Generic
Filter
Showing 871–900 of 1032 results
| Key | Temperature Range: -60°C to 100°C (selectable variants: -35°C/–20°C to 100°C) |
|---|---|
| Humidity Range | 15–95% RH (standard: 20–95% RH) |
| Temperature Stability | ±0.5°C |
| Humidity Stability | ±2% RH |
| Temperature Uniformity | ±2°C |
| Humidity Uniformity | ±3% RH |
| Temp/Humidity Deviation | ≤±2°C / ±3% RH |
| Refrigerant | R404A & R23 (zero-ozone-depletion HFC blend) |
| Construction | Modular PU-insulated walk-in panels (inner: SUS304 stainless steel |
| outer | color-coated steel) |
| Air Distribution | Ceiling-mounted low-velocity laminar airflow system |
| Control System | Large LED multifunctional controller with expandable I/O |
| Compliance | GB/T 5170.2–1996, GB/T 2423.2–2008 (IEC 60068-2-2), GJB 150.3–2009, GJB 150.4–2009, GJB 360.8–1987 |
| Safety | Overcurrent protection, compressor overheat/overpressure cutoff, dry-heater/steam-generator burnout prevention, low-water alarm, explosion-proof interior lighting, power-fail memory retention |
| Power Supply | AC 3φ 5W 380 V / 50 Hz |
| Optional | Data logging interface, RS485/RS232 or Ethernet connectivity for remote monitoring |
| Key | Temperature Range: 0°C to 100°C |
|---|---|
| Humidity Range | 30–98% RH |
| Temperature Uniformity | ±0.1°C |
| Humidity Uniformity | ±1% RH |
| Chamber Volume | 2 m³ to 300 m³ |
| Power Supply | AC 380 V (±10%), 50 Hz, 3-phase 5-wire |
| Total Power Consumption | 12 kW |
| Ambient Operating Conditions | 5°C–28°C (24-hr avg ≤28°C), RH ≤85% |
| Compliance | GB/T 10592–2008, GB/T 10586–2012, GB/T 2423.1–2022, GB/T 2423.2–2022, GB/T 2423.3–2016, GB/T 2423.4–2016 |
| Key | Cooling Method: Water-cooled |
|---|---|
| Light Source | Full-spectrum xenon arc lamp |
| Radiation Range | 300–800 nm (550 W/m² ±10%) / 300–1200 nm (1000 W/m² ±10%) |
| Black Panel Temperature Range | 40–85°C |
| Chamber Temperature Range | 0–150°C |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Lifetime | ~1500 h |
| Construction | Interior: SUS304 stainless steel |
| Exterior | SUS34 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Compliance Standards | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, GB/T 14576, ASTM D529, GB/T 15102-2006, GB/T 15104-2006 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FH100DX |
| Flow Rate | 14–4000 mL/min |
| Speed Range | 4–400 RPM |
| Reversible | Yes |
| Flow Accuracy | ±0.25% (with calibrated flow system) |
| Speed Resolution | 0.1 RPM |
| Speed Regulation Accuracy | ±0.25% of full scale |
| Control Inputs | 0–20 mA, 4–20 mA, or 0–10 V analog |
| Control Outputs | 4–20 mA or 0–10 V analog |
| Motor | 1/10 HP (75 W), PMDC, phase-controlled |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −25–65 °C |
| Enclosure Material | ABS housing |
| pump head options | glass-filled nylon, Delrin®, stainless steel, cold-rolled steel, nitrile rubber, polycarbonate |
| IP Rating | IP31 |
| Certifications | ETL, cETL, CE, RoHS |
| Dimensions (L×W×H) | 31.7 × 27.9 × 15.2 cm (12.5 × 11 × 6 in) |
| Net Weight | 7 kg (15 lbs) |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | WD-A |
| Pricing | Upon Request |
| Temperature Range | 6–70 °C (±2 °C accuracy) |
| Humidity Range | 10–95 %RH (±4 %RH accuracy) |
| Illuminance Range | 0–7000 lx (adjustable, natural light reference included) |
| Chamber Dimensions | 510 × 400 × 380 mm (dual-tier stainless steel interior with removable partitions) |
| Construction | AISI 304 stainless steel chamber and shelves |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WDDG |
| Pricing | Available Upon Request |
| Power Supply | 220 V AC, ~50 W |
| Carrier Gas | High-Purity Nitrogen, 5–10 L/h at ~0.5 bar inlet pressure |
| Measurement Range | 0–10 g/m²·day |
