METTLER TOLEDO
Filter
Showing 271–300 of 403 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QuickFlow |
| Quotation | Upon Request |
| Ultimate Vacuum | Not Applicable |
| Maximum Pumping Speed | Not Applicable |
| Dimensions | Not Specified |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | R-Series Signature |
| Compliance | HACCP, FDA 21 CFR Part 11 (with optional audit trail), ISO 22000, BRCGS Food Safety Issue 9, IFS Food v7, USP <1043> (for pharmaceutical applications) |
| Detection Capability | Ferrous, non-ferrous, and stainless steel contaminants (including 304/316 austenitic grades) in packaged, bulk, powder, and viscous product streams |
| Integration | Compatible with conveyor belts, gravity-fed chutes, pipe-based flow systems, and automated reject mechanisms |
| Regulatory Support | Factory-calibrated per ASTM F1359–22 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model Series | R/T/L/Series |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | E4 XLS+ |
| Channel Configurations | 1-, 6-, 8-, and 12-channel |
| Volume Range | 0.5–10 µL, 1–10 µL, 2–20 µL, 5–50 µL, 10–100 µL, 20–200 µL, 20–300 µL, 100–1000 µL, 100–1200 µL, 200–2000 µL, 500–5000 µL, 1–10 mL, 2–20 mL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Pipet-Lite XLS+ |
| Volume Range | 0.1–20 mL (multiple fixed-volume variants) |
| Sterilization | Autoclavable (121°C, 20 min) |
| Tip Compatibility | LTS (Low-Torque Seal) and universal conical tips |
| Ergonomic Design | Integrated finger hooks, thumb cushion, internal dampening mechanism |
| Compliance | ISO 8655 compliant |
| RFID | Embedded for asset tracking |
| Channel Options | 1-, 6-, 8-, and 12-channel |
| Adjustable Spacing | 9–14 mm (8-channel), 9–19 mm (6-channel) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | Pipet-One / LTS / XLS |
| Type | Manual Single-Channel Pipettes |
| Compliance | ISO 8655, GLP/GMP-ready |
| Tip Compatibility | LTS (Low-Torque Seal) and Universal Conical |
| Calibration Support | MCP Calibration Workstation (ISO 8655-compliant) |
| Ergonomics | Optimized grip geometry, reduced tip ejection force (<15 N), adjustable volume lock |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RC1mx |
| Instrument Type | Reaction Calorimeter |
| Temperature Range | −70 °C to 300 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Accuracy | ±0.5 K |
| Automation Level | Fully Automated |
| Compliance Context | Designed for GLP/GMP-aligned process safety development and regulatory submission support (e.g., ICH Q5, Q9, Q11 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | ReactIR 701L |
| Instrument Type | In-line / Flow-through Process Spectrometer |
| FTIR Architecture | Michelson Interferometer-Based |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Spectral Resolution | 4 cm⁻¹ |
| Scan Rate | 7 scans per second |
| Signal-to-Noise Ratio (SNR) | 2000:1 |
| Detector | High-Sensitivity, Liquid-Nitrogen-Cooled MCT (Mercury Cadmium Telluride) |
| Probe Compatibility | Fiber-Optic ATR, Transmission, and Reflectance Probes |
| Operating Environment | Lab-scale reactors (glass, stainless steel), flow cells, and microreactors |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | ReactIR 702L |
| Instrument Type | In-line / Flow-through Process Analytical Technology (PAT) System |
| Spectral Range | 4000–800 cm⁻¹ |
| Detector | Solid-State Cooled MCT (Mercury Cadmium Telluride) |
| Optical Interface | Fiber-Optic Probe Coupling (No Purge Gas Required) |
| Configuration | Benchtop, Stackable, Vent-Hood Compatible |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | ReactIR™ 45m, ReactIR™ 45p |
| Instrument Type | In-situ, Real-time Online FTIR Spectrometer |
| Wavenumber Range | 4000–650 cm⁻¹ |
| Resolution | 4 cm⁻¹ |
| Signal-to-Noise Ratio | 2000:1 |
| Scan Speed | Not specified (typical for high-stability process-grade FTIR) |
| Probe Materials | Diamond, Silicon, Zirconia ATR crystals |
| Wetted Materials | Hastelloy®, Gold |
| Temperature Range | −80 °C to 200 °C (optional up to 300 °C) |
| Pressure Rating | Vacuum to 7 bar (optional up to 350 bar) |
