Koehler
Filter
Showing 61–90 of 95 results
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K44190 |
| Compliance | ASTM D5800 (Methods A, B, C), DIN 51581 |
| Temperature Range | 0–320 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.01 °C |
| Heating Power | 420 W |
| Dimensions (L×W×H) | 40 × 45 × 45 cm |
| Net Weight | 22 kg |
| Data Storage Capacity | >60,000 test records |
| Vacuum System | Integrated electronic vacuum pump with fluorocarbon elastomer valves and built-in particulate filter |
| Display | 6.5-inch industrial touchscreen PC |
| Interface | USB port for printer or external data transfer |
| Power Supply | 220 V ±15 %, 50/60 Hz |
| Relative Humidity Limit | ≤80 % RH |
| Repeatability & Reproducibility | Meets or exceeds ASTM D5800 requirements |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K45704-TS |
| Test Pressure | Atmospheric |
| Temperature Range | 0–450 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | −5–60 °C |
| Distillation Rate | 2–15 mL/min |
| Volume Detection Range | 0–100 mL |
| Volume Resolution | 0.01 mL |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K45859 |
| Preheat Temperature | 163 °C ±1 °C |
| Rotational Speed | 5–6 rpm |
| Internal Chamber Dimensions | 38 × 52 × 46 cm |
| External Dimensions | 57 × 87 × 63 cm |
| Weight | 44 kg |
| Power Supply | 240 V, 50 Hz |
| Compliance | ASTM D6, D1754, AASHTO T47, T179, BS 2000 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | K47001 |
| Pricing | Upon Request |
| Test Method | Open-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standard | ASTM E659 |
| Repeatability | ±5% |
| Ignition Mechanism | Fully Automated |
| Temperature Range | Ambient to 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Power Supply | 230 V, 50/60 Hz, Single-Phase, 7.7 A |
| Dimensions (W×D×H) | 37″ × 17″ × 25″ (94 cm × 43.2 cm × 63.5 cm) |
| Net Weight | 85 lb (38.6 kg) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K47190 |
| Pricing | Upon Request |
| Temperature Range | 20–100 °C |
| Dimensions | 30.5 × 61.0 × 91.4 cm |
| Weight | 18.1 kg |
| Power Supply | 220–240 V, 50/60 Hz, Single-Phase |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K47590 |
| Standards Compliance | ASTM D2384, D2747, D2784, D2785 |
| Detection Range | 0.1–300 ppm total sulfur |
| Sample Types | LPG, liquefied petroleum gases, liquid petroleum products, butane-butene mixtures |
| Combustion Method | Wickbold oxygen-hydrogen flame combustion |
| Ignition | Manual press-button ignition |
| Gas Control | Integrated pressure regulators for H₂, O₂, and N₂ |
| Construction | Stainless steel burner housed in insulated chamber with flame observation window |
| Accessories Included | Pyrex™ and quartz glassware set (200 mL sample reservoir, capillary sample delivery tube, combustion chamber, absorber, spray trap, cooling coil) |
| Optional Accessory | Gas sample adapter (for LPG, natural gas, and refinery gas) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K50119 |
| Test Plate Temperature Range | Up to 400 °C |
| Sample Oil Temperature Range | Up to 210 °C |
| Spray Speed | 0–1800 rpm (digital display) |
| Timer Range | 0–99.9 hours (adjustable countdown) |
| Acid Gas Flow Rate | 0.2–1.0 L/h |
| Oil Capacity | 0.35 L |
| Power Supply | 220–240 V, 50/60 Hz, 5 A |
| Test System Dimensions | 81 × 46 × 53 cm, 22.7 kg |
| Control Unit Dimensions | 46 × 30 × 46 cm, 11.3 kg |
| Temperature Display Units | °C or °F selectable |
| Compliance | FTM 791-3462 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K50119 |
| Compliance | FTM 791-3462 |
| Sample Volume | 0.35 L |
| Temperature Control Range | 310–320 °C (plate), independent oil bath control |
