Bruker
Filter
Showing 121–150 of 168 results
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/ Floor-standing |
| Model | S2 POLAR |
| Compliance | ASTM D7220, ASTM D4294, ASTM D6481, ASTM D7751, ASTM D8252, ISO 13032, ISO 20847, ISO 8754, IP 336, IP 496, IP 532, JIS K2541-4 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Configuration | Benchtop/Polarized EDXRF |
| Element Range | Na (11) to Am (95), optional C (6) to Am (95) |
| Concentration Range | ppm to 100% |
| Energy Resolution | <135 eV (Mn Kα) |
| Repeatability | <0.1% RSD |
| Detector | HighSense™ Ultra-Low-Noise Silicon Drift Detector (SDD) |
| Compliance | ASTM D6481, ASTM D7751, ASTM D7220, ISO 13032, ASTM D4294, ISO 20847, ISO 8754, IP 336/496/532, JIS K2541-4, GB/T 11140 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S2 PUMA Series 2 |
| Configuration Options | Benchtop / Floor-standing |
| Elemental Range | C (Z=6) to Am (Z=95) |
| X-ray Tube Power | 50 W |
| Detector | HighSense™ Silicon Drift Detector (SDD) |
| Sample Chamber Dimensions | 450 × 420 × 100 mm |
| Autochanger Capacity | Up to 20 positions (XY Autochanger) or 12–18 samples (Carousel) |
| Mapping Resolution | Down to 1 mm |
| Spot Size | 1–34 mm (with collimator masks) |
| Software | SPECTRA.ELEMENTS with SMART.QUANT FP |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S2 PUMA Series II |
| Element Range | Na (11) to Am (95) [C (6) to Am (95)] |
| Detection Range | ppm to 100% |
| Energy Resolution | <135 eV |
| Repeatability | <0.1% RSD |
| Detector | HighSense™ Silicon Drift Detector (SDD) |
| Configuration Options | Manual Single-Position, XY Autochanger, Carousel Autosampler |
| Sample Chamber Dimensions | 450 × 420 × 100 mm |
| X-ray Tube | 50 W Rh anode |
| Filter Changer | 10-position automatic |
| Software Suite | SPECTRA.ELEMENTS with Smart-Quant FP, Geo-Quant, Cement-Quant, and regulatory-compliant modules |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S4 TSTAR |
| Technique | Total Reflection X-Ray Fluorescence (TXRF) |
| Detection Limit | Sub-ppb for liquid, solid, and thin-film samples |
| Sample Forms | Liquids, suspensions, dried residues, wafers, microscope slides, quartz carriers, membranes, filters, and nanoparticle layers |
| Compliance Context | Supports ISO 17025-compliant workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S6 JAGUAR |
| Instrument Type | Benchtop |
| Instrument Kind | Scanning |
| X-ray Tube Power | 400 W |
| Analyzable Elements | F to Am (Fluorine to Americium) |
| Detector | High-sensitivity solid-state detector (HighSense XE™) |
| Optical Configuration | Compact WDXRF optical path with up to 4 collimators, up to 4 analyzing crystals, and dual high-sensitivity detectors |
| Software Platform | SPECTRA.ELEMENTS with SMART-QUANT WD fundamental parameters quantification |
| Automation Interface | AXSCOM-compatible |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S8 LION |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 3–4 kW |
| Analyzable Elements | C (6) to U (92) |
| Instrument Configuration | Simultaneous Multi-channel |
| Compliance | DIN EN ISO 9001:2008, CE, TÜV/PTB certified, radiation dose < 1 µSv/h (H*) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S8 TIGER |
| Instrument Type | Floor-standing |
| X-ray Tube Power | 1–4.2 kW |
| Elemental Range | Be (4) to Am (95) |
| Instrument Configuration | Scanning-type WDXRF |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S8 TIGER (3rd Generation) |
| Instrument Type | Floor-standing WDXRF Spectrometer |
| X-ray Tube Power | 3 kW / 4 kW |
| Analyzable Elements | Be to Am |
| Configuration | Simultaneous/Sequential Multi-channel |
| Detector System | HighSense™ XE + SensorBoost™ Signal Processing |
| Operating Voltage Range | 20–60 kV |
