Generic
Filter
Showing 751–780 of 1032 results
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPARK-1040 |
| Output Power | 0.5–3 W |
| Wavelength | 1040 nm |
| Pulse Duration | 170 fs – 2.5 ps |
| Spectral Bandwidth | 20–40 nm |
| Repetition Rate | 100 MHz (standard), optional 80–200 MHz with lock-to-clock synchronization |
| Amplitude Noise | <140 Hz RMS (measured over 50 hours) |
| Beam Quality | M² < 1.1 |
| Polarization | Linear |
| Beam Divergence | <2 mrad |
| Beam Diameter (1/e²) | 0.5 mm (standard), optional 0.5–2 mm |
| Interface | Ethernet |
| Laser Head Dimensions | 404 × 249 × 65 mm |
| Controller Dimensions | 483 × 285 × 86 mm |
| Laser Head Weight | 7.5 kg |
| Controller Weight | 2 kg |
| Power Supply | 110–240 V AC, 50–60 Hz, 80 W max |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Multiple Models Available |
| Pricing | Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CNT-NIR Series |
| Price | Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Imspector Series |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SWIR Spectral Camera |
| Pricing | Upon Request |
| Spectral Range | 1000–2500 nm |
| Spectral Resolution | 12 nm (with 30 µm slit) |
| Spectral Sampling Interval | 5.6 nm |
| Spatial Resolution | <15 µm (RMS) |
| F/# | F/2.0 |
| Slit Width | 30 µm (50 µm and 80 µm optional) |
| Effective Slit Length | 9.2 mm |
| Sensor | Stirling-cooled MCT |
| Spectral Channels | 288 |
| Max Frame Rate | 400 fps |
| Spatial Dimension | 384 pixels |
| Output Format | 16-bit Camera Link |
| SNR (peak) | 900:1 |
| Exposure Time | 0.1–20 ms |
| Power Consumption | <50 W (24 V DC input) |
| Operating Temperature | +5 to +40 °C |
| Storage Temperature | −20 to +50 °C |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | V10E Series |
| Pricing | Available Upon Request |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2.8–3.2 nm |
| Spectral Sampling Interval | 0.63–5.8 nm |
| Effective Slit Length | 8.7–11.84 mm |
| Optical Throughput | >50% |
| Relative Aperture | F/2.4 |
| Slit Width | 30 µm |
| Stray Light | ≤0.5% |
| Spectral Bands | 100–300 |
| Sensor Type | CMOS |
| Pixel Array | 1024×1024 to 1600×1200 |
| Pixel Size | 6.45–10.6 µm |
| A/D Conversion | 12-bit |
| Dynamic Range | 60 dB to >1,500:1 |
| Frame Rate (Full Resolution) | 8.9–33 fps |
| Frame Rate (Binned) | up to 120 fps |
| Exposure Time | 0.001–120,000 ms |
| Interface | USB / IEEE 1394 / Ethernet / Camera Link |
| Lens Mount | C-Mount |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpectroCAM SWIR |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SpectrOil M |
| Pricing | Upon Request |
| Product Category | Laboratory Instrument |
| Analytical Capability | Multi-element Quantification (Metals, Additives, Contaminants) |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPEKTRI 80 |
| Price Range | USD 42,000 – 70,000 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SPF290S |
| Measurement Principle | UV-Vis Spectrophotometry with Integrated Diffuse Transmittance Analysis |
| Compliance | AS/NZS 2604:2012 (Australian TNUV), Boots Star Rating Algorithm v2.0, ISO 24443:2021 (in vitro method) |
| Scan Speed | Full spectral acquisition (290–400 nm) in ≤20 s per sample site |
| Data Output | SPF, MPF (Mean Protection Factor), UVA-PF, UVB-PF, UVA/UVB Ratio, Boots Star (1–5 stars), Absorbance spectra (nm), Transmittance profiles (%) |
| Reporting | ASTM E2718-compliant PDF reports with spectral curves, statistical summaries (n = 1–36 replicates), and batch-level formulation comparison matrices |
| Software | Windows-based SPFCalc v4.2 with 21 CFR Part 11 audit trail, user role management, and GLP-compliant data archiving |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SPG |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | NIRSpec |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SPS Series |
| Pricing | Available Upon Request |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SQ-R |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Opti-Melt100 |
| Price | ¥56,500 (CNY) |
| Temperature Range | −10 °C to 400 °C |
| Heating Rate | 0.1–20 °C/min (adjustable in 0.1 °C/min increments) |
| Temperature Repeatability | ±0.3 °C |
| Temperature Accuracy | ±0.3 °C (≤100 °C), ±0.5 °C (≤250 °C), ±0.8 °C (≤400 °C) |
| Capillary Outer Diameter | 1.4–2.0 mm |
| Sample Capacity | 2 capillaries simultaneously |
| Temperature Resolution | 0.1 °C |
| Heating Time | 10 min (50 °C → 350 °C) |
| Cooling Time | 10 min (350 °C → 50 °C) |
| Display | Touchscreen LCD |
| Interface | USB, RS-232 |
| Software | Melt-View™ (Windows-compatible) |
| Power Supply | AC 90–264 V |
| Operating Temperature | 0–40 °C |
| Weight | 4.1 kg |
