| Key | Platform Dimensions (mm): 250×250 |
|---|---|
| Payload Capacity (kg) | 50 |
| Max Acceleration | 650 g |
| Max Stroke | 1800 mm |
| Max Slew Rate | 7.4 m/s² (HS) |
| Minimum Shock Duration (ms) | 1, 2, 3 / 2 (Optional) |
| Air Pressure Requirement | 6–8 kg/cm² |
| Frequency Range (Programmable) | 1–400 Hz |
| Frequency Resolution | 0.01 Hz |
| Frequency Accuracy | ±0.1 Hz |
| Vibration Waveform | Sinusoidal |
| Max Displacement (p-p) | 0–5 mm |
| Programmable Segments | 15 segments per profile, each with independent frequency/time settings |
| Control Mode | Sweep, Fixed Frequency, Random (optional), Time-Controlled |
| Power Supply | 220 V ±20%, 5 A |
| Motor Power | 2.2 kW |
| Compliance | Designed for ASTM D999, ISO 13373-1, IEC 60068-2-6, IEC 60068-2-64, MIL-STD-810H Method 514.8 |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range | 5–98% RH (standard: 20–98% RH) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.5% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ~4.0°C/min |
| Cooling Rate | ~1.0°C/min |
| Construction | Interior & Exterior SUS304 Stainless Steel |
| Insulation | High-Density Polyurethane Foam with Ethyl Chloroformate Base |
| Cooling System | Air-Cooled, Single-Stage (to -20°C) or Twin-Stage Compressor (to -70°C) |
| Safety Protections | Fuseless Circuit Breaker, Compressor Overload Protection, Refrigerant HP/LP Cut-off, Over-Temp/Over-Humidity Interlocks |
| Controller | Color LCD Touchscreen with Programmable Temp/Humidity Profiles, RS-232 Interface |
| Vibration Integration | Designed for External Electrodynamic or Hydraulic Shaker Table Coupling (User-Specified) |
| Key | Temperature Range: -40°C to +100°C |
|---|---|
| Humidity Range | 30–98% RH |
| Temp. Uniformity | ≤±2°C |
| Temp. Fluctuation | ±0.5°C |
| Humidity Deviation | +2 to −3% RH |
| Ramp Rate | 0.5–1.2°C/min |
| Chamber Models | OK-ZTH-408 (60×85×80 cm), OK-ZTH-800 (100×100×80 cm), OK-ZTH-1000 (100×100×100 cm) |
| Safety Protections | Overload, Ground Fault, Overtemperature, Compressor High-Pressure, Motor Overload, Auto Power Cut-off with Audible Alert |
| Compliance | Designed per IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, ISO 16750-4, MIL-STD-810H (Temperature & Humidity Sections), and ASTM D4332 |
| Temperature Range | -20 °C to 130 °C |
|---|---|
| Humidity Range | 40–98 % RH |
| Temperature Uniformity | ±2 °C (unloaded) |
| Temperature Fluctuation | ±0.5 °C (unloaded) |
| Humidity Fluctuation | ±2 % RH |
| Heating Rate | -20 °C to 120 °C ≤ 60 min |
| Cooling Rate | Ambient to -20 °C ≤ 45 min (unloaded) |
| Vibration Force (Sine) | 2.94 kN (300 kgf) |
| Frequency Range | 5–2000 Hz |
| Max Acceleration | 980 m/s² (100 g) |
| Max Velocity | 1.1 m/s |
| Max Displacement | 25 mm p-p |
| Moving Mass | 2.7 kg |
| Payload Capacity | 120 kg |
| Table Diameter | 150 mm |
| Vibration Axis | Vertical (Z-axis) |
| Time Setting Range | 0–999 h |
| Compliance | GB/T 2423.1, GB/T 2423.3, GB/T 2423.4, IEC 60068-2-1, IEC 60068-2-3, IEC 60068-2-30 |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range | 5–98% RH (standard: 20–98% RH) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.5% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ~4.0°C/min |
| Cooling Rate | ~1.0°C/min |
| Chamber Interior/Exterior Material | SUS304 Stainless Steel |
| Insulation | High-Density Polyurethane Foam with Closed-Cell Structure |
| Cooling Method | Air-Cooled, Single-Stage or Two-Stage Refrigeration System (selected per low-temp requirement) |
| Safety Protections | Overcurrent Protection, Compressor Overload Protection, Refrigerant HP/LP Cut-off, Over-Temp/Over-Humidity Interlock |
