| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tankblot Eco-Mini |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TC-HIIIDPK |
| Pricing | Available Upon Request |
| Measurement Principle | Integrating Sphere (60 mm diameter) |
| Compliance | JIS K 6718, JIS K 7105, ASTM D1003 |
| Light Source | Tungsten-Halogen Lamp |
| Detector | Silicon Photodiode |
| Measuring Aperture | Ø10 mm |
| Display | Backlit LCD |
| Output | Built-in Thermal Printer |
| Measured Parameters | Total Transmittance (Tt %), Diffuse Transmittance (Td %), Specular Transmittance (Tp %), Haze (%), Max/Min/Average Statistics |
| A/D Adjustment | User-configurable reference voltage calibration |
| Power Supply | Stabilized DC source for measurement integrity |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TC-HIIIDPK |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hybrigene HB-3D |
| Price | Upon Request |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A.B.C.D.E Temperature Indicating Strip |
| Pricing | Available Upon Request |
| Temperature Range | −30 °C to 260 °C |
| Accuracy | ±1 °C |
| Calibration Traceability | ISO/IEC 17025-accredited reference standards |
| Compliance | ISO 9001 certified manufacturing & quality control |
| Format | Adhesive-backed multi-point irreversible thermal indicator strip with 5 discrete temperature bands (A–E), each containing 8 calibrated temperature-sensitive elements |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | TFC-30 |
| Pricing | Upon Request |
| Flow Rate Options | 5–30 L/min, 3–30 L/min, 1–15 L/min, 5–25 L/min |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±1‰ |
| Maximum Negative Pressure | ≥15,000 Pa |
| Charging Current | 300 mA |
| Power Supply | 10 V DC / 220 V AC, 50 Hz |
| Operating Temperature | −25 to +45 °C |
| Noise Level | ≤60 dB(A) |
| Relative Humidity | ≤85% RH |
| Dimensions | 200 × 160 × 140 mm |
| Battery | Built-in Ni-MH rechargeable battery (fully charged voltage ≈12 V, runtime ≈4 h continuous) |
| Display | LCD with real-time countdown and flow indication |
| Control | Microprocessor-based timer with pause/resume function, programmable 00:00–99:59 (hh:mm) countdown |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Optical Microscope |
| Price Range | USD 92,000 – 132,000 |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temp. Uniformity | ±1.5°C |
| Temp. Stability | ±0.5°C |
| Humidity Uniformity | ±3% RH |
| Humidity Stability | ±2% RH |
| Heating Rate | ~3°C/min (avg.) |
| Cooling Rate | ~1°C/min (avg.) |
| Internal Dimensions | 50 × 60 × 50 cm (W×H×D) |
| External Dimensions | 102 × 147 × 108 cm (W×H×D) |
| Construction | SUS304 Stainless Steel Interior |
| Insulation | Rigid Polyurethane Foam + Glass Wool |
| Refrigeration System | Dual-Stage Cascade (R404A/R23) |
| Control System | TEMI Programmable PID+SSR Microprocessor Controller |
| Compressor Type | Hermetic or Semi-Hermetic (Imported OEM Units) |
| Critical Components | Sporlan Expansion Valves & Filters, Castel Solenoid Valves, Alco Oil Separators, Ranco Pressure Controls |
| Cooling Method | Air-Cooled or Water-Cooled (Optional for High-Capacity Units) |
| Defrost Mode | Automatic & Manual Cycles |
| Key | Temperature Range: -40 °C to +100 °C |
|---|---|
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±1 °C |
| Humidity Uniformity | ±5% RH |
| Ramp Rate (Heating) | ~4.0 °C/min |
| Ramp Rate (Cooling) | ~1.0 °C/min |
