| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 3H16RI |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (High-Speed) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Level | Cellular & Bacterial |
| Max Capacity | 4 × 100 mL |
| Max Speed | 16,800 rpm |
| Max RCF | 20,320 × g |
| Dimensions | 710 × 630 × 350 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤60 dB(A) |
| Power Supply | 220 V, 50 Hz |
| Weight | 75 kg |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registered |
| Rotor Recognition | Automatic |
| Display | TFT-LCD touchscreen + physical keys |
| Language Options | English, Chinese, Russian, Portuguese |
| Refrigerant | R404a (non-ozone-depleting, RoHS 2015/863 compliant) |
| Safety | Airtight biocontainment rotors with silicone sealing, triple-layer steel protection housing, rear stainless-steel chamber, brushless DC motor with 3-stage damping, real-time imbalance detection, overspeed/overtemperature/under-voltage/over-voltage protection |
| Pre-cooling & Hold-at-Temp | Yes |
| Defrost Mode | Electric heating defrost |
| Programmability | 100 user-defined protocols, parameter editing during run, last-program recall on startup |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | Hettich 710BY |
| Price Range | USD 1,400 – 4,200 |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Low-Speed Centrifuge (≤ 5,000 rpm) |
| Function | General-Purpose Centrifuge |
| Configuration | Fixed-Angle Rotor System |
| Maximum Capacity | 4 × 250 mL |
| Max. Rotational Speed | 4,000 rpm |
| Max. RCF | 2,578 × g |
| Dimensions (W × D × H) | 330 × 330 × 251 mm |
| Acceleration/Deceleration Stages | 10-step programmable |
| Construction | AISI 304 stainless steel chamber + powder-coated steel housing + triple-layer reinforced safety shield |
| Control Interface | Bluetooth 5.0 + WeChat Mini Program (iOS/Android) |
| Operational Range | Up to 10 m line-of-sight |
| Connectivity Features | Real-time Bluetooth signal strength monitoring, auto-reconnect on dropout, parameter retention after power cycle, runtime logging with timestamped event records |
| Key | Brand: Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 7116R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–16,500 rpm |
| Max RCF | 22,500 × g |
| Max Capacity | 48 × 2.0 mL tubes |
| Temperature Range | −20 °C to +40 °C |
| Display | 7-inch capacitive touchscreen |
| Dimensions (W×D×H) | 650 × 350 × 325 mm |
| Rotor Configuration | Fixed-angle rotor standard (compatible with PCR 8-tube strips, 0.2–2.0 mL microtubes) |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BE-6100H |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 2500 rpm |
| Max RCF | 500 × g |
| Max Capacity | 2 × 96-well PCR plates |
| Rotor Configuration | Vertical fixed-angle rotor for microplates |
| Power Supply | 110–220 V, 50–60 Hz |
| Power Consumption | 20 W |
| Dimensions (W × D × H) | 210 × 190 × 190 mm |
| Weight | 3 kg |
| Compliance | CE-marked per IEC 61010-1 for laboratory equipment |
| Intended Use | Low-speed pelleting of liquids in standard microplates for molecular biology workflows |
| Brand | Hettich |
|---|---|
| Model | CT-40 |
| Type | Cryogenic Cold Trap |
| Cooling Method | Compressor-based refrigeration with R404a |
| Temperature Range | –40 °C to ambient |
| Temp. Control Accuracy | ±1 °C |
| Condensing Surface Area | 760 cm² |
| Max. Capture Capacity | 284 mL ethanol / 6 h (at –35 °C to –40 °C) |
| Water Capture | 260 mL / 12 h (at –15 °C) |
| Power Consumption | 320 W |
| Dimensions (W×D×H) | 580 × 250 × 560 mm |
| Weight | 53 kg |
| Electrical Supply | AC 220 V, 50 Hz, 15 A |