| Probe Diameters | 6.35 mm, 9.5 mm, 16 mm, 25.4 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DS Micro Flow Cell |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ReactRaman 802L |
| Instrument Type | Fourier Transform Raman Spectrometer |
| Spectral Range | 150–3400 cm⁻¹ |
| Spectral Resolution | 6 cm⁻¹ |
| Spatial Resolution | 2 µm |
| Minimum Wavenumber | 50 cm⁻¹ |
| Spectral Repeatability | ±0.2 cm⁻¹ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 30PX / 30GX |
| Measurement Principle | Sodium D-line (589.3 nm) critical angle method |
| Refractive Index Range | 1.32–1.50 (30PX), 1.32–1.65 (30GX) |
| Resolution | 0.0001 RIU |
| Accuracy | ±0.0005 RIU |
| Temperature Range | 10–40 °C |
| Temperature Compensation | Integrated Peltier-controlled sensor with automatic compensation (ATC) |
| Display | High-resolution LCD |
| Data Output | USB and optional Bluetooth connectivity |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Rondo 12 / 15 / 20 / 30 / 60 / 60 Plus |
| Sample Capacity | 12–60 positions |
| Compatible Vessels | 80–600 mL (PE, borosilicate glass) |
| Integration Options | KF coulometric water determination, COD digestion modules, CoverUp sealing system, SU24 sample handler, Rondolino entry-level station, Liquid Handler for automated reagent/sample dispensing |
| Regulatory Compliance | Designed for GLP/GMP environments with audit trail and electronic signature support per FDA 21 CFR Part 11 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RTCal™ |
| Temperature Ramp Rate | 8 °C/min |
| Emergency Cooling Rate | 30 °C/min |
| Temperature Control Modes | Tr (isothermal/gradient), Tj (isothermal/gradient), reflux/condensation, crystallization, adiabatic |
| Agitation Speed Range | 30–2500 rpm (repeatability ±1%) |
| Maximum Torque | 1 N·m |
| Overall Heat Transfer Coefficient (U-value) | online measurement, accuracy ±1%, repeatability 1–3% (standard experiments) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RX-10 |
| Application Scope | Jacketed laboratory reactors (mL to L scale) |
| Integrated PAT Compatibility | In-situ pH, FTIR, FBRM, PVM, particle size analysis |
| Control Interface | Touchscreen + iC/iControl software suite |
| Regulatory Support | 21 CFR Part 11 compliant audit trail, electronic signature, data integrity features |
| Thermal Control Integration | Compatible with external chillers, heaters, and circulators |
| Data Acquisition | Synchronized timestamped logging of temperature, stirring speed, dosing volume, pH, and PAT sensor streams |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SC1 / SC30 |
| Sample Capacity | 1 vial (20 mL, 9 mL, or 6 mL) |
| Maximum Sample Viscosity | ≤ 30,000 mPa·s |
| Sample Introduction Method | Positive-pressure pumping |
| Cleaning Protocol | Dual-solvent automated rinse and dry |
| Drying Method | Pneumatic-assisted air-drying |
| Temperature Control | Optional electric heating module (for sample pre-conditioning) |
| Sample Recovery | Optional automatic return to source vial |
| Compliance | Designed for integration with METTLER TOLEDO DE (density), RE (refractometry), and DR (combined density/refractometry) instruments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SCS/ZCS/PDX |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model Series | SCS, ZCS, ZCU, SCU |
| Pricing | Available Upon Request |
| Explosion Protection | ATEX / IECEx Certified Configurations Available |
| Load Capacity Range | 30–150 t (typical) |
| Accuracy Class | OIML R76-1 Class C3 or C4 |
| IP Rating | IP68 (load cells), IP65 (junction boxes & indicators) |
| Operating Temperature | –30 °C to +70 °C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Status | Authorized Service Provider |
| Product Origin | Imported |
| Model | METTLER TOLEDO Service Portfolio |
| Service Fee Range | USD 7,000–14,000 (varies by scope) |
| Field Experience | >100 years in precision measurement support |
| Instrument Type | Analytical & Weighing Instruments |
| Response Time | Within 24 hours (standard SLA) |
| Service Scope | End-to-end lifecycle support for laboratory instrumentation |
