Generic
Filter
Showing 631–660 of 1032 results
| Key | Test Volume: 90 × 90 × 90 cm (W×D×H) |
|---|---|
| Net Weight | 320 kg |
| External Dimensions | 900 × 700 × 1600 mm (W×D×H) |
| Internal Chamber | Cylindrical, Ø400 mm × L600 mm (HAST-45 type) |
| Inner Liner Material | SUS316 stainless steel (3 mm thick) |
| Insulation | Rockwool + rigid polyurethane foam |
| Heating Element | Titanium steam generator tube |
| Temperature Range | 20°C ±15°C |
| Humidity Range | 75–100% RH |
| Dust Concentration Options | 100 mg/m³, 3000 mg/m³, 5000 mg/m³, 60000 mg/m³ |
| Dust Velocity | 5 m/s (for selected concentrations) |
| Cycle Timing | 0–999 sec / 0–99 hr (dual-range programmable) |
| Control System | Color touchscreen PLC with PT-100 sensors, P.I.D. saturation control, analog pressure gauge, manual fill valve with auto-refill capability |
| Compliance | GB/T 10586–1989, GB 2423.3–1993 (IEC 60068-2-3), MIL-STD-810D Method 502.2, GJB 150.9–1986, GB 2423.34–1986, MIL-STD-883C Method 1004.2 |
| Temperature Range | +100 °C to +132 °C (saturated steam temperature) |
|---|---|
| Humidity | 100% RH (saturated steam) |
| Operating Pressure | 1.5–3.2 kg/cm² (absolute pressure) |
| Time Setting Range | 000–999 hours |
| Pressure Ramp Time | ~45 minutes to reach 1.04 kg/cm² from ambient |
| Temperature Uniformity | ±0.5 °C |
| Temperature Display Resolution | 0.1 °C |
| Pressure Stability | ±0.2 kg/cm² |
| Controller | Microprocessor-based PID with PT-100 platinum RTD sensor |
| Safety Features | Interlocked door switch, mechanical safety valve, ABS thermal-insulated door cover, integrated silicone gasket |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PELCO LatticeAx 420 |
| Price Range | USD 0–15,000 |
| Maximum Scribe Speed | 500–600 mm/min |
| Application Scope | Laboratory Use |
| Positioning Accuracy | ±10 µm |
| Indentation Step Resolution | 5 µm |
| Optical Magnification | 0.58–7× (zoom, parfocal, monocular) |
| Camera | Color CCD |
| Diamond Scribing Tip | Polished Single-Point Diamond |
| Focusing Mechanism | Coarse + Fine Focus Stage |
| Footprint | Compact Industrial Platform |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AAnalyst 800 |
| Rental Rate | USD 1,150/month (excl. tax & shipping) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | LS-55 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OilPrep 4 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PGC2009 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PGC5007B |
| Pricing | Available Upon Request |
| Key | Temperature Range: −40 °C to +150 °C (optional down to −70 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temp. Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temp. Uniformity | ±0.5 °C |
| Temp. Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen controller |
| Internal Construction | SUS304 stainless steel |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (220 V optional) |
| Compliance | GB10589, GB10592, GB11158, GB/T5170.2, GB/T5170.5, GB2423.1/2/22, GB2424.1 |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VersaProbe III |
| Price | USD 950,000 (FOB Yokohama) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PHS-3C |
| Pricing | Available Upon Request |
| Accuracy Class | 0.01 |
| pH Range | 0.00–14.00 pH |
| mV Range | ±1400 mV |
| Resolution | 0.01 pH / 1 mV / 0.1 °C |
| Temperature Compensation | 0–60 °C |
| Basic Error (pH) | ±0.1 pH |
| Input Impedance | ≥3 × 10¹¹ Ω |
| Input Current | ≤1 × 10⁻¹¹ A |
| Repeatability (pH) | ≤0.05 pH |
| Stability | ±0.05 pH ±1 digit / 3 h |
| Dimensions (L×W×H) | 220 × 160 × 65 mm |
| Weight | 0.3 kg |
| Power Supply | DC 6 V |
| Operating Environment | 5–50 °C, RH ≤85%, No Strong Vibration or Magnetic Interference |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Sensor Highway II / III |
| Instrument Category | Acoustic Emission (AE) & Multi-Parameter Structural Health Monitoring System |
| Operating Temperature Range | -35°C to +70°C |
