| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Quest 10 |
| Flow Rate | 0–10 mL/min |
| Maximum Pressure | 3650 psi |
| Buffer Blending | Integrated Auto-Buffering Valve System (up to 20 mL/min effective flow) |
| UV Detection Options | Single-wavelength (255 nm / 280 nm) or Full-spectrum (190–800 nm, 4-channel simultaneous detection) |
| Software | ChromLab™ with touchscreen interface |
| Automation Modules | Optional sample/injection valves, column switching valves, fraction collection (BioFrac™), and outlet valves |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | Scout |
| Flow Rate Options | 10 mL/min (max. 3650 psi) or 100 mL/min (max. 1450 psi) |
| Buffer Blending | On-line gradient mixing with auto-buffer preparation valve system (2× flow boost: up to 20 mL/min for F10, 200 mL/min for F100) |
| UV Detection | Optional single-wavelength detector (255 nm / 280 nm) or full-spectrum diode array detector (190–800 nm, 4-channel simultaneous acquisition) |
| Software | ChromLab™ with integrated touchscreen interface |
| Sample Handling | Integrated autosampler valve |
| Fraction Collection | Optional BioFrac™ square-format fraction collector |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | PDS-1000/HE |
| Helium Pressure Range | 450–2200 psi |
| Vacuum Chamber | Adjustable to ≤29 inHg (737 mmHg) |
| Carrier Disk Diameter | 13 mm |
| Stopping Screen Material | Stainless Steel Mesh (100 µm pore) |
| Microprojectile Size Compatibility | 0.6–1.6 µm (Au or W) |
| Pulse Duration | <1 ms (transient helium shockwave) |
| Capacitance | Not applicable (gas-driven, non-electrical acceleration) |
| Resistance | Not applicable (pneumatic system) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | i12 |
| Instrument Type | Transfer Electrophoresis System |
| Main Unit | Electrophoresis Apparatus with Casting/Running Tank |
| Gel Length Range | 7–24 cm |
| Sample Capacity | 12 independent lanes |
| Maximum Voltage | 10,000 V |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTC Tempo |
| Instrument Type | Standard Thermal Cycler |
| Sample Capacity | 96-well, 384-well, 48/48 dual-block |
| Heating Rate | 5°C/s |
| Temperature Accuracy | ±0.2°C (measured at 90°C) |
| Well-to-Well Temperature Uniformity | ±0.4°C (measured at 90°C) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | QX Continuum™ |
| Instrument Type | Digital PCR System |
| Sample Throughput | 96-well format |
| Certified Performance | NMI-traceable reference material validation |
| Droplet Generation | >20,000 droplets per 16 µL sample |
| Multiplexing Capacity | Up to 4 targets per well |
| Thermal Zones | Up to 8 independent temperature zones per plate |
| Software | QX Insight Analysis Software |
| Regulatory Status | For Research Use Only (RUO), not for clinical diagnostic use |
| Compliance | Designed to support GLP/GMP-aligned data integrity practices |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QX ONE |
| Instrument Type | Digital PCR System |
| Sample Throughput | 32–480 wells per run |
| Heating Rate | 2.5 °C/s |
| Temperature Accuracy | ±0.2 °C (at 90 °C) |
| Well-to-Well Temperature Uniformity | ±0.4 °C (at 90 °C) |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | QX200 |
| Instrument Type | Digital PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 0.1–5.0°C/s (typical setting: 2.0°C/s) |
| Temperature Accuracy | ±0.2°C (at 90°C) |
| Well-to-Well Temperature Uniformity | ±0.4°C (at 90°C) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Instrument Type | Digital PCR System |
| Model | QX600 |
| Detection Channels | 6-color (FAM, HEX, Cy5, Cy5.5, ROX, ATTO 590) |
| Multiplex Capacity | up to 12-plex per well (CNV applications) |
| Limit of Detection | <0.1% mutant allele frequency |
| Quantification Precision | ±10% CV |
| Regulatory Compliance | FDA 21 CFR Part 11 (Advanced Software), GLP/GMP-ready audit trail |
| Platform Compatibility | Fully compatible with Manual DG and AutoDG droplet generators |
| Assay Support | TaqMan probe-based and EvaGreen dye-based ddPCR assays |
| Certification | Traceable calibration verified by Australia’s National Measurement Institute (NMI) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QX700™ E |
| Instrument Type | Digital PCR System |
| Sample Throughput | 48-well |
| Detection Channels | 7-color multiplexing |
| Sample Input Volume | 5 µL per reaction |
| Droplets per Sample | ≥17,000 |
