Galvanic
Filter
Showing 1–30 of 31 results
| Brand | Galvanic |
|---|---|
| Origin | Canada |
| Model | 903W |
| Instrument Type | Online Gas Analyzer |
| Target Gas | Hydrogen Sulfide (H₂S) |
| Response Time (T₉₀) | < 20 s |
| Measurement Accuracy | ±10 ppb (LOD) |
| Measurement Range | 0–2000 ppm (undiluted) |
| Linearity | ±1% FS |
| Repeatability | ±1% FS (>1 ppm), ±2.5% FS (<1 ppm) |
| Operating Temperature | 10–50 °C |
| Power Input | 90–240 VAC / 10–36 VDC |
| Certifications | CSA C/US, Class I, Div 2, Groups B, C, D, T3 |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseies Series |
| Measurement Principle | Colorimetric Titration with Dual-Wavelength Photometric Endpoint Detection (650 nm / 810 nm) |
| Range Options | 0–20 mg/L or 0–500 mg/L H₂SO₄ |
| Accuracy | ±1% of full scale |
| Linearity | ±1% FS |
| Repeatability | ±1% RSD |
| Analysis Cycle Time | 15 min per sample |
| Sample Flow Rate | 200 mL/min |
| Max Sample Pressure | <5 psi |
| Suspended Solids Limit | <1,000 µm |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm (H) × 406 mm (W) × 241 mm (D) |
| Weight | 45.3 kg |
| Power Supply | 24 VDC or 90–240 VAC |
| Enclosure Rating | NEMA 4X (IP65) |
| Communication | 4–20 mA, Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, Ethernet |
| Digital I/O | 8 programmable dry/wet contacts (24 VDC) |
| Analog Outputs | Up to 8 isolated 4–20 mA loops (self-powered) |
| Sample Interface | 1/4″ compression fitting |
| Environmental Resistance | H₂S- and Cl₂-resistant materials |
| System Architecture | Physically isolated electronic control unit and wet chemistry module |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Accuseries Copper Ion Concentration Analyzer |
| Measurement Principle | Bathocuproine (BCO) Colorimetric Method |
| Range | 0–10 ppm Cu²⁺ |
| Optical Technology | Dual-Wavelength Photometry |
| Probe Type | Fiber-Optic Immersion Probe |
| Display | High-Resolution LCD with Dedicated Function Keypad |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs |
| Automation | Fully Automated 24/7 Operation — Auto-Calibration, Auto-Cleaning, Reagent Auto-Fill |
| System Architecture | Physically Isolated Electronic Control Unit and Sample Analysis Module |
| Maximum Flow Paths | 6 Independent Channels |
| Corrosion Resistance | IP65-rated Enclosure |
| Diagnostic Capability | Real-Time Remote Self-Diagnosis with Alarms for Sample Absence, Low Reagent Level, Flow Failure, and Optical Path Obstruction |
| Compliance | Designed for Continuous Emission Monitoring (CEM) and Process Analytical Technology (PAT) Environments |
| Software Support | Web-based Configuration Interface with Audit Trail Logging (21 CFR Part 11 Ready) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries LPA Online Analyzer |
| Instrument Type | Online Chloride Analyzer |
| Measurement Range | 0–50 ppm |
| Detection Limit | 0.1 ppm |
| Response Time | 8 min |
| Accuracy | ±1% of reading |
| Operating Temperature Range | −20 °C to +60 °C |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS458, USB, GUI PC Direct Connection, Relay Outputs |
| Sample Streams | Up to 6 independent flow paths |
| Analytical Method | Potentiometric Titration |
| Enclosure Rating | IP65 (corrosion-resistant, H₂S/Cl₂ tolerant, moisture-proof) |
| Service Life | Designed for continuous 24/7 operation with automated reagent management |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Accuseries LPA Online Analyzer |
| Instrument Type | Online Multi-Ion Analyzer |
| Measurement Range | 0–500 mg/L |
| Detection Limit | 1 ppm |
| Response Time | 10 min |
| Accuracy | ±1% of reading |
| Operating Temperature Range | −20 °C to +60 °C |
| Measurement Principle | Potentiometric Titration |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection |
| Relay Outputs | Yes |
| Sample Streams | Up to 6 modular flow paths |
| Enclosure Rating | IP65 (corrosion-resistant, H₂S/Cl₂ tolerant, moisture-proof) |