| Spray Speed | 0–1800 rpm (digital display) |
| Timer Range | 0–99.9 h |
| Gas Flow Rate | 0.2–1.0 L/h |
| Power Supply | 220 VAC, single-phase |
| Control Unit Dimensions | 46 × 30 × 46 cm, 11.3 kg |
| Test System Dimensions | 81 × 46 × 53 cm, 22.7 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K56190 (1 L/h per sample) / K56290 (15 L/h per sample) |
| Sample Capacity | 12 positions |
| Temperature Range | 80–200 °C |
| Control Stability | ±0.2 °C |
| Heating Medium | Aluminum Block |
| Standards Compliance | IP 48, IP 280, IP 306, IP 307, IP 331, IP 335 |
| Display | Dual-line LED, ℃/°F selectable |
| Overheat Protection | Automatic power cutoff above setpoint |
| Air Flow Control | Independent precision mass flow regulation per station |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K56190 |
| Sample Capacity | 12 positions |
| Temperature Range | 80–200 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Heating Bath Type | Aluminum Block |
| Air Flow Rate | 1 L/h per sample |
| Temperature Display | Dual-line LED, ℃/°F selectable |
| Power Supply | 220–240 V, 50/60 Hz, single-phase |
| Dimensions (Bath) | 43.2 × 55.9 cm |
| Dimensions (Flow Console) | 61 × 20.3 × 76.8 cm |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K60092 |
| Certifications | ASTM D91, D96, D893, D1796, D2273, D2709, D2711, D4007 |
| Max Speed | 2200 rpm |
| Max RCF | 1327 × g (long tube), 1170 × g (short tube), 865 × g (pear-shaped tube) |
| Time Range | 0–999 min |
| Speed Range | 500–2200 rpm |
| Temp. Range | Ambient to 93 °C (digital display) |
| Chamber Dimensions | 78.74 × 65.53 × 36.32 cm |
| Weight | 44.5 kg |
| Power | 220–240 V, 50/60 Hz, single-phase, 5 A |
| Explosion Protection | Class 1, Division 2 |
| Sample Capacity | 4 tubes |
| Control Interface | LCD touchscreen |
| Thermal Insulation | High-efficiency insulation for minimal heat loss |
| Balance System | Automatic rotor balancing |
| Rotor Options | Interchangeable long, short, pear-shaped, and finger-type centrifuge tubes |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | K64339 |
| Pricing | Upon Request |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Type | Laboratory Instrument |
| Test Parameter | Oxidation Stability |
| Compliance Standard | ASTM D942, IP 142, DIN 51808, FTM 791-3453 |
| Sample Capacity | 4 test specimens |
| Temperature Range | Ambient to 135 °C |
| Bath Medium | 47.3 L white mineral oil |
| Pressure Measurement Range | 0–1378 kPa |
| Oxygen Pressure | 758 kPa (initial) |
| Test Temperature | 99 °C ± 0.1 °C |
| Oxygen Bomb Working Pressure Rating | 1241 kPa at 99 °C |
| Power Supply | 220–240 V, 50/60 Hz, Single Phase, 6.8 A |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K70290 / K70390 / K70490 |
| Compliance | ASTM D2112, ASTM D2272, ASTM D4742, IP 229, SH/T 0193 |
| Temperature Control Accuracy | ±0.02°C |
| Rotation Speed | 100 rpm |
| Operating Pressure | 90 psi (620 kPa) |
| Bath Configurations | 2-, 3-, or 4-vessel units |
| Power | 0–3750 W |
| Dimensions (W×D×H) | 117 × 66 × 84 cm |
| Weight | 170 kg (4-vessel configuration) |
| Software | Oxidata™ for Windows |
| Data Channels | up to 12 pressure + 4 temperature channels |
| Safety | Over-temperature protection, corrosion-resistant polyurethane coating |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K71000 |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 405°C |
| Ignition Source | Switchable Gas or Electric Ignition |
| Applicable Standards | ASTM D93 Methods A, B & C, IP 34, ISO 2719, DIN EN 22719, JIS K2265, NF M 07-019 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K72000 |
| Detection Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automated |