| Power Supply | 10–28 VDC or 95–250 VAC |
| Power Consumption | 15 W (typical) |
| Dimensions | 40 cm × 50 cm × 20 cm |
| AE Channels | Up to 16 (expandable via four 4-channel micro-AE cards) |
| AE Frequency Bandwidth | 1 kHz – 1 MHz |
| Vibration Bandwidth | 1 Hz – 20 kHz |
| A/D Resolution | 18-bit |
| Sampling Rate | 20 MS/s (AE), 10 kS/s (16 low-speed external parameter channels) |
| IP Rating | IP67-rated enclosure (for outdoor deployment) |
| Communication Interfaces | Gigabit Ethernet, RS-232, RS-422, USB, CompactFlash |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PICO-RHEED |
| Price | USD 220,000 (FOB Yokohama) |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | R-Series |
| Price Range | USD 135,000 – 270,000 (FOB Helsinki) |
| Substrate Size | 50–200 mm (2″–8″, 8″ available on request) |
| Process Temperature | Up to 500 °C |
| Precursor Channels | 2–6 (gas, vaporized liquid, or solid-source compatible) |
| Weight | 200 kg |
| Dimensions (W × H × D) | 70 × 105 × 92.5 cm |
| Uniformity | < ±1% across 200 mm wafers (typical, SiO₂ on Si) |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PixelCam™ |
| Pricing | Upon Request |
| Key | Temperature Range: −40 °C to +150 °C (optional −120 °C to +150 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temp. Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temp. Uniformity | ±0.5 °C |
| Temp. Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen controller |
| Internal Construction | SUS304 stainless steel |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (custom 220 V available) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | PLC Industrial Control System |
| Pricing | Available Upon Request |
| Brand | Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 16,500 (FOB) |
| Compliance | MIL-STD-810, IEC 60068-2-29, GB/T 2423.5–2022, GJB 150.18A–2012, GJB 360B–2009 |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NGB-R |
| Price Range | USD 270,000 – 680,000 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PoolDirect 9-in-1 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PoolDirect |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Portable |
| Price Range | USD 1,400 – 7,200 (est.) |
| Laser Source | Pulsed Solid-State Nd:YAG (1064 nm) |
| Detector | High-Sensitivity Avalanche Photodiode (APD) Array |
| Operating Wavelength | 1064 nm |
| Maximum Detection Altitude | 8 km (a.s.l.) |
| Pulse Repetition Frequency | 4 kHz |
| Spatial Resolution | Adjustable (7.5 m / 15 m / 30 m) |
| Laser Safety Class | Class 3B (IEC 60825-1) |
| Enclosure Rating | IP65 |
| Power Supply | 220 V AC or 12 V DC (battery-compatible) |
| Scan Mechanism | Integrated European-Made 3D Galvanometric Motor (±90° azimuth, ±45° elevation) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | 9000D |
| Price | USD 13,800 (FOB Beijing) |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption Spectroscopy |
| Gas Channels | CO, CO₂, CH₄, O₂ |
| Display | Four 3½-digit LCDs (simultaneous real-time concentration readouts) |
| Response Time | T₀–T₉₀ ≤ 15 s |
| Linearity | ≤ ±2% FS |
| Repeatability | ≤ 1% FS |
| Zero Drift | ≤ ±2% FS / 4 h |
| Operating Environment | −10 °C to +50 °C, 20–95% RH (non-condensing) |
| Power Supply | 24 V DC (internal rechargeable Li-ion battery + AC adapter) |
| Weight | 4.2 kg (portable configuration) |
| IP Rating | IP54 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PRE-2000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.1–100 mL/min |
| Flow Accuracy | ±1.0% |
| Flow Precision | ≤0.2% RSD |
| Flow Reproducibility | ≤0.2% RSD |
| Maximum Pressure | 5000 psi |
| Wavelength Range | 190–800 nm (±1 nm) |
| Wavelength Reproducibility | ±0.1 nm |
| Baseline Noise | ≤0.15 × 10⁻⁵ AU |
| Data Acquisition Rate | 100 Hz |
| Pump Configuration | Dual Isocratic or Gradient Capable |
| Gradient Composition Range | 0–100% B |
| Auto-Cleaning Pump Head | Integrated |
| Maintenance Interval | ≥6 months under continuous operation |