| Automation Level | Fully Automated (auto-calibration, auto-cleaning, reagent replenishment, 24/7 unattended operation) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries LPA Online Analyzer |
| Instrument Type | Online Sodium Ion Analyzer |
| Measurement Range | 0–10,000 ppb |
| Detection Limit | 0 ppb |
| Response Time | 10 min |
| Accuracy | ±1% of reading |
| Operating Temperature | −20 to +60 °C |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection |
| Sample Streams | Up to 6 modular flow paths |
| Compliance | Designed for continuous operation in industrial water monitoring per ASTM D4192, ISO 10523, and USP <643> guidance for sodium in purified water systems |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeries |
| Price | Upon Request |
| Measurement Principle | Redox Colorimetric Titration |
| Wavelengths | 650 nm (test), 810 nm (reference) |
| Range | 0–1,000 ppm (customizable) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% FS |
| Repeatability | ±1% FS |
| Analysis Cycle Time | 10 min |
| Sensitivity | 1% FS |
| Ambient Temperature | 20–60 °C (−4–140 °F) |
| Dimensions | 1016 mm H × 406 mm W × 241 mm D |
| Weight | 45.3 kg |
| Sample Interface | 1/4″ compression fitting |
| Sample Flow Rate | 200 mL/min |
| Max Sample Pressure | <5 psi |
| Max Suspended Solids | <1,000 µm |
| Power Supply | 24 VDC or 90–240 VAC |
| Analog Outputs | up to eight isolated 4–20 mA (self-powered) |
| Digital Inputs | 8 dry/wet contacts (24 VDC) |
| Ethernet | Embedded GUI via Modbus TCP/IP |
| Serial Protocols | Modbus RTU over RS-232/RS-485 |
| Alarm Outputs | User-configurable relay outputs |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Corrosion Resistance | H₂S- and Cl₂-resistant housing |
| Flow Path Architecture | Modular, scalable to 6 independent sample streams |
| Control Architecture | Physically segregated electronics and wet chemistry modules |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries |
| Type | Online Multi-Ion Analyzer |
| Measurement Accuracy | ±1% FS |
| Linearity | ±1% FS |
| Repeatability | ±1% FS |
| Response Time | 8–12 min |
| Operating Temperature Range | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 300 W |
| Analog Outputs | up to eight 4–20 mA |
| Communication Protocols | Modbus RTU (RS-232/RS-485), Modbus TCP/IP |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AccuSeries |
| Pricing | Upon Request |
| Display | High-resolution LCD with auxiliary programmable keypad |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC direct connection, relay outputs |
| Architecture | Modular analytical method design with field-configurable protocols |
| Diagnostics | Remote self-diagnosis with real-time alerts for sample absence, reagent level, system fault, and maintenance status |
| Automation | Fully automated 24/7 operation including auto-calibration, auto-zeroing, reagent dispensing, line flushing, and endpoint detection |
| System Isolation | Physically separated electronic control unit and wet chemistry module |
| Corrosion Resistance | IP66-rated enclosure with H₂S- and Cl₂-resistant materials |
| Electronics Design | Partitioned motherboard architecture—failure in flow control module does not interrupt main processor or DCS/PLC communication |
| Programmability | User-defined assay sequences (reagent addition order, pre-/post-measurement rinse cycles, auto-zero timing) |
| Analytical Method | On-line potentiometric titration using 0.01 N HCl standard solution with pH electrode endpoint detection |
| Range Options | 0–1 g/L or 0–0.5 g/L OH⁻ + CO₃²⁻ (chlor-alkali brine application) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% of full scale |
| Repeatability | ±1% of full scale |
| Response Time | 3–12 minutes per analysis cycle |
| Operating Ambient Temperature | –20 °C to +60 °C |
| Dimensions (H×W×D) | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Requirement | 10–32 VDC or 90–240 VAC |
