| Brand | Atonarp |
|---|---|
| Origin | Japan |
| Model | AST3007 |
| Mass Range | 2–285 amu |
| Resolution | 0.8 ± 0.2 (FWHM) |
| Detection Limit | 0.1 ppm |
| Sampling Speed | High-speed dynamic acquisition |
| Sensitivity | Sub-ppb for key process gases |
| Vacuum System | Turbomolecular pump |
| Detector | Faraday Cup / Secondary Electron Multiplier (FC/SEM) |
| Operating Temperature | 15–35 °C |
| Power Consumption | 350 W |
| Dimensions (L×W×H) | 299 × 218 × 331 mm |
| Weight | 15 kg |
| Brand | Atonarp |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aston™ Process Mass Spectrometer |
| Pricing | Available Upon Request |
| Brand | Atonarp |
|---|---|
| Origin | Japan |
| Model | Aston™ |
| Application Domain | In-line Process Mass Spectrometry for Semiconductor Vacuum System Integrity Monitoring |
| Compliance Context | Designed for ISO 9001-certified semiconductor fabs |
| Environmental Rating | IP65-rated enclosure |
| Brand | Ambrell |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Induction Heating Systems |
| Model Series | EKOHEAT® 10/100 to EKOHEAT® 270/100 |
| Frequency Range | 50–150 kHz |
| Input Voltage | 360–520 V AC, 3-phase |
| Power Output Range | 10 kW to 270 kW |
| Input Apparent Power | 12 kVA to 300 kVA |
| Core Architecture | Variable Power Architecture (VPA) |
| Control Software | eVIEW® with real-time temperature monitoring and data logging |
| Compliance | Designed for industrial environments compliant with UL 508A, CE, and RoHS |
| Brand | Ambrell |
|---|---|
| Origin | USA |
| Model | EASYHEAT 0112 |
| Maximum Power | 1.2 kW |
| Operating Frequency | 150–400 kHz |
| Input Voltage | 105–129 V / 198–250 V, Single-Phase |
| Input Apparent Power | 1.6 kVA |
| Heating Method | Non-contact electromagnetic induction |
| Application Type | Atmospheric (non-vacuum), rapid thermal annealing for conductive materials |
| Brand | Ambrell |
|---|---|
| Origin | USA |
| Model | 0112 |
| Frequency Range | 150–400 kHz |
| Power Output | 1–10 kW |
| Power Control Resolution | ±25 W |
| Cooling | Integrated Water-Cooling System |
| Heating Head Cable Length | Standard 3 m (extendable) |
| Display Languages | English, French, Italian, German, Spanish |
| Compliance | CE, UL Listed |
| Remote Interface | RS-232/RS-485 Serial Port |
| Programmable Profiles | Up to 4 user-defined heating modes |
| Optional Accessories | Optical Pyrometer (for closed-loop temperature control), Chiller/Heat Exchanger, PLC Interface Module, Foot Switch, Extended Cable Kits |
| Brand | Ambrell |
|---|---|
| Origin | USA |
| Manufacturer Type | Industrial Induction Heating System Manufacturer |
| Model | EkoHeat Series (Custom-Configured) |
| Power Rating | 6 kW (typical for lab-scale silicon melting) |
| Operating Frequency | 196 kHz |
| Compliance | CE, UL 508A, RoHS |
| Application Scope | Lab-scale to pilot-scale non-contact induction melting |
| Sample Capacity | 0.7 g to >100 kg (configurable) |
| Crucible Compatibility | Graphite, quartz, ceramic, refractory-lined |
| Thermal Control Precision | ±5 °C (with integrated thermocouple feedback loop) |
| Cooling | Integrated forced-air or optional water-cooling |
| Software Interface | EkoControl™ v4.2 with real-time power/temperature logging and recipe management |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | Calibration System Pro |
