FPI (Focus Photonics Inc.)
Filter
Showing all 17 results
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CMS odor 1000 |
| Detection Principle | Gas Chromatography–Ion Mobility Spectrometry (GC-IMS) |
| Instrument Type | Online Analytical System |
| Typical Configuration | Multi-Compound VOC & Odorant Analyzer |
| Regulatory Compliance | GB 14554–201X, DB31/1025–2016, DB12/059–2018 (22 regulated odorants, qualitative & quantitative) |
| Detection Limit | Sub-ppt (parts-per-quadrillion) for key sulfur/nitrogen compounds |
| Resolution | 100 (IMS drift time resolution, FWHM) |
| Accuracy | ≤10% RSD (relative standard deviation) for calibrated odorants |
| Response Time | ≤10 s (IMS-only mode) |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Model | ETMS-200-ZG |
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Pricing | Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Regional Classification | Domestic (PRC) |
| Model | EXPEC 1850-E |
| Detection Principle | Simultaneous Visible-Light Imaging + Uncooled Microbolometer-Based Thermal Imaging |
| Enclosure Rating | Ex d IIC T6 Gb / Ex tb IIIC T80°C Db (IEC 60079-0, -1, -31) |
| Mounting | Integrated 360° Pan-Tilt-Zoom (PTZ) Intrinsically Safe Panoramic Turret |
| Optical Interface | Standardized BNC + RJ45 + RS485 |
| Communication Protocols | Pelco-D, Pelco-P, ONVIF Profile S |
| Environmental Rating | IP66, -40°C to +60°C operational |
| Power Supply | 24 VDC (intrinsically safe circuit design) |
| Alarm Output | Relay contact (NO/NC), configurable thermal threshold triggers |
| Image Overlay | Real-time temperature heatmap superimposed on visible image |
| Data Output | H.265/H.264 dual-stream encoding, radiometric JPEG sequence export |
| Compliance | GB 3836.1–2021, GB 3836.4–2021, IEC 60079-11, UL 60079-11 Ed.7, ATEX Directive 2014/34/EU |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AFS-10U |
| Pricing | Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | AQMS-3000 |
| Pricing | Available upon request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Aerosol Black Carbon Analyzer |
| Measurement Principle | Optical Attenuation (Filter-Based Transmission) |
| Wavelength Channels | 7-channel (370, 450, 520, 590, 660, 880, 950 nm) |
| Primary Output | Black Carbon Mass Concentration (µg/m³) and Wavelength-Dependent Absorption Coefficient (Mm⁻¹) |
| Compliance | QX/T 68–2007 (China Meteorological Administration Standard) |
| Flow Control | Integrated Precision Mass Flow Controller |
| Detection System | Dual Photodetector Correction + Charge-Integrating ADC Architecture |
| Data Output | Real-time, Continuous, On-line |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Flue Gas Heavy Metal Analyzer |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Elemental Coverage | Pb, Hg, Cr, Cd, As, and up to 26 heavy metals (expandable via spectral library calibration) |
| Detection Limit | < 0.1 µg/m³ (for key elements under ISO 14927-compliant sampling conditions) |
| Filter Replacement Interval | ≥ 30 days (typical, dependent on particulate loading) |
| Operating Ambient Temperature | 0–40 °C |
| Operating Ambient Humidity | 10–90 % RH (non-condensing) |
| Operating Ambient Pressure | 86–106 kPa |
| Compliance | Meets China’s HJ 1131–2020 and EU EN 14385 technical requirements for continuous heavy metal emission monitoring |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ETMS-100 |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | LAMPAS-3.0 |
| Pricing | Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Online Analyzer |
| Optical Configuration | Dual-Station Open-Path FTIR |
| Spectral Resolution | 1 cm⁻¹ |
| Detector Operating Temperature | −196 °C (Liquid Nitrogen Cooled MCT) |
| Detection Limit | Sub-ppb for Selected Analytes |
| Spectral Library | >300 Reference Spectra (Validated Against Bruker and Anhui Institute of Optics and Fine Mechanics Libraries) |
| Gas Coverage | ≥20 Target Species Including VOCs, CO, CO₂, NH₃, SO₂, NO, HCl, HF, CH₄ (Customizable) |
| Sample Handling | Direct Ambient Air Measurement — No Pre-concentration, No Chemical Derivatization, No Sampling Line Required |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PANs-1000 |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Model | PFS-100 |
| Type | Online Multicomponent Photolysis Rate Analyzer |
| Measurement Principle | Actinic Flux-Based Spectral Radiometry |
| Optical Path | Quartz Collector + UV-VIS Optical Fiber Coupling |
| Detector | Thermoelectrically Cooled CCD Array |
| Spectral Range | 280–450 nm (configurable) |
| Spectral Resolution | ≤0.5 nm (FWHM) |
| Calibration Traceability | NIST-traceable actinic flux calibration |
| Data Output | Real-time J-value time series (s⁻¹) for O¹D, NO₂, OH, HONO, HCHO, and other photolabile species |
| Compliance | Designed per ISO 17025 laboratory practice guidelines |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TOFMS-100 |
| Detection Principle | Single-Photon Ionization Time-of-Flight Mass Spectrometry (SPI-TOFMS) |
| Instrument Type | Continuous Online Analyzer |
| Configuration | Integrated VOC Monitoring System with GIS-enabled Mobile Deployment Capability |
| Detection Range | 0.1 ppb – 1000 ppm (v/v) |
| Mass Resolution | >800 (FWHM at m/z 92) |
| Accuracy | < ±1% Full Scale (0–500 ppb) |
| Response Time | ≤1 s (T90) |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WPR-Series |
| Laser Source | Not applicable (UHF/VHF passive radar principle) |
| Detector | Coherent pulsed Doppler receiver with 16-bit A/D sampling |
| Operating Frequency Band | UHF (915 MHz) or VHF (50 MHz typical, configurable) |
| Maximum Detection Altitude | Up to 12 km (dependent on frequency band and atmospheric conditions) |
| Pulse Repetition Frequency (PRF) | Configurable, typically 100–2,000 Hz |
| Measurement Parameters | Horizontal wind vector (u/v), vertical velocity (w), virtual temperature gradient, refractivity structure parameter (Cn²) |
| Compliance | Designed per MIL-STD-810G environmental ruggedization |
| Key | Brand: FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | FPI-PSA |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ProGC-3800 |
| Pricing | Available Upon Request |
| Explosion Protection Rating | Ex d IIC T6 Gb |
| Ingress Protection Rating | IP65 |
| Column Oven Thermal Stability | ±0.01 °C |
| Detector Compatibility | TCD, FID, FPD, PDD |
| Primary Application Domain | Natural Gas Process Monitoring |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Automation Level | Full End-to-End Sample-to-Result Automation |
| Sample Forms Supported | Solid and Liquid Matrices |
| Acid Compatibility | HNO₃, HCl, HF, HClO₄ |
| Volumetric Accuracy | <0.025 mL (5–50 mL range) |
| Sample Introduction | Integrated Auto-Sampling with In-Line Filtration |
| Safety Features | Auto-Ignition, Auto-Optimization, Auto-Quenching, Acid-Fume Extraction, Corrosion-Resistant Fluidic Pathways |
| Calibration & QC | Auto-Standard Curve Generation, Multi-Point QC Triggering (LOD, Blank, CRM), Adaptive Response Logic (Re-run / Skip / Abort) |
| Data Interface | Real-Time CPS/Concentration/RSD Dashboard, Interactive Calibration Plotting, Outlier Flagging |