| Construction | Interior & Exterior – SUS304 Stainless Steel, Matte Finish |
| Insulation | High-Density Polyisocyanurate Foam (HFO-blown, Low-GWP) |
| Cooling System | Air-Cooled, Single-Stage Compressor (for -20 °C), Dual-Stage Compressor (for -40 °C to -70 °C) |
| Door Configuration | Dual-Facing Front & Rear Access Doors |
| Sample Mounting | LCD-Adjustable Tilt Fixture |
| Sensor Placement | Directly in Test Zone (Not in Air Duct) |
| Compliance Support | JEDEC JESD22-A104, MIL-STD-810H Method 503.5, IEC 60068-2-14, AEC-Q200, IPC-9701, IPC-J-STD-020 |
| Key Specifications | Temperature Range: -65°C to +180°C (typical) |
|---|---|
| Transfer Time | ≤15 s (dual-compartment), ≤30 s (three-zone) |
| Recovery Time | ≤5 min (standard load) |
| Internal Volume | 100–1000 L (configurable) |
| Cooling Method | Dual-stage cascade refrigeration with water-cooled condensers |
| Compliance | GB/T 2423.1–2, GB/T 2423.22, GJB 150.5, IEC 60068-2-14, MIL-STD-810H Method 503.5, ASTM D648, ISO 11359-2 |
| Power Supply | 380 VAC ±10%, 3-phase, 50/60 Hz |
| Water Cooling Requirement | External cooling tower (10 m³/h flow rate, 32°C max inlet temperature) |
| Control System | PID-based programmable controller with Ethernet interface |
| Data Logging | Built-in memory + optional USB/RS485 export |
| Safety Features | Over-temperature, over-pressure, compressor high/low pressure, phase failure, door interlock |
| Key | Temperature Range: -40 to 100°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ±1°C |
| Humidity Uniformity | ±5% RH |
| Door Configuration | Dual-front & rear access doors |
| Heating Load Capacity | Customizable per user specification |
| Cooling System | Air-cooled, single-stage compressor (for -20°C base) / dual-stage compressor (for -40°C to -70°C operation) |
| Ramp Rates | ~4.0°C/min (heating), ~1.0°C/min (cooling) |
| Construction | Interior and exterior walls in brushed SUS304 stainless steel |
| Viewing Window | Low-condensation coated electrothermal glass |
| Control System | PLC-based programmable controller with color touchscreen HMI |
| Compliance | Designed to support IEC 60068-2-14, MIL-STD-810H Method 503.5, JESD22-A104, and JEDEC J-STD-020 for lead-free solder process validation |
| Key | Temperature Range Options: -20°C to 150°C |
|---|---|
| Humidity Range (optional) | 20–98% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| Humidity Deviation | +2 / −3% RH |
| Heating Rate | 1.0–3.0°C/min |
| Cooling Rate | 0.7–1.0°C/min |
| Control System | Programmable Touchscreen Controller (English/Chinese UI) |
| Temperature Setpoint Accuracy | ±0.1°C |
| Humidity Setpoint Accuracy | ±1% RH |
| Sensor Type | PT100 Platinum Resistance Thermometer |
| Heating Method | Independent Nickel-Chromium Alloy Heaters |
| Humidification | Stainless Steel Surface Evaporation System |
| Dehumidification | Evaporator Coil Dew-Point Contact Method |
| Exterior Material | Cold-Rolled Carbon Steel with Phosphating & Electrostatic Powder Coating OR SUS304 Brushed Stainless Steel |
| Interior Material | SUS304 Mirror-Finish Stainless Steel |
| Insulation | Polyurethane Rigid Foam + Ultra-Fine Glass Fiber |
| Door Seal | Dual-Layer High/Low-Temperature Resistant Silicone Rubber |
| Power Supply | AC 380V ±10%, 50 ±0.5 Hz, 3-Phase 5-Wire |
| Refrigeration | Twin-Stage Cascade Air-Cooled System with Imported Hermetic Compressors (France) |
| Key Features | Two-zone (hot/cold chambers with basket transfer) or three-zone (hot chamber / cold chamber / test chamber) architecture |