| Output | Direct digital readout across full scale (2.5-digit resolution) |
| Connected Meter | Triple-range analog meter (0–0.1 / 0–1.0 / 0–10 g/m²·day), 100 mV full-scale output |
| Accuracy | ±2% of reading or ±0.005 g/m²·day (whichever is greater) |
| Test Duration | 1–3 hours (sample-dependent) |
| Sample Diameter | 108 mm |
| Temperature Range | –20 °C to +60 °C |
| RH Gradient Generation | Compliant with DIN 53122 Part 2 |
| Dimensions (W×D×H) | 45 × 33 × 45 cm |
| Weight | 23 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WITec Alpha 300R |
| Price | €500,000 |
| Instrument Type | Confocal Raman Microspectrometer |
| Spectral Range | 300–1100 nm |
| Spectral Resolution | 1 cm⁻¹ |
| Spatial Resolution | Lateral 0.3 µm, Axial 0.8 µm (at 532 nm) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ±0.02 cm⁻¹ |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | WKW-300 |
| Quotation | Upon Request |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.5 °C |
| Heating Rates | 5 ±0.5 °C/6 min (Method A), 12 ±1.0 °C/6 min (Method B) |
| HDT Deformation Range | 0–0.5 mm |
| VST Penetration Range | 0–1 mm |
| Dial Indicator Resolution | ±0.005 mm |
| Max HDT Load | 5 kgf |
| Max VST Loads | GA = 10 N ±0.2 N, GB = 50 N ±1 N |
| Max Heating Power | ≤4000 W |
| Power Supply | 220 V, 50 Hz, 30 A |
| Cooling Modes | Natural convection & water cooling |
| Over-Temperature Protection | Configurable upper limit |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nanoliter2000 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WQ-FDO |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WQ401 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | WQF-520 |
| Pricing | Available Upon Request |
| Origin | Jilin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WSB-16 |
| Pricing | Available Upon Request |
| Max. Test Pressure | 0–16 MPa |
| Max. Specimen OD | ≤110 mm |
| Pressure Accuracy | ≤±1% FS |
| Constant-Pressure Control Band | –1% to +2% of setpoint |
| Temperature Range | Ambient to 95 °C |
| Temp. Uniformity & Stability | ≤±1 °C |
| Pressure Sampling Interval | 0.3 s |
| Test Duration Range | 1 s – 9999 h |
| Concurrent Test Channels | 3 independent circuits |
| Power Supply | 3-phase AC 380 V, 50 Hz |
| Control Cabinet Dimensions | 650 × 600 × 1800 mm |
| Heating Medium | Stainless Steel Water Bath with External Circulation System |
| Compliance | GB/T 6111–2003, GB/T 15560–1995, ISO 1167-1:2014, ASTM D1598, EN ISO 1167-2:2014 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WSSL-10 |
| Pricing | Available Upon Request |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Cond 3310 |
| Portability | Handheld |
| Conductivity Range | 0–1000 µS/cm (extendable to 1000 mS/cm) |
| TDS Range | 0–2000 mg/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–20 ppm |
| Temperature Range | 0–60 °C |
| Accuracy | ±0.05 % of full scale |
| Minimum Resolution | 0.001 µS/cm |
| Calibration | 1–5 point, auto-recognition of 16 DIN/NIST buffer standards |
| Protection Rating | IP66/IP67 |
| Data Storage | 5000 automatic / 200 manual entries |
| Battery Life | Up to 1000 h (50 h with backlight on) |
| Interface | Waterproof USB |
| Auto-Temperature Compensation (ATC) | Yes |
| Electrode Status Indication | Yes |
| CMC (Continuous Measurement Control) | Yes |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop |
| Model | inoLab pH 7310 |
| Measurement Parameters | Single (pH) |
| pH Range | –2.0 to 20.0 |
| Resolution | 0.1 / 0.01 / 0.005 pH (selectable) |
| Accuracy | ±0.005 pH (at 25 °C, calibrated with traceable buffers) |
| mV Range | ±1200.0 mV (±0.3 mV), ±2500 mV (±1 mV) |
| Temperature Range | –5.0 to +105.0 °C (±0.1 °C) |
