| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 700 Series, ASTM D323, D4953, D5482, D5191 |
| Measurement Range | 0–35 psi (0–250 kPa) |
| Cycle Time | ≤5 min |
| Repeatability | ±0.05 psi (±3.5 mbar) |
| Temperature Control | 37.8 °C ±0.1 °C |
| Pressure Resolution | ±0.01 psi |
| Pressure Accuracy | ±0.01% of full scale |
| Sample Flow Rate | 0.04–0.1 L/min |
| Sample Pressure | 20–35 psi (1.4–2.4 bar), optional up to 120 psi (8.3 bar) |
| Sample Particle Size | ≤10 µm |
| Enclosure Rating | NEMA 4X / IP65 |
| Hazardous Area Certification | NEC Class 1 Div 1 Group C+D / ATEX Zone 1 II 2G IIB+H2 T4 |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASTM D566 |
| Pricing | Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 256000/M, ASTM D6 |
| Power Supply | 220 V / 50 Hz, 2000 W |
| Temperature Range | Ambient to 180 °C ± 1 °C |
| Temperature Control Accuracy | ±0.1 °C (PID + Pt100 RTD) |
| Rotational Speed | 5.5 rpm (adjustable 5–6 rpm) |
| Internal Chamber Dimensions | 60 × 80 × 80 cm (W × H × D) |
| Net Weight | ~30 kg |
| Safety Certification | CE |
| Compliance Standards | ASTM D6, ASTM D1754, IP 145 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AD0972-100 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASTM IRB9 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASTM ITRB2 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Type | Imported |
| Model | 780 |
| Compliance | ASTM D323, D4953, D5482, D5181, D5188 |
| RVP Range | 0–35 psi (0–250 kPa) |
| VL20 Temperature Range | 25–65 °C |
| Cycle Time | ≤5 min per mode |
| Repeatability | ±0.05 psi (±3.5 mbar) for RVP |
| Operating Environment | NEMA 4X / IP65 |
| Sample Flow Rate | 0.04–0.1 L/min |
| Sample Particle Size | ≤10 µm |
| Purge Gas | Dry nitrogen ≥98% purity, 40–100 psi |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MYL-D1076 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ASTN-D1-W150 |
| Component Category | Broadband Tunable Light Source |
| Light Source Configuration | Single 30 W Deep-UV Deuterium Lamp + 150 W Halogen Lamp |
| Typical Deuterium Lamp Lifetime | 1,000 h (min. 500 h) |
| Typical Halogen Lamp Lifetime | 50–2,000 h |
| Monochromator | CM110, f/3.9 |
| Grating Capacity | Dual pre-installed gratings |
| Interface | RS-232 Serial |
| Scan Modes | Bidirectional |
| Scan Units | nm, Å, cm⁻¹, eV |
| Optional IR Extension | SiC Thermal Source (1–16 µm) |
| Fiber Coupling Options | SMA, FC, CS Ferrule (AFCM-L-XX series, sold separately) |
| Filter Mount | AB202 |
| Filter Series | AB3XXX |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AstraGene SX2 |
| Pricing | Available Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | REL0100 / REL0230 |
| Viscosity Range | 0.1 Pa·s to 1 × 10⁶ Pa·s (typical for rotational viscometry with coaxial cylinder geometry) |
| Speed Range | 5–900 rpm |
| Temperature Range (REL0100) | 10–100 °C |
| Temperature Range (REL0230) | 25–230 °C |
| Compliance | BS EN ISO 2884-1:2006 |
| Units | °C/°F, rpm/s⁻¹, Poise/Pa·s |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Warm-up Time | 10 min |
| Dimensions (H×W×D) | 510 × 302 × 302 mm |
| Weight | 13.5 kg (REL0100), 13.0 kg (REL0230) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | CM-800α Online Refractometer |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DR-A1 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DR-A1-Plus |