| Key | Temperature Range: +100°C to +147°C (saturated steam temperature) |
|---|---|
| Humidity Range | 75–100% RH (saturated steam, up to 75% RH at 47°C) |
| Humidity Stability | ±3% RH |
| Operating Pressure | 1.2–2.89 kgf/cm² (inclusive of 1 atm ambient) |
| Time Setting Range | 0–999 hours |
| Pressurization Time | ~45 min to reach 1.04 kgf/cm² from ambient |
| Temperature Uniformity | ±0.5°C |
| Temperature Display Resolution | 0.1°C |
| Pressure Uniformity | ±0.1 kgf/cm² |
| Humidity Uniformity | ±3% RH |
| Internal Chamber Design Pressure Rating | 4.0 kgf/cm² |
| Vacuum Pre-Purge Function | Integrated |
| Safety Interlock | Dual-redundant pressure/temperature-sensing door lock |
| Water Autonomy | Up to 48 h continuous operation per fill (optional fully automated water replenishment system) |
| Weighing Range | 225 g |
|---|---|
| Readability | 0.1 mg |
| Taring Range | 225 g |
| Reproducibility | ≤ 0.1 mg |
| Linearity Error | ±1 mg |
| Response Time | ~2–3 s |
| Stability Setting | 3-step adjustable |
| Operating Temperature | 0–40 °C |
| Sensitivity Drift (10–30 °C) | ±2 ppm/°C |
| Input Voltage | 115/230 V AC |
| Voltage Tolerance | +15 % / −20 % |
| Frequency | 50–60 Hz |
| Power Consumption | 6 VA |
| Display | Fluorescent (optional) |
| Dimensions (L×W×H) | 210 × 340 × 89 mm |
| Pan Diameter | Ø80 mm (chromium-nickel steel) |
| Net Weight | 3.7 kg |
| Internal Calibration | Motor-driven SCS system with built-in precision weights |
| Compliance | ISO 9001, ISO/IEC 17025 compatible workflows, GLP/GMP-ready audit trail support |
| Origin | Switzerland |
|---|---|
| Manufacturer | Precisa Instruments AG |
| Model | XS4250C |
| Weighing Range | 4250 g |
| Readability | 10 mg |
| Taring Range | 4250 g |
| Reproducibility | ≤10 mg |
| Linearity Error | ±15 mg |
| Stabilization Time | 2–3 s |
| Stability Setting | 3-step adjustable |
| Operating Temperature | 0–40 °C |
| Sensitivity Drift (10–30 °C) | ±2 ppm/°C |
| Supply Voltage | 115/230 V AC |
| Voltage Tolerance | +15% / −20% |
| Frequency | 50–60 Hz |
| Power Consumption | 6 VA |
| Display | Optional fluorescent display |
| Dimensions (L×W×H) | 210 × 340 × 89 mm |
| Pan Material | Chrome-nickel steel |
| Pan Size | 170 × 170 mm |
| Net Weight | 4.5 kg |
| Key | Temperature Range: +110 °C to +132 °C |
|---|---|
| Temp. Uniformity | ±1.5 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Range | 75–100 % RH (saturated steam) |
| Humidity Uniformity | ±3.0 % RH |
| Humidity Stability | ±1.5 % RH |
| Pressure Range | 0–2 kg/cm² (configurable up to 4 kg/cm²) |
| Max. Safety Pressure | 4 kg/cm² |
| Vacuum Preconditioning | Integrated particulate-filtered air intake (<1 µm) |
| Test Duration | 0–999 h |
| Steam Circulation | Natural convection |
| Water Consumption | Low—supports continuous operation up to 200 h per fill |
| Compliance | GB/T 10586–1989, GB/T 2423.3–1993 (IEC 60068-2-3), MIL-STD-810D Method 502.2, GJB 150.9–1986, GB/T 2423.34–1986, MIL-STD-883C Method 1004.2 |
| Key | Chamber Dimensions (W×D×H): 800×800×800 mm or 1000×1000×1000 mm |
|---|---|
| Rated Voltage | 220 V ±10%, 50 Hz |
| Sample Rack Height Adjustment Range | 0–750 mm |
| Timer Range | 0–99 h 59 min |
| Timer Accuracy | ±1 min |
| Cycle Control (Load/Blow) | 0–99 h 59 min / 1 s–9999 min |
| Dust Concentration | 2–4 kg/m³ (dry talcum powder) |
| Powder Specification | Passes 75 µm square mesh sieve (wire diameter 50 µm) |
| Internal Construction | SUS201 stainless steel chamber |
| External Casing | A3 steel with electrostatic powder coating |
| Ambient Operating Conditions | 15–35 °C, 45–75 %RH (uncontrolled |
| Control System | PLC-based HMI touchscreen controller with PT100 temperature sensors |
| Safety Protections | Overtemperature cutoff, phase-loss detection, earth-leakage circuit breaker, reinforced tempered glass viewport (800×800 mm or 1000×1000 mm) |
| Airflow Design | Non-laminar, vertically oriented recirculating duct system |