| Calibration | Up to 5-point, DIN/NIST/WTW TEC buffer support (20 pre-programmed standards) |
| Memory Capacity | 500 manual entries / 5000 automatic logs |
| Data Output | USB 2.0 micro-B interface, CSV format |
| Compliance | GLP-compliant data logging with timestamp, operator ID, electrode serial number, and calibration history |
| Optional | Integrated thermal printer (58 mm width) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | IQ Sensor Net |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | pH, ORP, Temperature, Dissolved Oxygen (DO), Conductivity, Turbidity, Total Suspended Solids (TSS), Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Salinity, Ammonium-N (NH₄⁺-N), Nitrate-N (NO₃⁻-N), Nitrite-N (NO₂⁻-N), Total Organic Carbon (TOC), Spectral Absorption Coefficient (SAC), Phosphate (PO₄³⁻) |
| Enclosure Rating | Transmitter IP66 / Sensors IP68 |
| Communication | RS-485/232, MODBUS RTU, PROFIBUS DP |
| Analog Outputs | ≥6 × 4–20 mA |
| Relay Outputs | ≥6 |
| Digital Signal Transmission Distance | Up to 1000 m over 2-wire shielded cable |
| Power Supply | 24 VDC via signal cable |
| Sensor Auto-Recognition | Yes |
| Max. Connected Sensors | 20 |
| Cleaning Technology | Integrated ultrasonic cleaning (turbidity/TSS sensors) |
| Measurement Principle | Potentiometric (pH/ORP), Optical luminescence (DO), 4-electrode conductivity, 90° scattered light turbidimetry (FNU), UV-VIS absorbance (COD/SAC/NO₃⁻/NH₄⁺/PO₄³⁻), respirometric (BOD), catalytic oxidation (TOC) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Pressure Differential (O₂ Consumption + CO₂ Absorption) |
| Measurement Range | 0–5000 mg/L |
| Detection Limit | 500 mg/L |
| Accuracy | ±1 mg/L |
| Single Sample Measurement Time | 8 min |
| Repeatability | ±3% |
| Compliance | DIN EN 1899-1, DIN EN 1899-2, EPA Method 5210B, GLP/GMP-ready |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measured Parameters | pH, mV, ISE (Ion-Selective Electrode), Temperature |
| Calibration Options | 2–7 point ISE calibration, non-linear ISE applications |
| Display | Backlit LCD |
| Enclosure Rating | IP67 |
| Power Supply | 4 × AA alkaline or 4 × NiMH rechargeable batteries |
| Data Storage | Manual (200 entries) or automatic (5,000 entries), configurable logging interval |
| Compliance | GLP-compliant data handling, audit-ready timestamped records |
| Connectivity | Waterproof USB interface |
| CMC (Continuous Measurement Control) | Real-time calibration and measurement integrity monitoring |
| Operating Temperature Range | –5.0 to +105.0 °C (±0.1 °C accuracy) |
| pH Range | –2.000 to +19.999 (±0.005 pH accuracy) |
| mV Range | –2500 to +2500 mV (±1 mV accuracy) |
| ISE Range | 0.000–9.999 / 10.00–99.99 / 100.0–999.9 / 1000–999999 (unit-dependent |
| Origin | Imported |
|---|---|
| Type | Benchtop Laboratory Analyzer |
| Model | PhotoLab® S6, PhotoLab® S12, photoLab® 6000 Series |
| Measurement Principle | Rapid Digestion Photometry |
| Wavelength Range | 436 nm, 525 nm, 580 nm, 610 nm, 690 nm (S6) |
| Measurement Range | 0–1000 mg/L COD |
| Accuracy | ±5% of reading |
| Repeatability | ≤5% RSD |
| Detection Limit | 0.1 mg/L COD |
| Analysis Time | ≤30 min per batch |
| Batch Capacity | 15 samples |
| Cuvette Recognition | Automatic barcode-based identification for round and rectangular cuvettes (10 mm, 20 mm, 50 mm path lengths) |
| Compliance | Designed for ASTM D1252, ISO 6060, EN 1484, and US EPA Method 410.4 workflows |
| Key | Origin: Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TresCon A |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Ammonia-N (NH₄⁺-N), Total Phosphorus (TP), Total Nitrogen (TN) |
| Module Capacity | Up to 3 Independent Analytical Modules |