| Sample Capacity | 84-position EasyLoad™ Autoloader with AI Vision |
| Vacuum System | Dual-chamber sealed vacuum with high-transmission beryllium window |
| Crystal Options | 8-position analyzing crystal changer |
| Collimator Options | 4-position collimator changer |
| Filter Options | 10-position filter changer |
| Aperture Mask Options | 5-position mask changer |
| Detectors | Flow-proportional counter & scintillation counter |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometry) |
| Model | scimaX™ |
| Resolution | R > 20,000,000 (at m/z 400) |
| Cooling System | Helium-gas-cooled Maxwell™ superconducting magnet (cryogen-free) |
| Ion Sources | Dual ESI/MALDI with automated switching |
| Fragmentation Modes | ECD, EID, ETD, CID, EDD, SORI-CID, MALDI-ISD, NETD |
| Acquisition Mode | CASI (Collision-Activated Selective Ion accumulation) |
| Application Scope | Universal — petroleumomics, phenomics, metabolomics, native proteomics, label-free MSI, fragment-based drug discovery |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SENTERRA II |
| Instrument Type | Confocal Raman Microspectrometer |
| Spectral Range | 50–4400 cm⁻¹ |
| Spectral Resolution | 1.5 cm⁻¹/pixel |
| Spatial Resolution | Lateral 1 µm, Axial 2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Reproducibility | 0.06 cm⁻¹ |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIGIS II |
| Pricing | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 1178 |
| Instrument Type | Tomographic Imaging |
| X-ray Source | Sealed Metal-Ceramic Tube (20–65 kV, 40 W) |
| Detector | Digital X-ray Camera (1280 × 1024 pixels, 12-bit) |
| Scan Volume | Ø82 mm × 82 mm (single scan), up to 200 mm full-length |
| Voxel Size (isotropic) | 80 µm (1024³) or 160 µm (512³) |
| Minimum Scan Time | <45 s (160 µm) |
| Full-body mouse scan | 3 min 20 s (80 µm) |
| Reconstruction Time | 45 s (160 µm) |
| Animal Handling | Carbon-fiber mouse/rat bed on interchangeable mounting platform |
| Physiological Monitoring | Real-time respiration & ECG gating, motion detection |
| Radiation Safety | Surface dose rate <1 µSv/h during operation |
| Software Suite | NRecon, DataViewer, CTAn, CTVol, MorphoGraphX |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SkyScan 1272 |
| Detector | 16 MP sCMOS |
| Voxel Size | down to 0.4 µm |
| X-ray Source | 20–100 kV adjustable |
| Field of View | up to Ø25 mm |
| Auto-Sampler | optional 16-position |
| In Situ Stages | compression (4400 N), tension (440 N), heating (+80 °C), cooling (−30 °C below ambient) |
| Software | NRecon, CTAnalyser, DataViewer, CTVox (GPU-accelerated 3D.SUITE) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SKYSCAN 1273 |
| X-ray Source Energy | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel, 3072 × 1944 pixels |
| Spatial Resolution | < 5 µm (3D) |
| Voxel Size | < 3 µm |
| Maximum Sample Dimensions | Ø300 mm × H500 mm, up to 20 kg |
| Field of View | Ø250 mm × H250 mm |
| Image Matrix | up to 4800 × 4800 pixels |
| Detector Output Speed | High-frame-rate acquisition enabled |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SkyScan 1273 |
| X-ray Source | 40–130 kV, up to 39 W |
| Detector | 6 MP CMOS flat-panel (3072 × 1944 pixels) |
| Spatial Resolution | < 5 µm |
| Voxel Size | < 3 µm |
| Max Sample Dimensions | Ø250 mm × H250 mm |
| Max Sample Weight | 20 kg |
| Reconstructed Volume | up to 4800 × 4800 pixels |
| External Dimensions | 1250 × 815 × 820 mm (W × D × H) |
| Radiation Leakage | < 1 µSv/h at any point on external surface |
| Power Supply | 100–240 V, 50–60 Hz, 3 A |
| Weight | 400 kg (net) |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan 1275 |
| X-ray Source | 20–100 kV, 10 W, < 5 µm focal spot size at 4 W |
| Detector | 3 MP CMOS flat-panel detector (1944 × 1536 effective pixels) |
