Bio-Rad
Filter
Showing 1–30 of 55 results
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Bio-Plex 200 |
| Configuration | Complete system with dual-laser detection, magnetic bead handling, and integrated fluidics |
| Detection Principle | xMAP® (x-MAP) technology based on fluorescently encoded microspheres |
| Multiplex Capacity | Up to 500 analytes per well |
| Sample Format | 96-well or 384-well microplate |
| Detection Lasers | 532 nm (reporter) and 635 nm (classification) |
| Sensitivity | Sub-picogram/mL range for cytokines (typical) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Bio-Plex 200 (with HTF) |
| Regulatory Classification | Imported Instrument for In Vitro Diagnostic Use |
| Platform Technology | xMAP® Luminex-based Bead-Based Suspension Array |
| Detection Method | Dual-Laser Flow Cytometric Analysis (532 nm excitation / 635 nm classification + 532 nm excitation / 585 nm emission) |
| Sample Format | 96-well or 384-well microplate |
| Multiplex Capacity | Up to 500-plex per well |
| Sensitivity | Sub-picogram/mL range (varies by analyte and assay configuration) |
| Dynamic Range | ≥3–4 logs |
| Throughput | Up to 96 samples per run (standard plate) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Bio-Plex 3D |
| Pricing | Available Upon Request |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Bio-Plex Pro |
| Instrument Type | Dedicated Microplate Washer |
| Wash Head Configuration | 8-channel |
| Rinse Needle Design | Single-needle per channel |
| Wash Fluid Channels | 8 independent wash fluid channels |
| Waste Aspiration Channels | 8 independent waste aspiration channels |
| Soak Time | Programmable, dynamic control |
| Wash Cycles | Programmable, dynamic control |
| Residual Volume per Well | <4 µL |
| Orbital Shaking Function | Yes |
| Plate Carrier | Integrated magnetic plate carrier for xMAP®-based assays (including MagPlex®) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Bio-Plex Protein Array System |
| Excitation Lasers | 532 nm & 635 nm |
| Sensitivity | <10 pg/mL |
| Inter- and Intra-Assay CV | <10% |
| Dynamic Range | 1–32,000 pg/mL |
| Recovery Rate | Serum 80–120%, Cultured Cells 90–110% |
| Throughput | 96 samples in 30 minutes (up to 9,600 data points) |
| Sample Volume | 12 µL per well |
| Plate Format | Standard 96-well microplate |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ 384-Well |
| Instrument Type | Gradient Thermal Cycler |
| Sample Capacity | 384-well plate |
| Max Heating Rate | 2.5 °C/s |
| Temperature Accuracy | ±0.2 °C at 90 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 s at 90 °C |
| Temperature Gradient Range | 1–24 °C across 12 columns |
| Gradient Accuracy | ±0.2 °C (last column) |
| Operating Temperature Range | 0–100 °C |
| Input Power | 850 W max |
| Display | 8.5-inch color LCD touchscreen |
| Onboard Memory | >1,000 protocols |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ 96 Deep Well |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 1–96 wells (0.2 mL tubes or 96-well plates) |
| Max Heating Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Heating/Cooling Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 sec at 90°C |
| Temperature Gradient Range | 30–100°C |
| Gradient Accuracy (last column) | ±0.2°C |
| Column-wise Uniformity | ±0.4°C within 10 sec at 90°C |
| Input Power | 850 W max |
| Display | 8.5" color LCD touchscreen |
| Onboard Memory | >1,000 protocols |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | C1000 Touch™ Dual 48 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 2 × 48 × 0.2 mL tubes or 2 × 48-well plates |
| Max Heating Rate | 4°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Temperature Gradient Range | 1–24°C (30–100°C) |
| Gradient Accuracy | ±0.2°C (last column) |
| Gradient Uniformity per Column | ±0.4°C within 10 s |
| Input Power | 850 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX Connect |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well (0.2 mL tubes) |
| Maximum Heating Rate | 5 °C/s (adjustable from 0.1 to 5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Sources | 3 LEDs (450–535 nm) |
| Emission Detection Range | 3 Photodiodes (515–580 nm) |
| Gradient PCR | Yes, range 30–100 °C, max ΔT = 24 °C |
| High-Resolution Melting (HRM) Support | Yes |
| Connectivity | USB |
| Dimensions (W×D×H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Duet |
| Detection Channels | 2 + FRET |
| Temperature Uniformity | ±0.3°C across 96-well block |
| Gradient Range | Up to 24°C |
| Software | CFX Maestro (including FDA 21 CFR Part 11-compliant Security Edition) |
| Included License | qbase+ Advanced Analysis Module |
| Optical System | Solid-State Scanning Optical Shuttle |