| Temperature Range | Ambient to 405°C |
| Ignition Sources | Electric Spark and Gas Flame |
| Repeatability | ±1°C |
| Compliant Standards | ASTM D92, GB/T 3536, IP 36/403, ISO 2592, AFNOR T60-118, EN 22592, DIN 51376 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | K77000 |
| Price | Upon Request |
| Temperature Range | −105 °C to +50 °C |
| Compliant Standards | ASTM D5771, D5950 |
| Detection Method | Pour Point — Tilting Method |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K80000 |
| Temperature Range | 30–157°C (86–315°F) |
| Heating Power | 1500 W |
| Bath Media Compatibility | Distilled Water (30–80°C), Glycerin (80–157°C), Ethylene Glycol (30–110°C) |
| Standard Accessories | 800 mL Beaker, Two ASTM-Compliant Steel Balls, Brass Ring Molds (Shoulder-Type), Ball Centering Device, Ring Support Stand, Base Plate, Beaker Cover with Support Rod |
| Compliance | ASTM D36, ISO 4625, EN 1427, DIN 52011, IP 58, AFNOR T66-008, NF EN 1427 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K86200 |
| Density Range | 0 to 3 g/cm³ |
| Temperature Control Range | 0°C to 90°C |
| Pressure Range | 0 to 10 bar |
| Density Accuracy | ±0.00005 g/cm³ |
| Temperature Accuracy | ±0.03°C |
| Density Repeatability | ±0.00001 g/cm³ |
| Temperature Repeatability | ±0.01°C |
| Resolution | 0.00001 g/cm³ / 0.01°C |
| Minimum Sample Volume | ~1 mL |
| Display | 10.4-inch color touchscreen (800×600 px) |
| Memory | 2 GB internal storage |
| Interfaces | 3× USB, 2× RS232, Ethernet port |
| Power | 85–260 VAC, 48–62 Hz, 150–200 W |
| Dimensions | 440 × 450 × 500 mm |
| Weight | 30 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K87170 |
| Price Range | USD 14,000–70,000 (est.) |
| Distillation Mode | Vacuum (Reduced-Pressure) |
| Condenser Temperature Range | Ambient +5°C to 150°C |
| Distillation Temperature Range | Ambient to 400°C |
| Vacuum Range | 1.0–50 mmHg (0.13–6.7 kPa) |
| Electrical Supply | 120 or 220/240 VAC, 50/60 Hz |
| Dimensions | 91.5 × 94 × 53 cm |
| Weight | 91 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K88501 |
| Standards Compliance | ASTM D3427, IP 313, DIN 51381, NF E48-614 |
| Temperature Range | Ambient to 75 °C |
| Temperature Control | Microprocessor-based LED digital controller |
| Power Supply | 230 V, 50 Hz, 1.5 A |
| Dimensions (W×D×H) | 61 × 71 × 97 cm |
| Weight | 103 kg |
| Sample Volume | Standard 200 mL test vessel |
| Air Flow Control | Regulated compressed air supply with pressure gauge |
| Safety | Overheat protection circuit |
| Optional | Windows-based data acquisition software, heated sample sleeve, baffle kit, air bath circulator with calibrated thermometer and sinker |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K88539 |
| Product Type | Laboratory Instrument |
| Test Parameter | Air Release Time (ART) |
| Standards Compliance | ASTM D3427, IP 313, ISO 9120, DIN 51381, NF E 48-614, NF T 60-149, BS 2000 Part 313 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | K88629 |
| Measurement Parameters | Gasoline Octane Number, Diesel Cetane Number |
| Portability | Portable |
| Detection Principle | Near-Infrared (NIR) Transmission Spectroscopy |
| Measurement Range | Octane Number: 40–120 |
| Cetane Number | 20–100 |
| Accuracy | ±0.5 ON |
| Measurement Time | <20 s |
| Sample Volume | 225 mL |
| Repeatability | Equivalent to ASTM D2699 and D2700 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K92095 |
| Standard Compliance | ASTM D2509, ASTM D2782 |
| Rotational Speed Range | 100–800 rpm |
| Test Load Ramp Rate | 0.9–1.3 kg/s |
| Specimen Dimensions | 12.32 × 12.32 × 19.1 mm |
| Test Cup OD | 49.22 mm |
| Weight | 52 kg |
