1 L per vessel |
| Max. Simultaneous Reactors | 4 |
| Sample Batch Capacity | ≤100 bags |
| Measurement Resolution | 3.5 (unitless, dimensionless digestibility index) |
| Detection Range | 0–6000 (arbitrary units correlating to gas production or metabolite accumulation) |
| Temperature Control Range | Ambient to 45 °C |
| Standard Setpoint | 39.5 °C |
| Accuracy | ±0.1 °C |
| Oscillation | 3D spatial shaking |
| Filtration Pore Size | 25–30 µm |
| Sample Mass per Bag | 0.25–1.5 g |
| Digestibility Range | 0–100% |
| Reproducibility (RSD) | ≤0.2% |
| Data Logging Intervals | 1/5/10/30 min |
| Output Format | Excel (.xlsx) via USB export |
| Brand | 908 Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MAVERICK |
| Price Range | USD 1,500 – 150,000 (FOB) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-700 Series |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 40,000 psi |
| Max Flow Rate | 15.6 L/min |
| Inlet Temperature Range | Up to 75 °C |
| Power Supply | 3-Phase, 380 V, 15–50 HP |
| Air Supply | 50–150 psi, 1 SCFM @ 50 psi, Dew Point: 0–35 °F |
| Dimensions | 74 × 180 × 145 cm |
| Weight | 675–900 kg |
| Chamber Material | Diamond-Embedded Stainless Steel |
| Construction | Fully 316L Stainless Steel |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-110Y |
| Instrument Type | High-Pressure Cell Disruptor |
| Operating Pressure Range | 3,000–23,000 psi |
| Max. Flow Rate | 250–600 mL/min |
| Feed Temperature Range | –25°C to +75°C |
| Minimum Sample Volume | 14 mL |
| Compressed Air Requirement | 57 scfm at 120 psi, 15 hp (11 kW) |
| Dimensions | 28 × 41 × 76 cm |
| Weight | 25 kg |
| Interaction Chamber Material | Diamond or Ceramic |
| Wetted Parts | 300-series Stainless Steel (Chromium-Plated Piston) |
| Integrated Cooling Coil | 17 ft (13 mL volume) |
| Cleaning | CIP-capable (Clean-in-Place) |
| Certification | Explosion-Proof & Portable Design |
| Brand | MICHEM (MechaTech) |
|---|---|
| Origin | United Kingdom |
| Model | Hyscan II |
| Measurement Principle | Quantitative Pressure-Reduction Solidification Method |
| Analysis Time | ≤ 5 min per sample |
| Detection Limit | 0.01 cm³/100 g Al |
| Accuracy | ±<5% RSD |
| Compliance | Designed for GLP/GMP-aligned foundry QA workflows |
| Portability | Benchtop with integrated vacuum system and field-deployable rugged chassis |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-110EH |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 30,000 psi (207 MPa) |
| Max Flow Rate | 450 mL/min |
| Inlet Temp. Range | ≤75°C |
| Power Supply | 3-Phase, 380 V, 5 HP (3.7 kW) |
| Fluid Path Volume | 100 mL |
| Compressed Air Requirement | 35–150 psi |
| Dew Point | 0–35°F |
| Minimum Sample Volume | 120 mL |
| Dimensions | 73 × 87 × 148 cm |
| Weight | 205 kg |
| IXC Chamber Material | Synthetic Diamond |
| Regulatory Compliance | CE Certified |
| Cleaning | CIP-Compatible |
| Sterilization | SIP-Capable (Steam or Hot Water) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HC-8000 |
| Price Range | USD $14,000–$70,000 |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 1,000–8,000 psi |
| Max Flow Rate | 1,000 mL/min |
| Feed Temperature Limit | 75 °C |
| Compressed Air Requirement | 57 SCFM at 50 psi, dew point −17.7 to 1.6 °C, 15 hp (11 kW) |
| Minimum Sample Volume | 250 mL |
| Dimensions | 58 × 38 × 58 cm |
| Weight | 26.7 kg |
| Construction Material | Electropolished 316 Stainless Steel |
| Cleaning | CIP-capable high-pressure fluid path |
| Drive Mechanism | Pneumatic, explosion-proof |
| Sterilization Compliance | Autoclavable and SIP-compatible components |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Configuration | Sterile, Pre-assembled Transwell-Compatible Insert System |
| Membrane Material | Polycarbonate (PCF) or Polyester (PET) |
| Pore Size | 0.4 µm (PCF) or 1.0 µm (PET) |
| Well Count | 24 |
| Format | Integrated Insert + Receiver Plate + Lid |
| Sterility | Certified Sterile, Non-Pyrogenic, DNase/RNase-Free |
| Packaging | Individual Blister Pack or Multi-Pack |
| Compliance | ISO 13485–Certified Manufacturing |
| Intended Use | In vitro cell culture, co-culture, permeability assays, differentiation studies, and barrier function analysis |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | NovAseptic® Magnetic Stirrer |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ Blaze™ System |
| Volume Range | 1 L (Blaze™) / up to 10 L (Blaze+™) |