| Controller | Full-Color LCD Touchscreen with Programmable Ramp-Soak Profiles & RS-232 Interface |
| Vibration Integration | Modular Interface for External Electrodynamic or Hydraulic Shaker Systems (user-specified model) |
| Key Features | Sinusoidal vibration |
|---|---|
| Frequency range | 1–200 Hz |
| Max acceleration | 10 g (peak) |
| Max displacement | 0–5 mm p-p |
| Test table size | 450 × 450 × 46 mm |
| Payload capacity | 40 kg |
| Power supply | 220 V ±10%, 2.2 kW |
| Frequency resolution | ±1 Hz |
| Compliance | ASTM D999, ISO 8767, ISTA 3A/3E, GB/T 4857.7, GB/T 4857.10 |
| Key | Temperature Range: -70 °C to +200 °C |
|---|---|
| Humidity Range | 30–98% RH |
| Climate Chamber Volume | 225–800 L |
| Vibration Force | 980 N to 49 kN |
| Frequency Range | 2–2500 Hz |
| Max Acceleration | 100 g (980 m/s²) |
| Max Displacement | 25 mm (pk-pk) |
| Max Velocity | 1.5 m/s |
| Moving Mass | 6 kg |
| Payload Capacity | 190 kg |
| Distortion | <5% THD |
| Residual Magnetic Field | <10 Gauss (at 10 cm from armature) |
| Dimensions (L×W×H) | 800×600×710 mm |
| Weight | 700 kg |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.3, GJB 150.3, GJB 150.4, IEC 60068-2-3 (Test Ca), IEC 60068-2-30 |
| Temperature Range | -20 °C to +130 °C |
|---|---|
| Humidity Range | 40–98% RH |
| Temperature Uniformity | ±2 °C (unloaded) |
| Temperature Fluctuation | ±0.5 °C (unloaded) |
| Temperature Deviation | ≤±2 °C |
| Humidity Fluctuation | ±2% RH |
| Humidity Deviation | ≤±2% RH |
| Heating Rate | -20 °C to +120 °C ≤ 60 min (unloaded) |
| Cooling Rate | Ambient to -20 °C ≤ 45 min (unloaded) |
| Vibration Mode | Sinusoidal |
| Frequency Range | 5–2000 Hz |
| Max. Acceleration | 980 m/s² (100 g) |
| Max. Velocity | 1.1 m/s |
| Max. Displacement | 25 mm p-p |
| Force Capacity | 2.94 kN (300 kgf) |
| Effective Moving Mass | 2.7 kg |
| Max. Payload | 120 kg |
| Table Diameter | 150 mm |
| Vibration Axis | Vertical (Z-axis) |
| Test Duration Setting | 0–999 hours |
| Power Efficiency | 60% reduction vs. conventional controllers |
| Key | Temperature Range: −40 °C to +150 °C (optional down to −120 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temp. Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temp. Uniformity | ±0.5 °C |
| Temp. Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen controller |
| Internal Material | SUS304 stainless steel |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (220 V optional) |
| Compliance | GB10589, GB10592, GB11158, GB/T5170.2, GB/T5170.5, GB2423.1/2/22, GB2424.1 |
| Brand Coverage | Shimadzu and all major OEMs |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Types | Analytical Instruments (GC, HPLC, LC-MS, GC-MS, UV-Vis, FTIR, ICP-OES, AAS) |
| Response Time | Within 24 Hours |
| Service Scope | Installation, Preventive Maintenance, Calibration, Troubleshooting, Component Replacement, and Performance Verification |
| Certification | CNAS Accredited (ISO/IEC 17020), IAF Recognized |
| Compliance | GB/T 27922–2011 Five-Star Certified |
| Service Fee Range | USD 700–1,400 per visit (quoted case-by-case) |
| Field Experience | 30 Years |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | JJ-20 |
| Pricing | Available Upon Request |
| Max Impact Energy | 4 J (Simply Supported Beam), 5.5 J (Cantilever Beam) |
| Sampling Rate | 1.2 µs |
| A/D Resolution | 1/65536 |
| Load Range Selection | ×1, ×2, ×4, ×8 |
| Load Measurement Accuracy | ≤1% FS |
| Simply Supported Beam Span Options | 40, 60, 62, 70, 95 mm |
