METTLER TOLEDO
Filter
Showing 181–210 of 567 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro 4260 |
| Type | Industrial online pH electrode with open junction and polymer reference system |
| Reference System | XEROLYT® EXTRA polymer gel |
| Junction Type | Open junction (non-ceramic, non-porous) |
| Temperature Compensation | Integrated Pt100 or Pt1000 RTD available |
| Sterilization Compatibility | Autoclavable up to 135 °C, CIP/SIP compatible |
| Application Environment | High-protein, high-solids, sulfide-rich, viscous, and aggressive industrial process streams |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Online DO Analyzer |
| Measurement Principle | Optical Luminescence Quenching (ISO 5814:2012 compliant) |
| Range | 0.00–80.00 mg/L (0– saturation, 0–50 ppm, 0–50,000 ppb) |
| Accuracy | ±0.2 mg/L at 25°C |
| Repeatability | ≤0.05% of reading |
| Detection Limit | <2 ppb (in high-purity water mode) |
| Sensor Technology | ISM® (Intelligent Sensor Management) enabled |
| Compliance | FDA 21 CFR Part 11 ready, USP <1231>, ASTM D888, ISO 5814, EN 25814 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | In-situ Tunable Diode Laser (TDL) Oxygen Analyzer |
| Measurement Principle | Absorption Spectroscopy at 760 nm |
| Detection Range | 0–25% O₂ (vol%) |
| Response Time (T90) | < 1 s |
| Accuracy | ±0.1% O₂ (full scale) |
| Operating Temperature | –20 to +65 °C (probe) |
| IP Rating | IP66/IP67 (probe), IP65 (transmitter) |
| Compliance | ATEX II 2G Ex db IIB T4 Gb, IECEx db IIB T4 Gb, SIL2 per IEC 61508 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro 8600 |
| Measurement Range | 0–100 EBC / 0–400 FTU |
| Process Connection | Inline sanitary sleeve (Varivent®-compatible) |
| Wetted Materials | 316L stainless steel, sapphire optics |
| Operating Temperature | 0–80 °C (standard), up to 120 °C (short-term) |
| Operating Pressure | 1–16 bar |
| Optical Detection Angles | 25° and 90° scattering |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Range | InPro 2000, InPro 2002, InPro 3x00, InPro 4x00, InPro 5x00, InPro 7x00 |
| Electrode Architecture | Combination pH/ORP sensor with integrated reference system |
| Intelligent Sensor Management (ISM) | Real-time electrode health monitoring including glass membrane impedance, reference junction resistance, response time, and service life estimation |
| Temperature Compensation | Integrated Pt1000 or Pt100 RTD |
| Process Connection | Standardized ¾" NPT, DIN 19213, or sanitary Tri-Clamp fittings |
| Pressure Rating | Up to 10 bar (varies by model) |
| Temperature Range | –10 °C to +130 °C (model-dependent) |
| Certifications | ATEX/IECEx Zone 1, FM Class I Div 1, SIL2 compliant per IEC 61508, FDA 21 CFR Part 11 ready (when paired with compatible transmitter) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro2000i |
| pH Range | 0–14 |
| Temperature Range | 0–140 °C |
| Max. Pressure | 6 bar (87 psi) |
| Diaphragm Material | Ceramic |
| Reference System | Ag/AgCl with Silver Ion Trap |
| Sterilizable | Yes |
| ATEX Certification | Ex II 1/2G EEx ia IIc T6/T5/T4/T3, SNCH 00 ATEX 3130X, FM Certified for Class I, II, III Div 1 Groups A–G, T6 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro2000 / InPro2000i |
| pH Range | 0–14 |
| Temperature Range | 0–140 °C (32–284 °F) |
| Max. Pressure Rating | 6 bar (87 psi) |
| Junction | Ceramic |
| Reference System | Ag/AgCl with Silver Ion Trap |
| Sterilizable | Yes |
| ATEX Certification | Ex II 1/2G EEx ia IIc T6/T5/T4/T3, SNCH 00 ATEX 3130X FM Certified for Class I, II, III |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro3250 / InPro3250SG / InPro3250i |