| System Architecture | Closed, single-use, GMP-ready process development platform |
| Core Technology | NxGen™ microfluidic mixing |
| Regulatory Alignment | Supports FDA 21 CFR Part 11–compliant data integrity, GLP/GMP process transfer readiness |
| Disposable Components | NxGen™ single-use chips (with/without inline dilution), sterile tubing kits for external vessel integration |
| Downstream Compatibility | Integrated TFF, sterile filtration, and fill-finish workflow support |
| Scalability Pathway | Direct CPP/CQA transfer from Blaze™ → Blaze+™ → NanoAssemblr™ Production System |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | NanoAssemblr™ Commercial Manufacturing System |
| Pricing | Upon Request |
| Flow Rate Range | 6–48 L/h (dependent on disposable flow path kit) |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ GMP System |
| Flow Rate Range | 60–200 mL/min (3.6–12 L/h) |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ Spark™ Instrument |
| Sample Volume Range | 25–250 µL |
| Mixing Technology | NxGen™ Microfluidic Vortex Mixing |
| Sterility Design | BSC-Compatible, Aseptic Operation Ready |
| Chip Type | Single-Use, Gamma-Irradiated Cartridge |
| Scalability Pathway | Seamless Transition to NanoAssemblr™ Ignite™ and NxGen™ Production Platforms |
| Regulatory Context | Designed for GLP-compliant early-stage development, supports 21 CFR Part 11–ready software integration (optional) |
| Brand | NanoEX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NanoEX |
| Price Range | USD 70,000 – 140,000 |
| Dimensions | 537 × 260 × 363 mm |
| Weight | 10 kg |
| Throughput | Up to 168 mL/h |
| Sample Volume Range | 100 µL – 500 mL |
| Display | Integrated TFT touchscreen |
| Sterilization Compatibility | Autoclavable components |
| Membrane Compatibility | Interchangeable asymmetric nanopore membrane (ANM) cassettes |
| Brand | NEPA GENE |
|---|---|
| Origin | Japan |
| Model | PF-NP-200 |
| Temperature Range | −80 °C to Ambient |
| Cooling Rate | −0.1 to −3.0 °C/min |
| Cooling Technology | Stirling Cycle Refrigeration |
| Display | LCD Touchscreen Interface |
| Data Export | CSV Format |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 200 W |
| Dimensions (L×W×H) | 340 × 366 × 466 mm |
| Weight | 18 kg |
| Sample Capacity | 55 × 2 mL Cryovials or 1 × 25 mL Cryobag (optional modules available) |
| Restart Function | Auto-resume after power failure |
| Compliance | Designed for GLP-compliant cell banking and ISO 13485-aligned bioprocessing environments |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-302M |
| Detection Principles | Catalytic Combustion (LEL), Galvanic Cell (O₂), Electrochemical (H₂S, CO) |
| Detection Gases | Combustible Gas (CH₄), Oxygen (O₂), Hydrogen Sulfide (H₂S), Carbon Monoxide (CO) |
| Measurement Ranges | 0–100% LEL |
| 0–25 vol% (extended | 25.1–50 vol%) |
| 0–30 ppm (extended | 30.1–150 ppm) |
| 0–101 ppm (extended | 100–300 ppm) |
| Accuracy | ±2% LEL |
| Response Time | ≤25 s (1 m sampling tube) / ≤40 s (8 m sampling tube) |
| Operating Temperature | −10 °C to +40 °C, ≤95% RH |
| Power Supply | 4 × AA alkaline batteries |
| Continuous Operation | >8 h (20 °C, alarms/background light/data hold OFF) |
| Enclosure Rating | Intrinsic Safety (Ex ibd II BT3), LEL sensor: Flameproof (Ex d) |
| Dimensions | 152 × 152 × 42 mm (excl. protrusions) |
| Weight | ~870 g |
| Display | Backlit LCD (simultaneous 4-gas readout) |
| Alarms | 90 dB audible buzzer, flashing red LED, visual display alert |
| Key Functions | Auto backlight, flow-under detection (pressure sensor), battery/temperature/clock display, zero calibration, data hold, peak hold, alarm silencing, volume adjustment, alarm self-test |
| Standard Kits | 1-m or 8-m sampling hose configurations with filter/floating buoy, carrying case, or aluminum transport case with external alarm & AC adapter |
| Optional | Windows-compatible data logging kit (Windows 2000/XP) |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-308B |
| Detection Principle | Potentiostatic Electrolytic (with DNPH-coated filter for VOC interference reduction) |
| Measurement Range | 0.01–0.38 mg/m³ (service range: 0.39–3.00 mg/m³) |
| 0.01–0.30 ppm (service range | 0.31–3.00 ppm) |
| Sampling Method | Micro-pump–driven active aspiration |
| Measurement Duration Options | 10-min or 30-min integrated sampling modes |
| Display | Digital LCD with bar graph and status indicators |