| Geographic Coverage | Pan-China service network with localized technical teams |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Seven2Go (S2, S3, S4, SG23, S7, S8, S9) and SevenGo Duo (SG68, SG78, SG98) |
| Measurement Parameters | pH / mV / Ion Concentration / Conductivity / TDS / Resistivity / Salinity / Dissolved Oxygen / Atmospheric Pressure / Temperature |
| Temperature Compensation Modes | Linear, Non-linear, Pure Water |
| Calibration Points | up to 5 (pH), up to 25 (Conductivity), up to 5 (Dissolved Oxygen) |
| Buffer/Standard Sets | 4 (pH), 3 (Conductivity), 4 (Dissolved Oxygen), 138–666 µS/cm custom ranges |
| Electrode Constant Input | Manual or Automatic (via ISM) |
| Endpoint Detection | Auto or Manual |
| Interval Measurement | Configurable |
| Display | Backlit LCD |
| Connectivity | Infrared (IR), micro-USB |
| Data Storage | 200–2000 GLP-compliant records (model-dependent) |
| Protection Rating | IP67 |
| Power Supply | 4× AA alkaline or NiMH batteries |
| Language Support | Up to 12 languages |
| Compliance | GLP, ISO/IEC 17025-aligned data integrity, FDA 21 CFR Part 11-ready (with optional software and audit trail configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S3, S7 |
| Portability | Portable |
| Conductivity Range | 0.000 µS/cm to 1000 mS/cm |
| TDS Range | 0.01 mg/L to 600 g/L |
| Resistivity Range | 0.00 to 100.0 MΩ·cm |
| Salinity Range | 0.00 to 42 PSU |
| Temperature Range | –5.0 to 105.0 °C |
| Accuracy | ±0.5% of reading |
| Minimum Resolution | 0.001 |
| Compliance | IP67 rated |
| Electrode Interface | ISM® (Intelligent Sensor Management) compatible |
| Display | High-contrast sunlight-readable LCD with StatusLight indicator |
| Data Transfer | IP67-rated USB port |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S2, S8 |
| Instrument Type | Portable |
| Parameter Type | Single-parameter (pH/mV/Ion) |
| Measurement Range | −2.000 to 20.000 pH |
| Resolution | 0.001 / 0.01 / 0.1 pH |
| Accuracy | ±0.002 pH |
| Calibration Solution Compatibility | NIST-traceable USA-type buffers (international version) |
| Ingress Protection Rating | IP67 |
| ISM Support | Yes (InLab ISM™ smart electrode recognition) |
| Display | High-contrast sunlight-readable LCD with StatusLight indicator |
| Interface | IP67-rated USB port |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Operating Environment | Lab, field, and process-line applications |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S4, S9 |
| Portability | Portable |
| Measurement Principle | Polarographic (Clark-type) or Optical (Luminescence-based) — configurable per probe |
| Measurement Range | 0.00–50.0 mg/L (ppm) |
| Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–50 mg/L) |
| Repeatability | ±0.05% of reading |
| Detection Limit | ±2 ppb (O₂ in water) |
| Ingress Protection | IP67 |
| Electrode Compatibility | ISM® (Intelligent Sensor Management) enabled |
| Data Interface | Waterproof USB (IP67-rated) |
| Display | High-contrast, sunlight-readable LCD with StatusLight™ indicator |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Parameter Capability | Multi-parameter |
| pH Accuracy | ±0.002 |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.001 |
| mV Range | –2000 to +2000 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1 mV |
| Calibration Standards | NIST-traceable US standard buffer solutions |
| Ingress Protection | IP54 |
| Display | High-contrast color TFT touchscreen |
| Language Support | 12 built-in interface languages |
| Connectivity | USB-A (host & device), RS232, optional Bluetooth® module |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Measurement Modes | pH, mV, rel. mV, ORP, ion concentration (with appropriate electrode) |
| pH Range | –2.000 to 20.000 |
| Resolution | 0.001 / 0.01 / 0.1 (user-selectable) |
| Accuracy | ±0.002 pH |
| Calibration Options | 1–5 point calibration with automatic buffer recognition |
| Display | 4.3" full-color TFT touchscreen |
| Environmental Rating | IP54 |
| Language Support | 12 languages |