| Power Consumption | 100 W |
| Analog Outputs | Up to eight isolated 4–20 mA channels |
| Digital Communication | Modbus RTU (RS232/RS485), Modbus TCP/IP |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | AccuSeries |
| Measurement Principle | Potentiometric Titration (pH electrode endpoint detection) |
| Range Options | 0–1 g/L or 0–0.5 g/L (customizable per application) |
| Accuracy | ±1% of full scale |
| Linearity | ±1% of full scale |
| Repeatability | ±1% of full scale |
| Response Time | 8–12 minutes |
| Operating Temperature | –20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 300 W |
| Analog Outputs | up to eight 4–20 mA isolated channels |
| Communication Protocols | Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, GUI PC direct connection |
| Relay Outputs | configurable alarm and control relays |
| Sample Streams | up to six independent flow paths (modular architecture) |
| Enclosure Rating | NEMA 4X / IP66 equivalent (corrosion-resistant, H₂S/Cl₂ tolerant, humidity resistant) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AccuSeries |
| Pricing | Upon Request |
| Measurement Principle | Potentiometric Titration with pH Endpoint Detection |
| Range Options | 0–1 g/L or 0–0.5 g/L (customizable per application) |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 3–12 minutes |
| Operating Temperature | –20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Consumption | 100 W |
| Supply Voltage | 10–32 VDC or 90–240 VAC |
| Analog Outputs | Up to eight 4–20 mA isolated outputs |
| Communication Protocols | Modbus RTU (RS-232/RS-485), Modbus TCP/IP, USB, GUI PC Direct Connection |
| Relay Outputs | Configurable alarm and control relays |
| Sample Streams | Up to six independent flow paths (modular expansion) |
| Enclosure Rating | IP65-rated corrosion-resistant housing |
| Compliance | Designed for hazardous area compatibility (Class I, Div 2 optional), supports GLP/GMP audit trails via software logging |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AccuSeries |
| Price | Upon Request |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Range | 0–10,000 ppb Na⁺ |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 3–12 minutes |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 100 W |
| Analog Outputs | Up to eight 4–20 mA isolated outputs |
| Communication Protocols | Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, GUI direct PC connection |
| Relay Outputs | Configurable alarm and control relays |
| Sample Pathways | Up to six independent flow paths |
| Enclosure Rating | IP65-rated corrosion-resistant cabinet (H₂S/Cl₂ resistant, moisture-proof) |
| System Architecture | Physically segregated electronics and fluidic modules |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries-LPA Online Analyzer |
| Instrument Type | Online Multi-Ion Analyzer |
| Measurement Range | 0–200 ppb (as Ca²⁺/Mg²⁺) |
| Detection Limit | <1 ppb (typical, method-dependent) |
| Response Time | ≤10 min (T90) |
| Accuracy | ±1% of reading |
| Operating Temperature | −20 to +60 °C |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs |
| Sample Flow Paths | Up to 6 independent streams (modular configuration) |
| Enclosure Rating | IP65 (corrosion-resistant housing, H₂S/Cl₂ tolerant) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries-LPA Online Analyzer |
| Type | Online Analyzer |
| Measurement Principle | Pyrazolone-based Colorimetric Method |
| Detection Range | 0–1 ppm CN⁻ |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs |
| Sample Handling | Up to 6 Independent Flow Paths |
| Enclosure Rating | Corrosion-Resistant Design (H₂S/Cl₂ Resistant, Humidity-Protected) |
| Compliance | Designed for Continuous Emission Monitoring Systems (CEMS) and Industrial Wastewater Compliance Applications |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries-LPA |
| Instrument Type | Online Analyzer |
