Bruker
Filter
Showing 1–30 of 168 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | JuiceScreener |
| Instrument Type | NMR-Based Beverage Authenticity Analyzer |
| Application | Laboratory |
| Measurement Time | ≤4 min |
| Compliance | ASTM D8271-21, ISO 21569:2022 (NMR-based food authenticity), GLP-compliant workflow via SampleTrack™ |
| Software Platform | TopSpin 4.2 + JuiceScreener Module v3.1 |
| Database | >16,000 reference NMR spectra from authentic fruit juices across 50+ global production regions |
| Quantified Analytes | ≥30 compounds (glucose, fructose, sucrose, citric acid, malic acid, isocitric acid, quinic acid, ethanol, fumaric acid, lactic acid, HMF, galacturonic acid, chloride, etc.) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SuperFlux™ |
| Instrument Type | Online Raman Spectrometer |
| Laser Wavelength | 785 nm |
| Optical Architecture | HTVS™ (High-Throughput Virtual Slit) Technology |
| Safety Features | Integrated laser fiber break detection and hardware interlock |
| Compliance | FDA 21 CFR Part 11 ready |
| Enclosure Rating | Suitable for hazardous (explosion-proof) areas |
| Form Factor | Standalone, compact benchtop unit |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Ultra-High-Field NMR Spectrometer |
| Operating Frequencies | 1.1 GHz (⁴⁷/⁴⁹Ti, ¹H), 1.2 GHz (¹H) |
| Sample Compatibility | Solid–Liquid Dual-Mode |
| Acquisition Method | Pulsed Fourier Transform NMR |
| Magnet Technology | Actively Shielded Superconducting Magnet |
| Probe Options | 3 mm TCI Cryoprobe, 5 mm Triple-Axis Gradient Cryoprobe, 111 kHz MAS Solid-State NMR Probe |
| Detection Modes | Direct ¹³C and ¹⁵N Detection, Parallel Multi-Receiver Acquisition |
| Application Focus | Structural Biology, Intrinsically Disordered Proteins (IDPs), Membrane Proteins, Large Macromolecular Complexes |
| Brand | Bruker |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 450 GC |
| Product Category | Chromatography |
| Operational Age | 3–4 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A2B |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Type | Solid |
| Sensitivity | Signal-to-Noise Ratio (SNR) |
| Resolution | Spectral Linewidth |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | A300/A200 |
| Instrument Type | Continuous-Wave (CW) EPR |
| Design Architecture | A300 – Modular Benchtop System |
| Regulatory Compliance | Designed for GLP/GMP-aligned laboratories |
| Software Framework | Bruker Xenon™ EPR Software Suite |
| Hardware Interface | Digital Signal Processing (DSP) Architecture with Real-Time Data Acquisition |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Albira Si |
| Price Range | USD 1,100,000 – 1,380,000 (based on FOB US pricing and typical import duty/tax structure) |
| Instrument Type | Trimodal Molecular Imaging System |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ALPHA II |
| Instrument Type | Benchtop Laboratory FT-IR Spectrometer |
| Spectral Range | 7500–375 cm⁻¹ |
| Spectral Resolution | 0.8 cm⁻¹ |
| Scan Speed | 3 spectra/sec |
| Signal-to-Noise Ratio | 50,000:1 (at 4 cm⁻¹, 1 min measurement) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ascend Evo 1.0 GHz NMR |
| Price Range | USD $10–20 million |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid-State & Solution-State |
| Operating Frequency | 1.0 GHz |
| Acquisition Mode | Pulsed Fourier Transform (PFT) & Continuous Wave (CW) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | autoflex maX |
| Instrument Type | TOF-TOF |
| Application Scope | Universal |
| Laser Repetition Rate | up to 2 kHz |
| Mass Resolution | up to 26,000 (m/z 1,000–5,000) |
| Mass Accuracy | sub-ppm (calibrated) |
| Detection Sensitivity | low amol (for peptides) |
| Ion Source | Perpetual™ laser-cleanable MALDI source |
| Detector | FlashDetector™ with 10-bit digitizer |
| Software Suite | Compass (flexControl, flexAnalysis, BioTools, GlycoWorkbench, Polymerix) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AVANCE IVDr |
| Pricing | Available Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AVANCE NEO NMR Spectrometer with Ascend Evo Magnet |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid-State and Solution-State |
| Operating Frequency | 400 MHz |
