| Brand | KDF |
|---|---|
| Origin | Japan |
| Model | KDF-007EX |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1100 °C |
| Heating Method | Resistance Wire Heating |
| Internal Dimensions | 120 (W) × 110 (H) × 220 (D) mm |
| Maximum Power | 1800 W |
| Ramp Time to 1100 °C (empty chamber) | 25 min |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Standby Power Consumption | ~1.8 W |
| Net Weight | 18 kg |
| Operating Ambient | 10–40 °C, 30–90% RH |
| Thermocouple Type | JIS Class K |
| Programmable Profiles | 10 stored programs |
| Temperature Ramp Rate | 1–20 °C/min (adjustable in 1 °C/min increments) |
| Soak Duration | Up to 99 h 50 min (10-min resolution for long holds) |
| Alarm Options | Adjustable audible alert (High/Medium/Low volume or OFF) |
| Brand | KDF |
|---|---|
| Origin | Japan |
| Model | KDF-009G / KDF-009GS |
| Instrument Type | Box-Type Muffle Furnace |
| Max Operating Temperature | 1230 °C |
| Max Power Consumption | 4000 W |
| Heating Rate | Adjustable from 0.1 to 30 °C/min (in 1 °C increments) |
| Internal Chamber Dimensions | 250 (W) × 180 (H) × 280 (D) mm |
| External Dimensions | 470 (W) × 600 (H) × 485 (D) mm |
| Weight | 51 kg |
| Heating Element Material | Kanthal® A1 Alloy |
| Temperature Sensor | Type R Thermocouple |
| Programmable Steps | Up to 10 independent multi-segment programs |
| Timer Range | 0–99 h 59 min |
| Ambient Atmosphere Options | Air (KDF-009G) or Controlled Gas (N₂, Ar, etc. |
| Safety Monitoring | Overtemperature, heater open-circuit, thermocouple break, memory corruption, and system fault detection |
| Brand | KDF |
|---|---|
| Origin | Japan |
| Model | KDF-1700 |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1700 °C |
| Usable Temperature Range | 600–1700 °C |
| Typical Operating Temperature | 1600 °C |
| Heating Rate (RT → 1700 °C) | 65 min (no casting ring, 50 Hz) |
| Rated Power | 6 kW |
| Chamber Dimensions | 200 (W) × 230 (H) × 260 (D) mm |
| External Dimensions | 560 (W) × 830 (H) × 630 (D) mm |
| Heating Element | 10 rods of Molybdenum Disilicide (MoSi₂), rated to 1800 °C |
| Insulation | Ceramic Fiber |
| Temperature Control | PID with 3 preset PID parameter sets |
| Thermocouple Type | JIS Class B (B-type, 400–1800 °C) |
| Programmable Steps | 19 programs, up to 30 segments per program |
| Safety Systems | Door interlock, leakage current breaker, over-temperature protection, thermal fuse, auto-cooling fan shutdown, thermocouple/open-heater fault detection, abnormal temperature rise monitoring |
| Output Options | 5-channel programmable event outputs, alarm contact outputs, start/stop control terminals, momentary power-loss recovery, relay contact outputs |
| Optional Accessories | Temperature recorder (100-mm chart width), gas introduction unit with programmable electromagnetic flowmeter (gas type & flow rate customizable), 20-mm socket holder (KDW-200) |
| Brand | KDF |
|---|---|
| Origin | Japan |
| Model | KDF008EX |
| Furnace Type | Box-Type Muffle Furnace |
| Max Temperature | 1100 °C |
| Max Power | 1800 W |
| Heating Rate (to 1100 °C) | 29 min (empty chamber) |
| Internal Dimensions | 180 (W) × 155 (H) × 250 (D) mm |
| Heating Element | Resistance Wire |
| Voltage | AC 200–240 V ±10%, 50/60 Hz |
| Power Consumption | 3.0 kVA |
| Standby Power | 1.8 VA |
| Weight | 35 kg |
| Thermocouple Type | JIS Class K |
| Operating Ambient | 10–40 °C, 30–90% RH |
| Programmable Profiles | 10 |
| Temperature Ramp Stages | Up to 3 per program |
| Ramp Rate Range | 1–20 °C/min (L/M/H selectable), or full-range ramp (0–1100 °C/min) |
| Soak Duration | 0–9 h 59 min (1 min increment) / 0–99 h 50 min (10 min increment) |
| Timer Resolution | 10 min |
| Audible Alert | Adjustable volume (High/Medium/Low/OFF) |
| Brand | KDF |
|---|---|
| Origin | Japan |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1100 °C |
| Temperature Control Accuracy | ±3 °C at 1000 °C |
| Rated Power | 8.0 kW |
| Heating Rate to Max Temp | 49 min |
| Heating Method | Resistance Wire Heating |
| Internal Chamber Dimensions | 350 × 300 × 500 mm (W × H × D) |
| Chamber Volume | 52.5 L |
| Temperature Resolution | 0.5 °C |
| Temperature Uniformity | ±3 °C at 1000 °C |
| Insulation Material | Ceramic Fiber |
| Thermocouple Type | JIS K (Chromel–Alumel) |
| Heating Element | Kanthal AF (Fe–23% Cr–6% Al) |
| Gas Inlet Option | Standard N₂ supply (20 L/min for P100G model) |
| Programmable Steps | 40 programs / 20 categories |
| Control Algorithm | Multi-zone PID with auto-tuning capability |
| Communication Interface | RS-232C (D-sub 25-pin female), baud rates: 1200–9600 bps |
| Safety Systems | Overtemperature cut-off, thermal fuse, current overload breaker, rear-panel temperature sensor, microcomputer fault detection (heater open, thermocouple break, memory error, ramp overshoot) |
| Brand | KDF |
|---|---|
| Origin | Japan |
| Instrument Type | Box-Type Muffle Furnace |
| Maximum Temperature | 1100 °C |
| Temperature Control Accuracy | ±3 °C at 1000 °C |
| Rated Power | 8.0 kW |
| Heating Rate to Max Temp | 49 min |
| Heating Method | Resistance Wire Heating |
| Internal Chamber Dimensions (W×H×D) | 350 mm × 300 mm × 500 mm |
| Chamber Volume | 52.5 L |
| Temperature Control | PID with Auto-Tuning |
| Programmable Steps | 9 Presets (up to 4 combinable as “Casting Ring” sequences) |
| Gas Inlet Option | Standard N₂ flow (20 L/min for S100G model) |
| Safety Systems | Dual Thermocouple Monitoring, Over-Temperature Cut-off, Fan-Activated Cooling, Current Overload Protection, Microcontroller Self-Diagnostic |