Generic
Filter
Showing 571–600 of 5668 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | B8510E-DTH |
| Quotation | Available Upon Request |
| Tank Volume | 20.81 L |
| Chamber Dimensions | 492 × 292 × 152 mm |
| Ultrasonic Frequency | 40 kHz |
| Heating Range | 0–69 °C |
| Timer Range | 0–59 min (ultrasonic), 1–99 min (extended ultrasonic mode) |
| Heating Power | 500 W |
| Ultrasonic Power Output | 380 W |
| Total Power Consumption | 880 W |
| Input Voltage/Frequency | 220 V, 50/60 Hz |
| Construction Material | Polypropylene (PP) Body |
| Transducer Type | Langevin-type Metal/Ceramic Stack |
| Mounting Method | Adhesive-bonded Vertical Transducers |
| Control Interface | Digital LED Display with Dual-Temperature Readout (Current Bath Temp & Setpoint) |
| Lid Function | Hinged Sound-Dampening Lid with Integrated Drip Tray and Drain Valve |
| Safety Features | IPX1-rated Electronics, Molded Rubberized Power Switch, Optimized Water-Level Calibration Mark |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | BI-DNDC |
| Pricing | Available Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | BLQX-220 |
| Price | USD 19,200 (FOB Jiangsu) |
| Construction | AISI 304 Stainless Steel Cabinet & Chamber |
| Door | Single Front-Loading Pull-Out Door |
| Control System | PLC-Based Microprocessor Controller with LCD Interface |
| Wash Programs | Pre-Programmed & User-Defined Cycles |
| Water Inlets | Three Independent Connections (Cold Water, Hot Water, Deionized Water) |
| Drying System | Heated Air Circulation with Dual-Layer Rack Support |
| Filtration | Integrated HEPA-Filtered Recirculated Air System |
| Safety Protections | Overtemperature Cut-off, Phase Failure Detection, Door Interlock, Leakage Current Protection |
| Optional Module | Integrated Pure Water Generation System (UPW, ≥18.2 MΩ·cm resistivity) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BMF11/7 |
| Instrument Type | Box-Type Muffle Furnace |
| Max Temperature | 1100 °C |
| Max Holding Temperature | 1050 °C |
| Temperature Uniformity | ±5 °C |
| Effective Chamber Volume | 7 L |
| Internal Dimensions (W×D×H) | 178 × 305 × 125 mm |
| Heating Element | Dual-Side Ceramic Fiber Insulated with Embedded Resistance Wire |
| Insulation Material | Low-Heat-Capacity Ceramic Fiber |
| External Casing | Galvanized Steel with Polyester Powder Coating |
| Temperature Sensor | Type N Thermocouple |
| Power Supply | 240 V, Single-Phase |
| Rated Power | 2 kW |
| Net Weight | 48 kg |
| Door Operation | Top-Hinged or Front-Hinged Insulated Door with Auto-Cut Safety Interlock |
| Exhaust | Integrated Standard Flue |
| Controller Options | 2116 (Basic On/Off), 2216 (PID Display Only), 2416CG (8-Step Programmable), 2408CP (16-Step Programmable), 2408P4 (4 Stored Programs, 16-Step), 2408CM (20 Stored Programs, 16-Step) |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Cuff Model | NO. 10 |
| Pricing | Available Upon Request |
| Animal Size Range | Canine, NHP, Feline, Rabbit, Guinea Pig |
| Measurement Method | Oscillometric (Air-Vibration) |
| Display | High-Contrast LCD with Real-Time Pulse Waveform Monitoring |
| Data Storage | Internal Memory ≥ 100 Sessions |
| Interface | RS-232/USB for PC Communication |
| Software Included | BPView™ Data Management Suite (Waveform Capture, Export, Audit Trail) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic (China) |
| Model | BRS-10 |
| Pricing | Upon Request |
| Temperature Range | RT+10°C to 100°C |
| Temperature Uniformity | ≤ ±2°C |
| Humidity Range | 30–98% RH |
| Working Volume | 5–200 m³ (Customizable) |
| Refrigeration System | Imported Hermetic Compressor |
| Control System | PID-Based Programmable Controller with Digital Display |
| Interior Material | AISI 304 Stainless Steel (Optional Configurations Available) |
| Exterior Finish | Powder-Coated Cold-Rolled Steel |
| Air Circulation | Forced-Air Convection with Low-Noise Axial Fans |
| Electrical Supply | 380 V, 50 Hz |
| Safety Protections | Overcurrent, Overvoltage, Ground-Fault, and Thermal Cut-off Protection |
| Ambient Operating Temperature | 10–35°C |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | BT-200 |
| Price | USD 465 (FOB Shanghai) |
| Dimensions | 200 × 230 × 140 mm |
| Channels | Dual independent |
| Flow Rate Range | 2 × (1–6800) mL/h |
| Maximum Back Pressure | ≥2.5 kg/cm² |
| Display | LED digital interface with real-time flow monitoring |
| Drive Mechanism | Brushless DC motor with precision roller assembly |
| Tubing Compatibility | Standard silicone or Tygon® tubing (ID 1.6–6.4 mm) |
| Enclosure Rating | IP20 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BT-600C |
| Dimensions (W×D×H) | 240 × 300 × 170 mm |
| Number of Channels | 6 |
| Flow Rate per Channel | 10–30,000 mL/h |
| Maximum Pressure | ≥2 kgf/cm² |
| Display | Digital LED |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | CE-marked for laboratory use under IEC 61010-1 |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | BT100-12 |
| Price | USD 845 (FOB Shanghai) |
| Output Channels | 12 |
| Flow Rate per Channel | 0.3–5000 mL/h |
| Maximum Pressure | ≥2.5 kg/cm² (≈245 kPa) |
| Dimensions (W×D×H) | 120×350×120 mm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BT90 |