| Standard Specimen Dimensions (Simply Supported) | 4×6×50 mm, 4×10×80 mm, 10×15×120 mm, 13×13×120 mm |
| Cantilever Beam Specimen Dimensions | 4×10×80 mm, (3.2–12.7)×12.7×63.5 mm |
| Pendulum Impact Velocity | 2.9 m/s (0.5–4 J range), 3.50 m/s (Cantilever mode) |
| Compliance | GB/T 1043–1993, GB/T 1843–1996 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CT-3100 |
| Pricing | Available Upon Request |
| Sample Size | 10 mg–20 g |
| Resolution | 1 ppm (1 µg) |
| Moisture/Solids Range | 10 ppm (10 µg) to 100% |
| Heating Temperature Range | 25–275 °C |
| Stored Test Methods | 8 pre-programmed protocols |
| Compliance | ASTM D7191-05 |
| Key | Origin: Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | SYD |
| Pricing | Available Upon Request |
| Max Load Options | 30 kN, 50 kN, 100 kN, 200 kN, 300 kN |
| Relative Indication Error | ±1% |
| Hydraulic Pump Rated Pressure | 25 MPa |
| Flexural Roller Diameter | 30 mm |
| Max Spacing Between Lower Rollers | 450 mm |
| Center Distance Between Upper Rollers | 150 mm |
| Center Distance Between Lower Rollers | 450 mm |
| Support Plate Length | 155 mm |
| Max Clearance Between Compression Platens | 230 mm |
| Piston Diameter × Stroke | 125 mm × 80 mm |
| Piston Stroke | 120 mm |
| Motor Power | 0.75 kW |
| Overall Dimensions (L×W×H) | 850 × 600 × 1340 mm |
| Compliance | GB/T 3722 |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CONGOTECH |
| Pricing | Upon Request |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Continent 512R Plus |
| Pricing | Available Upon Request |
| Max Speed | 12,000 rpm (fixed-angle rotor) / 4,500 rpm (swing-bucket rotor) |
| Max RCF | 20,929 ×g (fixed-angle) / 5,096 ×g (swing-bucket) |
| Max Capacity | 6 × 1000 mL (fixed-angle) / 6 × 750 mL (swing-bucket) |
| Cooling Method | Air-cooled refrigeration system |
| Timer Range | 0–99 h 59 min 59 s |
| Programmable Steps | 9-step ramp/brake profiling |
| Stored Protocols | 100 user-defined programs |
| Display Interface | Real-time RPM, RCF, time, and active program status |
| Motor Type | Brushless AC motor (1.7 kW output) |
| Power Supply | 220 V, 60 Hz, 0.8 kW (standby), 1.7 kW (peak) |
| Dimensions (W×D×H) | 640 × 630 × 840 mm |
| Net Weight | 230 kg |
| Rotor Recognition | Automatic identification via embedded RFID or mechanical coding |
| Safety Features | Imbalance detection, lid interlock, overspeed protection, motor fault monitoring, password-protected access control |
| Rotor Radius Calibration | User-configurable radius input for precise RCF calculation |
| Ramp/Brake Control | 9-stage acceleration/deceleration profile programming |
| Runtime Parameter Adjustment | Time modification during active run |
| RPM/RCF Cross-Conversion | On-the-fly unit switching with automatic recalculations |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LDS |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 645 |
| Temperature Range (Dark) | 0–40°C |
| Temperature Range (Light, 650 µmol·m⁻²·s⁻¹) | 10–40°C |
| Humidity Control Range | 40–90% RH |
| Illumination Max | 650 µmol·m⁻²·s⁻¹ (at 900 mm above shelf) |
| Internal Dimensions (W×D×H) | 1800 × 900 × 1500 mm |
| Effective Volume | 2500 L |
| Temp Uniformity | ±2.5°C |
| Temp Stability | ±0.1°C |
| Temp Repeatability | ±0.5°C |
| Temp Fluctuation | ±1.0°C |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Cordouan Arago ∞ |
| Quotation | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model Series | Arago ε, Arago ω, Arago ∞ |
| Product Type | Benchtop Refractometer |
| Temperature Control | Peltier-regulated (15–65 °C for ε |
| Digital Display | Yes (high-resolution capacitive touchscreen + PC interface) |
