Bioengineering Equipment
Filter
Showing 1531–1560 of 1942 results
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | PR-12 |
| Timer Range | 60 min |
| Oscillation Speed | 20–120 rpm |
| Oscillation Angle | 5°–8° (continuously adjustable) |
| Platform Dimensions | 150 × 150 mm |
| Max Load Capacity | 800 g (including fixture) |
| Power Supply | AC 100 V, 0.5 A |
| Net Weight | ~2.5 kg |
| Footprint | 170 × 180 × 166 mm (W × D × H) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Shake-LR / Shake-XR |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Speed | 15–160 rpm (Shake-LR), 15–100 rpm (Shake-XR) |
| Amplitude | 25 mm (Shake-LR), 20 mm (Shake-XR) |
| Temperature Operating Range | 0°C to +50°C |
| Platform Configuration | Single or dual platforms |
| Platform Dimensions | 300 × 200 mm |
| Max Load Capacity | ~2 kg (including platform and fixtures) |
| Display | Optional digital speed display |
| Power Supply | AC 100 V, 0.5 A |
| Dimensions (LR) | 300 × 270 × 152 mm |
| Dimensions (XR) | 300 × 235 × 155 mm |
| Weight | 7.8 kg (LR), 7.7 kg (XR) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | Shaker (LR, XR, Mix-VR, EVR, Wave-PR, SI, SI Slim, E-36, PR-12, NR-1 to NR-5100, SR-1/2DS/2DW, TS-10/20, SR-10, VIX-100) |
| Timing Range | 0–99 h 59 min |
| Oscillation Frequency | 5–2500 rpm |
| Oscillation Amplitude | 10–70 mm |
| Temperature Control | None |
| Platform Configuration | Single or dual-layer flat platforms |
| Key | Brand: TAITEC |
|---|---|
| Origin | Japan |
| Model | Shaker-LR |
| Oscillation Mode | Reciprocal / Rotary (switchable) |
| Speed Range | 20–160 rpm |
| Amplitude | 25 mm |
| Platform Dimensions | 300 × 200 mm |
| Operating Temperature Range | 0–50 °C |
| Max Load Capacity | ~2 kg (excl. platform & fixtures) |
| Power Supply | AC 100 V, 0.5 A |
| Weight | ~7.8 kg |
| Dimensions (W×D×H) | 300 × 270 × 152 mm |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | SR-1 |
| Oscillation Mode | Reciprocating |
| Speed Range | 50–250 rpm |
| Amplitude | 50 mm (fixed, optional 35 mm) |
| Timer Range | 60 min |
| Platform Options | 4 interchangeable platforms (A, B, C, E) |
| Max Load Capacity | ~7 kg (including platform) |
| Display | Digital speed readout |
| Power Supply | AC 100 V, 1 A |
| Dimensions | 570 × 435 × 247 mm (W × D × H) |
| Weight | ~45 kg |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | SR-10 |
| Oscillation Mode | Horizontal reciprocating |
| Speed Range | 50–250 rpm |
| Amplitude | 45 mm (fixed) |
| Timer Range | 1 min – 99 h 59 min |
| Platform Capacity | 1–3 stackable decks |
| Max Load per Deck | ~10 kg (excluding deck weight) |
| Dimensions (3-deck) | 740 × 438 × 435 mm (H) |
| Weight | ~70 kg |
| Power Supply | AC 100 V, 1 A |
| Standard Platform | C-type for 32 × 50 mL centrifuge tubes |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | SR-2ES |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Frequency | 50–300 rpm |
| Oscillation Amplitude | 40 mm |
| Capacity | Up to 192 tubes |
| Load Capacity | ~7.5 kg |
| Noise Level | ≤45 dB(A) |
| Power Supply | AC 220 V, 0.5 A |
| Dimensions (W×D×H) | 410 × 585 × 500 mm |
| Weight | ~49 kg |
| Oscillation Mode | Reciprocating (vertical/horizontal switchable) |
| Display | Digital speed & timer readout |
| Timing Modes | Continuous, Interval, Delay-start |