| Connectivity | USB-A (host), USB-B (device), RS232 (optional), Bluetooth (S230 only) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Model | SevenCompact™ S230 |
| Measurement Range | 0.001 µS/cm to 1000 mS/cm |
| Conductivity Accuracy | ±0.5% |
| TDS Range | 0.00 mg/L to 1000 g/L |
| Salinity Range | 0.00–80.0 psu |
| Resistivity Range | 0.00–100.0 MΩ·cm |
| Ash Conductivity (Conductivity Ash) | 0.000–2022% |
| Temperature Compensation | Automatic (ATC) or Manual (MTC), -5.0 to 130.0 °C (ATC), -30.0 to 130.0 °C (MTC) |
| Resolution | Auto-variable from 0.001 µS/cm to 1 mS/cm |
| Data Storage | 1000 GLP-compliant entries |
| IP Rating | IP54 |
| Connectivity | RS232, USB-A (for printer, flash drive, keyboard, barcode scanner, stirrer), USB-B (for PC) |
| Compliance | Supports FDA 21 CFR Part 11 audit trail via LabX Direct software (optional) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Application | Laboratory |
| Conductivity Range | 0.000 µS/cm to 2,000 mS/cm |
| TDS Range | 0.00 mg/L to 1,000 g/L |
| Resistivity Range | 0.00 to 100.0 MΩ·cm |
| Salinity Range | 0.00 to 80.00 PSU |
| Temperature Range | –30.0 to 130.0 °C |
| pH Range | –2.000 to 20.000 |
| mV Range | –2,000.0 to 2,000.0 mV |
| Ion Concentration (pX) | –2.000 to 20.000 |
| Resolution (pH/pX) | 0.001 |
| Accuracy (pH) | ±0.002 |
| Temperature Accuracy | ±0.1 °C (0–100 °C) |
| Calibration | Up to 5-point pH/ion, 1–2-point conductivity, manual or auto electrode constant determination |
| Data Storage | GLP-compliant with timestamp, sample ID, electrode ID, user ID |
| IP Rating | IP54 |
| Display | 7-inch color touchscreen |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Model | SD20 |
| Measurement Parameters | pH, mV (ORP), ref mV, Temperature |
| pH Range | –2.000 to 20.000 |
| mV Range | –2000.0 to 2000.0 |
| Temperature Range | –30.0 to 130.0 °C |
| Resolution | 0.001/0.01/0.1 pH (adjustable), 0.1/1 mV, 0.1 °C |
| Accuracy | ±0.002 pH |
| Temperature Compensation | Automatic & Manual |
| Calibration Points | Up to 5-point |
| Buffer Sets | 11 preloaded + 10 customizable |
| Endpoint Modes | Auto, Manual, Time Interval |
| Language Support | 10 languages (English, Chinese, German, French, Italian, Russian, Korean, Spanish, Portuguese, Dutch) |
| Data Storage | 2000 GLP-compliant entries with timestamp, sample ID, electrode ID, user ID |
| Connectivity | USB for PC export and printer output |
| IP Rating | IP54 |
| Display | 7-inch full-color capacitive touchscreen |
| User Management | Two-level access control (Operator/Admin) |
| Compliance | Fully GLP-compliant with audit trail-ready data logging |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Measurement Parameters | Conductivity, TDS, Resistivity, Salinity, Temperature |
| Conductivity Range | 0.000 µS/cm to 2,000 mS/cm |
| TDS Range | 0.00 mg/L to 1,000 g/L |
| Salinity Range | 0.00–80.00 psu |
| Resistivity Range | 0.00–100.0 MΩ·cm |
| Temperature Range | −30.0 to 130.0 °C |
| Resolution | Auto-ranging, up to 0.001 (conductivity), 0.1 °C (temperature) |
| Accuracy | ±0.5% of reading (conductivity), ±0.1 °C (0–100 °C) |
| Temperature Compensation | Automatic/manual |
| Calibration | Up to 2-point, auto-identification of standard solutions, built-in 13 calibration standards + 10 user-defined |
| Endpoint Modes | Auto, manual, time-based |
| Data Storage | 2,000 GLP-compliant records with timestamp, sample ID, electrode ID, operator ID |
| Connectivity | USB for data export (U-disk or PC software), optional printer interface |
| Compliance | Fully GLP-compliant |
| Enclosure Rating | IP54 (dust-protected, splash-resistant) |
| Display | 7-inch full-color capacitive touchscreen with glove-mode support |
| User Interface | 10 languages (English, Chinese, German, French, Italian, Russian, Korean, Spanish, Portuguese, Japanese) |
| Security | Dual-level user management (administrator/operator) |
| Accessories Included | InLab® 731-ISM conductivity electrode, EasyMix™ magnetic stirrer, precision electrode stand with vertical adjustment and multi-directional positioning, replaceable protective cover, corrosion-resistant sealed interface housing, pouch-packaged calibration standards |