Dynamax
Filter
Showing all 15 results
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Agrisensors |
| Pricing | Available Upon Request |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | DEX |
| Measurement Principle | Resistive Strain-Bridge Displacement Sensing with Integrated Temperature Compensation |
| Operating Temperature Range | –10 to 50 °C |
| Accuracy | ±0.050 mm (for ΔT > 20 °C) |
| Temperature Stability | 0.0025 mm/°C |
| Output Signal | Analog ±5 mV or ±2.5 mV (model-dependent) |
| Sensitivity | 0.05–0.5 mV/mm |
| Linearity Error | ±0.004 to ±0.01 mV/mm |
| Electrical Noise | ±0.01 mV |
| Compatible Data Loggers | Supports up to 8 or 32 sensors per system |
| IP-Rated Enclosure | Sealed Electronics for Outdoor & Field Deployment |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | Dynamet |
| Sensor Core | Gill MaxiMet™ 500 (Dynamet 2 & 5) / MaxiMet™ 600 (Dynamet 6) |
| Wind Measurement | Ultrasonic |
| Data Capacity | 100,000 records |
| ETP Calculation | Penman–Van Bavel (PENV) algorithm |
| Communication | Optional 2G/3G DTU or VPN-based cellular transmission |
| Compliance | ASTM D5098, ISO 17025-aligned sensor validation protocols, WMO Guide to Instruments and Methods of Observation (CIMO) reference-class deployment |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | EXO-Skin™ |
| Sensor Type | Heat-Balance-Based Wrap-Around Sap Flow Sensor |
| Diameter Range | 9.5–25 mm |
| Height | 70–120 mm |
| Input Voltage | 4.5 V DC |
| Typical Power Consumption | 0.13–0.48 W |
| Thermocouple Pairs | 2 per unit |
| Enclosure | PTFE-Composite Vapor-Permeable Waterproof Membrane |
| Mounting | Velstretch® Elastic Nylon Band (Breathable, Hydrophobic, Growth-Accommodating) |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | FLGS-TDP |
| Data Logger Memory | 4 MB standard (expandable to 16 GB microSD) |
| Storage Capacity | 400 days at 1-hour interval |
| Input Channels | 32 differential analog inputs |
| Max Probe Support | 128 × TDP10/30/50, 64 × TDP80, or 40 × TDP100 |
| Temperature Accuracy | ±0.03 °C |
| Temperature Resolution | 0.0083 °C |
| AVRD Voltage Regulation | 4 channels (1.5–10 V, 5 A each) |
| System Dimensions | 45 × 35 × 16 cm |
| Weight | 11.5 kg |
| Power Supply | Dual-voltage AC adapter (110–220 V, 50–60 Hz, 4.5 A) |
| Standard Cable Length | 3 m (extendable to 22.8 m) |
| Compliance | Designed for long-term field deployment under GLP-aligned environmental monitoring protocols |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Flow32-1K |
| Pricing | Upon Request |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | Flow32-1K |
| Power Supply | 12 V rechargeable lead-acid battery (7 Ah) |
| Data Storage | 4 MB internal (expandable to 16 GB via microSD) |
| Channel Capacity | Up to 32 differential analog input channels |
| Sensor Compatibility | 14 sizes of Dynagage wrap-around stem flow sensors (stem diameter range: 2.1–165 mm) |
| Voltage Regulation | Dual AVRD modules, 1.5–10 V adjustable, 5 A per channel |
| Input Resolution | 0.05–0.88 µV |
| Input Range | ±200–5000 mV |
| Communication | Micro-B USB, Ethernet |
| Enclosure | Fiberglass weatherproof cabinet (43 × 35 × 16 cm), 11.5 kg |
| Operating Mode | AVRD adaptive power-saving mode with automatic Ksh zero-point recalibration |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | HCFM-XP Gen3 |
| Measurement Diameter Range | 1–36 mm |
| Flow Rate Range | 0.01–350 g/h (5 selectable ranges) |
| Hydraulic Conductance Range | 7.7×10⁻⁸ to 3.5×10⁻⁴ kg·s⁻¹·MPa⁻¹ |
| Pressure Output Resolution | 0.1 kPa |
| Max Operating Pressure | 620 kPa |
| Deaerated Water Reservoir Capacity | 0.7 L |
| Compressed Gas Cylinder Capacity | 170 L (at STP), CGA-580 valve |
| Data Acquisition | 1 reading per 2 s |
| A/D Conversion | 24-bit dual analog/digital |
| Dimensions (L×W×H) | 61×48×23 cm |
| Weight | 15 kg |
| Power & Interface | USB-powered, integrated data logging |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | HPFM-Gen3 |
| Pressure Range | 0–630 kPa |
| Flow Rate Range | 0.7–2500 g/h (6 full-scale ranges) |
| Hydraulic Conductance Range | 7.7×10⁻⁸ to 2.2×10⁻³ kg·s⁻¹·MPa⁻¹ |
| Sampling Interval | 1 reading per 2 s |
| A/D Resolution | 24-bit dual analog-to-digital conversion |
| Dimensions | 33 × 31 × 52 cm |