| Brand | TAITEC |
|---|---|
| Origin | China (Beijing) |
| Manufacturer Status | Authorized Distributor |
| Product Type | Separatory Funnel Shaker |
| Model | SR-2EW / SR-2ES / SR-2DW / SR-2DS |
| Timing Range | 1 min – 99 h 59 min |
| Oscillation Frequency | 50–300 rpm |
| Oscillation Amplitude | 40 mm |
| Number of Funnel Positions | 10 (dual-side configuration) |
| Noise Level | ≤45 dB(A) |
| Load Capacity per Side | 7.5 kg (including platform) |
| Dimensions (SR-2ES) | 410 × 585 × 500 mm |
| Dimensions (SR-2EW) | 410 × 760 × 500 mm |
| Weight (SR-2ES) | 49 kg |
| Weight (SR-2EW) | 57 kg |
| Power Supply | AC 220 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | TS-10 |
| Oscillation Mode | Reciprocating |
| Speed Range | 50–250 rpm |
| Amplitude | 45 mm (fixed) |
| Max Load Capacity | 10 kg (excluding platform) |
| Timer Function | Dual-stage timer (start time + runtime |
| Platform Compatibility | Interchangeable platforms for PE bottles, test tubes, flasks, vials, and mesh supports |
| Power Consumption | 70 W |
| Dimensions | 740 × 439 × 459 mm (H) |
| Weight | ~70 kg |
| Voltage | AC 100 V |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | TS-20 |
| Oscillation Mode | Reciprocating |
| Speed Range | 25–200 rpm |
| Amplitude | 10–50 mm (continuously adjustable) |
| Max Load Capacity | ~20 kg (excluding platform and clamping rods) |
| Timer Function | Dual independent timers (start time + runtime), up to 300 h total |
| Platform Configuration | Multi-plate compatible |
| Power Supply | AC 100 V, 1 A |
| Power Consumption | 70 W/h |
| Dimensions | 820 × 601 × 591 mm (H) |
| Weight | ~100 kg |
| Standard Accessories | Long clamping rods (×4), short clamping rods (×4), timer adjustment wrench |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | V·BR-36 |
| Instrument Type | Air-jacketed incubated orbital shaker |
| Timer Range | 60 min |
| Oscillation Speed | 50–500 rpm |
| Amplitude | 20 mm |
| Temperature Range | Ambient + 5°C to +60°C |
| Number of Platforms | 1 |
| Platform Dimensions | 240 × 200 mm |
| Internal Height | 165 mm |
| Max Load Capacity | 1 kg (including platform) |
| Heating Power | 80 W |
| Temp. Control Accuracy | ±0.3–1.0°C (at 25°C ambient) |
| Safety Features | Overheat protection, circuit breaker, lid-activated brake, sensor diagnostics |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VIX-100 |
| Timer Range | 15 min |
| Oscillation Speed | up to 2000 rpm |
| Platform Configuration | Single or Dual Shaking Plates |
| Operating Temperature | Ambient |
| Applicable Vessels | 20 mL glass vials (100 units), capped tubes up to 180 mm in length |
| Platform Dimensions | 325 × 325 mm |
| Power Supply | AC 100 V, 2 A |
| Weight | ~32 kg |
| Compliance | Designed for GLP-compliant sample preparation workflows |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VP-050N / VP-300N |
| Output Power | 50 W (VP-050N), 300 W (VP-300N) |
| Frequency Range | 19.5–20.5 kHz (VP-050N), 19–21 kHz (VP-300N) |
| Transducer Interface | Integrated horn-type piezoelectric converter with auto-tuning |
| Control | Digital LCD interface with real-time % output, current, temperature (*optional sensor), timer (1 s–120 min), and pulse mode (ON/OFF: 0.1–60 s) |
| Probe Options | Φ2 mm, Φ3 mm, Φ6 mm stepped microprobes (VP-050N) |