| Automatic Grease Feed Rate | 45 ± 10 g/min |
| Recirculating Fluid Reservoir Capacity | 3 L |
| Timer Range | 99 h : 59 min : 59 s |
| Loading Arm Ratio | 1:10 |
| Power Supply | 230 V, 50 Hz |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K93100 |
| Power Supply | 220 V / 60 Hz (3-phase) or 440 V / 50 Hz (3-phase) |
| Motor | 1.5 kW |
| Test Speeds | 1200, 1440, 1760 rpm (optional: 1000/3000 or 300/3000 rpm) |
| Test Duration Range | 1–9999 min |
| Ball Diameter | 12.7 mm |
| Transport Weight | 620 kg |
| Transport Volume | 1.27 m³ |
| Compliant Standards | ASTM D2266, D2596, D2783, D4172, D5183 |
| Includes | TriboDATA software, calibrated weights, ball holder assembly, ball cup, ball extractor, ball rack, ball clamp, base plate, hand tools, wrenches, electrical controller, interconnect cables, calibration & test report |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K93170 |
| Compliance | ASTM D2266, D4172, D5183, D2596, D2783 |
| Max Load | 1000 kg (servo-pneumatic closed-loop) |
| Speed Range | Up to 2000 rpm (AC servo-controlled) |
| Temperature Range | Ambient to 200 °C (integrated thermal module) |
| Friction Force Resolution | Digital load cell with real-time acquisition |
| Control Interface | 15″ multi-touch integrated panel |
| Data Interface | USB 3.0 |
| Dimensions (W×D×H) | 62.5 × 50 × 90 cm |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K94190 |
| Compliance | ASTM D5001 |
| Test Principle | Ball-on-Cylinder Lubricity Evaluation (BOCLE) |
| Sample Volume | 50 ± 1.0 mL |
| Test Temperature | 25 ± 1 °C |
| Regulated Air RH | 10 ± 0.2 % at 25 °C |
| Dry/Air Flow Rates | 0.5 L/min (through sample), 3.8 L/min (over test surface) |
| Load | 1000 g (±1 g) |
| Cylinder Speed | 240 ± 0.5 rpm |
| Test Duration | 30 ± 0.1 min |
| Test Ring | SAE 8720 steel, Ø49.10–49.25 mm × 13.0–13.11 mm, hardness 58–62 Rc, Rq 0.51–0.71 µm |
| Test Ball | AISI 52100 steel, Ø12.7 mm, hardness 64–66 Rc |
| Power Supply | 230 V AC, single-phase, 5 A |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K94454 |
| Compliance | ASTM D6138, ISO 11007, DIN 51802, BS 2000-220, IP 220, SIS 155130, NFT 60-135 |
| Test Positions | 4 |
| Rotational Speed | 80 rpm (adjustable) |
| Test Duration | 168 h (customizable) |
| Power Supply | 110–230 V, 50/60 Hz, ≤150 W |
| Dimensions (Base Unit) | 480 × 250 × 200 mm (W × D × H) |
| Expansion Module Dimensions | 260 × 230 × 170 mm |
| Control Interface | PLC-based touchscreen panel |
| Sample Media | Grease, lubricating oil, or other test media in presence of distilled water, deionized water, NaCl solution, or synthetic seawater |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K95100 |
| Standards Compliance | ASTM D36, ISO 4625, EN 1427, DIN 52011, AFNOR T66-008, IP 58, NF EN 1427 |
| Heating Range | 30–157 °C (86–315 °F) |
| Media Options | Distilled water (30–80 °C), USP glycerin (80–157 °C), ethylene glycol (30–110 °C) |
| Power | 3000 W |
| Electrical | 110–240 VAC, 50/60 Hz, 1500 W (single-phase) |
| Dimensions | 39.1 × 43.7 × 62.0 cm (15.4 × 17.2 × 24.4 in) |
| Net Weight | 32.7 kg (72 lb) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K95200 |
| Product Type | Laboratory Instrument |
| Test Parameter | Grease Adhesion Force |
| Accuracy | <0.1 N |
| Load System | Electromechanical Control |
| Sample Mass | 5 g |
| Test Duration | ~120 s |
| Result Units | N, N/mm², N/in² |
| Test Speed | 250 mm/s (standard) |
| PLC | Siemens S7-1200 + 7" HMI Touchscreen |
| Interface | Ethernet |
| Temperature Range | Ambient to 80 °C |
| Voltage | 110–230 V AC, 50–60 Hz |
| Dimensions (H×W×D) | 620 × 300 × 320 mm |
| Weight | 30 kg |
| Optional Accessory | K95200-1 Temperature-Controlled Test Chamber |