| Weight | 12 kg (excluding pressure vessel) |
| Deaerated Water Capacity | 8 L |
| Power & Interface | USB-powered, no external power supply required |
| Operating Systems | Windows XP, Vista, Windows 7 |
| Compliance | NIST-traceable calibration, GLP-compliant data acquisition architecture |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | InteliMet Advantage |
| Sensor Compatibility | GMX500/GMX600 Integrated Meteorological Sensors |
| Power Supply | 10 W Solar Panel with Battery Backup |
| Communication Options | Wired USB/RS-485 or Optional 2G/3G DTU/VPN Cellular Module |
| Environmental Rating | IP66 |
| EMC Compliance | BS EN 61326:2013, FCC CFR 47 Part 15.109 |
| Operating Temperature Range | -40 °C to +70 °C |
| Wind Speed Range | 0.1–60 m/s (±3% @ 0–40 m/s |
| Wind Direction Range | 0–359° (±3° @ 0–40 m/s |
| Atmospheric Pressure Range | 300–1100 hPa (±0.5 hPa @ 25 °C) |
| Air Temperature Range | -40–70 °C (±0.3 °C @ 20 °C) |
| Relative Humidity Range | 0–100 %RH (±2 %RH @ 10–90 %RH, 20 °C) |
| Dew Point Accuracy | ±0.3 °C @ 20 °C |
| Rainfall Measurement (InteliMet Advantage 5) | Tipping Bucket (UV-stabilized ABS |
| Rainfall Measurement (InteliMet Advantage 6) | Optical Sensor (0–150 mm/hr |
| Solar Radiation Spectral Range | 380–1120 nm (±5% absolute accuracy) |
| Data Processing | ETP calculation per Lascano & Van Bavel (ASA, 2006) |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SapIP Monitoring Network |
| Node-to-Node Range | 300–500 m |
| Onboard Storage | 30,000 Records per Node |
| Compliance | Designed for Field-Deployable Ecophysiological Research under GLP-Aligned Data Integrity Practices |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SapIP-IRT |
| Field of Application | Non-contact plant canopy surface temperature measurement for irrigation scheduling and physiological stress monitoring |
| Viewing Angle | 20° |
| Measurement Accuracy | ±0.5°C (ambient temperature range 0–50°C) |
| Operating Temperature | 0–50°C |
| Power Supply | Rechargeable battery with optional 2 W solar panel |
| Output Options | Analog (0–5 V or 4–20 mA), SDI-12, or wireless (SapIP mesh protocol) |
| Data Logging | Configurable interval from 10 s to 60 min |
| Network Topology | Self-organizing wireless mesh (SapIP) supporting up to 200 sensor nodes per network |
| Transmission Range | Up to 1.6 km radius (line-of-sight, terrain-dependent) |
| Compliance | CE, FCC Part 15, RoHS |
| Software Integration | Watcher™ desktop application (Windows), cloud-based data dashboard (HTTPS/TLS encrypted) |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SapIP-MICRO |
| Instrument Type | Wireless Mesh-Based Environmental Monitoring System |
| Data Transmission | LoRaWAN / Cellular (SPIP-CELL optional) |
| Network Topology | Self-Healing Mesh |
| Max Nodes per Network | 25 |
| Inter-Node Range | 300–500 m (line-of-sight, SPIP-24K radio) |
| Operating Temperature | −40 to +70 °C |
| Relative Humidity Range | 0–100 % RH |
| Accuracy | ±3 % RH (0–90 % RH, 20 °C), ±5 % RH (90–100 % RH) |
| Air Temperature Range | −40 to +60 °C |
| Accuracy | ±0.6 °C |
| Solar Radiation Range | 0–2000 W/m² |
| Spectral Response | 360–1120 nm |
| Absolute Accuracy | ±5 % |
| Rainfall Resolution | 0.25 mm |
| Accuracy | ±4 % or ±1 tip (0.2–50.0 mm/hr) |
| Wind Speed Range | 0–50 m/s |
| Accuracy | ±0.5 m/s |
| Wind Direction Range | 0–360° |
| Accuracy | ±5° |
| Onboard Memory | 30,000 records |
| Power | 7 Ah rechargeable battery + 10 W solar panel |
| Input Channels | 8 differential analog inputs |
| ETP Calculation | FAO-56 Penman-Monteith supported in firmware |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SGDC |
| Type | Heat Balance-Based Stem Flow Sensor |
| Compliance | Validated per USDA-ARS protocols (Lascano et al., 2016, *Agric. Sci.*) |
| Channel Requirement | 2 differential analog inputs (temperature + heater voltage/current) |
| Stem Diameter Range | 7–25 mm (model-dependent) |
| Enclosure Design | EXO-Skin conformal wrap |
| Heater Architecture | Molded, low-thermal-mass resistive element |
| Environmental Protection | IP67-rated moisture barrier |
| Calibration Traceability | NIST-traceable thermistor and voltage references |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | SapIP |
| Pricing | Upon Request |