| Compliance | Designed for ISO/IEC 17025-aligned operation, supports GLP/GMP data integrity requirements via audit-trail-enabled software |
| Communication | RS-485, Modbus RTU, optional analog 4–20 mA outputs and Ethernet/IP integration |
| Key | Chamber Internal Dimensions: 400 × 1250 × 700 mm (D×W×H) |
|---|---|
| External Dimensions | 450 × 1350 × 1700 mm (D×W×H) |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | 65–95% RH |
| Sample-to-Lamp Distance | 240 mm |
| Spectral Range | 295–330 nm |
| Irradiance | 1000 µW/cm² @ 340 nm |
| Illumination & Condensation Cycle | Programmable |
| Lamp Configuration | 8 × 1200 mm, 40 W xenon arc lamps |
| Interior Material | SUS304 stainless steel |
| Control System | Fuji digital temperature controller (Japan) + programmable timer |
| Water Consumption | ~8 L/day (deionized or distilled water recommended) |
| Condensation Method | Gravity-fed, non-pressurized dew formation |
| Key | Chamber Interior Dimensions: 500 × 700 × 600 mm |
|---|---|
| Temperature Range | RT to +80 °C (adjustable) |
| Humidity Range | 45–90 % RH (adjustable) |
| Black Panel Temperature | 63 °C or 100 °C ±2 °C |
| Temperature Uniformity | ±2.0 °C |
| Temperature Fluctuation | ±0.5 °C |
| Humidity Deviation | ≤±2 % RH |
| Xenon Lamp Type | Air-Cooled, 1.8 kW |
| Spectral Range | 290–800 nm |
| Irradiance (290–800 nm) | 550 W/m² |
| Sample Rack Distance from Lamp | 230–280 mm |
| Rainfall Duration | 0–9999 min (continuous) |
| Rainfall Cycle | 0–240 min (cyclic/intermittent) |
| Nozzle Orifice Diameter | Ø0.8 mm |
| Heating Power | 3 kW |
| Humidification Power | 1.5 kW |
| Total Rated Power | 9 kW |
| Sample Tray | 1-layer, height-adjustable |
| Filter Glass | 1 piece |
| Compliance | Designed per ISO 4892-2, ASTM G155, SAE J2527, and GB/T 16422.2 |
| Key | Temperature Range: RT+10°C to 70°C |
|---|---|
| Humidity Range | 50–98% RH |
| Black Panel Temperature | 63–100°C ±3°C |
| Temp. Uniformity | ≤±2.0°C |
| Temp. Stability | ≤±0.5°C |
| Humidity Stability | +2% to −3% RH |
| Rain Duration | 1–9999 min (adjustable, continuous) |
| Rain Cycle | 1–240 min (adjustable, intermittent) |
| Nozzle Diameter | Ø2.0 mm |
| Water Pressure | 0.12–0.15 MPa |
| Spray Cycle | 18 min ON / 102 min OFF or 12 min ON / 48 min OFF |
| Lamp Type | Air-Cooled Xenon Arc Lamp |
| Lamp Quantity | 1 |
| Lamp Power | 2–6 kW |
| Sample Distance from Lamp | 300–375 mm |
| Sample Holder Rotation | 360°, 1–5 rpm |
| Irradiance Spectrum | 290–800 nm |
| Irradiance Range | 50–1100 W/m² |
| Cumulative Radiant Exposure | 14,000–67,000 kJ/m² |
| Illumination Time Control | 1–999 h (continuously adjustable) |
| Power Supply | AC 380 V (±10%), 50 Hz, 3-phase 5-wire |
| Key Features | 500L or 700L chamber volume |
|---|---|
| Xenon lamp power | 4.5 kW / 6.0 kW (long-arc, full-spectrum solar simulation) |
| Irradiance control | 550 W/m² (at 340 nm or 420 nm band, adjustable) |
| Black panel temperature range | 50–90 °C |
| Temperature uniformity | ≤ ±3 °C |
| Relative humidity range | 55–90 %RH |
| Sample-to-lamp distance | 250–300 mm |
| Effective exposure area | 1600 cm² |
| Lamp service life | ≈1200 h |
| Spray cycle | programmable on/off duration up to 999 min each |
| Power supply | 380 VAC / 50 Hz, total rated power 12 kW / 15 kW |
| Controller | programmable touchscreen with xenon-specific algorithm and real-time irradiance feedback via fiber-optic sensor |
| Cooling | forced-air convection with axial fan and PID-controlled thermal management |
| Safety | interlocked door switch (lamp auto-off), overtemperature protection, dry-run prevention for spray system |
| Key | Power Supply: 380 V AC / 50 Hz |
|---|---|
| Total Power | 9 kW |
| Xenon Lamp | 6 kW water-cooled long-arc lamp (full solar spectrum) |