| Dimensions (W×D×H) | 122×288×283 mm (VP-050N), 143×360×283 mm (VP-300N) |
| Weight | 4.5 kg (VP-050N), 6.7 kg (VP-300N) |
| Power Supply | AC 100 V, 1 A (VP-050N), AC 100 V, 5 A (VP-300N) |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Wave-PR / Wave-SI / Wave-SI Slim |
| Oscillation Frequency | 5–50 rpm (Wave-PR), 10–60 rpm (Wave-SI & Wave-SI Slim) |
| Oscillation Angle | 2°–6° (adjustable, Wave-PR), 2°–10° (adjustable, Wave-SI), 6° (fixed, Wave-SI Slim) |
| Operating Temperature Range | 0 °C to +50 °C |
| Platform Quantity | 1 |
| Platform Dimensions | 300 × 200 mm (Wave-PR), 180 × 120 mm (Wave-SI), 180 × 130 mm (Wave-SI Slim) |
| Max Load Capacity | ~2 kg (excluding platform and fixtures) |
| Power Supply | AC 100 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | μT-01 |
| Disruption Principle | Horizontal umbrella-shaped oscillation |
| Speed Range | 2,500–4,600 rpm (6 preset steps) |
| Sample Volume | 2 mL |
| Sample Capacity | 1 tube per run |
| Compatible Beads | Glass, zirconia, stainless steel beads (φ0.15–6 mm), metal mortars |
| Operating Temperature | +5 to +35 °C |
| Vibration Frequency | 40–78 Hz |
| Timer Range | 5–60 s (6 presets) |
| Safety Features | Lid interlock stop, overload current protection |
| Dimensions | 172 × 280 × 160 mm (W × D × H) |
| Weight | ~5 kg |
| Power Supply | AC 100 V, 0.5 A |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | μT-12 |
| Instrument Type | Bead Mill Cell Disruptor |
| Operating Frequency | 53 Hz |
| Sample Capacity | 12 × 5.0 mL tubes |
| Throughput | 12 samples per run |
| Speed Range | 1,800–3,200 rpm (8-step digital adjustment) |
| Timer | 1–300 s (1-s increment, memory for 2 speed/time presets) |
| Safety Features | Lid-interlock shutdown, overload current protection |
| Dimensions | 310 × 400 × 200 mm (W × D × H) |
| Weight | ~15 kg |
| Power Supply | AC 100 V, 4 A |
| Ambient Operating Range | +5 °C to +35 °C |
| Tube Compatibility | Standard threaded 1.5/2.0 mL and 5.0 mL microtubes (e.g., Watson 1392-200, 2332-105) |
| Bead Compatibility | Stainless steel (SUS), zirconia, glass beads |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tankblot Eco-Maxi |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tankblot Eco-Mini |
| Pricing | Available Upon Request |
| Brand | Techne |
|---|---|
| Origin | United Kingdom |
| Model | MSC |
| Speed Range | 0–80 rpm |
| Speed Accuracy | < ±3 rpm |
| Soft-Start/Stop Ramp Time | 20 sec acceleration/deceleration |
| Intermittent Mode | On-time 6 sec–5 min, Off-time 2 min–2 hr |
| Operating Environment | ≤40°C, ≤95% RH (non-condensing) |
| Power Supply | Dual-voltage 110/230 V, 50/60 Hz |
| Power Consumption | 2 W |
| Fuse Rating | 100 mA |
| Compatible Vessels | Pyrex® borosilicate glass flasks (125 mL–5 L), with 2 or 5 side necks |
| Stirrer Platforms | MCS-101L (1×3–5 L), MCS-102L (2×1 L), MCS-104S (4×500 mL), MCS-104L (4×1 L), MCS-104XL (4×5 L) |
| Material | Stainless steel base, siliconized stir rods, borosilicate glass vessels |
| Brand | Telstar |
|---|---|
| Origin | Spain |
| Cabinet Type | Class II, Type A2 |
| Certification | EN 12469, TÜV-GS |
| External Dimensions (W×D×H) | 1354 × 759 × 1260 mm |
| Internal Work Area (W×D×H) | 1259 × 605 × 587 mm |
| Sash Opening Height | 200 mm |
| Downflow Velocity | 0.35 m/s |
| Downflow Volume | 882 m³/h |