| Measurement Principle | Molybdenum Blue Colorimetric Method |
| Range | 0–5000 ppb SiO₂ (as soluble silica) |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs |
| Sample Flow Paths | Up to 6 modular channels |
| Environmental Rating | Corrosion-resistant housing |
| Compliance | Designed for continuous operation in industrial water monitoring per ASTM D859, ISO 10530, and EPA Method 365.3 contexts |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | AccuSeries1 |
| Measurement Principle | Potentiometric Acid-Base Titration with pH Endpoint Detection |
| Range Options | 0–20 mg/L or 0–500 mg/L (customizable per application) |
| Accuracy | ±1% of Full Scale |
| Linearity | ±1% of Full Scale |
| Repeatability | ±1% of Full Scale |
| Response Time | 8–12 minutes |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 300 W |
| Analog Outputs | up to eight 4–20 mA isolated channels |
| Communication Protocols | Modbus RTU/ASCII (RS232/RS485), Modbus TCP/IP, USB, GUI PC Direct Connection |
| Digital I/O | Relay outputs, status alarms |
| Enclosure Rating | IP65-rated corrosion-resistant housing |
| Sample Stream Capacity | Up to six independent flow paths |
| System Architecture | Physically segregated electronics and wet chemistry modules |
| Compliance | Designed for continuous operation in hazardous area-adjacent industrial environments |
| Brand | GALVANIC |
|---|---|
| Origin | USA |
| Model | MoniSpec Colorimeter |
| Optical Principle | Dual-channel absorbance and turbidity detection with 12° forward scatter or 90° side scatter geometry |
| Wavelength Range | 380–1100 nm (xenon lamp) |
| Measurement Range | 0–0.1 AU to 0–5 AU |
| IP Rating | IP65 / NEMA 4X |
| Hazardous Area Certification | ATEX Ex d IIC/T6 (Zone 1 & 2 not applicable) |
| Flow Cell Materials | Stainless steel (optional Ti, PTFE) |
| Window Material | Sapphire (optional borosilicate glass, PMMA) |
| Seal Material | FKM (optional FFKM, EPDM, silicone) |
| Process Connections | DIN, ANSI, NPT |
| Max Sensors per Transmitter | 4 |
| Output Units | NTU, JTU, AU, EBC, ppm, g/L, %TS, Hazen, ASTM, Saybolt |
| Data Logging | 8,000 points with backup restore |
| Communication | RS-232C / RS-485 (Modbus RTU) |
| Cleaning | CIP-compatible, optional spray nozzle |
| Calibration/Maintenance Interval | Up to 24 months (application-dependent) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Monispec-AD |
| Price | Upon Request |
| Accuracy | ±0.1% FS |
| Linearity | ±0.1% FS |
| Repeatability | ±0.1% FS |
| Sensitivity | ±0.1% FS |
| Process Temperature Range | 0–140 °C (customizable up to 200 °C) |
| Process Pressure Range | 0–16 bar (customizable up to 30 bar) |
| Response Time | <1 s |
| Power Supply | 220 V AC or 24 V DC |
| Analog Output | 4–20 mA (loop-powered) |
| Measurement Ranges | Redness (0–8 Lov or 8–20 Lov), Yellowness (0–15 Lov or 15–80 Lov), Chlorophyll Concentration (0–1 ppm, typical range 0–200 ppb) |
| Process Connection | 10–100 mm (½″–4″ NPT or flanged) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Monitek Nickel Ion Online Analyzer |
| Price Range | USD 13,500 – 27,000 |
| Brand | Galvanic |
|---|---|
| Origin | Germany |
| Model | MONITEK TA6-FS |
| Instrument Type | Beer-Specific Turbidimeter |
| Application | Laboratory |
| Measurement Principle | Dual-Angle Light Scattering (12° Forward Scatter & 90° Side Scatter) |
| Measurement Range | 0–100 EBC (90°), 0–80 EBC (12°) |
| Sensitivity | 0.01 EBC |
| Repeatability | <1% (optical cell) |
| Measurement Time | ~17 s |
| Temperature Control | Up to 60 °C |
| Power Supply | 230 V AC (115 V AC optional) |
| Power Consumption | 60 VA |
| Interface | RS-232 |
| Dimensions (L×W×H) | 450 × 300 × 300 mm |
| Weight | 9 kg |
| Compliance | Designed for ISO 7027-compliant turbidity measurement in beverage matrices |
| Sample Vessel | Standard beer/beverage bottles (automatically rotated) |
