| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K19000 |
| Standard Compliance | ASTM D6184, FTM 791-321 |
| Test Temperature Range | Up to 482°C |
| Sieve Specification | 60-mesh conical wire mesh funnel with metal handle |
| Receptacle | 200 mL covered beaker |
| Net Weight | 0.2 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K19291 |
| Standards Compliance | ASTM D1264, ASTM D4950, IP 215, FTM 791-3252 |
| Test Temperatures | 38 °C and 79 °C (±0.5 °C accuracy) |
| Bearing Rotation Speed | 600 rpm |
| Motor | 1/3 HP, 1725 rpm |
| Power Supply | 220–240 V, 50 Hz, single-phase, 5.1 A |
| Dimensions (unit) | 46 × 30 × 48 cm |
| Weight (unit) | 29.5 kg |
| Water Flow Control | Capillary nozzle (1 mm), gear pump with flow meter and isolation valves |
| Independent Pump Circulation Mode | Yes |
| Temperature Control System | Cylindrical immersion heater, PID temperature controller, dual ASTM-certified thermometers (ASTM 15F: 30–180 °C |
| ASTM 15C | −2–80 °C) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K19410 |
| Price Range | USD 13,500 – 40,500 (based on FOB US port, ex-works configuration) |
| Product Type | Laboratory Instrument |
| Test Parameter | Dropping Point of Lubricating Greases |
| Compliance | ASTM D2265, ASTM D4950, ASTM D566 (extended range), ASTM D972, ASTM D2595 |
| Sample Capacity | 6 simultaneous test positions |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K19500 |
| Penetration Range | 0–62.0 mm (0–620 penetration units) |
| Resolution | 0.1 mm (1 unit = 0.1 mm) |
| Dimensions | 15 × 15 × 46 cm |
| Net Weight | 5.4 kg |
| Shipping Weight | 6.8 kg |
| Compliance | ASTM D5, D217, D937, D1321, D1403, D2884, D4950 |
| Brand | Koehler |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | K21420, K21424 |
| Price Range | USD 13,500 – 27,000 |
| Temperature Control Range | Ambient to 240 °C |
| Temperature Accuracy | ±0.03 °C |
| Bath Capacity | 19 L |
| Test Positions | 4 |
| Display | Dual-line LCD (setpoint & actual temperature) |
| Temperature Units | Selectable °C / °F |
| Timing Resolution | 0.1 s |
| Timing Accuracy | ±0.05% |
| Power Supply | 220–240 V, 50/60 Hz, Single-phase, 6.4 A |
| Dimensions (W×D×H) | 74 × 63.5 × 84 cm |
| Net Weight | 29.5 kg |
| Shipping Weight | 37 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K22685 |
| Temperature Range | –34.4 °C to Ambient |
| Temperature Resolution | ±1 °C |
| Cooling Bath Dimensions | 30.5 × 30.5 × 76 cm |
| Refrigeration Unit Dimensions | 38 × 30 × 30 cm |
| Net Weight | 51.7 kg |
| Power Supply | 220–240 V, 50 Hz, Single-Phase, 3 A |
| Compliance | U.S. Steel Method, ASTM Draft Method Dxxxx (Low-Temperature Flow of Lubricating Greases) |
| Capillary Geometry | Stainless Steel SOD Pressure Viscometer with 40:1 Ratio Tapered Capillary |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K22752 |
| Temperature Range | Standard: 5 °C to –30 °C |
| Extended | 5 °C to –70 °C |
| Temperature Stability | ±0.1 °C (calibrated to 0.01 °C) |
| Bath Volume | 14 L |
| Capacity | 4 capillary viscometers |
| Control System | Microprocessor-based PID control with dual-line digital display |
| Cooling System | Two-stage compressor refrigeration |
| Compliance | ASTM D445 |
| Power Supply | 220–240 V, 50 Hz, single-phase, 14.5 A |
| Dimensions & Weight | 42 × 35 × 36 cm, 80 kg |
| Optical Flow Detection | Integrated (LKV5000 variant only) |
| Uniformity | Meets and exceeds ASTM D445 spatial temperature uniformity requirements |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K23060 |
| Standards Compliance | ASTM D3230, IP 265 |
| Measurement Range | 0–150 PTB (pounds per thousand barrels) |