| Price Range | USD 21,000–28,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 1–9500 nm |
| Repeatability | <1% RSD |
| Measurement Time | 10–15 seconds |
| Laser Source | 20 mW, 635 nm Solid-State Diode Laser |
| Scattering Angle | 90° |
| Detector | High-Sensitivity PMT |
| Correlator | 200 Physical Channels, 1–5 µs Dynamic Sampling & Delay Time |
| Sample Cell Volume | 0.5 mL & 8 mL |
| Temperature Control Range | 15–90 °C |
| Temperature Stability | ±0.5 °C |
| Analysis Modes | NNSL, Multi-Peak, CONTIN |
| Dimensions | 45 × 305 × 210 mm |
| Weight | 15 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | BX-10 |
| Pricing | Available Upon Request |
| Throughput | 100 L/h |
| Minimum Batch Volume | 1,000 mL |
| Pasteurization Temperature Range | 30–90 °C |
| Temperature Control Accuracy | ±1 °C |
| Filling Mode | Automated volumetric filling with liquid-level sensing |
| Compatible Containers | PET, PE, glass bottles, and heat-resistant flexible packaging |
| Safety Interlock | Filling disabled until product temperature reaches setpoint |
| Power Supply | 8.5 kW, 380 V AC, 3-phase 5-wire |
| Net Weight | 50 kg |
| Dimensions (L×W×H) | 550 × 450 × 500 mm |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D130 |
| Pricing | Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D1401 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DH-300 |
| Quotation | Available Upon Request |
| Hydrogen Purity | 99.99999% |
| Flow Rate | 0–300 mL/min |
| Output Pressure | 0–0.5 MPa |
| Pressure Stability | < 0.0001 MPa |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 300 W |
| Dimensions (W×D×H) | 380 × 200 × 370 mm |
| Net Weight | ~15 kg |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DHZ-DA |
| Price | USD 3,750 (FOB Jiangsu) |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Timer Range | 0–999 min |
| Oscillation Frequency | 40–280 rpm |
| Oscillation Amplitude | 26 mm |
| Temperature Range | 0–60 °C |
| Temperature Uniformity | ±0.5 °C |
| Temperature Accuracy | ±0.1 °C |
| Platform Quantity | 1 |
| Platform Dimensions | 880 × 540 mm |
| Max Load Capacity | 3000 mL × 8 (Erlenmeyer flasks), or 1000 mL × 24, or 500 mL × 40, or 250 mL × 60 |
| Display | LED Digital |
| Input Power | 750 W |
| Overall Dimensions (W×D×H) | 1200 × 700 × 990 mm |
| Net Weight | 180 kg |
| Power Supply | 220 V, 50 Hz |
| Illumination | 20 W LED Interior Light |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DMF-1000 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DV-II+ Pro |
| Pricing | Available Upon Request |
| Torque | 673.7 dyn·cm |
| Speed Range | 0.01–200 rpm (54 programmable speeds) |
| Spindles | 4 standard spindles included |
| Viscosity Range | 15–2,000,000 cP |
| Display | Digital LCD showing viscosity (cP), % torque, temperature (°C), rotational speed (rpm), and spindle identification |
| Control Interface | Microprocessor-based touchpad control with RS-232 interface for PC connectivity |
| Temperature Sensing | Compatible with RTD temperature probes (e.g., PT100) for real-time thermal monitoring |
| Data Acquisition | Supports DV-Gather™ software for multi-curve overlay (up to 5 simultaneous datasets), synchronized temperature logging, and time-stamped data export |
| Output | RS-232 port for connection to chart recorders or thermal printers for scheduled hard-copy reporting |
| Power Supply | AC 220 V, 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DV-II+Pro |
| Pricing | Available Upon Request |
| Spindle Compatibility | LV/RV/HA/HB |
| Speed Range | 0.01–200 rpm (54 programmable speeds) |
| Viscosity Range (LV) | 1–6,000,000 cP |
| Viscosity Range (RV) | 100–40,000,000 cP |
| Viscosity Range (HA) | 200–80,000,000 cP |
| Viscosity Range (HB) | 800–3,204,000,000 cP |
| Accuracy | ±1% of full-scale reading |
| Repeatability | ±0.2% |
| Integrated RTD Temperature Sensor | Yes |
| Data Output Interface | RS-232 |
| Software Compatibility | RHEOCALC-32 (included), WinTherm (optional), WinGather (optional) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DV-n+PRO |
| Instrument Type | Rotational Viscometer (Not Oscillatory) |
| Speed Range | 0.1–250 rpm |
| Viscosity Range | 1–32,000,000 cP (depending on spindle & model variant) |
| Accuracy | ±1% of full scale |
| Repeatability | ±0.5% |
| Temperature Control | Integrated RTD probe (0–200 °C, ±0.1 °C) |
| Spindle Options | Standard #1–#7 |
| Data Interface | RS-232/USB |
| Compliance | Calibratable to NIST-traceable standard oils |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Brookfield NEW DV1 |
| Instrument Type | Rotational Viscometer |
| Viscosity Range | 0.3–100,000 mPa·s (cP) |
| Speed Range | 0.3–100 rpm (18 programmable speeds) |
| Accuracy | ±1% of full-scale reading |
| Repeatability | ±0.2% |
| Display | Backlit LCD with large-font parameter readout |
| Interface | USB port for Wingather SQ software and direct label printer connectivity |
| Temperature Monitoring | Optional RTD probe support |
| Compliance | Designed to support ASTM D2196, ISO 2555, ISO 3219, USP <911>, and GLP/GMP data integrity requirements |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DV3T |
| Pricing | Upon Request |