Generic
Filter
Showing 211–240 of 1032 results
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AFR Lab |
| Quotation | Upon Request |
| Usable Volume | Medium-Scale |
| Construction Material | Specialty Glass / PFA / PETE / Perfluoroelastomer |
| Operating Pressure | High-Pressure (0–18 bar(g)) |
| Capacity | 2.7 mL per reactor module |
| Vacuum Capability | Not Specified |
| Key Features | LCD digital temperature & humidity controller |
|---|---|
| Segment duration | 0–999 h 59 min |
| Loop count | 1–999 partial or 0–999 full cycles |
| Chamber material | seamless fiberglass-reinforced plastic (FRP) |
| Interior components | stainless steel, copper, or corrosion/heat-resistant materials |
| Safety protections | leakage current, short circuit, overtemperature, low-water, end-of-test, overcurrent |
| Compliance | GB/T 2423.17–2022, IEC 60068-2-11, ASTM B117, ISO 9227, DIN 50021 |
| Temperature range | +5°C to 55°C |
| Humidity range | 85–95% RH |
| Temp. uniformity | ≤ ±2°C |
| Temp. stability | ≤ ±0.5°C |
| Salt deposition rate | 1–2 mL / 80 cm²·h |
| Spray modes | continuous or cyclic |
| Timer range | 1–999 (s/min/h) |
| Power supply | AC 220V±10% / 380V±10%, 50 Hz |
| Ambient operating conditions | 5–30°C, ≤85% RH |
| Heating system | independent Ni-Cr alloy heaters |
| Spray system | tower-type atomizer with non-crystallizing nozzles |
| Salt solution pre-heating | thermally balanced with chamber air |
| Filtration | inline water filter on suction line |
| Calibration-ready | PT100 platinum resistance sensors, standard funnel & graduated cylinder for deposition measurement |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | LabLincV |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DC24000 UHR |
| Price Range | USD 110,000–138,000 (FOB) |
| Particle Size Range | 5 nm – 75 µm |
| Size Measurement Repeatability | ±0.5% RSD |
| Operating Temperature | Ambient (15–30 °C) |
| Light Source Wavelength | 405 nm (violet diode laser) |
| Measurement Principle | High-Speed Centrifugal Sedimentation (HSCS) |
| Sample Mass Range | 0–10 ng |
| Sample Concentration | Matrix-independent (no dilution requirement) |
| Zeta Potential Capability | Not integrated |
| Typical Analysis Time | 1–3 minutes per run |
| Molecular Weight Determination | Not supported |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | CrystalCam |
| Price | ¥1,000,000 |
| Spatial Resolution | 1 mm |
| Temporal Resolution | 80,000 fps |
| Gray Scale | 256 levels |
| Time Gain Control (TGC) | 100 dB |
| Measurement Function | Radionuclide Distribution Imaging |
| Dynamic Range Adjustment | 100–130 dB |
| Display Modes | Radionuclide Scintigraphy, SPECT/CT Fusion |
| Maximum Penetration Depth | 1000 mm |
| Dimensions | 65 × 65 × 180 mm³ |
| Weight | 800 g (incl. collimator & shielding) |
| Integrated Lateral Shielding | 99.97% attenuation for ⁹⁹ᵐTc |
| Field of View | 40 × 40 mm² @ 16 × 16 pixels |
| Energy Range | 50–240 keV (optional: 50–1000 keV) |
| Energy Resolution | <5.5% FWHM at 140 keV (⁹⁹ᵐTc) |
| Sensitivity | >500,000 cps/MBq (uncollimated), >2,000 cps/MBq (LEHS), >450 cps/MBq (LEHR), >190 cps/MBq (LEGP) |
| Extrinsic Spatial Resolution | 5.4 mm FWHM at 35 mm (LEHR), 9.2 mm FWHM at 35 mm (LEHS), 6.1 mm FWHM at 35 mm (LEGP) |
| Power Supply | USB-powered |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS325 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HT200 |
| Pricing | Upon Request |
| Key | Table Surface Dimensions: 500 × 500 mm |
|---|---|
| Vibration Axes | Dual-axis (horizontal + vertical) |
| Max Payload | 100 kg |
| Frequency Range | 1–600 Hz |