|---|---|
| Temperature Range | Hot Zone up to +200 °C |
| Test Zone | −65 °C to +150 °C |
| Temperature Transition Time | ≤5 min (typical recovery) |
| Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration System | Dual-stage cascade refrigeration with imported semi-hermetic compressors (Germany) |
| Refrigerants | R404A / R23 (ozone-friendly) |
| Insulation | High-density fire-retardant PU foam |
| Interior | Mirror-finish SUS304 stainless steel |
| Exterior | SUS304 or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Cooling Water Requirement | External cooling tower (10 m³/h capacity required) |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–2002, GJB 150.5–86, IEC 60068-2-14, EIA-364-32, QC/T 17–92, SJ/T 10186–91 & 10187–91 |
| Customizable Internal Dimensions | 40×35×30 cm to 70×60×60 cm (W×H×D) |
| Key | Temperature Range Options: −70°C to +150°C |
|---|---|
| Humidity Range | 30–98% RH |
| Humidity Deviation | +2 to −3% RH |
| Temperature Fluctuation | ±0.5°C |
| Temperature Uniformity | ≤±2°C |
| Avg. Ramp Rate | 0.7–1.0°C/min |
| Timer Setting Range | 0–9999 h |
| Power Supply | AC 380 V |
| Internal Material | SUS304 Stainless Steel Mirror Finish |
| External Material | A3 Steel with Powder Coating |
| Observation Window | Embedded Heated Tempered Glass with LED Illumination |
| Test Port | Ø50 mm |
| Compliance | Designed to Support ASTM D5229, ISO 16750-4, IEC 60068-2-14, MIL-STD-810H Thermal Shock Protocols |
| Key | Temperature Range (Hot Zone): RT to +150 °C (unloaded) |
|---|---|
| Temperature Range (Cold Zone) | RT to −20 °C (unloaded) |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±3 °C |
| Ramp Rate (Heating) | ≤25 min (RT → +150 °C, average) |
| Ramp Rate (Cooling) | ≤15 min (RT → −20 °C, average) |
| Low-Temperature Limit | ≤−25 °C |
| Thermal Shock Transition Range | +150 °C ↔ −20 °C |
| Load Capacity | ≤30 kg |
| Temperature Recovery Time | ≤5 min |
| Basket Transfer Time | ≤15 s |
| Power Rating | 13–20 kW (model-dependent) |
| Refrigerant | HFC-based, dual-stage cascade cryogenic system |
| Key | Temperature Range: −70 °C to +150 °C |
|---|---|
| Humidity Range | 20–98% RH |
| Temp. Uniformity | ±1.5 °C |
| Humidity Uniformity | ±3% RH |
| Temp. Stability | ±0.5 °C |
| Humidity Stability | ±2% RH |
| Internal Dimensions (W×H×D) | 600 × 850 × 800 mm |
| External Dimensions (W×H×D) | 1200 × 1700 × 1300 mm |
| Construction | Interior – SUS#304 stainless steel (1 mm thick) |
| Insulation | Rigid polyurethane foam + fiberglass wool |
| Refrigeration System | Hermetic compressor (Tecumseh or equivalent), eco-friendly refrigerant (R404A/R507), air-cooled condenser, fin-tube evaporator, solenoid valve, dryer filter, capillary tube |
| Heating System | U-shaped finned tubular heaters |
| Control System | TEMI880 color touchscreen programmable controller (LCD, bilingual English/Chinese interface, multi-segment PID control, real-time curve display, alarm logging, data export via USB) |
| Power Supply | 3-phase 5-wire 380 VAC ±10% or 2-phase 3-wire 220 VAC ±10% |
| Standard Accessories | Dual-pane tempered glass observation window, φ50 mm test port (left side), two adjustable sample racks, interior fluorescent lighting, four casters with brakes, built-in humidifier tank |
| Safety Protections | Compressor overheat/overcurrent/high-pressure protection, heater dry-run prevention, chamber overtemperature alarm, low-water level detection |