| Safety Features | Compressor overload protection, high-pressure cut-off, timed compressor rest cycle, auto-defrost function, temperature self-regulation |
| Collection Vessel Options | 300 mL or 600 mL borosilicate glass (chemical-resistant, wide-mouth, sealed) |
| Brand | Hettich |
|---|---|
| Model | DD5 |
| Centrifuge Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 500 mL |
| Acceleration/Deceleration | 10-step control |
| Timer Range | 1–99 min, continuous, or short-spin mode |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Motor | Brushless AC motor |
| Weight | 65 kg |
| Dimensions (L×W×H) | 630 × 500 × 420 mm |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Compliance | RoHS 2015/863 (silicone O-ring sealing) |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich DD5M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 0–5,000 rpm |
| Max RCF | 4,800 × g |
| Max Capacity | 6 × 500 mL (horizontal rotor) |
| Temperature Range | –20 °C to +40 °C |
| Refrigerant | R404a (non-ozone-depleting, RoHS-compliant) |
| Control Interface | TFT-LCD touchscreen + physical keys |
| Language Support | English, Chinese, Russian, Portuguese |
| Safety Certifications | CFDA Registered & Licensed, ISO 9001:2015, ISO 13485:2016 |
| Drive System | AC brushless motor with Infineon driver module and custom control board |
| Vibration Damping | Triple-stage damping + composite shock absorption |
| Door Lock | Electromechanical silent latch with auto-engagement |
| Acceleration/Deceleration | 10-step programmable |
| User Programs | 20 stored protocols |
| Chamber Material | AISI 304 stainless steel |
| External Casing | Powder-coated steel with reinforced front panel and triple-layer safety housing |
| Rotor Seal | Integrated silicone gasket (EU RoHS 2015/863 compliant) |
| Pre-cooling & Hold Cooling | Yes |
| Defrost Function | Electric heating defrost |
| Dimensions (W×D×H) | 740 × 620 × 900 mm |
| Net Weight | Approx. 125 kg |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Hettich DD5M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Category | Low-Speed Centrifuge (≤ 5,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Max Capacity | 6 × 500 mL |
| Max Speed | 5,000 rpm |
| Max RCF | 4,800 × g |
| Dimensions (W×D×H) | 740 × 620 × 900 mm |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R404a (non-ozone-depleting, RoHS-compliant) |
| Drive System | AC Brushless Frequency-Controlled Motor |
| Control Interface | TFT-LCD True-Color Touchscreen + Physical Keypad |
| Language Support | English, Chinese, Russian, Portuguese |
| Safety Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registered Device |
| Rotor Seal | Integrated Silicone Rubber Gasket (EU RoHS 2015/863 Compliant) |
| Chamber Material | AISI 304 Stainless Steel |
| Door Lock | Electromechanical Interlocked Lid with Auto-Engagement |
| Acceleration/Deceleration | 10-Step Programmable Ramp Control |
| User Programs | 20 Storage Slots |
| Vibration Damping | Triple-Stage Composite Damping System |
| Additional Features | Pre-cooling, Hold-at-Temperature Standby Mode, Defrost Heating, Real-Time Parameter Adjustment During Run, RCF Display Key, Audible & Visual Alarms for Overspeed, Overtemperature, Imbalance, Under/Over Voltage |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | EBA 270 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4,000 rpm |
| Max RCF | 2,254 × g |
| Max Capacity | 6 × 15 mL |
| Dimensions (H×W×D) | 239 × 326 × 389 mm |
| Weight | 14 kg |
| Power Supply | 200–240 V, 50–60 Hz |
| Power Consumption | 130 VA |
| Electromagnetic Compatibility | EN/IEC 61326-1 Class B |