| Calibration Range | 1013 hPa to 10⁻³ hPa |
| Flange Configuration | PS A30 110 (4×DN 16 ISO-KF, 2×DN 25 ISO-KF, 1×DN 40 ISO-KF, 1×DN 40 CF) / PS A30 111 (5×DN 16 ISO-KF, 2×DN 25 ISO-KF, 2×DN 40 ISO-KF) |
| Nitrogen Pumping Speed | 67 L/s |
| Forevacuum Pump Speed (50 Hz) | 2.5 m³/h |
| Ultimate Pressure | < 1 × 10⁻⁷ hPa |
| Gas Flow Control Range | 5 × 10⁻⁶ to 1 × 10³ hPa·L/s |
| Operating Temperature | +5 °C to +40 °C (cooling-dependent) |
| Weight | 66 kg (standard configuration) |
| Dimensions (L×W×H) | 700 × 639 × 593 mm |
| Compliance | ISO 3567, DAkkS-DKD-R 6-2, EN ISO 12100, EN 60204-1, CE (2006/42/EC & 2014/30/EU) |
| Brand | Kaufman & Robinson, Inc. (KRI) |
|---|---|
| Origin | USA |
| Model | EH 3000 HC |
| Discharge Voltage/Current | 50–300 V / up to 20 A |
| Beam Divergence (HWHM) | >45° |
| Cooling | Water-cooled |
| Compatible Gases | Ar, Xe, Kr, O₂, N₂ |
| Dimensions | Ø9.7" × H6" |
| Application | IBAD for high-density, uniform optical thin-film deposition |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM-2000 |
| Detection Principle | Helium Mass Spectrometry (Quadrupole) |
| Measurement Methods | Vacuum Mode & Sniffer Mode |
| Quantitative Sensitivity (Vacuum Mode) | 1×10⁻⁸ – 1×10⁻⁵ mbar·L/s |
| Qualitative Sensitivity (Sniffer Mode) | >1×10⁻⁵ mbar·L/s |
| Calibration | Automatic, traceable to NIST-certified standard leak |
| Operating Temperature | 15–25 °C |
| Relative Humidity | 30–80 % RH |
| Power Supply | 90–250 V AC, 50–60 Hz |
| Typical Power Consumption | 3,750 W |
| Compressed Air (ISO 8573-1 Class 1.3.1) | 4.5–10 bar(g) |
| Helium Supply Pressure | 0.5–8 bar(g) |
| Nitrogen Supply Pressure | 0.5–8 bar(g) |
| User Interface | 10" multi-touch full-HD color display |
| Software | GMP-compliant Windows 10 OS with 4-tier user access control, PDF report generation (test, calibration, audit trail), FDA 21 CFR Part 11 readiness |
| Connectivity | 1× LAN, 2× USB 3.0, 1× HDMI |
| Dimensions (L×W×H, incl. trolley) | 1,409 × 575 × 1,194 mm |
| Weight (incl. trolley) | 140 kg |
| Acoustic Noise Level | <53 dB(A) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | OmniControl |
| Measurement Principle | Vacuum Pressure Monitoring and Pump Control via RS-485 and Analog Interfaces |
| Enclosure Rating | IP20 |
| Operating Temperature | 0°C to +50°C |
| Power Supply Options | 100–240 V AC ±10%, 47–63 Hz |
| Power Consumption | 300 W (OmniControl 200) / 411 W (OmniControl 300) / 522 W (OmniControl 400) |
| Output Voltages | 24 V DC (200/300) or 48 V DC (400) |
| Max Output Current | 11.4 A (200) / 15 A (300) / 8.33 A (400) |
| Display | 3.5-inch capacitive touchscreen |
| Mounting Options | Rack-mountable, desktop, or portable configurations |
| Compliance | Designed for integration with Pfeiffer Vacuum RS-485–enabled pumps (HiPace, HiScroll, HiLobe, MVP) and digital vacuum gauges |
| Brand | NS |
|---|---|
| Origin | Japan |
| Model | 4 IBE |
| Sample Holder | 4" φ, single wafer |
| Ion Incidence Angle | 0° to ±90° |
| Ion Source | KDC-40 Kaufman-type (KRI, USA) |
| Base Pressure | ≤1×10⁻⁴ Pa |
| Turbomolecular Pump | Pfeiffer, 350 L/s |
| Etch Uniformity | ≤±5% |
| Cooling | Direct substrate cooling |
| Motion Control | Planetary rotation (rotation + revolution) |