| Sweep Frequency Range | 1–600 Hz |
| Displacement Amplitude | 0–5 mm peak-to-peak |
| Max Acceleration | 20 g (rms) |
| Time Control Resolution | 1 second (programmable up to 1 year) |
| Waveforms | Sine, Half-sine |
| Drive Power | 2.2 kVA |
| Input Voltage | 220 V ±10% AC, 50/60 Hz |
| Max Current Draw | 5 A |
| Frequency Display Resolution | 0.01 Hz |
| Shaker Body Dimensions (vertical unit) | 500 × 500 × 160 mm |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range (optional) | 20–98% RH |
| Rapid TC Range | -45°C to +85°C |
| Rapid TC Accuracy | ±3.0°C |
| Ramp Rates | 5–30°C/min (selectable A–F types) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.5% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Temp. Resolution | 0.1°C |
| Humidity Resolution | 0.1% RH |
| Construction | SUS304 inner chamber, stainless steel or SECC cold-rolled steel with powder coating outer shell |
| Insulation | High-density polyurethane foam |
| Cooling | Water-cooled |
| Compressor Options | Tecumseh (France), Bitzer (Germany) |
| Power Supply | AC380V, 3-phase 5-wire, 50/60 Hz |
| Weight Range | 950–2300 kg |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, GJB 150.5, GJB 360.7, IEC 60068-2-14 (Test N), QC/T 17, EIA-364-32 |
| Safety Protections | High/low pressure cut-off, over-temperature/over-humidity protection, compressor overload protection, fuse, water shortage alarm, fault warning system |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range | 30–98% RH |
| Temp. Uniformity | ≤ ±2.0°C |
| Temp. Stability | ≤ ±0.5°C |
| Humidity Stability | +2 to –3% RH |
| Cooling Rate (no load) | 0.7–1.0°C/min |
| Heating Rate (no load) | 1.0–3.0°C/min |
| Vibration Type | Electromagnetic Shaker |
| Frequency Range | 2–500 Hz |
| Displacement Amplitude | 0–5 mm |
| Acceleration Capacity | 0–20 gₚₖ |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.3, GB/T 2423.10, GB/T 2423.48, GB/T 2423.49, GB 10586, GB 10589, GB 10592, GB 11158, GB/T 5170.2, GB/T 5170.5 |
| Key Features | Microprocessor-based color touchscreen controller with EN/CN language switch |
|---|---|
| Temperature range options | 0 to 150°C, −20 to 150°C, −40 to 150°C, or −70 to 150°C |
| Humidity range | 20–98% RH (optional: 5–98% RH) |
| Temp. uniformity | ±0.5°C |
| Humidity uniformity | ±2.5% RH |
| Temp. fluctuation | ±2°C |
| Humidity fluctuation | +2–3% RH |
| Resolution | 0.1°C / 0.1% RH |
| Heating rate | ~4.0°C/min |
| Cooling rate | ~1.0°C/min |
| Standard accessories | Two-tier SUS#304 shelves, four casters + four leveling feet, 2.5 m AC380 V±5%, 50 Hz±0.5 Hz, 3-phase 5-wire power cable |
| Temperature Range | -40 °C to +100 °C |
|---|---|
| Humidity Range | 20–98 %RH (optional down to 5 %RH) |
| Temperature Uniformity | ≤ ±0.5 °C |
| Temperature Deviation | ≤ ±2 °C |
| Humidity Deviation | +2 to –3 %RH |
| Ramp Rate | 0.5–1.2 °C/min |
| Control System | Microprocessor-based PID + SSR + Timer |
| Compliance | IEC 60068-2, ISO 16750-4, ASTM D4332, GB/T 2423.1/2/3/4 |
| Refrigerant | R404A/R507 (ODP = 0, compliant with EU F-Gas Regulation) |
| Key | Controller: Siemens PLC + color LCD touch panel |
|---|---|
| Temp. setpoint accuracy | ±0.1 °C |
| Temp. indication accuracy | ±0.1 °C |
| Sensor | PT100 Ω platinum RTD |
| Heating | independent Ni-Cr alloy resistive heaters |
| Refrigeration | French Tecumseh hermetic air-cooled single-stage or cascade compressor system |
| Air circulation | low-noise HVAC-grade motor with multi-blade centrifugal impeller |
| Internal dimensions | 600 × 500 × 500 mm (W×H×D) |
| External dimensions | 1500 × 2100 × 2250 mm (W×H×D) |