| Temperature Range | −5 °C to 55 °C |
| Display | 2.6-inch TFT-LCD |
| Power Supply | Internal rechargeable Li-ion battery |
| AC adapter input | 230 V, 50/60 Hz, single-phase |
| Dimensions (W×D×H) | 9 × 4.25 × 2.5 in (23 × 10.8 × 6.5 cm) |
| Net Weight | 2 lb (1 kg) |
| Sample Volume | 100 mL |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | K23900 |
| Pricing | Upon Request |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K24110, K24120, K24130 |
| Temperature Range | Ambient to 1125°C |
| Setpoint Repeatability | ±1°C |
| Setpoint Accuracy | ±4°C |
| Temperature Uniformity (K24110/K24120/K24130) | ±5°C / ±8°C / ±10°C |
| Chamber Volume | 4 L / 16 L / 36 L |
| Air Exchange Rate | 2–4 complete exchanges per minute |
| Compliance | ASTM D482, D874, D1026, D3174, D4422 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K26210-3 |
| Standard Compliance | ASTM D6082 |
| Test Temperature | 150 °C |
| Temperature Uniformity | ±0.5 °C |
| Bath Volume | 38.5 L |
| Air Flow Rate | 200 mL/min |
| Power Supply | 220–240 V, 50 Hz |
| Dimensions (W×D×H) | 82 × 38 × 79.4 cm |
| Weight | 28.1 kg |
| Heating System | Immersed copper heater with PID-controlled microprocessor |
| Temperature Display | Dual LED, selectable ℃/°F |
| Construction | Steel base with chemical-resistant polyimide enamel coating |
| Includes | Two 1000 mL calibrated test cylinders, two calibrated antifoam heads, two air inlet tubes, two exhaust tubes, two rubber stoppers, one bath tank, one support stand |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | K26400 |
| Price | Upon Request |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K27000 |
| Standards Compliance | ASTM D1322, ISO 3014 |
| Dimensions | 18 cm Ø × 47 cm H |
| Net Weight | 4.5 kg |
| Construction | Brass lamp body, copper-plated viewing window, adjustable aluminum base, calibrated 0–50 mm black glass scale, cotton wick assembly with air vent, candle socket |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K27190 |
| Temperature Range | Ambient to 650 °C |
| Temperature Stability | ±1 °C (±2 °F) |
| Sample Capacity | 5 samples per run |
| Furnace Material | Cast iron |
| Heating Power | 0–2400 W, ceramic band heater |
| Dimensions | 41 × 55 × 37 cm |
| Weight | 29 kg |
| Power Supply | 220–240 V, 50/60 Hz, single-phase, 10.9 A |
| Compliance | ASTM D524, ASTM D6074, IP 14, ISO 4262, FTM 791-5002, NF T 60-117 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K29300 |
| Product Type | Laboratory Instrument |
| Test Parameter | Evaporation Loss |
| Test Capacity | 2 samples |
| Temperature Range | 93–316 °C (digital display) |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Stability | ±0.1 °C at setpoint |
| Heating System | Dual 0–500 W variable power controllers with K-type thermocouples |
| Air Flow Control | 2.0 L/min at STP (Standard Temperature and Pressure), independently regulated via dedicated preheater and rotameter |
| Display | Dual LED — setpoint & actual temperature |
| Heating Chamber | Aluminum-block furnace with integrated sample-zone and air-stream thermal management |
| Safety Systems | Overtemperature cutoff, overpressure protection circuit, PID-based microprocessor temperature controller with fail-safe logic |
| Power Requirement | 220–240 V AC, 50/60 Hz, single-phase, 10.4 A |
| Dimensions | 64 × 41 × 43 cm |
| Weight | 79.4 kg |
| Compliance | ASTM D2595, ASTM D2878 |
| Optional Accessory | K29310 Digital Thermometer (sold separately) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K29795 |
| Price Range | USD 14,000 – 70,000 |
| Temperature Range | Ambient to –73°C (–100°F) |
| Resolution | 0.1°C / 0.1°F |