| Acquisition Method | Pulsed Fourier Transform (PFT-NMR) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | High-Field NMR Spectrometer |
| Model | AVANCE NEO 500M |
| Sample Compatibility | Liquid and Solid-State (Dual-Mode) |
| Sensitivity | High Signal-to-Noise Ratio (SNR) |
| Resolution | High Spectral Resolution (Narrow Linewidth) |
| Magnet System | ASCEND™ 500 MHz Superconducting Magnet |
| Console Architecture | Integrated Embedded Acquisition Server (TopSpin 4+) |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–compatible software modules available |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AVANCE NEO 600M NMR Spectrometer (Ascend Evo Magnet) |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid and Liquid Samples |
| Operating Frequency | 600 MHz |
| Data Acquisition Method | Pulsed Fourier Transform |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | AVANCE NEO |
| Instrument Type | High-Field NMR Spectrometer |
| Sample Compatibility | Solid-State & Solution-State (Dual-Mode) |
| Operating Frequency Range | 300–800 MHz (scalable to ≥1.25 GHz) |
| Data Acquisition Method | Pulse Fourier Transform (PFT) |
| Architecture | Integrated Transceiver-Based Digital RF Platform |
| Software Platform | TopSpin 4.x or later with Embedded Acquisition Server |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Online Process Spectrometer |
| Model | BEAM |
| Design | Single-Channel FT-NIR |
| Sample Interface | In-line / At-line (pipeline, hopper, conveyor-mountable) |
| Optical Principle | Interferometric Fourier Transform Spectroscopy |
| Spectral Range | Typically 10,000–4,000 cm⁻¹ (1,000–2,500 nm) |
| Resolution | ≤4 cm⁻¹ (user-selectable) |
| Detector | Thermoelectrically Cooled InGaAs |
| Measurement Mode | Real-time, Continuous, Non-destructive |
| Compliance | Designed for GMP/GLP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioSpec |
| Instrument Type | Nuclear Magnetic Resonance (NMR) Imaging System |
| Field Strength Options | 4.7 T, 7.0 T, 9.4 T, 11.7 T, and 15.2 T configurations available |
| Cryogenic Probe Technology | MRI CryoProbe® |
| Magnet Type | Ultra-Shielded Resistive (USR) or Superconducting Magnets |
| Regulatory Compliance | CE-marked, ISO 13485-certified manufacturing processes, compliant with IEC 62304 for medical device software lifecycle management |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Maxwell |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Energy Resolution | 1000 (arbitrary units, typical for spectral stability metric) |
| Spatial Resolution | 0.05 mm (isotropic, in vivo) |
| Scan Time per Sequence | <1 min (typical for rapid anatomical protocols) |
| Simultaneous Sample Capacity | 2 animals |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | BioSpec® 3T |
| Field Strength | 3 Tesla |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spectroscopy (MRS) System |
| Bore Diameter | 180 mm |
| RF Coil Options | >30 dedicated coils for mouse/rat head, brain, heart, body, multinuclear, and functional applications |
| Gradient Strength | Up to 900 mT/m |
| Gradient Linearity | ±3.5% within 50 mm DSV |
| Shim System | 6 high-order shim coils + high-power shim power supplies (up to 3750 Hz/cm² in XZ/YZ) |
| Magnetic Field Homogeneity | ±0.1 ppm within 50 mm DSV |
| Magnet Hold Time | >4 hours after power loss or coolant interruption |
| Software Platform | ParaVision® with >1000 optimized pulse sequences including IntraGate™, UTE, ZTE, and non-ECG-triggered cardiac imaging |
| Multi-Modal Compatibility | PET, optical imaging, CT |
| Regulatory Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | BRAVO |
| Instrument Type | Handheld Raman Spectrometer |
| Spectral Range | 300–3200 cm⁻¹ |
| Spectral Resolution | 10–12 cm⁻¹ |
| Spatial Resolution | 1–2 mm spot diameter |
| Minimum Wavenumber | 300 cm⁻¹ |
| Spectral Reproducibility | ±100% (relative intensity stability across repeated acquisitions under identical conditions) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | High-Field NMR Spectrometer Software Module |
| Sample Compatibility | Solid and Liquid Samples (Unified Workflow) |
| Sensitivity | Signal-to-Noise Ratio (SNR)-Driven Analysis Validation |
| Resolution | Linewidth-Based Spectral Fidelity Assessment |