| Timer Range | 1–99 min, ∞ (continuous), and short-spin mode |
| Safety Certification | Compliant with IEC 61010-1 for laboratory equipment |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | EBA200 / EBA200S |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 6,000 min⁻¹ (EBA200) / 8,000 min⁻¹ (EBA200S) |
| Max RCF | 3,461 × g (EBA200) / 6,153 × g (EBA200S) |
| Max Capacity | 8 × 15 mL |
| Dimensions (H×W×D) | 228 × 261 × 353 mm |
| Weight | 9 kg (EBA200) / 11 kg (EBA200S) |
| Power Supply | 200–240 V, 50–60 Hz |
| Power Consumption | 100 VA (EBA200) / 160 VA (EBA200S) |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Timer Range | 1–99 min, ∞ (continuous), and short-spin mode |
| Rotor Type | Fixed-angle rotor (8-place, 15 mL) |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | EBA280 |
| Type | Benchtop Centrifuge |
| Maximum Speed | 6000 min⁻¹ |
| Maximum RCF | 4146 × g |
| Maximum Capacity | 6 × 50 mL |
| Dimensions (H×W×D) | 242 × 326 × 400 mm |
| Weight | 12 kg |
| Power Supply | 200–240 V, 50–60 Hz |
| Power Consumption | 185 VA |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Timer Range | 1 s to 99 min 59 s + ∞ (continuous) + short-spin mode |
| Brand | Hettich |
|---|---|
| Country of Origin | Germany |
| Model | HAEMATOKRIT 200 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 13,000 rpm (max) |
| RCF | 16,060 × g |
| Capacity | 24 × capillaries |
| Dimensions (H×W×D) | 228 × 261 × 353 mm |
| Weight | 10 kg |
| Rotor Configuration | Horizontal swing-out rotor with integrated hematocrit reader |
| Safety Design | Segmented chamber rotor with individual capillary compartments |
| Compliance | CE, IEC 61010-1, ISO 13485 (medical device manufacturing environment) |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | HettCube 200 / 400 / 600 (R) |
| Temperature Range | 0 °C to +65 °C |
| Chamber Volume | 200 L / 400 L / 600 L (max. validated volume: 351 L for HettCube 600) |
| Capacity | up to 1800 Petri dishes (HettCube 600) |
| Compliance | Designed for ISO 13485-aligned environments, supports GLP/GMP documentation workflows |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Hettich HR/T16M |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (High-Speed) |
| Function | General-Purpose Refrigerated Centrifugation |
| Configuration | Fixed-Angle Rotor System |
| Max Capacity | 4 × 100 mL |
| Max Speed | 16,000 rpm |
| Max RCF | 19,600 × g |
| Dimensions (L×W×H) | 710 × 630 × 350 mm |
| Refrigeration | R404a refrigerant with imported hermetic compressor |
| Temp Range | −20 °C to +40 °C |
| Temp Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 1.5 kW |
| Weight | 73 kg |
| Certifications | CFDA Registration & Manufacturing License, ISO 9001:2015, ISO 13485:2016 |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich HR/T16M |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | General-Purpose Refrigerated Centrifugation |
| Configuration | Fixed-Angle Rotor System |
| Max Capacity | 4 × 100 mL |
| Max Speed | 16,000 rpm |
| Max RCF | 19,600 × g |
| Dimensions | 710 × 630 × 350 mm |
| Refrigeration | R404a refrigerant with imported non-CFC compressor |
| Temp Range | −20 °C to +40 °C |
| Temp Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 1.5 kW |
| Weight | 73 kg |
| Certifications | CFDA Registered & Manufactured, ISO 9001:2015, ISO 13485:2016 |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HR/T16MM |
| Instrument Type | Benchtop High-Speed Refrigerated Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Function | Refrigerated Centrifugation |
| Configuration | Fixed-Angle Rotor |
| Max Capacity | 24 × 1.5 mL |
| Max Speed | 16,500 rpm |