| Power Supply | Six AA alkaline/manganese batteries or optional DC 9 V AC adapter |
| Battery Life | ~50 measurements (30-min mode) / ~100 measurements (10-min mode) using manganese batteries |
| Filter Lifetime | 50 measurements (30-min mode) / 100 measurements (10-min mode) at 0.10 mg/m³ average formaldehyde concentration |
| Operating Temperature | 5–40 °C |
| Dimensions | 175 × 140 × 86 mm (W × H × D) |
| Weight | Approx. 2.5 kg (including batteries) |
| Data Storage | 32 measurement records |
| Accessories Included | Three DNPH filter cartridges, six AA manganese batteries, sampling tube, ten particulate filter discs, tweezers |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3110 |
| Detection Principle | Catalytic Bead (Pellistor) |
| Detection Range | 0–10% LEL and 0–100% LEL (dual-range) |
| Display | 4-digit LCD with backlight |
| Accuracy | ±5% of full scale |
| Response Time (T90) | <3 seconds |
| Alarm Threshold | 20% LEL (audible/visual) |
| Power Supply | 4 × AA alkaline batteries (6 V DC) |
| Operating Temperature | 0 °C to +50 °C |
| Dimensions | 82 mm (W) × 162 mm (H) × 36 mm (D) |
| Weight | ~450 g (including batteries) |
| Sampling Method | Built-in micro diaphragm pump (active draw) |
| Certification | Intrinsically Safe (Ex ib IIB T4 Ga) |
| Compliance | JIS T 8201, JIS Z 8001, JIS C 0901, ATEX Directive 2014/34/EU (via representative EU importer), IEC 60079-0/-11 |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3140 |
| Weight | 450 g |
| Power Supply | AA alkaline batteries or dedicated rechargeable battery pack |
| Display | Dual-mode (digital + bar-graph) |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3160 |
| Detection Principle | Catalytic Bead (Contact Combustion) |
| Detection Method | Pump-Aspirated |
| Measurable Gases | Combustible gases & vapors of combustible organic solvents (e.g., diesel, propane, methane, hexane) |
| Range | 0–5000 ppm or 0–1 vol% (auto-ranging) |
| Accuracy | ±5% FS (H-range), ±10% FS (L-range) |
| Alarm Thresholds | 250 ppm / 500 ppm (user-selectable) |
| Display | Backlit LCD with dual-mode output — numeric (0–5000 ppm / 0–1 vol%) and bar-graph scale (auto-switching between L-range: 0–500 ppm / 0–1000 ppm and H-range: 0–5000 ppm / 0–1 vol%) |
| Alarm Output | Audible buzzer + red LED flash (gas/fault) |
| Intrinsic Safety Rating | Ex ib d IIB T3 (combined intrinsic safety + flameproof enclosure) |
| Operating Temperature | −20 °C to +50 °C |
| Power Supply | Four AA alkaline batteries or optional Ni–Cd rechargeable pack |
| Battery Life | ~20 h (alkaline, no alarm/backlight), ~5 h (Ni–Cd, no alarm/backlight) |
| Dimensions | 82 × 162 × 36 mm (W × H × D) |
| Weight | ~450 g (without batteries) |
| Data Logging | Internal memory (standard) |
| Flow Anomaly Self-Check | Yes |
| Accessories Included | Leather carrying case, 4 × AA alkaline batteries, 1 m sampling hose, filter cartridge, filter disc, stainless steel probe tube, rubber suction tip |
| Optional Accessories | Extended sampling hose, gas mixer, data download kit (CD-ROM + USB cable), Ni–Cd battery pack, charger |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-329M |
| Sensor Type | High-sensitivity tin oxide (SnO₂) sintered semiconductor |
| Display | 7-segment LED, 3.5-digit (000–999) |
| Measurement Range | 000–999 arbitrary odor units |
| Repeatability | ±5% ±1 digit (under identical conditions) |
| Sampling Method | Active aspiration (flow rate: 350 ± 100 mL/min) |
| Response Time (90%) | ≤20 s (with calibration odor) |
| Power Supply | 3 × AA alkaline batteries |
| Battery Life | Up to 10 h (at 25°C, typical use) |
| Operating Environment | 0–40°C, 10–80% RH (non-condensing) |
| Storage Environment | −10–50°C, ≤80% RH (non-condensing) |
| Dimensions (W×H×D) | 60 × 140 × 40 mm (excl. protrusions) |
| Weight | ≈300 g (incl. batteries) |
| Analog Output | DC 0–0.99 V (corresponding to 000–999 display) |
| Data Memory Capacity | 18,000 records |
| Included Accessories | Filter unit, 3 × AA alkaline batteries, set of 10 filter discs |
| Brand | FUJIKIN |
|---|---|
| Origin | Japan |
| Model | 112-605 |
| Power Supply | 100 V, 50/60 Hz AC |
| Maximum Stack Capacity | 25–30 sheets (64 g/m² paper) |
| Punch Cycle Time | 0.5 s per stroke (50/60 Hz) |
| Dimensions (W×D×H) | 277 × 436 × 308 mm |
| Weight | 37.7 kg |
| Die Block Compatibility | MOLE 605-112 |
| Compliance | Designed for GLP/GMP-aligned documentation integrity workflows |