| pH Range | 0–14 (InPro3250), 0–12 (InPro3253) |
| Temperature Range | 0–140 °C (32–284 °F) |
| Max. Process Pressure | 4 bar (58 psi) |
| Reference System | Ceramic junction, Ag/AgCl |
| Optional Features | Silver-ion trap (SG models), Solution Grounding (SG), ISM digital interface, ATEX certification (II 1/2G EEx ia IIC T6/T5/T4/T3), FM/CSA Class I Div 1, IP68 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro4260 |
| pH Range | 0–14 |
| Temperature Range | 0–130 °C |
| Max. Pressure | 16 bar (25 °C), 8 bar (130 °C) |
| Reference System | XEROLYT® EXTRA polymer-based electrolyte with KCl |
| Junction Type | Open liquid junction |
| Integrated Temperature Sensor | Pt100 or Pt1000 |
| ATEX Certification | II 1/2G EEx ia IIc T6–T3 |
| FM Approval | Class I, II, III |
| IP Rating | IP68 (VP connector) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro4800 |
| pH Range | 0–14 |
| Temperature Range | −5 to 130 °C |
| Max. Operating Pressure | 13 bar (at 130 °C) / 188 psi (at 266 °F) |
| Safety Factor | 3 |
| Diaphragm | External PTFE annular junction, internal non-flowing diaphragm |
| Reference System | Patented dual-gel electrolyte chamber with pressure compensation, Ag/AgCl |
| Certifications | ATEX II 1/2G Ex ia IIc T6/T5/T4, FM IS Class I, Div 1, Groups A–D |
| Compliance | IEC 60079-0, IEC 60079-11, UL 913 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | InPro5000i (for bioprocessing & cell culture), InPro5500i (for beverage carbonation) |
| Measurement Principle | Severinghaus-type electrochemical membrane sensor with temperature-compensated pH-based detection |
| Output Signal | 4–20 mA, HART, or digital ISM interface |
| Pressure Rating | Up to 10 bar (g) |
| Process Temperature Range | 0–50 °C |
| Materials of Construction | PPSU body, PTFE/PFA membranes, FDA-compliant wetted parts |
| Certifications | ATEX/IECEx Zone 1, SIL2 compliant, cGMP-ready design |
| Smart Features | ISM (Intelligent Sensor Management) with diagnostic logging, lifetime calibration tracking, and predictive maintenance alerts |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | InPro8100 Series |
| Application Domain | Bioprocess Monitoring (Microbial Fermentation & Mammalian Cell Culture) |
| Compliance | Designed for GMP/ISO 13485-aligned biomanufacturing environments |
| Installation Options | Tank-mounted, inline pipe flow cell, submersible probe |
| Measurement Principle | Near-infrared (NIR) optical absorbance at 850 nm |
| Output Signal | 4–20 mA, HART, or digital Modbus RTU/TCP |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Industrial Online Turbidimeter |
| Measurement Principle | Backscatter & Forward/90° Scatter Optical Detection |
| Sensor Types | InPro8200 (Dual-Fiber Backscatter), InPro8300RAMS (Flow-Cell Forward/90° Scatter) |
| Compliance | Designed for FDA 21 CFR Part 11, GMP/GLP environments, ASTM D6506, ISO 7027 |
| Installation Options | Reactor-mounted, Pipe-threaded (DIN/ISO/NPT), Sanitary Clamp (Tri-Clamp®), Flow Cell |
| Output Signal | 4–20 mA, HART®, Modbus RTU/TCP, EtherNet/IP™ |
| Enclosure Rating | IP66/IP68 (InPro8200), IP69K (InPro8300RAMS) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro8200 |
| Measurement Principle | Backscatter Optical Detection |
| Optical Path | Dual-Fiber Configuration |
| Measuring Range | 5–4000 FTU, 0–30 g/L (cell density) |
| Probe Length Options | 120 / 205 / 297 / 407 mm |
| Wetted Materials | ASTM A240 UNS S31603 (316L stainless steel) or UNS N10276 (Hastelloy C-276) |
| Process Connection | Pg 13.5 thread |