| Automatic Compensation | Bottle surface irregularities, scratches, color, and background chromaticity |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Monitek Tin Ion Online Analyzer |
| Price Range | USD 13,500 – 27,000 |
| Brand | GALVANIC |
|---|---|
| Origin | USA |
| Model | Monitek-MoniTurb |
| Type | Online Turbidimeter |
| Measurement Range | 0–500 NTU |
| Resolution | 0.1 NTU |
| Operating Temperature | −10°C to 50°C |
| Accuracy | ±1% |
| Protection Rating | IP65 / NEMA 4X |
| Hazardous Area Certification | ATEX Ex d IIC/T6 |
| Light Source | Gas-filled lamp (380–1100 nm), ~2-year lifetime |
| Flow Cell Material | Stainless steel (optional Ti, PTFE) |
| Viewing Window | Sapphire (optional borosilicate, acrylic) |
| Seals | FKM (optional FFKM, EPDM, silicone) |
| Process Connections | DIN, ANSI, NPT |
| Scattering Angles | 12° forward scatter and 90° side scatter |
| Data Logging Capacity | 8,000 entries |
| Communication | RS-232C / RS-485 (Modbus RTU) |
| Programmable Units | NTU, JTU, AU, EBC, ppm, g/L, %TS, Hazen, ASTM, Saybolt |
| Cleaning | CIP-compatible, optional spray nozzle |
| Calibration/Maintenance Interval | Up to 24 months (application-dependent) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ViscoSite (Nametre) |
| Price Range | USD 14,000 – 70,000 |
| Measurement Principle | Torque-based Micro-Oscillation Rheometry |
| Probe Types | LV, MV, HV, XV (XV only for VL800) |
| Viscosity Range | 0.1–5,000,000 cP (customizable beyond) |
| Calibration | NIST-traceable Newtonian fluids pre-calibrated at factory |
| Accuracy | ±1% of reading |
| Repeatability | ±0.25% of reading |
| Linearity | ±1% |
| Operating Temperature (Process) | –40 to 450 °C (with optional cooling jacket) |
| Internal Probe Temp Range | –40 to 200 °C |
| Max Flow Velocity | 2 m/s |
| Vibration Frequency | Up to 700 Hz |
| Probe Materials | 316L stainless steel, NEMA 4X-rated housing |
| Process Connection | ANSI 3" 300#, DN80 PN40 flange |
| Cable | MIL-SPEC, up to 1000 m |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Type | In-line Process Turbidimeter |
| Model | MoniTurb-F |
| Measurement Range | 0–500 NTU |
| Resolution | ±2% of full scale |
| Accuracy | ±0.5% of full scale |
| Operating Ambient Temperature | −10 °C to +60 °C |
| Process Temperature | up to 140 °C |
| Process Pressure | up to 220 psi (15 bar) at ambient temperature |
| Wetted Materials | 316L stainless steel (1.4404) standard, customizable |
| Optical Path Length | pipe-diameter-dependent |
| Cable Length | up to 100 m |
| Enclosure Rating | NEMA 4X / IP66 |
| Hazardous Area Options | Class I, Div. 1 |
| Output Interface | Compatible with Monitek® Messenger transmitter |
| Detection Principle | 12° forward scatter photometry |
| Optional Configurations | MoniTurb-S (90° side scatter), MoniTurb-FS (dual-angle scatter) |
| Calibration Interval | 12 months |
| Color Compensation | Yes |
| Optional Air/Water Jet Cleaning System | Available |
| Process Connections | DIN, ANSI, SMS, NPT, APV, TH, Tri-Clamp |
| Units Supported | NTU, JTU, AU, EBC, ppm, g/L, % concentration |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek |
| Measurement Principle | 12° Forward Light Scattering |
| Detection Range | 0–0.5 mg/L to 0–8000 mg/L (oil or water phase) |
| Optical Wavelength | 380–1100 nm |
| Repeatability | ±1% |
| Flow Cell Material | 316L Stainless Steel (Ti/PTFE optional) |
| Window Material | Sapphire (Borosilicate/PMMA optional) |
| Seal Material | FKM (FFKM/EPDM/Silicone optional) |
| Process Connection | DIN/ANSI Flange, NPT |
| Max. Process Pressure | PN16 / ANSI Class 150 |
| Max. Process Temperature | 140 °C |
| IP Rating | IP65 / NEMA 4X |
| ATEX Certification | Ex d IIC T6 (Zone 1 & Zone 2) |
| Cleaning | CIP-compatible, optional spray nozzle |
| Calibration Interval | Up to 24 months (application-dependent) |
| Power Supply | 90–260 VAC, 50–60 Hz (24 VAC/DC optional) |
| Analog Outputs | Up to 4 × 4–20 mA (independent) |