| Max RCF | 22,500 × g |
| Dimensions (L×W×H) | 680 × 350 × 300 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Certifications | CFDA Registered, ISO 9001:2015 & ISO 13485:2016 Certified |
| Rotor Material | Forged Aluminum Alloy |
| Rotor Compatibility | 0.2–2.0 mL tubes, PCR strip tubes |
| Display | TFT-LCD with Touch + Keypad Dual Interface |
| Safety Features | Biocontainment rotor seal (RoHS 2015/863 compliant), triple-damping suspension, automatic door lock, imbalance/over-speed/over-temp/under-voltage protection |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HR/T20M |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | General-Purpose Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Max Capacity | 4 × 100 mL |
| Max Speed | 20,000 rpm |
| Max RCF | 28,800 × g |
| Dimensions | 710 × 630 × 350 mm |
| Refrigeration System | Imported non-CFC compressor with R404a refrigerant |
| Temp Range | −20 °C to +40 °C |
| Temp Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 1.5 kW |
| Weight | 73 kg |
| Certifications | CFDA Registration & Manufacturing License, ISO 9001:2015, ISO 13485:2016 |
| Compliance | RoHS 2015/863 (silicone rubber rotor seals) |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | HR/T20MM |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 10,000–30,000 rpm |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor System |
| Maximum Capacity | 4 × 750 mL |
| Maximum Speed | 21,000 rpm |
| Maximum RCF | 31,750 × g |
| Dimensions (L×W×H) | 710 × 560 × 770 mm |
| Temperature Range | −20 °C to +40 °C |
| Temperature Accuracy | ±1 °C |
| Acceleration/Deceleration Rates | 10 programmable profiles |
| Preset Programs | 35 user-definable protocols |
| Rotor Autoidentification | Yes |
| Noise Level | ≤65 dB(A) |
| Power Supply | 2.0 kW |
| Timer Range | 0–99 h 59 min |
| Rotor Sterilization | Autoclavable at 121 °C (20 min) |
| Certifications | CE, ISO 13485, ISO 9001, IEC 61010-2-020 |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich HR20M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 10,000–30,000 rpm (High-Speed) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Max Capacity | 6 × 500 mL |
| Max Speed | 20,000 rpm |
| Max RCF | 48,745 × g |
| Dimensions | 840 × 730 × 960 mm |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R404a (non-ozone-depleting, EPA SNAP-approved) |
| Control System | Mitsubishi PLC (compliant with EU EMC Directive 2014/30/EU & IEC 61131-2:2007), Weintek HMI (NEMA 4-rated, CE-certified) |
| Safety Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registration & Manufacturing License |
| Rotor Material | Aerospace-grade forged aluminum (angle rotors only) |
| Sealing | Integrated silicone O-ring (RoHS 2015/863 compliant) |
| Drive | High-torque AC frequency-controlled motor |
| Braking | 10-step programmable deceleration |
| Acceleration | 10-step programmable acceleration |
| Programs | 16 user-defined protocols |
| Data Display | Real-time curves for speed ramping, RCF integration, and temperature profiling |
| Structural Integrity | Triple-damping system, stainless-steel centrifuge chamber, three-layer steel safety housing, mechanical door interlock |
| Mobility | Dual-position casters with leveling feet |
| Brand | Hettich |
|---|---|
| Model | LR10M |
| Type | Floor-standing refrigerated centrifuge |
| Max. Capacity | 6 × 1000 mL |
| Max. Speed | 10,000 rpm |
| Max. RCF | 15,875 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Programmable Methods | 16 user-defined protocols |
| Dimensions (W×D×H) | 840 × 730 × 950 mm |
| Weight | 280 kg |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 5.7 kW |
| Noise Level | <65 dB(A) |
| Refrigerant | R404a (non-CFC) |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LR5M Mobile Blood Collection Vehicle Refrigerated Centrifuge |
| Instrument Type | Floor-standing Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2620 × g |
| Max Capacity | 12 × 5 mL (vacutainer & nucleic acid tubes) |
| Refrigeration System | R404a eco-friendly refrigerant with brushless DC compressor |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±2 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 0 min – 99 h 59 min (continuous & short-spin modes) |
| Drive System | High-torque brushless DC motor with microprocessor control |
| Power Supply | AC 220 V, 50 Hz |
| Total Power Consumption | 0.6 kW |
| Net Weight | 52.5 kg |
| Dimensions (L×W×H) | 340 × 562 × 396 mm |
| Foot Design | Vacuum suction base for vehicle-mounted stability |
| Compliance | Designed for ISO 13485-aligned blood collection workflows |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Hettich LR6M |
| Instrument Type | Floor-standing Centrifuge |
| Speed Class | Low-speed Centrifuge (≤ 6,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Separation Level | Cell & Bacterial Pelletization |
| Max Capacity | 6 × 1000 mL |
| Max Speed | 4200 rpm |
| Max RCF | 5167 × g |
| Dimensions (W×D×H) | 840 × 730 × 950 mm |
| Weight | 270 kg |
| Power Supply | AC 220 V / 50 Hz |
| Total Power | 4.0 kW |
| Noise Level | <65 dB(A) |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Timer Range | 1 min – 99 h 59 min |
| Speed Accuracy | ±50 rpm |
| Acceleration/Deceleration | 10-step programmable |
| Programmable Methods | 16 user-defined protocols |
| Display | TFT-LCD color touchscreen with multilingual UI (EN/CN) |
| Safety Certifications | CFDA registration & manufacturing license, ISO 9001:2015, ISO 13485:2016 |
| Compliance | EU EMC Directive 2014/30/EU, IEC 61131-2:2007, NEMA 4-rated HMI, CE-marked electrical system |
| Refrigerant | R404a (non-CFC, ozone-friendly) |
| Rotor Locking | Mechanical interlocked lid |
| Chassis | AISI 304 stainless steel chamber, powder-coated steel housing, triple-layer reinforced front panel |
| Mobility | Integrated casters with leveling feet |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LR6M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Category | Low-Speed Centrifuge (≤6,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor |
| Separation Class | Cell & Bacterial Pelletization |
| Max Capacity | 6 × 1000 mL |
| Max Speed | 4200 rpm |
| Max RCF | 5167 × g |
| Dimensions | 840 × 730 × 950 mm |
| Weight | 270 kg |
| Power Supply | AC 220 V / 50 Hz |
| Total Power | 4.0 kW |
| Noise Level | <65 dB(A) |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Timer Range | 1 min – 99 h 59 min |
| Speed Accuracy | ±50 rpm |
| Refrigerant | R404a (non-CFC, ozone-friendly) |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA Registered & Certified |
| Control System | Mitsubishi PLC (IEC 61131-2:2007, EU EMC Directive 2014/30/EU), Weintek HMI (NEMA 4, CE certified) |
| Rotor Material | Austenitic 304 Stainless Steel Chamber |
| Safety | Mechanical door lock, triple-layer steel protection housing, imbalance detection, over-speed/over-temp/under-voltage/over-pressure alarms, auto-balance compensation, active vibration damping |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich LR8M |
| Instrument Type | Floor-standing Centrifuge |
| Speed Range | Up to 8,000 rpm |
| Rotor Configuration | Horizontal Swing-out Rotor (6 × 1000 mL) |
| Max Capacity | 6 × 1000 mL |
| Max RCF | 11,377 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Programmable Methods | 16 user-defined protocols |