| Calibration | Factory-calibrated for common dyes (FAM, HEX, VIC, ROX, Cy5, etc.) |
| Compatibility | Full compatibility with Bio-Rad PrimePCR Assays and SsoAdvanced Supermixes |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus 384 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 384-well format |
| Heating Rate | 2.5 °C/sec |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.3 °C |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus 96 |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.3°C |
| Optical Configuration | Individual well excitation and detection with FRET-capable channels |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | CFX Opus Deepwell |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 2.5°C/sec |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.4°C |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX384 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 384-well format |
| Maximum Heating Rate | 2.5 °C/s (adjustable from 0.1 to 2.5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Range | 5 LEDs (400–650 nm) |
| Emission Detection Range | 5 Photodiodes (515–690 nm) |
| Supported Applications | Absolute Quantification, Gene Expression Analysis, SNP Genotyping, HRM (High-Resolution Melting), Multiplex Detection (up to 4 targets per well) |
| Software | CFX Maestro Secure Edition (21 CFR Part 11 compliant, audit trail, user access control) |
| Thermal Block | Integrated C1000 Touch thermal cycler engine |
| Gradient PCR | Yes, 30–100 °C range, max ΔT = 24 °C |
| Dimensions (W × D × H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg (47 lb) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX96 Touch |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well (0.2 mL tubes) |
| Max Heating Rate | 5 °C/s (adjustable from 0.1 to 5 °C/s) |
| Temperature Accuracy | ±0.2 °C at 90 °C setpoint |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 seconds after reaching 90 °C |
| Excitation Range | 6 LEDs (450–684 nm) |
| Emission Detection Range | 6 Photodiodes (515–730 nm) |
| Gradient PCR | Yes, 30–100 °C, max ΔT = 24 °C |
| High-Resolution Melting (HRM) Support | Yes |
| Interface | USB |
| Dimensions (W×D×H) | 33 × 45.7 × 35.6 cm |
| Weight | 21 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ChemiDoc Go |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 20 MP (physical pixels) |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | Fixed-focus f/0.95 lens |
| Excitation Sources | Transmitted UV (302 nm), Transmitted Blue Light (470 nm, optional), Transmitted White Light (optional), Reflected UV (365 nm), Reflected Green Light (530 nm) |
| Emission Filters | 520/26 nm BP, 590/110 nm BP, 695 nm LP |
| Dual-Channel Fluorescence | StarBright 520 nm & 700 nm channels |
| Regulatory Status | For research use only (RUO), not for clinical diagnostic use |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | ChemiDoc |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 6.1 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 1-inch |
| Detection Sensitivity | fg-level protein |
| Signal-to-Noise Ratio | >56 dB |
| Lens | Fixed-focus |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | ChemiDoc MP |
| Instrument Type | Multicolor Fluorescent Gel Imaging System |
| CCD Resolution | 6.1 Megapixels |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 1-inch |
| Detection Sensitivity | Sub-femtogram (fg) for Proteins |
| Signal-to-Noise Ratio | >56 dB |
| Lens | Fixed-Focus Optical Lens |
| Imaging Modalities | Chemiluminescence, Multiplex Fluorescence (RGB + Dual NIR), UV Transillumination, White Light Reflection |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ChemiDoc XRS+ |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 4 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 1-inch |
| Detection Sensitivity | pg–fg level for proteins |
| Signal-to-Noise Ratio | >56 dB |
| Lens | Motorized Zoom Lens |
| Imaging Modes | Chemiluminescence, Fluorescence (single/dual-color), Colorimetric, Densitometry |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | GelDoc Go |
| Imaging Sensor | 6.3 MP monochrome CCD |
| Light Sources | Dual-mode transilluminator (UV 302 nm + blue light 470 nm) |
| Safety Features | Integrated blue-light–optimized optics, included amber safety goggles |
| Imaging Modes | UV transillumination, blue-light transillumination, white-light reflection |
| Fluorescence Compatibility | SYBR Safe, SYBR Gold, Ethidium Bromide (EtBr), GelRed, GelGreen, and other nucleic acid dyes |
| Software | Image Lab Touch™ (touchscreen interface, one-touch capture, auto-exposure, ROI analysis, molecular weight estimation, lane/band quantification) |
| Regulatory Compliance | CE, FCC, RoHS compliant |