| Construction | SUS304 stainless steel interior & exterior |
| Insulation | high-density glass wool + rigid polyurethane foam |
| Door | single pneumatic-assisted access door |
| Accessories | cryo/heat-resistant silicone packing (−200 °C to +400 °C), dual-zone auto-switching mechanism, two adjustable stainless steel test trays |
| Compliance | Designed per IEC 60068-3-5, ASTM D3418, and ISO 16750-4 environmental stress testing protocols |
| Temperature Range | -40 °C to +100 °C |
|---|---|
| Humidity Range | 30–98 %RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤2 °C |
| Humidity Deviation | +2 to –3 %RH |
| Ramp Rate | 0.5–1.2 °C/min |
| Compliance | GB10589, GB10592, GB11158, GB/T5170.2, GB/T5170.5, GB2423.1/2/22, GB2424.1 |
| Key | Max Load: 100 kg (customizable) |
|---|---|
| Frequency Range | 1–5000 Hz (0.01 Hz resolution) |
| Sweep Range | 1–5000 Hz (duration: 1 s to 30 days) |
| Peak-to-Peak Amplitude | 0–5 mm |
| Max Acceleration | 20 g |
| Vibration Axes | Vertical + Horizontal |
| Waveform | Sinusoidal |
| Programmable Segments | Up to 15 segments, each with user-defined frequency/time |
| Octave Sweeps | 5-segment logarithmic (low→high, high→low, low→high→low, repeatable) |
| Table Surface | 50 × 50 cm (customizable) |
| Cabinet Dimensions (Vertical Mode) | 50 × 20 × 50 cm (L×H×W) |
| Power Supply | 220 V ±20%, 5 A, 2.2 kW |
| Control Modes | Programmable, sweep, logarithmic, octave, amplitude/acceleration regulation, time-based termination |
| Compliance | Designed for IEC 60068-2-6, IEC 60068-2-64, MIL-STD-810H, ISO 16750-3, GB/T 2423.10, GB/T 2423.3, GB/T 2423.17 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cybi-FeliX |
| Pricing | Available Upon Request |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AxiChrom |
| Pricing | Available Upon Request |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CYW-300S |
| Price | USD 1,700 (FOB) |
| Filter Diameter | Φ47 mm / Φ50 mm |
| Effective Filtration Area | 40 mm |
| Cup Capacity | 100 mL |
| Number of Filtration Heads | 3 |
| Filtration Method | Vacuum-Driven Membrane Filtration |
| Filtration Rate | 100 mL per 15 s |
| Sterilization Options | Autoclave (121 °C, 15–20 min), Flame Sterilization (for filtration heads only) |
| Filtration Head Design | Removable, Lip-Seal Integrated, Clamp-Free, O-Ring-Free |
| Pump Interface | External Oil-Free Vacuum Pump (not included) |
| Material | Electropolished 316L Stainless Steel Base & Filtration Heads |
| Surface Finish | Mirror-Polished AISI 316L SS |
| Compliance | Designed in accordance with ISO 8573-1 (compressed air purity), USP <61> & <62>, Ph. Eur. 2.6.12, and Chinese Pharmacopoeia 2020 Edition IV.1107 |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic (China) |
| Model | DVIO-R Series |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DAS 200 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Definer220 |
| Pricing | Available Upon Request |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DELTA1111 |
| Quotation | Available upon Request |
| Test Standards | ISO 6925, CFR 1630/1631, BS 6307, BS 4790, GB/T 20394–2013, GB/T 11049–2008, GB/T 14768–2015 |
| Sample Size | 230 mm × 230 mm (8 specimens per test) |
| Heating Source | Hot Metal Nut Method & Hexamethylenetetramine (Urotropine) Pellet Method |
| Ignition | Automatic Pulse Ignition |
| Timing Range | Flame Application Time: 0–99 s/min |
| Flame Application & Withdrawal Interval | 1.0–999.9 s (digital preset) |
| Afterflame Time | 1.0–999.9 s (digital readout) |
| Repetition Cycles | 1–9999 (digital preset) |
| Test Chamber Dimensions | 300 mm × 300 mm × 300 mm (W×D×H) |