| Digital Interface | RS-232C / RS-485 (Modbus RTU) |
| Relay Outputs | 4 programmable (48 V / 2 A) |
| Data Logger | 8,000-point internal memory with backup restore |
| Environmental Operating Range | −10 °C to +50 °C |
| Power Consumption | ≤50 VA |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek MoniSpec-AD |
| Measurement Principle | Dual-Wavelength Absorption Photometry |
| Housing Material | 1.4571 (316L Stainless Steel) |
| Enclosure Rating | NEMA 4X (IP66) |
| Process Connections | DIN, ANSI, SMS, NPT, APV, TH, Tri-Clover |
| Path Length Options | 10–150 mm (1/2"–6") |
| Max Operating Pressure | 15 bar at ambient temperature |
| Max Operating Temperature | 140 °C |
| Fiber Optic Cable Length | Up to 100 m |
| Spectral Range | 390–850 nm |
| Hazardous Area Certification | Class I Div. 1 |
| Compatible Transmitter | Monitek Messenger |
| Measurement Range | Up to 4 Absorbance Units (AU) |
| Accuracy | ±0.5% of reading |
| Repeatability | ±1% |
| Calibration Interval | 12 months |
| Optional Features | Pneumatic cleaning jet |
| Compliant Standards | APHA/Hazen, ASTM D1209, ASTM D1500, ISO 6271, EBC 201, Lovibond |
| Brand | Galvanic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Form Factor | Benchtop/Laboratory |
| Measurement Ranges | 0–250 EBC (90° side scatter), 0–80 EBC (12° forward scatter) |
| Resolution | 0.01 EBC (sensitivity), 0.05 NTU (display resolution) |
| Operating Temperature | 0–30 °C |
| Accuracy | <2% of reading |
| Repeatability | <1% (with standardized cuvettes) |
| Power Supply | 230 V AC (115 V AC optional) |
| Power Consumption | 60 VA |
| Dimensions | 450 × 300 × 300 mm |
| Weight | 9 kg |
| Measurement Time | ~17 s |
| Interface | RS-232 |
| Cuvette Rotation | Motorized, 360° continuous |
| Automatic Surface Defect Compensation | Yes |
| Color Compensation Algorithm | Embedded |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Monitek Turbidimeter |
| Configuration | Online Process Turbidimeter |
| Measurement Range | 0–8000 mg/L (as SiO₂) |
| Resolution | 0.1 mg/L |
| Operating Ambient Temperature | −10 °C to +50 °C |
| Accuracy | ±1 % of reading |
| Optical Principle | 12° forward scatter detection |
| Wavelength Range | 390–900 nm |
| Repeatability | ±1 % |
| Process Connection | DN25–DN125 (½″–5″) |
| Max Process Pressure | PN16 / ANSI Class 150 |
| Max Process Temperature | 140 °C |
| Sensor Housing Material | 316L stainless steel (Ti, Mn-Co alloy optional) |
| Window Material | Sapphire or metal-backed glass |
| Gasket Options | FKM (FFKM, EPDM, silicone available) |
| Enclosure Rating | IP65 / NEMA 4X |
| Cleaning | Optional integrated spray nozzle |
| Sterilization | CIP-compatible |
| Hazardous Area Certification | ATEX Zone 1 or Zone 2 |
| Power Supply | 90–260 VAC, 50–60 Hz (24 VAC/DC optional) |
| Power Consumption | ≤50 VA |
| Analog Outputs | Up to 4 × 4–20 mA (isolated) |
| Digital Interface | RS-232C / RS-485 Modbus RTU (optional) |
| Relay Outputs | 4 programmable relays (48 V / 2 A) |
| Digital Inputs | 4 × 5 V (optional) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek1 |
| Type | Online Analyzer |
| Application | Real-time turbidity and total suspended solids (TSS) measurement in liquid process streams |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Monitek Ultrasonic |
| Measurement Principle | Ultrasonic Reflectance |
| Frequency Options | 5 MHz / 15 MHz |
| Enclosure Rating | NEMA 4X / IP65 |
| Max Process Pressure | 20 bar (customizable higher) |
| Max Process Temperature | 90°C (110°C with air cooling) |
| Sensor Material | 316 SS / PEEK |
| Sensor Length | ~300 mm (custom lengths available) |
| Cable Length | 100 m |
| Measurable Range | 0–100 ppm to 0–10,000 ppm (configurable |
| Output Units | ppm, mg/L, %, EBC, etc. |
| Accuracy | ±1% |
| Hazardous Area Certifications | Ex Zone I, Ex Zone II, Class 1 Div. 1 |
| Maintenance | No consumables |
| Installation | Retractable probe via 1" ball valve adapter |