JENCO
Filter
Showing all 9 results
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 3010M |
| Measurement Parameters | Conductivity, TDS, Salinity, Temperature |
| Portability | Handheld (Field-Portable) |
| Intended Use | Industrial Process Monitoring, Field Sampling, Lab Bench Support |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Temperature Range | 10–110 °C |
| Accuracy | ±0.5% of Full Scale |
| Minimum Resolution | 0.001 µS/cm |
| Electrode Constant Options | 0.1, 1.0, 10.0 cm⁻¹ |
| Temperature Compensation | Automatic (NTC 30 kΩ) |
| Enclosure Rating | IP67 (Waterproof) |
| Data Retention | Non-volatile memory retains calibration and settings after power loss |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 3173/3173R |
| Detection Parameter | Conductivity Only (Multi-Parameter Output) |
| Portability | Benchtop |
| Application Environment | Industrial Process Monitoring & Laboratory QC |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Temperature Range | 10–110 °C |
| Accuracy | ±0.5% of Full Scale |
| Minimum Resolution | 0.001 µS/cm |
| Auto Temperature Compensation | Yes |
| Power Supply | AC/DC Dual Mode |
| Data Interface | RS-232C (3173R only) |
| Memory | Calibration Value Retention After Power Loss |
| Display | Large LCD with Multi-Parameter Simultaneous Readout |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 3675 |
| pH Range | -2.00 to 14.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.05 pH |
| Temperature Compensation | Automatic, 0–100 °C |
| Dimensions | 96 × 48 × 172 mm |
| Weight | 0.45 kg |
| Output | Isolated 4–20 mA |
| Relay Outputs | 2 programmable relays |
| Display | LCD |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 6010M |
| Measurement Range | pH: –2.00 to 16.00 |
| ORP | –2000 to +2000 mV |
| Temperature | –10.0 to 130.0 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH |
| Dimensions | 186 × 70 × 37 mm |
| Weight | 0.26 kg |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model Series | 610 / 620D / 650 |
| Measurement Range | 0.0–14.0 pH, ±999 mV (620D & 650) |
| Resolution | 0.1 pH (all models), 1 mV (620D & 650) |
| Accuracy | ±0.2 pH (610), ±0.1 pH (620D), ±0.2% ±1 mV (620D & 650) |
| Automatic Temperature Compensation (ATC) | 0–60 °C (620D only) |
| Calibration | Single-point (610 & 650), Two-point (620D) |
| Operating Temperature | 0–50 °C |
| Battery Life | ~1000 h (610), ~400 h (620D & 650) |
| Power | 4 × 1.5 V button cells (LR44 or equivalent) |
| Dimensions | 150 × 32 × 15 mm (L × W × H) |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 6173 / 6173R |
| pH Range | –6.00 to 20.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH |
| ORP Range | –2000 to +2000 mV |
| ORP Resolution | 1 mV |
| ORP Accuracy | ±0.05% FS |
| Temperature Range | –10.0 to 120.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration Points | 2-point (user-selectable buffers: 4.01/7.00/10.01 or 4.00/6.86/9.18) |
| Temperature Compensation | Automatic or Manual (–10.0 to 120.0 °C) |
| Electrode Slope Compensation | ±30% |
| Zero Offset Compensation | ±90 mV at pH 7.00/6.86 |
| Endpoint Detection & Hold Function | Yes |
| Data Storage | Calibration history retained |
| Communication Interface | RS-232C (6173R only) |
| Power Supply | 6 × AA batteries (1.5 V) or optional AC adapter |
| Dimensions | 230 × 165 × 80 mm |
| Weight | ~650 g (battery-free) |
| Environmental Rating | 0–50 °C, <95% RH non-condensing |
| Certifications | CE compliant |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | JENCO 6219 |
| pH Range | -2.000–16.000 pH |
| pH Resolution | 0.01/0.001 pH |
| pH Accuracy | ±0.1% of full scale ±1 digit |
| ORP Range | -1999.9–1999.9 mV |
| ORP Resolution | 1/0.1 mV |
| ORP Accuracy | ±0.1% of full scale ±1 digit |
| Ion Concentration Range | 0.0–119.8 conc. |
| Ion Resolution | 0.05/0.1 |
| Ion Accuracy | ±2 digits |
| Temperature Range | -5.0–125.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Input Impedance | >10¹³ Ω |
| Temperature Sensor | 10 kΩ thermistor (25 °C) |
| Calibration | Auto two-point with standard buffers (pH 4.00, 6.86, 9.18) |
| Endpoint Detection & Hold Function | Yes |
| Data Storage | Calibration history and settings |
| Communication Interface | RS-232C |
| Power Supply | AC adapter (DC 9 V output) or 6 × AA batteries |
| Dimensions | 250 × 240 × 100 mm |
| Weight | 1.07 kg (including batteries) |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 6309PDT |
| Channel Count | Single-Channel |
| Dimensions | 96 × 96 × 148 mm |
| Enclosure Rating | IP65 |
| Power Supply | 230 VAC, 50/60 Hz |
| Output | Isolated 4–20 mA (reversible), Relay Control (2.5 A / 230 VAC) |
| Weight | 960 g |
| Mounting | 1/4 DIN panel mount (cutout: 92 × 92 mm) |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | JENCO Industrial Online pH Transmitter Series 691/692 |
| Measurement Range | pH: –2.00 to 16.00 |
| ORP | –2000 to +2000 mV |
| Temperature | –10.0 to 130.0 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH |
| Dimensions | 96 × 48 × 167 mm |