| Key Features | Programmable 7-inch color touchscreen controller (Chinese UI) |
|---|---|
| Temperature Range | -30°C to +150°C / -50°C to +150°C / -65°C to +150°C |
| Temperature Uniformity | ±2.0°C |
| Temperature Stability | ±0.5°C |
| Heating Rate | up to 20°C/min (non-linear average) |
| Cooling Rates | 3 / 5 / 10 / 15°C/min (non-linear average) |
| Refrigeration System | Semi-hermetic or hermetic compressors (European/American origin) |
| Refrigerants | R404A, R23 |
| Insulation | High-density polyurethane foam or ultra-fine glass wool |
| Interior Material | SUS304/2B stainless steel with radius-corner design |
| Exterior Finish | Powder-coated cold-rolled steel |
| Safety Protections | Over-temperature, over-pressure, phase-loss, motor overload, earth leakage, compressor high-temp/overcurrent, grounding terminal |
| Compliance | GB/T 2423.1–1989, GB/T 2423.2–1989, GB/T 2423.34–1993, IEC 60068-2-30 |
| Key | Temperature Range: −70 °C to +150 °C |
|---|---|
| Heating Rate (−20 °C → +100 °C) | ≈35 min |
| Cooling Rate (20 °C → −70 °C) | ≈90 min |
| Inner Chamber Material | 1 mm SUS#304 Stainless Steel |
| Outer Chamber Material | Powder-Coated Cold-Rolled Steel or SUS#304 Brushed Stainless Steel |
| Insulation | Rigid Polyurethane Foam + Glass Wool |
| Refrigeration System | Hermetic Compressor (Tecumseh/France) with Eco-Friendly Refrigerant (R404A/R507) |
| Controller | TEMI880 Color Touchscreen Programmable Temperature/Humidity Controller (LCD, Bilingual English/Chinese Interface, Multi-PID, Curve Monitoring, Alarm Logging) |
| Power Supply | 3φ5W 380 VAC ±10% or 2φ3W 220 VAC ±10% |
| Standard Accessories | Double-Layer Tempered Glass Viewing Window, φ50 mm Cable Port (Left Side), Two Adjustable Sample Racks, Fluorescent Interior Lamp, Four Casters, Integrated Humidifier Tank |
| Safety Protections | Compressor Overheat/Overcurrent/High-Pressure Protection, Dry-Run Prevention for Heaters & Humidifiers, Chamber Over-Temperature Cut-off, Low-Water-Level Alarm |
| Compliance | Designed per IEC 60068-2-14 (Environmental Testing – Part 2-14: Tests – Test N: Change of Temperature) and ASTM D5229/D5229M (Standard Test Method for Moisture Absorption Properties of Polymer Matrix Composite Materials) — Structural and operational architecture supports GLP/GMP-aligned validation protocols. |
| Key Features | Three-zone design (high-temp chamber, low-temp chamber, test chamber) |
|---|---|
| Inner chamber wall thickness | 1.0–1.2 mm standard |
| Standard internal volumes | 50 L to 1000 L |
| Typical temperature ranges | −40 °C to +150 °C, −55 °C to +150 °C, or −70 °C to +150 °C |
| Key | Temperature Range (High Zone): +150°C to +200°C |
|---|---|
| Temperature Range (Low Zone) | -70°C to -40°C |
| Transition Time (Typical) | ≤15 s (5℃ to -40℃) |
| Test Zone Stability | ±0.5°C |
| Control System | PLC-based with 302×240-dot LCD HMI (Bilingual English/Chinese) |
| Program Storage | 100 user-defined profiles, up to 9999 cycles per profile |
| Timing Resolution | 1 min (adjustable to 1 sec) |
| Communication Interface | RS-232C, optional RS-485/Ethernet |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–1989, GJB 150.5–1986, GJB 360.7–1987, IEC 60068-2-14 (Test N) |
| Key Temperature Range Options | A: -20°C to 200°C |
|---|---|
| B | -40°C to 200°C |
| C | -60°C to 200°C |
| Temperature Stability | ≤ ±2°C in High/Low Temp Zones |
| Thermal Transition Performance | -40°C ↔ 85°C in ≤ 11 min (including dwell) |