| Deployment | Native Integration with Bruker TopSpin™ and IconNMR™ Platforms |
| Regulatory Alignment | Supports GLP/GMP Documentation Requirements, FDA 21 CFR Part 11 Compliant Audit Trail (Optional Configuration) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | compact |
| Instrument Type | Quadrupole-Time-of-Flight (QTOF) |
| Application Scope | Universal LC-MS/MS Platform |
| Key Specifications | 50 GBit/sec acquisition rate |
| Resolution | Ultra-High Resolution TOF (UHR-TOF) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | ContourX-200 |
| Product Type | Non-contact Optical Profilometer / Surface Roughness Analyzer |
| Measurement Principle | White Light Interferometry (WLI) |
| Vertical Resolution | Sub-nanometer (typical < 0.1 nm RMS noise) |
| Lateral Resolution | Diffraction-limited, dependent on objective magnification (e.g., 0.49 µm at 50×) |
| Camera | 5 MP high-speed CMOS sensor |
| Stage | Motorized XY stage with 100 mm × 100 mm travel |
| Field of View | Up to 4.8 mm × 3.6 mm (with 2.5× objective), scalable via 5×–100× objectives |
| Compliance | Fully supports ISO 25178-2, ISO 4287, ASME B46.1, and NIST-traceable calibration protocols |
| Brand | Bruker |
|---|---|
| Model | CryoProbe |
| Origin | Imported |
| Cooling Principle | Closed-cycle helium refrigeration (Gifford-McMahon cryocooler) |
| Operating Temperature | ~20 K (probe coil), ~25 K (preamp) |
| Signal-to-Noise (S/N) Gain | Up to 4× vs. room-temperature probes |
| Compatible Systems | Bruker AVANCE III/IV NMR platforms |
| Probe Configurations | Dual-tuned (e.g., ¹H/¹³C), triple-resonance (e.g., ¹H/¹³C/¹⁵N), with ²H lock and Z-gradient capability |
| Compliance | Designed for GLP/GMP-compliant labs |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CryoSAS |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 280–1500 cm⁻¹ |
| Cooling Method | Closed-Cycle Cryocooler (No Liquid Helium Required) |
| Detection Temperature | <15 K |
| Compliance | ASTM/SEMI MF1630 (B, P), ASTM/SEMI MF1391 (C, O) |
| Sensitivity | Boron/Phosphorus down to ppta |
| Vacuum System | Dual-Stage (Mechanical + Turbo Molecular Pump) |
| Sample Capacity | 9-Position Precision Stepper Motor Stage |
| Sample Holder | Gold-Plated OFHC Copper for Thermal Uniformity |
| Software | Dedicated Industrial QC Interface with Touchscreen Control & Automated Reporting |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CTX |
| Application | Portable/Benchtop |
| Industry Type | General-Purpose |
| Elemental Range | Mg to U |
| Quantification Range | ppm to % |
| Energy Resolution | 145 eV |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D6 PHASER |
| Instrument Type | Powder X-ray Diffractometer |
| Generator Power | 600 W or 1200 W |
| 2θ Calibration Accuracy | ±0.01° |
| Detector | LYNXEYE XE-T Energy-Resolving Detector |
| Beam Optimization | Dynamic Beam Optimization (DBO) |
| Cooling | Air-Cooled (No External Water Chiller Required) |
| Footprint | Compact Benchtop Design |
| Measurement Geometries | Bragg–Brentano Reflection, Transmission, Grazing-Incidence XRD (GIXRD), X-ray Reflectivity (XRR), Residual Stress Analysis, Texture Analysis |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D8 ADVANCE |
| Instrument Type | Powder X-ray Diffractometer |
| Power | 0.0001° angular resolution |
| 2θ Range | −110° to +168° |
| X-ray Tube Targets | Cr / Co / Cu (standard-size) |
| Detector Options | LYNXEYE Array Detector, LYNXEYE XE-T Energy-Dispersive Detector |
| Dimensions | 1868 × 1300 × 1135 mm |
| Weight | 770 kg |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D8 DISCOVER |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 0.0001 kW |
| Compliance | Fully Compliant with ISO 17025, ASTM E975, and IEC 61000-6-3 for Electromagnetic Compatibility |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Powder X-ray Diffractometer |
| Model | D8 ENDEAVOR |
| Detector | LYNXEYE XE-T Energy-Resolving Array Detector |
| Sample Handling | 66-position or 72-position automated sample changer (Ø 51.5 mm and Ø 40 mm formats) |
| Automation Modes | Belt-driven or robotic integration |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Regulatory Context | Fully compatible with FDA 21 CFR Part 11–compliant data management workflows |