| Ventilation Hood Volume | 2 m³ with Auto-Exhaust & Explosion-Proof Lighting |
| Exhaust Duct Diameter | Ø110 mm |
| Control System | PLC + 7-inch HMI Touchscreen |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Stainless Steel Hot Plate | 230 mm × 230 mm × 6.5 ±0.5 mm, central aperture Ø205 mm |
| Desiccant | Color-Indicating Silica Gel GPE0038 |
| Safety Features | Interlocked Protective Door, Black Interior Finish, Observation Window with Integrated LED Illumination |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | DeskCAT |
| Quotation | Upon Request |
| Medical Device Registration Number | Not Applicable |
| Key | Temperature Range: –40 °C to +150 °C (standard) |
|---|---|
| Humidity Range | 30–98% RH (standard) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 color LCD touchscreen programmable controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (customizable to 220 V) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or A3 steel with electrostatic powder coating |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DFC-3BT |
| Price Range | USD 700–1,400 |
| Sampling Flow Rate | 5–30 L/min |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±0.1% |
| Maximum Negative Pressure | ≥15,000 Pa |
| Charging Current | 300 mA (standard) |
| Power Supply | 10 V DC / 220 V AC, 50 Hz |
| Operating Temperature | −25°C to +45°C |
| Sound Pressure Level | ≤60 dB(A) |
| Relative Humidity | ≤85% RH |
| Dimensions | 200 × 160 × 140 mm |
| Origin | China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | DGF3006B |
| Price | USD 695 (FOB China) |
| External Dimensions (D×W×H) | 100×130×128 cm |
| Chamber Dimensions (D×W×H) | 80×80×100 cm |
| Chamber Volume | 640 L |
| Temperature Range | Ambient +20 °C to 300 °C |
| Temperature Uniformity | ±2.5% of setpoint |
| Temperature Fluctuation | ±0.5 °C |
| Heating Power | 5.5 kW |
| Chamber Construction | Stainless Steel Interior |
| Air Circulation | Forced Convection with Adjustable Rear Wall Fan |
| Control System | PID Digital Temperature Controller with LED Display |
| Safety Features | Independent Over-Temperature Cut-Off and Short-Circuit Protection |
| Compliance | JB/T 5520–1991 “Technical Specifications for Drying Ovens” |
| [Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 111P |
| Price | Upon Request |
| Vessel Diameter Range | >60 µm |
| Tension Range | ±50 mN |
| Tension Resolution | 0.01 mN |
| Pressure Range | 0–250 mmHg |
| Pressure Accuracy | ±0.1 mmHg |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.1 °C |
| Bath Volume | Up to 10 mL (3 mL standard) |
| Bath Material | Acid-Resistant Stainless Steel |
| Heating | Integrated Electronic Feedback Control |
| Analog Output | 1.0 V F.S. (12-bit) |
| Digital Interface | RS232 / RS485 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Environmental Operating Temp | 15–30 °C] |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | FM-120 |
| Measurement Range | 2–50 µm |
| Sampling Area | 0.24 mm² |
| Volumetric Flow Rate | 1 m³/min |
| Sampling Frequency | Adjustable from 0.04 s to 20 s |
| Refractive Index Assumption | 1.33 (non-absorbing, water standard) |
| Scattering Collection Angle | 3.5°–12° (annular forward cone) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 0–100 % RH (non-condensing) |
| Altitude Limit | ≤ 4,000 m |
| Instrument Weight | 10.0 kg |
| External Pump Weight | 9.5 kg |
| Dimensions (Detector Unit) | 23 cm (W) × 37 cm (L) × 28 cm (H) |
| Power Supply | FM-120 unit: 85–264 VAC, 50–60 Hz |
| External pump | 220 VAC |
| Data Interface | RS-422 or RS-232 |
