MAE
Filter
Showing all 4 results
| Brand | MAE |
|---|---|
| Country of Origin | Italy |
| Model | GPR LMX200 |
| Power Supply | 12 V DC, 1.25 A |
| Battery | Sealed Lead-Acid Gel, 9 Ah |
| Dimensions (L×W×H) | 100 cm × 70 cm × 115 cm |
| Weight | 22 kg |
| Ingress Protection | IP66 |
| Operating Temperature (Sensor) | –40 °C to +50 °C |
| Operating Temperature (DVL Unit) | –10 °C to +50 °C |
| Spatial Sampling Interval | 5 cm |
| Maximum Investigation Depth | 8 m (real-time display range: 1–8 m) |
| Signal Enhancement | Dyna Q technology |
| Data Acquisition Mode | Real-time depth estimation and visualization |
| Brand | MAE |
|---|---|
| Origin | Italy |
| Model | A6000E |
| Output Current | Up to 1.2 A @ 50 V (4-step auto-adjustable) |
| Output Voltage | ±50 V, ±100 V, ±250 V, ±500 V |
| Max Power | 60 W (extendable to 600 W with external generator) |
| Input Integration Time | 100 ms – 30 s (auto-ranging across 4 scales) |
| Full-Scale Input Voltage | 50 V |
| Input Impedance | 1 MΩ |
| Notch Filter | 50 Hz |
| Voltage Measurement Accuracy | ±38 µV (0–1.25 V range), ±1.53 mV (5–50 V range) |
| Resistance Measurement Accuracy | ±1% |
| Electrode Capacity | 32 standard electrodes |
| Electrode Cable | High-resistivity geophysical cable with 16 connectors per segment |
| inter-electrode spacing options | 2 m, 3 m, 5 m, or 10 m |
| Data Storage | Internal solid-state disk + USB flash drive support |
| Interface Ports | LAN, USB, VGA |
| Display | 10.4" resistive touchscreen |
| Embedded OS | Windows Embedded Standard 2009 |
| Operating Temperature | −20 °C to +80 °C |
| Dimensions | 470 × 229 × 351 mm |
| Weight | 9 kg |
| Power Supply | 12 V DC from integrated 24 Ah rechargeable battery pack (avg. current draw: 2 A) |
| Data Formats | TSV, CSV, DAT |
| Brand | MAE |
|---|---|
| Country of Origin | Italy |
| Model | A6000S |
| Instrument Type | Portable Seismograph |
| ADC Resolution | 24-bit |
| Dynamic Range | 144 dB (theoretical) |
| Total Harmonic Distortion | ±0.001% |
| Bandwidth | 2 Hz to 30 kHz |
| Common-Mode Rejection Ratio | 110 dB @ 60 Hz |
| Input Noise Floor | 27 nV |
| Trigger Accuracy | ±1/30 sampling interval |
| Input Voltage Range | ±5 V |
| Input Impedance | 20 MΩ @ 1 kS/s |
| Programmable Gain | 0, 6, 12, 18, 24, 30, 36 dB (per-channel configurable) |
| Anti-Aliasing Filter | −3 dB at 80% Nyquist frequency, −80 dB stopband attenuation |
| Sampling Intervals | 0.033 ms to 20 ms (discrete steps) |
| Sample Count per Acquisition | 1,024–21,800 (512-sample increments) |
| Pre-trigger Time | 1–500 ms (26 selectable values) |
| Channel Configuration | 12 or 24 channels (user-selectable per acquisition) |
| Acquisition Modes | Triggered (all channels), Continuous (up to 12 channels) |
| Calibration | Automatic ADC calibration prior to each acquisition |
| Digital Filtering | Auto-configured based on sampling rate |
| Data Storage | Host PC internal storage |
| Trigger Polarity | Positive or negative (software-selectable) |
| Data Format | SEG-2 (32-bit binary) or ASCII |
| Sensor Diagnostics | Real-time open-circuit, short-circuit, and sensor failure detection via cable signal analysis |
| Interfaces | USB 2.0, 10/100/1000BASE-T Ethernet, VGA video output |
| Brand | MAE |
|---|---|
| Origin | Italy |
| Model | C313SEV |
| Output Voltage Range | ±50 V, ±100 V, ±250 V, ±500 V, ±800 V |
| Max Output Current | 5 A |
| Max Output Power | 250 W |
| Current Resolution | ±0.2 µA |
| Potential Measurement Range | ±25 V |
| Input Impedance | 2.5 MΩ |
| Potential Resolution | ±1.5 µV (within ±25 V) |
| Sampling Interval | 0.25 s |
| Noise Reduction | 2–10 sample averaging |
| Built-in Battery | 12 V / 12 Ah |
| Operating Temperature | −20 °C to +80 °C |
| Enclosure Rating | IP42 |
| Display | 7" TFT LCD touchscreen |
| Data Storage | Internal SD card (~3 GB), USB port (included) |
| Data Formats | TSV, CSV, DAT |
| Communication Ports | LAN, USB, VGA |
| Dimensions | 49 × 19 × 26.4 cm |
| Weight | 9.6 kg |
| Operating System | Embedded Windows |
| Language Support | English, Italian |