| Price | Upon Request |
| Measurement Range | nD 1.3000–1.7100 |
| Temperature Compensation | 5–50°C |
| Resolution | nD 0.0001, Brix 0.1% |
| Accuracy | ±0.0002 (nD), ±0.1% (Brix) |
| Operating Temp | 5–50°C (0.1°C resolution) |
| Power Consumption | 16 VA |
| Input | AC adapter (100–240 V, 50/60 Hz) |
| Dimensions (Refractometer) | 13 × 29 × 31 cm, 6.0 kg |
| Dimensions (Adapter) | 10.5 × 17.5 × 4 cm, 0.7 kg |
| Interface | RS-232C (optional) |
| Optional Printer | DP-22(C) |
| Calibration Standards | Certified sucrose solutions (10–60%, ±0.03–0.05% tolerance) |
| Accessories | Polarizing eyepiece (RE-1146), prism set (RE-1501), desiccant (RE-1592), calibration kit (RE-1195) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DR-M2/1550(A) |
| Price | Upon Request |
| Wavelength Range | 450–1550 nm |
| Refractive Index Range (at 450 nm) | 1.3278–1.7379 |
| Refractive Index Range (at 589 nm) | 1.3000–1.7100 |
| Refractive Index Range (at 680 nm) | 1.2912–1.7011 |
| Refractive Index Range (at 1100 nm) | 1.2743–1.6840 |
| Refractive Index Range (at 1550 nm) | 1.2662–1.6759 |
| Minimum Display Resolution | RI ±0.0001, Abbe Number ±0.1 |
| Accuracy (RI at 589 nm) | ±0.0002 (with certified calibration plate) |
| Temperature Control Range | 5–50 °C |
| Light Source | Monochromatic LED-based source with interference filters |
| Dimensions (Refractometer Unit) | 23 × 35 × 21–31 cm |
| Weight (Refractometer Unit) | 5.9 kg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 100 VA (main unit + power supply) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MASTER-50H |
| Product Type | Handheld Refractometer |
| Temperature Control | Built-in ATC (Automatic Temperature Compensation) |
| Display | Digital LCD |
| Measurement Range | Brix 0.0–50.0% |
| Accuracy | ±0.5% Brix |
| Repeatability | ±0.25% Brix |
| Dimensions | 3.2 × 3.4 × 16.8 cm |
| Weight | 130 g |
| IP Rating | IP65 (excluding eyepiece) |
| Prism Material | Reinforced optical glass |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MASTER-S/Millα |
| Price | Upon Request |
| Scale Range | Salinity 0–100‰, Specific Gravity 1.000–1.070 |
| Minimum Scale Division | Salinity 1‰, Specific Gravity 0.001 |
| Accuracy | ±1‰ (salinity), ±0.001 (specific gravity) within 10–30°C |
| Temperature Compensation | Automatic (ATC), built-in thermistor |
| IP Rating | IP65 (excluding eyepiece) |
| Dimensions | 3.2 × 3.4 × 20.7 cm |
| Weight | 110 g |
| Replacement Prism Plate | RE-2471-56M |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MASTER-S28α |
| Price Range | USD 140–420 (FOB) |
| Measuring Principle | Abbe Refractometry |
| Scale Range | NaCl 0.0–28.0% w/w |
| Resolution | 0.2% NaCl |
| Accuracy | ±0.2% NaCl (at 10–30°C) |
| Automatic Temperature Compensation (ATC) | Built-in bimetallic compensator (5–35°C range) |
| IP Rating | IP65 |
| Dimensions | 3.2 × 3.4 × 16.8 cm |
| Weight | 90 g |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MASTER-URC/Nα |
| Pricing | Upon Request |
| Scale Range (Urine SG) | 1.000–1.050 |
| Scale Range (Refractive Index nD) | 1.333–1.356 |
| Minimum Scale Division (SG) | 0.001 |
| Minimum Scale Division (nD) | 0.0005 |
| Accuracy (SG) | ±0.001 |
| Accuracy (nD) | ±0.0005 (at 10–30°C) |
| Automatic Temperature Compensation | Yes |
| IP Rating | IP65 (excluding eyepiece) |
| Dimensions | 3.2 × 3.4 × 20.7 cm |