| Dimensions | 20 × 25 × 21 cm |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SRT 5800 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PC-2000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Maximum Pressure | 6000 psi |
| Flow Rate Range | 0.01–19.98 mL/min |
| Gradient Accuracy | ±0.1% |
| Baseline Noise | 1 × 10⁻⁵ AU |
| Baseline Drift | 2 × 10⁻⁴ AU/hr |
| Detector | SSI Model 500 UV-Vis Variable Wavelength Detector |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SULF UV |
| Detection Target | Total Sulfur |
| Compliance Standards | ASTM D5453, AFNOR M-07-059, ISO 20846, SH/T 0689 |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SULFUVL |
| Pricing | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Super-Pig |
| Pricing | Upon Request |
| Key Features | Temperature Range: RT to 85°C (Operating Range: 50 ±10°C) |
|---|---|
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | RT → 85°C in ≤25 min |
| Light Source | Single 2.5 kW Air-Cooled Metal Halide Lamp |
| Spectral Output | 295–450 nm (UV–Visible) |
| Irradiance at Sample Plane | 200 ±8 W/m² |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| Compliance | Designed per ISO 4892-2, ASTM G154, IEC 60068-2-5, and GB/T 16422.2 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PLD-Workstation |
| Price Range | USD 650,000 – 13.5 million |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | SW-CJ-1B |
| Price | USD 850 (est.) |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Horizontal laminar flow |
| Average Air Velocity | 0.3–0.6 m/s (adjustable) |
| Vibration (Half-Peak) | ≤3 µm |
| Illumination | ≥300 lx |
| Power Supply | AC 200 V, 1Φ, 50 Hz |
| Max. Power Consumption | 0.4 kW |
| Net Weight | 110 kg |
| Work Area Dimensions (W×D×H) | 820 × 480 × 600 mm |
| Overall Dimensions (W×D×H) | 900 × 700 × 1450 mm |
| HEPA Filter Spec. | 820 × 600 × 50 mm, single unit |
| Lighting | 20 W fluorescent lamp (1×), optional UV lamp (20 W, 1×) |
| Surface Material | Imported stainless steel work surface |
| Differential Pressure Gauge | Integrated |
| Fan System | Variable-speed centrifugal blower with touch-control voltage regulation |
| Origin | Shanghai |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | SYD-2806H |
| Pricing | Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PM Series |
| Pricing | Upon Request |
| Measurement Principle | Extractive Nephelometry (Scattered Light Detection) |
| Measurable Parameters | Mass Concentration of Ambient and Flue Gas Particulate Matter (PM₁₀, PM₂.₅, TSP) |
| Detection Limit | 0.1 µg/m³ (as PM₁₀ equivalent) |
| Sampling Method | Heated Extractive Probe with Return-Line Conditioning |
| Optical Maintenance | Purge-Gas–Assisted Lens Cleaning |
| Calibration | In-Situ Auto-Zero and Span Calibration via Patented Reference Path Technology |
| Compliance | Designed to meet EN 15267-3, EN 14181 (QAL1/QAL2), and EPA Method 9/PS-11 requirements for continuous emission monitoring systems (CEMS) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PM-200 |
| Pricing | Upon Request |
| Measurement Principle | Beta-Ray Absorption with Complementary Optical Scattering |
| Measured Parameter | Total Suspended Particulate Mass Concentration (PM) |
| Detection Limit | 0.1 mg/m³ (100 µg/m³) |
| Compliance | Designed to meet EU Directive 75/76/EEC requirements and EPA Method 5 for isokinetic sampling |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MG-1300M-2A |
| Price Range | USD 14,000 – 70,000 (FOB) |
| Temperature Control Range & Accuracy | +5°C above ambient to +40°C, ±0.5°C uniformity in chamber, ±0.2°C in culture vessel (at +37°C, 5% CO₂, 25°C ambient) |
| Humidity Control | Not equipped |
| Capacity | Two 40-layer multilayer cell culture vessels (e.g., CellMASSter, Cell Factory, CellSTACK) |
| Heating Method | Quadruple-wall air-jacketed + inline gas stream heating |
| CO₂ Sensor | NDIR infrared (IR) type, control range 3.0–8.0%, resolution 0.1% |
| O₂ Sensor | Zirconia-based electrochemical sensor, display range 1–25% |
| Gas Flow | 2 L/min × 2 independent channels |
| Air Circulation | Horizontal laminar flow fan |
| Data Logging | Built-in Windows XP PC with 6.5" touchscreen, CSV/TXT export |
| Safety Features | Dual-stage overtemperature protection (electronic + liquid-expansion mechanical), controller fault alarm (audible), door-open interlock |
| Construction | Interior and exterior stainless steel (SUS304) |
| Dimensions (W×D×H) | 1280 × 950 × 1930 mm (excluding protrusions) |
| Standard Accessories | Two motorized rotating platforms for 40-layer vessels (incl. leveling mechanism and transport cart), one shelf for 10-layer vessels |
| Compliance | Designed for GLP-compliant bioprocess environments |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tankblot Eco-Maxi |
| Pricing | Upon Request |