| Automation Level | Fully integrated, walk-away operation |
| Run Time for 48 Samples | 2.5 hours |
| Chip Format | Single disposable cartridge accommodating up to 48 samples |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | QX700™ HT |
| Instrument Type | Digital PCR System |
| Sample Throughput | 384-well format |
| Detection Channels | 7-color multiplexing |
| Sample Input Volume | 5 µL |
| Effective Droplets per Sample | ≥17,000 |
| Automation Level | Fully integrated workflow (droplet generation, thermal cycling, and fluorescence reading) |
| Max. Chip Capacity per Run | 2 microfluidic chips |
| Time to Result | ≤2.5 hours for 96 samples |
| Time to Result | ≤8 hours for 384 samples |
| On-demand Loading | Yes, with independent thermal control per 16-well chip segment |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QX700™ S |
| Instrument Type | Digital PCR System |
| Sample Throughput | 192-well format |
| Detection Channels | 7-color simultaneous detection |
| Sample Input Volume | 5 µL |
| Effective Droplet Partitions per Sample | ≥17,000 |
| Automation Level | Fully automated end-to-end workflow |
| Chip Format | 16-well disposable cartridge (scalable to 192 samples per run) |
| Run Time for 192 Samples | 8 hours |
| Run Time for 96 Samples | 5 hours |
| Thermal Cycling | Independent programmable thermal cycling per well |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 384 Well |
| Instrument Type | Gradient PCR System |
| Sample Capacity | 384-well plate |
| Max Heating Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Inter-well Temperature Uniformity | ±0.4°C within 10 s at 90°C |
| Gradient Range | 1–24°C across 12 columns |
| Gradient Accuracy (last column) | ±0.2°C |
| Operating Temperature Range | 0–100°C |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 96 Deep Well |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Ramp Rate | 2.5°C/s |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Uniformity | ±0.4°C within 10 s at 90°C |
| Gradient Range | 30–100°C, Span 1–24°C |
| Gradient Accuracy (Last Column) | ±0.2°C |
| Gradient Uniformity (Within Column) | ±0.4°C within 10 s |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| PCR Licensing | Yes |
| Onboard Memory | >1,000 protocols |
| USB Ports | 4 × Type-A, 1 × Type-B |
| Display | LCD |
| Heating Technology | Instant-On Peltier |
| Thermal Block Design | Patented honeycomb architecture |
| Programmable Interface | Text-based and semi-graphical editing |
| Heat Lid | Adjustable pressure, auto-lift compatible |
| Safety | Password-protected protocol folders |
| PC Connectivity | Windows XP or later via C1000 Touch controller (up to 3 S1000 units per C1000) |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ 96-Well |
| Sample Capacity | 96 × 0.2 mL tubes or 1 × 96-well plate |
| Max Heating/Cooling Rate | 5°C/sec |
| Temperature Accuracy | ±0.2°C at 90°C |
| Well-to-Well Temperature Uniformity | ±0.4°C within 10 sec at 90°C |
| Gradient Range | 30–100°C, Span 1–24°C |
| Gradient Accuracy (Last Column) | ±0.2°C |
| Column Uniformity | ±0.4°C within 10 sec per column at target temperature |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | S1000™ Dual 48 Well |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Throughput | 2 × 48 wells (0.2 mL tubes or plates) |
| Max Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.2 °C at 90 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C within 10 s at 90 °C |
| Gradient Range | 30–100 °C, Span 1–24 °C |
| Temperature Range | 0–100 °C |
| Input Power | 400 W max |
| Dimensions (W×D×H) | 33 × 45.7 × 20.3 cm |
| Weight | 10.4 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | S3e |
| Product Type | Flow Cytometric Cell Sorter |
| Lasers | 3 lasers (405 nm, 488 nm, 640 nm) |
| Fluorescence Detection Channels | 6 parameters (4 fluorescence + FSC + SSC) |
| Coefficient of Variation (CV) | ≤2.5% for FITC beads |
| Sorting Speed | Up to 100,000 events/sec |
| Sensitivity | ≥125 MESF (Molecules of Equivalent Soluble Fluorochrome) for FITC |
| Sample Temperature Control | 4–35 °C adjustable, ±0.5 °C stability |
| Nozzle Sizes | 70 µm, 85 µm, 100 µm |
| Auto-Calibration | Fully automated hydrodynamic and optical alignment via AutoGimbal™ system |
| Biosafety Compatibility | Certified for operation inside Class I biosafety cabinets |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | T100™ |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL plates or tubes) |