| Spatial Resolution | < 4 µm (nominal, at maximum magnification) |
| Density Resolution | < 4 µm (nominal, inferred from spatial resolution and contrast transfer performance) |
| Sample Capacity | Max height 120 mm, max diameter 96 mm |
| Dimensional Measurement Accuracy | Consistent with < 4 µm spatial resolution under calibrated conditions |
| Density Measurement Accuracy | Supported by high dynamic range (16-bit) detector and beam-hardening correction algorithms |
| Power Requirement | Standard 230 V AC, 50/60 Hz, single-phase outlet |
| Radiation Safety | Compliant with IEC 61000-6-3, IEC 61000-6-4, and national regulatory requirements for Class II B radiation devices |
| Brand | Bruker |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | SKYSCAN 1275 |
| Service Pricing | USD 5,000–10,000 per scan session |
| Years of Service Experience | 3 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 1276 |
| Imaging Modality | X-ray micro-computed tomography (micro-CT) |
| Spatial Resolution (nominal) | ≤2.8 µm |
| Scan Modes | Step-and-shoot, continuous gantry rotation with slip-ring interface |
| Scan Time per Reconstruction | as low as 3.9 s |
| Reconstructed Slice Count per Scan | >1600 slices |
| Max Image Matrix Size | 8000 × 8000 pixels |
| X-ray Source Voltage Range | 20–100 kV adjustable |
| Automatic Filter Changer | 6-position |
| Dose Reduction Technology | Beam-shaping collimator (patented by Bruker microCT) |
| Physiological Monitoring Integration | Respiratory gating, ECG synchronization, temperature stabilization, motion detection |
| Animal Handling | Interchangeable mouse/rat beds with integrated anesthesia mask and sensor interface |
| Real-time Dose Monitoring | On-screen dosimetry derived from projection image analysis |
| Reconstruction Acceleration | GPU-accelerated algorithms + InstaRecon® layered reconstruction (≥10× faster than conventional FBP) |
| Software Compliance | GLP-compliant software suite with audit trail, user access control, and electronic signature support |
| Data Export & Remote Viewing | Direct export to iOS/Android devices via dedicated viewer app |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SkyScan 2211 |
| X-ray Source | 20–190 kV, 4/10/25 W, sub-micron focal spot size, 5-position filter wheel |
| X-ray Target | Tungsten (standard) |
| Detector | 3 MP CMOS flat panel (1920 × 1536 px) or 11 MP cooled CCD (4032 × 2670 px) |
| Reconstruction Volume (CMOS) | up to 3776 × 3776 × 1160 px (dual offset mode) |
| Reconstruction Volume (CCD) | up to 8000 × 8000 × 2272 px (dual offset mode) |
| Spatial Resolution | down to 100 nm (detector-limited, geometry-dependent) |
| Sample Capacity | Ø204 mm × L200 mm, max. 25 kg |
| Sample Positioning | direct-drive air-bearing rotation stage with integrated piezo-driven micro-positioning (5.5 mm travel) |
| Reconstruct Time | 1 min 12 sec (600 projections, 2K × 2K × 1K) |
| Radiation Safety | <0.5 µSv/h at 10 cm from surface (measured at 190 keV, 4 W on target) |
| Power Supply | 100–130 V or 200–240 V AC, 50–60 Hz |
| Cooling & Air Supply | integrated closed-loop water chiller and oil-free air compressor with particle filters and desiccant dryer |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Voxel Resolution | <0.35 µm (16 MP detector) / <0.45 µm (11 MP detector) |
| Max Reconstructed Volume | 14456 × 14456 × 2630 px (16 MP) or 11840 × 11840 × 2150 px (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm (standard) |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Spatial & Density Resolution | <0.35 µm (16 MP) / <0.45 µm (11 MP), isotropic voxel capability |
| Reconstruction Engine | InstaRecon® real-time GPU-accelerated 3D reconstruction |
| Scan Modes | Cone-beam, helical, phase-contrast enabled, dynamic time-lapse |
