Koehler
Filter
Showing 91–95 of 95 results
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K95300 |
| Pressure Range | 0–3000 mBar |
| Pressure Resolution | <1 mBar |
| Temperature Range | Ambient to –50 °C |
| Temperature Resolution | <1 °C |
| Control System | Integrated Touchscreen PLC |
| Data Interface | Ethernet |
| Air Pressure Source | Internal Compressor |
| Power Supply | 110/230 V, 50–60 Hz |
| Dimensions (W×D×H) | 230 × 320 × 440 mm |
| Weight | 25 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K95400 |
| Product Type | Laboratory Instrument |
| Test Parameter | Grease Bleedability (Penetrability under Pressure) |
| Operating Temperatures | 0 °F, 30 °F, 75 °F |
| Dimensions | 38 × 15 × 13 cm |
| Weight | 5.4 kg |
| Power Requirement | None |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K95590 |
| Penetration Range | 0–62.0 mm (0–620 penetration units) |
| Resolution | 0.1 mm or 0.01 mm |
| Penetration Time | 0.1–9999.9 s (default: 5.0 s) |
| Dimensions | 31.7 × 35.6 × 45.7 cm |
| Weight | 9.5 kg |
| Power Supply | 220–240 V, 50/60 Hz |
| Compliance | ASTM D5, D217, D937, D1321, D1403, D2884, D4950 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | KLA-1-TS / KLA-2-TS / KLA-3-TS |
| Temperature Range | +80 °C to –80 °C |
| Resolution | 0.06 °C |
| Accuracy | ±0.1 °C |
| Repeatability | Compliant with or better than ASTM D2500, D97, D5771–D5773, D5853, D5950 |
| Cooling System | Dual-stage thermoelectric (Stage 1: –40 °C |
| Stage 2 | –80 °C) |
| Display | 6.4″ TFT/LCD touchscreen (640 × 480, 262K color) |
| Data Storage | >60,000 test records in Microsoft Excel-compatible format |
| Compliance | ASTM, ISO, DIN, IP standards per model configuration |
| Sample Detection Method | Coaxial fiber-optic pulse photometry (cloud point) |
| Max. Test Heads | 6 |
| Power Supply | 220 V ±15%, 50–60 Hz |
| Dimensions | 66 × 60 × 80 cm |
| Weight | 80 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K18200 Series Oxidation Stability Tester |
| Standards Compliance | ASTM D2112, D2272, D4742 |
| Operating Pressure | 90 psi (620 kPa) initial, up to 500 psi (3450 kPa) burst rating |
| Temperature Range | Ambient to 200 °C |
| Control Stability | ±0.02 °C |
| Rotation Speed | 100 rpm ± 1 rpm |
| Bath Capacity | 68 L (2-cell), 95 L (3-cell), 121 L (4-cell) |
| Heating Power | 0–2750 W (2/3-cell), 0–3750 W (4-cell) |
| Drive Motor | 0.5 hp continuous-duty, spherical bearing, integrated gear reduction |
| Bearing Type | PTFE-coated carbon fluoropolymer |
| Pressure Sensing | Direct-mount transducer on oxygen bomb |
| Safety | Auto-shutdown at >177 °C or >16.7 °C above setpoint |
| Software | Oxidata™ v5.x (Windows-based, FDA 21 CFR Part 11–ready audit trail, GLP-compliant data archiving) |