| Noise Level | 58 dB(A) |
| Illumination | >1000 lux |
| Vibration | <0.005 mm RMS |
| Power Consumption | 1.6 kW |
| UV Lamp | Integrated, Timer-Programmable |
| Fluorescent Lighting | Integrated |
| HEPA Filtration Efficiency | ≥99.999% @ 0.12 µm and 0.3 µm (Supply & Exhaust) |
| Air Recirculation | 70% |
| Exhaust Ratio | 30% |
| Work Surface | Removable stainless steel tray |
| Cabinet Weight | 200 kg |
| Stand Height | 780 mm |
| Exhaust Port Diameter | 160 mm |
| ECO Mode | Yes (reduces downflow to 50%) |
| User Access Control | Dual-level password protection |
| Viewing Window | 10° inclined, anti-reflection, UV-protected tempered glass with bottom-edge unobstructed vision |
| Inlet Design | V-shaped front airfoil |
| Filter Accessibility | Front-accessible for rapid replacement |
| Brand | Telstar |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Custom-Built |
| Instrument Type | Class III Biological Safety Cabinet |
| External Dimensions (L×W×H) | Customizable |
| Internal Dimensions (L×W×H) | Customizable |
| Filter Efficiency (HEPA/ULPA) | ≥99.999% at 0.12 µm |
| Brand | Telstar |
|---|---|
| Origin | Spain |
| Model | Telstar Pura 2, Pura 3, Pura 4, Pura 3+, Pura 4+ |
| Air Classification | ISO Class 5 (EU GMP Grade A) in all chambers |
| Airflow | Unidirectional laminar flow (certified per ISO 14644-1) |
| Illumination | 700 lux (test chamber), 300 lux (transfer chamber) |
| Noise Level | <70 dBA |
| Inlet Filtration | HEPA H14 (99.997% @ 0.3 µm) |
| Exhaust Filtration | HEPA H14 (99.997% @ 0.3 µm) |
| Pre-filter | E10 |
| Bio-decontamination Efficacy | ≥6-log reduction of Geobacillus stearothermophilus spores |
| Sterility Test Pump | Integrated with standard Millipore (Merck) or Sartorius filtration units |
| Non-viable Particle Monitoring | APEX P5 portable airborne particle counter (dual-channel, 0.3/0.5 µm, 3000-record memory, 3.5" color touchscreen, stainless steel 304 housing) with LMS Express software (21 CFR Part 11 compliant) |
| Viable Microbial Monitoring | Sartorius MD8 airscan with gelatin membrane filtration |
| H₂O₂ Monitoring | In-chamber single-channel sensor (0–300 ppm) |
| Validation Support | FAT/SAT/DQ/IQ/OQ/PQ documentation templates available |
| Service | Global technical support via Telstar UK |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 3350 |
| Certification | DIN EN 12830:2018 |
| Communication | WLAN, LAN, testo UltraRange radio |
| Alarm | Visual LED alert (flashing) |
| Software Integration | testo Saveris PRO / CFR, testo Saveris Cockpit |
| Compliance | Supports 21 CFR Part 11 audit trail and GLP/GMP workflows |
| Power | Battery-operated (included) |
| Display | Built-in LCD |
| Sensor Type | Integrated NTC temperature sensor |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1751 |
| Measurement Range | -35 °C to +55 °C |
| Accuracy | ±0.5 °C (-35 °C to +55 °C) ±1 digit |
| Resolution | 0.1 °C |
| Memory Capacity | 1,000,000 readings |
| Battery Life | Up to 3 years (15-min interval, +25 °C) |
| Power Supply | 3 × AAA alkaline batteries |
| Protection Rating | IP65 |
| Dimensions | 89 × 53 × 27 mm |
| Weight | 130 g |
| Interface | Mini-USB port & SD card slot |
| Compliance | EN 12830, HACCP, EU Directive 2014/30/EU (EMC), RoHS 2011/65/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1753 |