| Accuracy & Uniformity | Exceeds ASTM D2386 requirements across full operational range |
| Power Supply | 220–240 V, 50 Hz, Single Phase, 10 A |
| Dimensions | 89 × 66 × 78.75 cm |
| Weight | 117.75 kg |
| Cooling Method | Air-cooled, CFC-free refrigeration |
| Display | Dual digital PID controller with selectable °C/°F scale |
| Safety Features | Enhanced enclosure design, transparent observation window with integrated LED illumination, adjustable leveling feet |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K30165 |
| Standards Compliance | ASTM D665, ASTM D3603, ASTM D6158, IP 135 |
| Test Capacity | 6 samples |
| Stirring Speed | 1000 rpm (max 2200 rpm) |
| Temperature Range | Ambient to 104°C |
| Temperature Stability | ±0.5°C |
| Control Accuracy | ±0.5°C |
| Drive Motor | Explosion-protected ball-bearing induction motor, 1/12 hp |
| Dimensions | 83 × 36 × 69 cm |
| Weight | 35.9 kg |
| Power Supply | 220–240 V, 50/60 Hz, single-phase, 6.8 A |
| Construction | Stainless steel housing with chemical-resistant polyurethane coating |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K30165NACE |
| Sample Capacity | 6 positions |
| Bath Volume | 41.6 L |
| Temperature Range | Ambient to 104°C (220°F) |
| Temperature Stability | ±0.5°C (±1°F) |
| Stirring Speed | 1000 rpm |
| Heating Medium | White mineral oil |
| Power Supply | 220–240 V, 50 Hz, 6.8 A, Single-phase |
| Dimensions (W×D×H) | 83 × 36 × 69 cm |
| Weight | 35.8 kg |
| Construction | Stainless steel housing with chemical-resistant polyurethane coating |
| Motor Type | Explosion-proof ball-bearing induction motor, 1/12 hp |
| Control System | Microprocessor-based with °C/°F toggle and digital setpoint display |
| Overtemperature Protection | Integrated safety circuit |
| Compliance | ASTM D665, D6158, D3603, IP 135, ISO 7120, DIN 51585, FTM 791-4011, NFT 60-151 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K30269 |
| Pricing | Upon Request |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K33900 |
| Compliance | ASTM D381, IP 131, ISO 6246, DIN 51784, FTM 791-3302, NF M07004 |
| Configuration | 6-position aluminum block bath with integrated steam superheater |
| Temperature Range | Up to 246 °C (475 °F) |
| Temperature Stability | ±0.5 °C |
| Heating Power | 0–3000 W |
| Steam Superheater | Stainless steel chamber, solid-state temperature control (0–290 °C), dry saturated steam delivery |
| Air/Steam Flow Control | Digital mass flow meter + pressure regulator with gauge |
| Safety | Over-temperature cut-off circuit, insulated aluminum block, dual LED display (°C/°F), PID microprocessor temperature control |
| Electrical | 220–240 V, 50/60 Hz, single-phase, 30 A |
| Dimensions (W×D×H) | 53.34 × 52.07 × 71.12 cm |
| Net Weight | 104.3 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K34715 |
| Pricing | Upon Request |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K38590 |
| Sample Capacity | 10 positions |
| Temperature Range | +80 °C to –40 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Refrigeration Rate | up to 5.0 °C/min |
| Refrigerant | R-507 |
| Compressor Power | 1/3 hp |
| Heating Power | 600 W |
| Power Supply | 220 V, 50/60 Hz, 7 A |
| Dimensions | 39 × 32 × 34 cm |
| Weight | 47.6 kg |
| Construction | Stainless steel housing and durable thermoplastic components |
| Compliance | ASTM D4684, D3829, D6896, D6821*, SAE J300, ILSAC GF-3/GF-4 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Product Origin | Imported |
| Model | K38590 |
| Pricing | Upon Request |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K39199 |
| Standards Compliance | ASTM D2711, DIN 51353 |