| Irradiance Control Range | 350–850 nm, nominal 550 W/m² |
| Optional Monitoring Wavelengths | 340 nm or 365 nm |
| Temperature Range | (RT + 10)°C to 70°C |
| Temperature Uniformity | ±2°C |
| Sample Rotation Speed | ≥1 rpm (stepless adjustment) |
| Wet/Dry Cycle Options | 60 min irradiation / 12 min spray or 102 min / 18 min |
| Chamber Interior Dimensions | 950 × 950 × 900 mm |
| Spray Pressure | 78–127 kPa |
| UV Cut-off Filter | <255 nm blocked (0%), 400–800 nm transmittance >90% |
| Construction | Cold-rolled steel exterior with powder coating, SUS304 stainless steel interior, silicone rubber door seal |
| Control System | South Korean TEMI850 touchscreen controller |
| Cooling | Closed-loop chiller system for xenon lamp |
| Radiation Measurement | Fiber-optic coupled broadband radiometer |
| Temperature Sensing | Wireless black panel thermometer (BPT) or black standard thermometer (BST) |
| Safety | Interlocked cooling-water circuit, overtemperature/overcurrent/short-circuit protection, low-water cutoff, grounding protection |
| Key | Working Chamber Size: Customizable |
|---|---|
| Humidity Range | 40–98% RH |
| Temperature Range | 10–70 °C |
| Black Panel Temperature | 40–110 °C |
| Temperature Uniformity | ±2 °C |
| Temperature Stability | ≤±0.5 °C |
| Humidity Deviation | ≤±3% RH |
| Rainfall Cycle | 1–9999 min (adjustable, continuous or periodic) |
| Light Source | Long-Arc Air-Cooled Xenon Lamp |
| Lamp Power Options | 1.5 / 2.5 / 3.0 / 6.0 kW per lamp |
| Lamp Lifetime | ≥1500 h |
| Total Exposure Area | ≥6000 cm² |
| Irradiance Range | 0–1100 W/m² (solar-spectrum-weighted) |
| Spectral Range | 280–900 nm |
| Irradiance Monitoring Points | 340 nm, 300–400 nm, 420 nm |
| Light Intensity Control | 5–100% |
| Light/Dark Cycle | 10 min – 99.99 min |
| Cooling Method | Air-cooled heat exchanger + air-cooled compressor |
| Filter System | Borosilicate & soda-lime optical glass filters (manual exchange for indoor/outdoor simulation) |
| Control Interface | Touchscreen HMI with embedded control software, data logging ≥2 years, USB export capability |
| Structural Material | 1.2 mm SUS316L stainless steel |
| Observation Window | 300 × 700 mm multilayer insulated radiation-shielded glass with UV-filtering overlay |
| Compliance | ASTM G155, ASTM D4459, GB/T 2423.24, GB/T 5137.3 |
| Temperature Range | RT+10°C to 70°C |
|---|---|
| Humidity Range | 65–98% RH |
| Rainfall Duration | 1–9999 h 59 min (adjustable) |
| Rainfall Cycle | 1–240 min (interval adjustable) |
| Irradiance | ≤300 W/m² (at specimen plane, 300–800 nm) |
| Xenon Lamp Total Power | 12.0 kW (rated lifetime: ≥1600 h) |
| Control Accuracy | Temperature ±0.1°C (set/indicated), Humidity ±1% RH |
| Black Panel Temperature Sensor | Dual-metal thermometric type |
| Heating System | Independent Ni-Cr alloy resistive heaters |
| Humidification System | External stainless steel shallow-surface evaporative humidifier |
| Air Circulation | Low-noise, high-temp-resistant centrifugal blower with multi-blade impeller |
| Power Supply | AC 380 V ±10%, 50 ±0.5 Hz, 3-phase 4-wire |
| Ambient Operating Conditions | 5–30°C, ≤85% RH |
| Key | Brand – Other Brands |
|---|---|
| Construction – Interior | SUS304 stainless steel |
| Exterior | Powder-coated steel |
| Key | Irradiance at 340 nm: 0.5 W/m² |
|---|---|
| Irradiance at 300–400 nm | 60 W/m² |
| Test Chamber Interior Dimensions (H×D×W) | 800 × 900 × 800 mm |
| Lamp Type | 4500 W water-cooled xenon arc lamp |
| Filter Options | Borosilicate (267–800 nm) or Soda-lime (300–800 nm) |
| Sample Turntable Diameter | 690 ± 3 mm |
| Construction | Interior and exterior of SUS#304 stainless steel (1.0 mm thickness, brushed finish interior / powder-coated exterior) |