| Temperature Range | −50 °C to +1000 °C (Type K), −50 °C to +400 °C (Type T) |
| Accuracy | ±0.5 °C (−50 to +70 °C), ±0.7 % of reading (+70.1 to +1000 °C for K |
| Resolution | 0.1 °C |
| Memory Capacity | 1,000,000 readings |
| Battery Life | Up to 3 years (15-min interval, +25 °C) |
| Power Supply | 3 × AAA alkaline batteries |
| IP Rating | IP65 |
| Dimensions | 96 × 54 × 29 mm |
| Weight | 130 g |
| Operating Temperature | −20 °C to +55 °C |
| Storage Temperature | −20 °C to +55 °C |
| Measurement Interval | 10 s – 24 h |
| Compliance | EU Directive 2014/30/EU (EMC), 2011/65/EU (RoHS) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 1843 |
| Measurement Range | −35 to +70 °C |
| Accuracy | ±0.5 °C |
| Resolution | 0.1 °C |
| Response Time (t₉₀) | 30 min |
| Logging Interval | 1 min to 24 h |
| Memory Capacity | 40,000 readings |
| Battery Life | 500 days (at 25 °C, 15-min interval) |
| Weight | 44 g |
| Dimensions | 97 × 12 × 40 mm (L×W×H) |
| Enclosure Material | ABS |
| IP Rating | IP67 |
| Display | Single-line segment LCD |
| Interface | USB Type-A, NFC |
| Compliance | EN 12830, CE 2014/30/EU, DIN EN 61326-1:2013, DIN EN 50581:2013, FDA 21 CFR Part 11 (with testo ComSoft CFR software), HACCP, GxP |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 1901 |
| Compliance | 21 CFR Part 11 compliant software platform |
| System Requirements | Windows 7 (32/64-bit), Windows 8, Windows 10 or newer |
| Included Software | testo 190 CFR Software (locally installed, registration required) |
| Maximum Simultaneous Loggers | 8 (programming & readout), 254 (validation-scale data aggregation) |
| Key Functionality | F₀ calculation, photo-annotation of measurement locations, graphical + tabular data visualization, audit-trail-enabled reporting |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 190-P1-CFR |
| Absolute Pressure Range | 1 mbar to 4 bar abs |
| Accuracy | ±20 mbar |
| Resolution | 1 mbar |
| Response Time (t₉₀) | 0.2 s |
| Memory Capacity | 60,000 measurements |
| Measurement Interval | 1 s – 24 h |
| Operating Temperature | 0 – 140 °C |
| Storage Temperature | −20 – +50 °C |
| Housing Material | Stainless steel body with PEEK battery cap |
| Ingress Protection | IP68 |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 operating hours (10 s cycle at +121 °C) |
| Dimensions | Ø22 × 83 mm |
| Channel Count | 1 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 191 |
| Type | Integrated Temperature Validation System for Sterilization, Pasteurization & Lyophilization Processes |
| Compliance | Designed for HACCP, FDA 21 CFR Part 11 (with optional audit trail), ISO/IEC 17025-supporting workflows, EN 12830, ASTM F1783, and EU Annex 15 (Qualification of Aseptic Processes) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 191-P1-HACCP |
| Absolute Pressure Range | 1 mbar to 4 bar abs |
| Accuracy | ±20 mbar |
| Resolution | 1 mbar |
| Response Time (t₉₀) | 0.2 s |
| Operating Temperature | 0 °C to 140 °C |
| Storage Temperature | −20 °C to +50 °C |
| IP Rating | IP68 |
| Dimensions | Ø22 mm × 83 mm |
| Battery | 1/2 AA lithium |
| Battery Life | 2,500 h (at 10 s measurement interval, +121 °C) |
| Memory Capacity | 60,000 measurements |
| Measurement Interval | 1 s to 24 h |
| Interface | USB |
| Enclosure Material | Stainless steel housing with PEEK battery cap |