| Temperature Control | Microprocessor-based digital bath control with dual LED display (setpoint & actual) |
| Bath Volume | 38.5 L |
| Dimensions (W×D×H) | 39 × 38 × 94 cm |
| Net Weight | 32.6 kg |
| Shipping Weight | 60.3 kg |
| Shipping Volume | 25.4 cu. ft. |
| Stirring Assembly | Dual independent motor-driven stainless-steel impellers with precision speed adjustment (LED speed display), ASTM D2711-compliant geometry including top/center/bottom bearings, stainless-steel shaft and mounting plate |
| Sample Configuration | Two parallel test positions with two K39103 stirrers and two K39120 separation funnels |
| Construction | All wetted parts stainless steel |
| Illumination | Integrated bath interior lighting for visual monitoring |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K39495 |
| Temperature Range | 25–84 °C |
| Temp. Stability | ±0.05 °C |
| Stirring Speed | 0–2000 rpm |
| Stirring Accuracy | ±1 rpm |
| Simultaneous Test Capacity | 7 × 100 mL samples |
| Bath Medium | Water or white mineral oil |
| Bath Volume | 15.15 L |
| Power Supply | 220–240 V / 50 Hz / 12 A |
| Dimensions (W×D×H) | 52.7 × 38.75 × 74.9 cm |
| Heating Power | 75 W (1/10 hp) |
| Bath Material | Transparent polycarbonate (25.5 × 28 × 24 cm) |
| Standards Compliance | ASTM D1401, D6074, D6158 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | K39496 |
| Pricing | Upon Request |
| Product Type | Laboratory Instrument |
| Test Parameter | Water Separability (Emulsion Breaking Time) |
| Standards Compliance | ASTM D1401, D6074, D6158 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K41090 |
| Standards Compliance | ASTM D4530, D482, D189 |
| Max Temperature | 800 °C |
| Data Storage | 200 test records |
| Power Supply | 230 V, 50–60 Hz |
| Dimensions | 63 × 43 × 48 cm |
| Weight | 35 kg |
| Interface | RS232 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K41594 |
| Application Method | Fluorescent Indicator Adsorption (ASTM D1319) |
| Max Sample Boiling Point | ≤315°C |
| Column Configurations | 2-, 4-, or 6-position |
| Operating Pressure Range | 0–15 psi |
| Power Supply | 230 V, 50/60 Hz |
| Dimensions (W×D×H) | 20 × 66 × 208 cm |
| Weight | 45.5 kg |
| Analysis Tube ID × Length | 3 mm × 1200 mm |
| Column Sealing | O-ring compression fitting |
| Silica Gel Loading | Integrated porous polyethylene disc + electronic shaker (on/off + amplitude control) |
| Pressure Control | Independent regulator per column |
| Material | Stainless steel clamping seals |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K43092 |
| Test Temperature | 24 °C and 93.5 °C |
| Temperature Uniformity | ±0.5 °C |
| Air Flow Rate | 94 mL/min |
| Flow Control | Four independently calibrated mass flow meters |
| Stirrer | 1/20 hp recirculating stirrer |
| Bath Configuration | Dual-temperature (24 °C + 93.5 °C), four-test-unit system |
| Cooling | Integrated cooling coil |
| Safety | Over-temperature cut-off protection |
| Compliance | ASTM D892, ASTM D6082, GB/T 12579, IP 146, DIN 51566, FTM 791-3211, NF T 60-129 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | NOACK |
| Standard Compliance | ASTM D5800, DIN 51581 |
| Temperature Range | 150–350 °C (±0.1 °C accuracy) |
| Heating Medium Options | Aluminum block (non-Wood’s alloy) or Wood’s alloy bath |
| Power Supply | 230 V, 50 Hz, 5.8 A |
| Dimensions (K44090) | 59 × 35 × 68 cm |
| Weight (K44090) | 26.7 kg |
| Dimensions (K44091) | 54 × 38 × 37 cm |
| Weight (K44091 with accessories) | 38.2 kg |
| Sample Mass | 65 g |
| Test Duration | 60 min at specified temperature |
| Air Flow Control | Manual (incl. inclined-tube manometer, 0–30 mm H₂O) or optional automated pressure regulation |