| Compliance | Fully compatible with ASTM E1441, ISO 15732, and USP <1059> for non-destructive volumetric analysis |
| Brand | Bruker |
|---|---|
| Origin | Belgium |
| Model | SKYSCAN 2214 |
| X-ray Source | 20–100 kV, 10 W, <5 µm focal spot size at 4 W |
| Maximum Reconstruction Volume | 14456 × 14456 × 2630 px (16 MP detector) or 11840 × 11840 × 2150 px (11 MP detector) |
| Spatial Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Sample Capacity | Ø ≤ 75 mm, H ≤ 70 mm |
| Detector | 16 MP (4904 × 3280 px) or 11 MP (4032 × 2688 px), 14-bit cooled CCD coupled 1:1 to scintillator via fiber optic taper |
| Density Resolution | <0.35 µm (16 MP), <0.45 µm (11 MP) |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SkyScan1278 |
| Instrument Type | Tomographic Imaging System |
| Energy Resolution | 17% |
| Spatial Resolution | 50 µm |
| Scan Time | 7.2 s per full-body mouse scan |
| Field of View Diameter | 80 mm |
| Scan Length | 200 mm |
| Sample Capacity | 1 animal per scan |
| X-ray Source | Adjustable 20–65 kV microfocus tube with patented beam shaping optics |
| Detector | High-sensitivity CMOS flat-panel detector |
| Dose Level | <6 mGy for whole-body murine scan |
| Physiological Gating | Integrated respiratory, ECG, temperature, and motion monitoring |
| Data Output Formats | DICOM, TIFF, JPG, BMP, PNG, AVI |
| Software Compliance | GLP-compliant acquisition and reconstruction suite |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | solariX |
| Instrument Type | FTMS (Fourier Transform Mass Spectrometer) |
| Magnetic Field Strength Options | 7T, 12T, 15T |
| Ionization Modes | ESI and MALDI (dual-source configurable) |
| Detection Technology | ParaCell detector with AMP (Absorption Mode Processing) |
| Software Platform | Bruker Compass suite including SmartFormula |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | SPR #64 |
| Instrument Type | Surface Plasmon Resonance (SPR) |
| Channel Configuration | 8-Channel Orthogonal Flow Cell with 64 Sensor Spots |
| Fluidic Flexibility | Up to 8 Simultaneous Buffer Streams |
| Automation Interface | RESTful API & Robotic Integration Ready |
| Sample Format Support | 96-well & 384-well Microplates, Reagent Reservoirs, External Cooling-Compatible Stage |
| Cleaning Mechanism | Integrated Dual-Prism Cartridge with Auto-Clean Protocol |
| Data Output Format | Open HDF5, CSV, and JSON |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TANGO |
| Instrument Type | Laboratory |
| Principle | Fourier Transform (FT) |
| Wavelength Range | 11,500–4,000 cm⁻¹ |
| Scan Speed | 8 scans/sec |
| Data Sampling Interval | 4 cm⁻¹ |
| Measurement Modes | Diffuse Reflectance / Transmission |
| Chemometrics Software | OPUS |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Model | timsMetabo™ |
| Application Scope | Universal (Metabolomics, Lipidomics, Untargeted Small-Molecule Analysis) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS)–based Mass Spectrometer |
| Model | timsOmni |
| Application Scope | Universal for native and denatured proteoforms, intact proteins, oligonucleotides, PTMs, small molecules, and multi-specific biologics |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | timsTOF fleX™ |
| Instrument Type | Trapped Ion Mobility Spectrometry (TIMS) Mass Spectrometer |
| Application Scope | Universal Platform for Spatial Omics and Molecular Imaging |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Ion Mobility Mass Spectrometer |
| Model | timsTOF fleX with MALDI-2 |
| Application Scope | Universal (Biological Tissue Imaging, Lipidomics, Metabolomics, Drug Distribution Studies) |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | SCiLS Lab, DataAnalysis, and TIMS Control integrated in Compass 6.0 suite |
| Ionization Modes | MALDI and MALDI-2 (laser post-ionization), ESI (via LC coupling) |