| Heat Storage Zone Ramp | Ambient to +100°C in ~30 min |
| Cold Storage Zone Ramp | Ambient to -50°C in ~90 min |
| Test Zone Dimensions | 450 mm (W) × 300 mm (H) × 300 mm (D) |
| Test Load Capacity | 20 kg / 30 kg / 50 kg options |
| Construction | Interior & Exterior Panels – SUS#304 Stainless Steel |
| Insulation | High-Density Fire-Retardant PU Foam + Advanced K-Type Sweat-Prevention Ducting |
| Cooling System | Dual-Stage Cryogenic Refrigeration with Eco-Friendly Refrigerant (R-404A/R-23 blend), Plate-Type Heat Exchangers, Automatic/Manual Defrost Circuits |
| Control System | 7-inch Full-Color LCD Touchscreen Microprocessor Controller with RS-232/RS-485 Interface |
| Compliance | Designed to meet IEC 60068-2-14, MIL-STD-810H Method 503.5, JIS C 0025, CNS 12227, and ISO 16750-4 environmental stress screening requirements |
| Safety Protections | Independent Over-Temperature Cutout (Test Chamber), Compressor High-Pressure & Low-Oil-Pressure Protection, Heating Element Overload/Short-Circuit Protection, Phase Failure & Undervoltage Detection, Ground Fault Monitoring |
| Key | Internal Chamber Dimensions: 46×46×46 cm |
|---|---|
| High-Temperature Zone Range | Ambient to +150 °C |
| Low-Temperature Zone Range | Ambient to −60 °C |
| Average Ramp Rate | 1.5 °C/min |
| Temperature Uniformity | ±0.5 °C |
| Temperature Accuracy | ±2 °C |
| Transfer Time (Cold ↔ Hot) | <10 s |
| Temperature Recovery Time | <5 min |
| Actuation Method | Pneumatic Cylinder-Based Basket/Tray Transfer |
| Construction | Exterior & Interior Liner — SUS304 Stainless Steel |
| Refrigeration System | Dual-Stage Compound Compressor (Air-Cooled or Water-Cooled), Imported Tecumseh (France) Compressor Units, Eco-Friendly Refrigerant (R404A/R507) |
| Control System | Programmable LCD Controller (320 × 240 Dots), Bilingual (English/Chinese) Interface |
| Max. Program Storage | 100 Sets |
| Max. Cycles per Program | 9999 |
| Max. Segment Duration | 999 h 59 min |
| Communication | RS-232C Port for PC Integration, Data Logging & Remote Editing |
| Dynamic I/O | Two Time-Signal Relays |
| Power Rating | 7.5 kW / 12 kW / 15 kW / 26 kW |
| Electrical Supply | AC 380 V, 50 Hz, 3-Phase 4-Wire |
| Compliance | GB/T 2423.22, GJB 150.5A, IEC 60068-2-14, MIL-STD-810H Method 503.5 |
| Application Scope | Static (non-moving) specimen testing only |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Accela |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Operating Pressure | 1250 bar (18,130 psi) |
| Flow Rate Range | 0.001–2.000 mL/min |
| Gradient Delay Volume | ≤70 µL |
| Flow Accuracy | ≤±0.5% |
| Gradient Accuracy | ≤±0.5% |
| Pressure Ripple | <0.5 bar (peak-to-peak) |
| Typical Peak Width (FWHM) | <1 s |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM-1020 |
| Measurement Method | Beta Ray Attenuation |
| Measured Parameters | PM10 / PM2.5 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC IsoLink II |
| Quotation | Upon Request |
| Measurement Precision | δ¹³C < 0.2‰, δ¹⁵N < 0.5‰, δ¹⁸O < 0.8‰, δ²H < 3.0‰ |
| Measured Isotopes | ¹³C, ¹⁵N, ¹⁸O, ²H |
| Mass Range | 1–80 u |
| Resolution | 110 (10% valley) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LTQ Orbitrap |
| Price Range | USD 135,000 – 270,000 (FOB) |
| Instrument Type | Quadrupole-Orbitrap Hybrid |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LTQ-FT Ultra |
| Price Range | USD 140,000 – 280,000 |
| Instrument Type | Hybrid Tandem Mass Spectrometer (LTQ + FTICR) |