| Gas Compatibility | Ar, O₂, N₂, CF₄, Xe, and mixed process gases |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany (manufactured in Germany, distributed globally) |
| Model | ASM 340 |
| Detection Principle | Quadrupole Mass Spectrometry with Helium Carrier Gas |
| Minimum Detectable Leak Rate | ≤5 × 10⁻¹² mbar·L/s (helium) |
| Operating Mode | Positive-Pressure Sniffing & Vacuum-Coupled Testing |
| Pumping System | Integrated Turbomolecular Pump + Forepump |
| Mass Filter | 4-amu Resolution Quadrupole Analyzer |
| Response Time | <100 ms (typical) |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface | RS-232, Ethernet, Analog Output (0–10 V) |
| Software Compatibility | Pfeiffer VacuGraph® PC Control Suite |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | Germany |
| Model | ModuLine Gauge |
| Interface Options | PROFIBUS |
| Sensor Types | Capacitance Manometer (TPR series), Cold Cathode Ionization Gauge (IKR series) |
| Operating Temperature Range | –40 °C to +80 °C |
| Weight | 0.14–0.65 kg |
| Vacuum Range | 10⁻¹¹ mbar to 10³ mbar (depending on sensor module) |
| Sealing | Metal-sealed variants available |
| Radiation & EMI Resistance | Yes |
| Application Domain | Particle accelerator beamlines, UHV/XHV research systems, industrial vacuum process monitoring |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ASM 340WET |
| Detection Principle | Helium-Specific Quadrupole Mass Spectrometry |
| Operating Mode | Vacuum (Hard-Line) Mode |
| Pumping Configuration | Integrated with ACP 28 Dry Scroll Vacuum Pump |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Interface | RS-232 / Ethernet (Optional), Analog Output (0–10 V) |
| Minimum Detectable Leak Rate | ≤5 × 10⁻¹² mbar·L/s (He) |
| Response Time | < 0.5 s (typical) |
| Mass Filter | Quadrupole with 4 amu resolution at 4 He peak |
| Brand | Ambrell |
|---|---|
| Origin | USA |
| Model | EasyHeat |
| Frequency Range | 150–400 kHz |
| Power Output | 1.2–10.0 kW |
| Input Voltage | 105–250 V (1-phase) / 187–520 V (3-phase) |
| Input Apparent Power | 1.6–12.4 kVA |
| Compliance | CE, UL Listed, RoHS Compliant |
| Software | eVIEW™ Process Monitoring & Control Suite |
| Architecture | Versatile Platform Architecture (VPA) |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASM 142 S |
| Detection Limit (He) | 1 × 10⁻⁸ Pa·m³/s |
| Measurement Range (He) | 1 × 10⁻⁷ to 1 mbar·L/s |
| Forepump | Oil-Sealed Rotary Vane Pump |
| Detectable Gas | ⁴He |
| Operating Temperature | 0–45 °C |
| Acoustic Noise Level | < 57 dB(A) |
| Dimensions (W × D × H) | 517 × 357 × 420 mm |
| Warm-up Time | 2 min |
| Detection Mode | Sniffer (Probe-Based) |
| Weight | 55 kg |
| Standard Probe | 5 m Flexible Hose with 9 cm Rigid Nozzle |
| Power Supply Options | 110–130 V AC (North America) or 200–240 V AC (Europe) |
| Interface | RS-232 / USB / Optional PLC Integration |
| Display Language Options | English, French, German, Chinese |
| Brand | Pfeiffer Vacuum |
|---|---|
| Origin | France |
| Model | ACP 120 |
| Pump Type | Oil-Free Dry Scroll Vacuum Pump |
| Ultimate Pressure | ≤3 × 10⁻² mbar |
| Pumping Speed | 95 m³/h |
| Motor Power | 3 kW |
| Noise Level | <65 dB(A) |
| Weight | 205 kg |
| Inlet Flange | DN 50 |
| External Dimensions (L×W×H) | 1000 × 600 × 700 mm |
| Maintenance Interval | ~17,000 operating hours |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |