| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTINA 380 / ROTINA 380R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 15,000 min⁻¹ |
| Max RCF | 24,400 × g |
| Max Capacity | 4 × 290 mL (swing bucket) |
| Temperature Range (ROTINA 380R only) | −20 °C to +40 °C |
| Dimensions (ROTINA 380) | 418 × 457 × 600 mm (H × W × D) |
| Dimensions (ROTINA 380R) | 260 × 281 × 547 mm (H × W × D) |
| Weight (ROTINA 380) | 58.5 kg |
| Weight (ROTINA 380R) | 88.5 kg |
| Power Supply | 200–240 V, 1~, 50–60 Hz |
| Power Consumption | 650 VA (ROTINA 380), 1300 VA (ROTINA 380R) |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Safety Compliance | IEC 61010-2-020, EN 61326-1 |
| Programmable Methods | 98 user-defined protocols |
| Rotor Recognition | Automatic |
| Unbalance Detection | Real-time electronic monitoring |
| Emergency Lid Release | Yes |
| Refrigeration | Compressor-based (ROTINA 380R only) |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTINA 380 |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Max Capacity (Horizontal Rotor) | 4 × 290 mL |
| Max Capacity (Fixed-Angle Rotor) | 6 × 94 mL or 30 × 2.0 mL |
| Max Speed | 15,000 rpm |
| Max RCF | 24,400 × g |
| Dimensions (H×W×D) | 418 × 457 × 600 mm |
| Weight | ~51 kg |
| Cooling Type | Ventilated (Non-refrigerated) |
| Rotor Compatibility | Fixed-angle, horizontal, slide, and drum rotors |
| Application Class | Biomolecular separation (nucleic acids, proteins, organelles) |
| Key Rotors | 30-place 2.0 mL fixed-angle rotor (Cat. No. 1789-A, 24,400 × g), 4-place 290 mL horizontal rotor (Cat. No. 1754, 4,863 × g), 6-place 94 mL fixed-angle rotor (Cat. No. 1792, 16,504 × g), 8-place microscope slide rotor (Cat. No. 1748, 2,415 × g) |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop Centrifuge |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Max Capacity | 4 × 600 mL |
| Max Speed | 15,000 rpm |
| Max RCF | 24,400 × g |
| Temperature Range | –20 °C to +40 °C (adjustable in 0.1 °C increments) |
| Dimensions (H×W×D) | 423 × 713 × 654 mm |
| Weight | 117 kg (ROTINA 420R) |
| Safety Compliance | EN/IEC 61326-1 Class B, EN 61010-1, IEC 61010-2-020 |
| Programmability | 99 user-defined protocols with recall function |
| Cooling | Active refrigeration with standby cooling |
| Rotor Recognition | Automatic detection via RFID or mechanical coding |
| Unbalance Protection | Real-time dynamic imbalance sensing and automatic shutdown |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTINA 420R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 100–15,000 min⁻¹ |
| Max RCF | 24,400 × g |
| Max Capacity | 4 × 600 mL |
| Temperature Range | –20 °C to +40 °C (adjustable in 0.1 °C increments) |
| Dimensions (W × D × H) | 713 × 654 × 423 mm |
| Weight | 117 kg |
| Power Supply | 200–240 V, 1~, 50–60 Hz |
| Max Power Consumption | 1600 VA |
| Safety Certifications | ISO 9001, ISO 13485/MDSAP, ISO 14001, EC Declaration of Conformity, Biosafety Lid Certificate (Zertifikat_1752) |
| Electromagnetic Compatibility | EN/IEC 61326-1 Class B |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTIXA 500 RS |
| Instrument Type | Floor-standing Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 11,500 rpm) |
| Max. Capacity | 4 × 1000 mL |
| Max. RCF | 18,038 × g |
| Dimensions (W×D×H) | 814 × 973 × 650 mm |
| Weight | 219 kg |
| Temperature Range | –20 °C to +40 °C (continuously adjustable) |
| Acceleration/Deceleration | Ultra-fast ramp profiles |
| Control Interface | RS232 port for PC connectivity (up to 29 units per host), 89 programmable protocols |
| Motor | Frequency-controlled brushless DC motor |
| Compliance | EN/IEC 61326-1 Class B (EMC), UVV-compliant maintenance design |
| Power Supply | 230–240 V, 50–60 Hz, 3800 VA |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTIXA 500 RS |
| Type | Floor-standing refrigerated centrifuge |
| Speed Range | Up to 10,000 rpm |
| Max RCF | 17,441 × g |
| Max Capacity | 4 × 1000 mL (horizontal rotor) |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (H×W×D) | 973 × 650 × 814 mm |
| Weight | ~172 kg |
| Rotor Compatibility | Multiple horizontal and angular rotors including 4×1000 mL (RCF 5,252), 6×250 mL (RCF 3,631), 2×microplate (RCF 2,652), ASTM bottle rotor (RCF 984), Schlenk bottle rotor (RCF 805) |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTIXA 500 RS |
| Type | Floor-standing Refrigerated Centrifuge |
| Max Speed | 11,500 rpm |
| Max RCF | 18,038 × g |
| Max Capacity | 4 × 1000 mL (horizontal rotor) |
| Temperature Range | −20 °C to +40 °C |
| Dimensions (W×D×H) | 650 × 814 × 973 mm |
| Weight | ~219 kg |
| Noise Level | 58 dB(A) |
| Power Supply | 230–240 V, 1~ |
| Power Consumption | 3,800 VA |
| EMC Compliance | EN/IEC 61326-1, Class B |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTO SILENTA 630 RS |
| Instrument Type | Floor-standing Centrifuge |
| Speed Range | 100–6,000 min⁻¹ |
| Max. RCF | 6,520 × g |
| Max. Capacity | 6 × 2,000 mL |
| Temperature Range | −20 °C to +40 °C |
| Dimensions (H×W×D) | 973 × 813 × 1015 mm |
| Weight | 355 kg |
| Power Supply | 400 V, 3~ + N, 50–60 Hz |
| Max. Power Consumption | 9,700 VA |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Programmable Methods | 89 stored protocols |
| Communication Interface | RS232 |
| Continuous Operation Mode | Yes |
| Rotor Auto-recognition | Yes |
| Safety Certifications | IEC 61010-2-020, EN 61326-1 |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTOFIX 32A |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–6000 rpm |
| Max RCF | 4226 × g |
| Max Capacity | 4 × 100 mL or 32 × 15 mL |
| Dimensions (H×W×D) | 257 × 366 × 430 mm |
| Weight | 23 kg |
| Power Supply | 208–240 V, 50–60 Hz |
| Power Consumption | 300 VA |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Timer Range | 1 s to 99 min 59 s, continuous mode (∞), and short-spin mode |
| Rotor Recognition | Automatic |
| Safety Features | Lid interlock, anti-slip lid latch, imbalance detection, emergency lid release |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Instrument Type | Benchtop Centrifuge |
| Category | Low-Speed Centrifuge |
| Max. Speed | 4000 min⁻¹ (ROTOFIX 46) / 2000 min⁻¹ (ROTOFIX 46H) |
| Max. RCF | 3095 × g (ROTOFIX 46) / 984 × g (ROTOFIX 46H) |
| Max. Capacity | 4 × 290 mL (ROTOFIX 46) / 4 × 100 mL (ROTOFIX 46H) |
| Temperature Range (ROTOFIX 46H only) | +10 °C to +90 °C, continuously adjustable |
| Dimensions (H×W×D) | 345 × 538 × 647 mm |
| Weight | 60 kg |
| Power Supply | 200–240 V, 50–60 Hz |
| Power Consumption | 460 VA (ROTOFIX 46) / 600 VA (ROTOFIX 46H) |
| Electromagnetic Compatibility | EN/IEC 61326-1, Class B |
| Programmable Methods | 10 stored protocols |
| Acceleration/Deceleration | 9 selectable ramp levels |
| Safety Features | Automatic lid lock & emergency release, lid support mechanism, rotor auto-recognition, imbalance detection, motor & chamber overheat protection |
| Rotor Options | 4 interchangeable rotors available |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTOLAVIT II |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–3,500 rpm |
| Max RCF | 1,438 × g |
| Rotor Radius | 105 mm |
| Capacity | 24 × standard tubes (10 × 75 mm or 12 × 75 mm) |
| Timer Range | 1 sec – 9 min 59 sec |
| Dimensions (H×W×D) | 330 × 480 × 280 mm |
| Power Supply | 200–240 V AC, 50–60 Hz |
| Compliance | IEC 61010-1, EN 61326-1, CE-marked for in vitro diagnostic use |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Hettich TDL5M |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–5500 rpm |
| Max RCF | 4800 × g |
| Max Capacity | 4 × 500 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤65 dB(A) |
| Dimensions (L×W×H) | 630 × 760 × 400 mm |
| Weight | 110 kg |
| Power Consumption | 1.8 kW |
| Timer Range | 1 min – 99 h 59 min |
| Drive System | High-torque AC brushless motor |
| Control Interface | TFT-LCD touchscreen + physical keys |
| Language Options | English, Chinese, Russian, Portuguese |
| Safety Certifications | CFDA Registered & Manufactured, ISO 9001:2015, ISO 13485:2016 |
| Rotor Compatibility | Horizontal swing-out rotors, bio-sealed angular rotors (RoHS 2015/863 compliant silicone gasket), PCR plates, microtiter plates, cell culture plates, deep-well plates |
| Cooling System | Imported CFC-free compressor with R404a refrigerant |
| Features | Pre-cooling, standby cooling, auto-defrost, imbalance detection, overspeed/overtemperature/under-voltage/over-voltage protection, triple-damping vibration isolation, electromechanical door lock |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TDL6M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Class | Low-Speed Centrifuge (max 6500 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Separation Target | Biological Macromolecules |
| Max Capacity | 4 × 500 mL |
| Max Speed | 6500 rpm |
| Max RCF | 4800 × g |
| Dimensions | 630 × 760 × 400 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Motor | High-Torque Brushless Frequency-Controlled AC Motor |
| Drive & Control | Microprocessor-Based Digital Control System |
| Acceleration/Deceleration | 10 Adjustable Ramp Profiles |
| Programmable Protocols | 20 Predefined & User-Editable Methods |
| Display | 4.3-inch TFT True-Color Touchscreen with Dual Touch/Keypad Interface |
| Data Logging | Automatic Run Parameter Recording (Time, Speed, RCF, Temp, Rotor ID) |
| Rotor Recognition | Manual Input (No Auto-ID Sensor) |
| Construction | Full Steel Frame with Stainless Steel Centrifuge Chamber |
| Door Lock | Electromechanical Quiet-Lock System |
| Weight | 110 kg |
| Rated Power | 1.8 kW |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich TDL8M |
| Instrument Type | Benchtop Centrifuge |
| Speed Class | Low-Speed Centrifuge (up to 8,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Max Capacity | 4 × 500 mL |
| Max Speed | 8,000 rpm |
| Max RCF | 6,460 × g |
| Dimensions (L×W×H) | 630 × 760 × 400 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp. Control Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤65 dB(A) |
| Power Consumption | 1.8 kW |
| Weight | 110 kg |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registered & Manufactured |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TDZ6-WS |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–6000 rpm |
| Max RCF | 4800 × g |
| Max Capacity | 4 × 100 mL |
| Rotor Configuration | Horizontal Swing-Out |
| Application Class | Cell & Bacterial Separation |
| Drive System | Brushless Frequency-Controlled Motor |
| Control Interface | TFT Color Touchscreen + Digital Display |
| Acceleration/Deceleration Profiles | 10 selectable ramps |
| Stored Programs | 20 user-defined protocols |
| Timer Range | 0–99 h 59 min, continuous, or momentary spin |
| Power Consumption | 500 W |
| Noise Level | ≤65 dB(A) |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Electrical Supply | AC 220 V, 50 Hz |
| Rotor Recognition | Visual on-screen rotor diagram display |
| Safety Features | Automatic imbalance detection, motorized safety door lock, stainless steel chamber, multi-stage vibration damping system |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TG16MW |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | General-Purpose Centrifugation |
| Configuration | Fixed-Angle Rotor |
| Max Capacity | 12 × 10 mL |
| Max Speed | 16,500 rpm |
| Max RCF | 19,600 × g |
| Dimensions (L×W×H) | 380 × 260 × 310 mm |
| Weight | 17 kg |
| Power Supply | AC 220 V, 50 Hz |
| Motor | Brushless Frequency-Controlled AC Motor |
| Control System | Microprocessor-Based with TFT Touchscreen |
| Noise Level | ≤60 dB(A) |
| Acceleration/Deceleration | 10 Programmable Ramp Profiles (Fastest: 30 s to full speed and 30 s to stop) |
| Timer Range | 1 min – 99 h 59 min |
| Stored Protocols | 20 User-Defined Programs |
| Rotor Compatibility | Standard Fixed-Angle Rotors for 1.5/2.0 mL, 5 mL, 7 mL, and 10 mL Tubes |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Hettich TL6R |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | Up to 6,500 rpm |
| Max RCF | 4,800 × g |
| Max Capacity | 4 × 750 mL (horizontal rotor) |
| Temperature Range | –20 °C to +40 °C |
| Refrigerant | R404a (non-ozone-depleting, RoHS-compliant) |
| Dimensions (W×D×H) | 710 × 560 × 770 mm |
| Display | TFT-LCD true-color touchscreen with physical keypad |
| Control | Dual-mode interface (touch + tactile), multi-language support (English, Chinese, Russian, Portuguese) |
| Safety Certifications | CFDA registered & licensed production, ISO 9001:2015 & ISO 13485:2016 certified |
| Rotor Compatibility | Sealed biocontainment angular and horizontal rotors with integrated silicone gasket (RoHS 2015/863 compliant) |
| Drive System | High-torque AC frequency-controlled motor with Infineon driver module and ELM microcontroller |
| Vibration Damping | Triple-stage damping system with composite shock absorption |
| Acceleration/Deceleration | 10 programmable ramp profiles each |
| User Programs | 20 stored protocols with real-time parameter adjustment during run |
| Door Lock | Electromechanical auto-locking mechanism with soft-close engagement |
| Additional Features | Pre-cooling, standby cooling, automatic defrost, imbalance detection, over-speed/over-temperature/under-voltage/over-voltage protection, level-adjustable casters |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | UNIVERSAL 320(R) |
| Type | Refrigerated Benchtop Centrifuge |
| Max Speed | 16,000 min⁻¹ |
| Max RCF | 24,900 × g |
| Max Capacity | 4 × 200 mL or 6 × 94 mL |
| Temperature Range (320R) | −20 °C to +40 °C |
| Dimensions (320) | 346 × 395 × 520 mm |
| Dimensions (320R) | 346 × 407 × 698 mm |
| Weight (320) | 31 kg |
| Weight (320R) | 52 kg |
| Acceleration/Deceleration | 9 programmable levels |
| Timer Range | 1 s to 99 min 59 s, continuous or short-spin mode |
| Power Supply | 200–240 V, 50–60 Hz (320) |
| Power Consumption | 400 VA (320), 800 VA (320R) |
| Compliance | EN/IEC 61326-1 Class B |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZLS-3 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 60 °C (heating optional) |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 6 × 250 mL |
| Maximum Rotational Speed | 2000 rpm |
| Maximum RCF | 500 × g |
| Vacuum Interface | φ10 mm |
| Ultimate Vacuum | 0.1 mbar (with compatible pump) |
| Timer Range | 1 min – 99 h 59 min |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Power Supply | AC 220 V / 50 Hz |
| Optional Accessories | CT-6 Cold Trap, 2×2×48-well Microplate Rotor, 50 mL & 20 mL Adapters |