| Refractive Index Range (nD) | 1.25–1.51 or 1.51–1.75 (ε) |
| Resolution (nD) | ±0.00001 (ε, ω), ±0.000001 (∞) |
| Accuracy (nD) | ±0.0001 (ε), ±0.00005 (ω), ±0.00001 (∞) |
| Wavelength | 635 nm (ε), 658 nm (ω, ∞) |
| Prism Material | BK7 glass (ε), fused silica (ω), sapphire (∞) |
| Sample Cell Material | 316 stainless steel or Inconel® alloy (optional) |
| Brix Range | 0–95 % w/w |
| Brix Accuracy | ±0.002 % |
| Repeatability | ±0.01 % |
| Light Source | Integrated temperature-stabilized laser diode |
| Dimensions (W×D×H) | 10 × 24 × 27 cm |
| Weight | 8 kg |
| Interface | USB 2.0 (bidirectional PC communication) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Arago ε |
| Quotation | Upon Request |
| Measurement Principle | Critical Angle Determination via Total Internal Reflection |
| Measuring Range (nD) | 1.25–1.51 or 1.51–1.75 |
| Resolution (nD) | ±0.00001 |
| Accuracy (nD) | ±0.0001 |
| Temperature Control | Peltier-Regulated, Ambient to 65 °C |
| Prism Material | BK7 Optical Glass |
| Wavelength | 635 nm |
| Light Source | Stabilized Laser Diode with Integrated Peltier Thermal Management |
| Sample Cell Material Options | 316 Stainless Steel or Inconel Alloy |
| Interface | USB (Bidirectional PC Communication) |
| Power Supply | 100–240 V AC, 50/60 Hz, 10–50 W |
| Dimensions | 10 × 24 × 27 cm |
| Weight | 8 kg |
| Software Language | English or French |
| Compliance | Designed for GLP/GMP environments |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Arago ε / Arago ω / Arago ∞ |
| Price | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VASCO |
| Price Range | USD 26,000–39,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <5% |
| Measurement Time | 30 seconds |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cordouan-Arago ε Refractometer |
| Quotation | Upon Request |
| Measurement Principle | Critical Angle Refraction at Prism-Sample Interface |
| Measuring Range (nD) | 1.25–1.51 or 1.51–1.75 |
| Resolution (nD) | ±0.00001 |
| Accuracy (nD) | ±0.0001 |
| Temperature Control | Peltier-Regulated, Ambient to 65 °C |
| Prism Material | BK7 Optical Glass |
| Wavelength | 635 nm |
| Light Source | Stabilized Laser Diode with Integrated Peltier Thermal Management |
| Sample Cell Material Options | 316 Stainless Steel or Inconel® Alloy |
| Interface | USB 2.0 (Bidirectional PC Communication) |
| Power Supply | 100–240 V AC, 50/60 Hz, 10–50 W |
| Dimensions (L×W×H) | 10 × 24 × 27 cm |
| Weight | 8 kg |
| Display & Control | Touchscreen Interface or PC-Based Software (English/French) |
| Brix Range | 0–95 % w/w, Uncertainty: ±0.002 %, Repeatability & Accuracy: ±0.01 % |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Cordouan-Arago ω Refractometer |
| Quotation | Upon Request |
| Measurement Principle | Critical Angle Determination via Total Internal Reflection at Prism-Sample Interface |
| Measuring Range (nD) | 1.20–3.10 |
| Resolution (nD) | ±0.000001 |
| Accuracy (nD) | ±0.00001 |
| Temperature Control | Peltier-Regulated, 15–80 °C |
| Prism Material | Sapphire |
| Wavelength | 658 nm (Stabilized Laser Diode) |
| Sample Cell Options | 316 Stainless Steel or Inconel Alloy |
| Interface | USB 2.0 (Bidirectional PC Communication) |
| Power Supply | 100–240 V AC, 50/60 Hz, 10–50 W |
| Dimensions | 10 × 24 × 27 cm |
| Weight | 8 kg |
| Display & Control | Integrated Touchscreen or PC Software (English/French GUI) |
| Brix Range | 0–95 %, Brix Accuracy: ±0.002 %, Repeatability: ±0.01 % |
| Safety | Automatic Laser Shutoff, Integrated Sample Chamber Shield |
| Compliance | Designed for GLP/GMP environments |