| Drive System | High-torque AC frequency-controlled motor |
| Refrigeration | CFC-free R404a compressor system |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Dimensions (W×D×H) | 840 × 730 × 950 mm |
| Weight | 270 kg |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V / 50 Hz |
| Total Power Consumption | 4.0 kW |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | Mikro 185 |
| Instrument Type | Benchtop Centrifuge |
| Function | General-Purpose Microcentrifuge |
| Configuration | Fixed-Angle Rotor |
| Maximum Capacity | 24 × 1.5/2.0 mL |
| Maximum Speed | 14,000 rpm |
| Maximum RCF | 18,845 × g |
| Dimensions (H×W×D) | 261 × 353 × 238 mm |
| Weight | 11 kg |
| Power Supply | 200–240 V, 50–60 Hz |
| Power Consumption | 330 VA |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Timer Range | 1–99 min, ∞ (continuous), and short-spin mode |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | Mikro 185 |
| Centrifuge Type | Benchtop Microcentrifuge |
| Speed Range | Up to 14,000 min⁻¹ |
| Max RCF | 18,845 × g |
| Max Capacity | 24 × 1.5 / 2.0 mL tubes |
| Dimensions (W × D × H) | 228 × 262 × 352 mm |
| Rotor Options | 4 interchangeable rotors |
| Display | LCD with real-time RPM/RCF readout |
| Safety Features | Automatic imbalance shutdown, rotor auto-recognition, emergency lid release, instant centrifugation button |
| Compliance | IEC 61010-1, EN 61326-1, CE-marked for laboratory use |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | MIKRO 200 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 15,000 rpm |
| Max RCF | 21,382 × g |
| Max Capacity | 30 × 1.5/2.0 mL |
| Dimensions (H×W×D) | 260 × 275 × 344 mm |
| Weight | ~11.5 kg |
| Cooling | Ventilated (non-refrigerated) |
| Rotor Types | Fixed-angle rotors (24–30 position), including 24×2.0 mL (40°/45°), 30×2.0 mL (dual-row, 40°/52.5°), 20×2.0 mL cryotube rotor, and 4×0.2 mL PCR strip rotor |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | MIKRO 200R |
| Centrifuge Type | Benchtop Refrigerated Microcentrifuge |
| Max Speed | 15,000 rpm |
| Max RCF | 21,382 × g |
| Max Capacity | 30 × 1.5 mL / 2.0 mL tubes |
| Temperature Range | –10 °C to +40 °C (infinitely adjustable) |
| Dimensions (H×W×D) | 260 × 281 × 547 mm |
| Weight | 28 kg |
| Power Supply | 200–240 V, 50 Hz, 450 VA |
| Compliance | EN/IEC 61326-1 Class B |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | MIKRO 220 / MIKRO 220R |
| Type | Benchtop Centrifuge |
| Speed Range | 0–18,000 rpm |
| Max RCF | 31,514 × g |
| Max Capacity | 48 × 1.5 mL / 2.0 mL (angular rotor) or 60 × 1.5 mL / 2.0 mL (swing-bucket rotor) |
| Temperature Range (MIKRO 220R) | –20 °C to +40 °C |
| Dimensions (W × D × H) | 330 mm × 420 mm × 313 mm (MIKRO 220), 330 mm × 650 mm × 313 mm (MIKRO 220R) |
| Weight | 21 kg (MIKRO 220), 42 kg (MIKRO 220R) |
| Power Input | 200–240 V, 50–60 Hz |
| Compliance | EN/IEC 61326-1 Class B |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTANTA 460 / ROTANTA 460R |
| Type | Benchtop Centrifuge |
| Speed Range | 15,000 min⁻¹ |
| Max RCF | 24,400 × g |
| Max Capacity | 4 × 1000 mL |
| Dimensions (H×W×D) | ROTANTA 460: 456 × 554 × 706 mm |
| ROTANTA 460R | 456 × 770 × 706 mm |
| Weight | 101 kg / 141 kg |
| Power Supply | 200–240 V, 1~ |
| Power Consumption | 1000 VA (460) / 1800 VA (460R) |
| EMC Compliance | EN/IEC 61326-1 Class B |
| Timer Range | 1 sec – 99 h 59 min 59 sec + ∞ / pulse mode |
| Rotor Recognition | Automatic |
| Safety Features | Lid interlock with emergency release, imbalance detection & auto-shutdown, large transparent lid window, no external safety hood required |