| Weight | 110 g |
| Compatible Accessory | MASTER Series Light Guide Plate RE-2471-56M |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MASTER-VET |
| Price | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MASTER-α |
| Price | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NAR-1T SOLID (1212) |
| Price | Upon Request |
| Refractive Index (nD) Range | 1.3000–1.7000 |
| Brix Range | 0.0–95.0% |
| nD Resolution | 0.001 |
| Brix Resolution | 0.5% |
| nD Accuracy | ±0.0002 |
| Brix Accuracy | ±0.1% |
| Temperature Display Range | 0.0–50.0°C (Accuracy: ±0.2°C |
| Resolution | 0.1°C) |
| Measurement Temp. Range | 0–50°C |
| Light Source | LED |
| Power Supply | 115/220/240 V, 50/60 Hz |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NAR-4T |
| Price | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PAL-1 |
| Price | Upon Request |
| Brix Range | 0.0–53.0% |
| Temperature Range | 9.0–99.9°C |
| Brix Resolution | 0.1% |
| Temperature Resolution | 0.1°C |
| Brix Accuracy | ±0.2% |
| Temperature Accuracy | ±1.0°C |
| Ambient Operating Temperature | 10–40°C |
| Sample Temperature Range | 10–100°C (with Automatic Temperature Compensation, ATC) |
| Sample Volume | 0.3 mL |
| Measurement Time | 3 seconds |
| Power Supply | 2 × AAA batteries |
| Ingress Protection Rating | IP65 |
| Dimensions | 55(W) × 31(D) × 109(H) mm |
| Weight | 100 g (without accessories) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PAN-1 |
| Pricing | Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PEN-URINE S.G. |
| Price | Upon Request |
| Measurement Range | 1.0000–1.0600 (Urine Specific Gravity) |
| Resolution | 0.0001 |
| Accuracy | ±0.0010 |
| Ambient Operating Temperature | 10–40°C |
| Sample Volume | 0.3 mL |
| Power Supply | 1 × AAA Alkaline Battery |
| Measurement Time | 2 seconds |
| IP Rating | IP65 (Instrument Body), IP67 (Prism Housing) |
| Dimensions | 16(W) × 38(D) × 18(H) mm |
| Weight | 70 g (without accessories) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PR-50HO |
| Price | Upon Request |
| Measurement Range | 0.0–50.0% (w/w) H₂O₂ |
| Resolution | 0.1% (w/w) |
| Accuracy | ±0.5% (w/w) |
| Temperature Compensation Range | 5–40°C (Automatic, ATC) |
| Operating Ambient Temperature | 5–40°C |
| Power Supply | 9V Alkaline Battery (006P) |
| IP Rating | IP64 |
| Dimensions | 170 × 90 × 40 mm |
| Weight | 300 g (body only) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | RX-9000α |
| Pricing | Upon Request |
| Refractive Index (nD) Range | 1.32500–1.70000 |
| Brix Range | 0.00–100.00% (ATC: 5–70°C) |
| nD Resolution | 0.00001 / 0.0001 |
| Brix Resolution | 0.01% / 0.1% |
| Temperature Resolution | 0.01°C |
| nD Accuracy | ±0.00004 (1.33299–1.42009, 10.00–30.00°C) |
| Brix Accuracy | ±0.03% (0.00–50.00%, 10.00–30.00°C) |
| nD Repeatability | ±0.00002 (1.33299–1.42009, 10.00–30.00°C) |
| Brix Repeatability | ±0.01% (0.00–50.00%, 10.00–30.00°C) |
| Temperature Control Range | 5–70°C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions & Weight | 37 × 26 × 14 cm, 6.9 kg |
| Power Consumption | 65 VA |
| Interface Options | RS-232C, optional thermal printer (DP-RX / DP-RD) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ME2 |
| Price | USD 198,000 (FOB) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ATLEX |
| Price | USD 55,000 (FOB Hamburg) |
| Core Technology | Gas-based Pulsed UV Excimer Laser System |