| Max Heating/Cooling Rate | 4 °C/s |
| Temperature Accuracy | ±0.2 °C (at 90 °C) |
| Well-to-Well Uniformity | ±0.4 °C (at 90 °C) |
| Gradient Range | 30–100 °C |
| Gradient Span | 1–25 °C |
| Operating Temperature Range | 4–100 °C |
| Onboard Memory | 500 protocols |
| Display | 5.7" high-resolution color touchscreen |
| Interface | 1 × USB port |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | TC20 |
| Measurement Time | 30 s |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Throughput | 2 samples per run |
| Detectable Cell Diameter | 6–50 µm |
| Data Storage | Internal memory for 100 assays |
| Dimensions (W × D × H) | 19 × 15 × 25.4 cm |
| Weight | 2.2 kg |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | Trans-Blot Turbo |
| Automation Level | Fully Automated Western Blot Transfer System |
| Throughput | 4 mini gels or 2 midi gels per run |
| Dual Cassette Design | Yes |
| Transfer Time | ≤3 min (2 TGX Mini Gels), ≤7 min (4 standard mini gels or 2 midi gels) |
| Power Supply | Integrated constant voltage/current/power regulator |
| User Interface | Backlit LCD touchscreen with programmable protocol storage (25 protocols) |
| Electrode Architecture | 6-spring-loaded parallel plate electrodes |
| Pre-formulated Kits | Compatible with Turbo Transfer Packs (buffer-free, membrane-ready) |
| Compatibility | Works with standard PVDF/nitrocellulose membranes, conventional electrophoresis buffers (e.g., Tris-Glycine, CAPS), and legacy gel formats |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ZE5 |
| Product Type | Flow Cytometer |
| Application | Research |
| Lasers | 5 lasers |
| Detection Parameters | 30 parameters |
| Coefficient of Variation (CV) | ≤3% |
| Sample Flow Rate | 3.5 µL/min |
| Fluorescence Sensitivity | ≤10 MESF (Molecules of Equivalent Soluble Fluorochrome) for FITC |
| Event Acquisition Rate | Up to 100,000 events/sec |
| Maximum Data Storage per Acquisition | 100 million events |
| Throughput | 96-well plate in ≤12 minutes |
| Fluidic Velocity | 8 m/sec |
| Software | Everest Flow Cytometry Software |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ZOE |
| Product Category | Integrated Fluorescent Cell Imaging System |
| Excitation/Emission Filters (Blue Channel) | 355/40 nm / 433/36 nm |
| Excitation/Emission Filters (Green Channel) | 480/17 nm / 517/23 nm |
| Excitation/Emission Filters (Red Channel) | 556/20 nm / 615/61 nm |
| Imaging Sensor | 5 MP, 12-bit CMOS monochrome camera |
| Display | 10.1-inch high-resolution LCD touchscreen (1280 × 768) |
| Objective | 20× achromatic, wide-field mounting (0.70 mm² FOV, ~180% larger than standard 20×) |
| Stage | Motorized XY stage with ±6 mm travel, touch-controlled navigation |
| Illumination | LED-based brightfield (adjustable green LED ring with quadrant masking for oblique illumination) and fluorescence excitation (no warm-up, >10,000 h lifetime) |
| Image Storage | 16 GB internal memory (~2,500 JPEG images) |
| Output Formats | JPEG, TIFF, RAW |
| Software Features | Real-time gain, exposure time, LED intensity, and contrast adjustment |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX96 Deep Well Dx |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 2.5 °C/sec |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C |
| Excitation Channels | 5 + 1 (including reference channel) |
| Detection Method | Scanning-based fluorescence acquisition |
| Max Reaction Volume | 125 µL |
| LED Light Source Lifetime | >50,000 hours |
| Compliance | MIQE-guided software, FDA 21 CFR Part 11–ready audit trail, ISO 13485-aligned IVD design |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | ddSEQ |
| Regulatory Classification | Import (CE-IVD compliant for research use only) |
| Intended Use | Automated microfluidic droplet generation for single-cell RNA sequencing library preparation |
| Brand | BIO-RAD |
|---|---|
| Origin | USA |
| Model | NGC NFC |
| Max Flow Rate | 200 mL/min |
| Collection Vessel Compatibility | 96-well plates, microcentrifuge tubes, conical tubes, glass vials, and custom containers |
| Optional Features | Peltier-based cooling (4–25 °C), automated calibration routine |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows, supports audit trail generation per FDA 21 CFR Part 11 requirements (when used with compliant NGC Chromatography Software) |
| Vendor Type | Authorized Distributor |