| Intended Use | Benchtop gel documentation, nucleic acid and protein gel imaging, blue-light–mediated excision, academic and QC laboratory applications |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | GelDoc Go Blue-Light Safe Gel Imaging System |
| CCD Resolution | 6.3 MP |
| Bit Depth | 16-bit |
| Dynamic Range | 0–4.8 OD |
| Light Sources | Dual-mode transilluminator (UV 302 nm + Blue Light 470 nm) |
| Safety Configuration | Integrated blue-light excitation with amber safety goggles |
| Instrument Type | Benchtop gel documentation system |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | GelDoc Go |
| Instrument Type | Standalone Gel Documentation System |
| CCD Resolution | 6.3 MP |
| Bit Depth | 16-bit |
| Dynamic Range | >3.5 OD |
| CCD Sensor Size | 1-inch |
| Lens | Fixed-focus QuickSight™ Optical Lens |
| Display | 9.7-inch Capacitive Touchscreen |
| Connectivity | Integrated standalone operation (no PC required) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | GelDoc XR+ |
| Instrument Type | Standard Gel Documentation System |
| CCD Resolution | 4.0 Megapixels |
| Bit Depth | 12-bit |
| Dynamic Range | 0–3.6 OD |
| CCD Sensor Size | 2/3-inch |
| Detection Sensitivity | 0.1 ng DNA stained with ethidium bromide (EB) |
| Signal-to-Noise Ratio | >56 dB |
| Lens | Motorized Optical Zoom Lens (8.5–51 mm focal length) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Gene Pulser Xcell |
| High Voltage Range | 3000 V |
| Low Voltage Range | 10 V |
| Pulse Duration | 0.05–10 ms (0.05 ms increments) for 10–500 V |
| Number of Pulses | 1–10 (0.1–10 s interval for 10–500 V) |
| Capacitance | 25–3275 µF (25 µF increments) at 10–500 V |
| Resistance | 50–1000 Ω (50 Ω increments) + ∞ |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | GS-900 |
| Instrument Type | Standard Gel Imaging System |
| Bit Depth | 16-bit |
| Optical Density Range | 0.0 to 3.4 OD |
| Illumination Source | LED-based scanning (400–750 nm) |
| Imaging Modes | Transmission and Reflectance |
| Scan Area | 29 × 33 cm |
| Effective Resolution | Adjustable, down to 36.3 µm |
| Image Acquisition Platform | Sealed, humidity-tolerant chamber with adjustable transparent lid |
| Software | Image Lab™ v6.x or later (FDA 21 CFR Part 11 compliant configuration available) |
| Brand | Bio-Rad |
|---|---|
| Model | Helios |
| Origin | USA |
| Type | Handheld Particle-Mediated Gene Delivery System |
| Operating Pressure Range | 100–600 psi |
| Safety Relief Valve Setpoint | 700 ± 35 psi |
| Max. Helium Pressure Adjustment | 800 psi |
| Power Supply | 9 V Alkaline Battery (rechargeable optional) |
| Battery Life | ≥1,000 discharges |
| Max. Discharge Current | 10 mA (gun unit) |
| Input Voltage | 100–120 V or 220–240 V AC, 50/60 Hz |
| Cartridge Spinning Speed | 30 rpm |
| Gold Particle Diameters | 0.6, 1.0, and 1.6 µm |
| PVP Coating Mass | 0.5 g per kit |
| Desiccant | Spherical drying agent (5 units) |
| Cartridge Capacity | 12 firings per chamber |
| Kit Contents | 1,000 pre-loaded cartridges, 50 ft (~26 m) gold-coated tubing, 5 gene storage vials |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | iQ-Check Prep |
| Application | Automated DNA extraction and qPCR master mix dispensing for food & environmental pathogen testing |
| Throughput | Up to 500 samples in ≤8 hours (when integrated with compatible qPCR instruments) |
| System Integration | Designed for seamless workflow coupling with Bio-Rad CFX series or other open-platform real-time PCR systems |
| Regulatory Context | Supports GLP-compliant documentation practices |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | MicroPulser |
| High Voltage Range | 300–3000 V |
| Low Voltage Range | 200–2500 V |
| Pulse Duration | 0.1–5.0 ms (adjustable in 0.1 ms increments) |
| Capacitance Settings | 100, 250, 500, and 1000 µF |
| Internal Resistance | Fixed ~100 Ω (optimized for standard electroporation cuvettes) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Discover |
| Flow Rate Options | 10 mL/min (0–3650 psi) or 100 mL/min (0–1450 psi) |
| Buffer Blending | On-line gradient mixing with auto-buffer preparation valve system (2× flow boost: up to 20 mL/min for F10, 200 mL/min for F100) |
| UV Detection | Optional single-wavelength detector (255 nm / 280 nm) or full-spectrum diode array detector (190–800 nm, 4-channel simultaneous acquisition) |
| Software | ChromLab™ with integrated touchscreen interface |
| Sample Handling | Integrated autosampler valve |
| Fraction Collection | Optional BioFrac fraction collector |
| Modularity | Fully configurable with selectable valves (injection, column switching, effluent diversion), mixing chambers, and rack-mounted expansion modules |
| Compliance | Designed for GLP/GMP-aligned workflows |