| Max. Operating Pressure | 16 bar (232 psi) |
| Window Material | Epoxy-sealed optical window |
| Fiber Optic Cable | Fixed 3 m dual-fiber cable with 2 FC/PC connectors |
| Probe Diameter | 12 mm |
| Compliance | Designed for GMP/GLP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InPro8400 |
| Measurement Principle | 12° forward scatter + direct transmission |
| Optical Window Material | Sapphire |
| Wetted Materials | Stainless steel (316L), sapphire, FDA-compliant polymer gasket |
| Process Connections | DIN, ANSI, APV, NPT, milk union, Tuchenhagen Varivent, Neumo BioControl, Tri-Clamp |
| Pressure Rating | 1–16 bar (14.5–232 psi) |
| Particle Detection Threshold | ≥ 0.3 µm |
| Calibration Units | FTU, EBC, ppm, g/L |
| CIP-Compatible | Yes |
| Compliance | FDA 21 CFR Part 11 ready (with appropriate software configuration), meets ISO 7027 and ASTM D6506 requirements for turbidity measurement |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iSense Asset |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | iSense Light |
| Type | Free ISM-compatible software tool |
| Licensing | No registration or certification required |
| Compatibility | Requires ISM-enabled sensors and iLink cable |
| Distribution | Imported |
| Vendor Status | Authorized Distributor |
| Pricing | Contact for quotation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | JE703/1203 |
| Type | Precision Balance |
| Max Capacity | 6100 g |
| Readability | 0.1 mg (JE703), 0.01 g (JE1203) |
| Repeatability | < 0.2 mg (JE703), < 10 mg (JE1203) |
| Calibration | Automatic internal (JE703-IC/JE1203-IC) or external |
| Temperature Compensation | Dynamic real-time |
| Connectivity | RS232 standard |
| Weighing Units | ct, g, oz, dwt, gn, momme, tola, baht, tael (user-selectable) |
| Pan Size | 90 mm (JE703), 160 mm (JE1203) |
| Overload Protection | Integrated mechanical and software-based |
| Filtering | Adaptive digital filtering with multiple stability levels |
| Power | AC adapter or rechargeable battery (JE1203 portable variant) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | JE703/1203 |
| Capacity | 70.3 g / 120.3 g |
| Readability | 0.1 mg (JE703), 0.1 mg (JE1203) |
| Repeatability | ≤0.2 mg |
| Linearity | ≤0.4 mg |
| Pan Size | Ø90 mm |
| Calibration | Internal (IC) or External |
| Compliance | ISO/IEC 17025, ASTM E899, USP <41>, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | LA Series |
| Maximum Capacity | 82 g to 4200 g |
| Readability | 0.1 mg to 10 mg |
| Repeatability (5% load) | 0.1 mg / 1 mg / 10 mg (typical: 0.08 mg / 0.7 mg / 7 mg) |
| Linearity Error | 0.2 mg / 2 mg / 20 mg (typical: 0.08 mg / 0.6 mg / 6 mg) |
| Minimum Weight (USP, ±0.10%) | 160 mg / 1.4 g / 14 g |
| Minimum Weight (±1%) | 16 mg / 0.14 g / 1.4 g |
| Stabilization Time | 3 s |
| Dimensions (W × D × H) | 210 × 308 × 345 mm (LA84E–LA4002E) |
| Pan Diameter | 80 mm / 100 mm / 180 mm |
| Weighing Principle | Electromagnetic Force Compensation (EMFC) |
| Interface | RS232, optional Bluetooth |
| Software | MT-SICS, EasyDirect™ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | LA204/A |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Accuracy (Linearity) | ±0.2 mg |
| Repeatability | ≤0.08 mg |
| Calibration | Internal motorized calibration with built-in weights |
| Weighing Units | g, mg, kg, oz, ct, etc. |
| Draft Shield | Integrated glass draft shield |
| Compliance | Designed to support GLP/GMP documentation requirements and ISO/IEC 17025-compliant workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Service Type | Instrument Calibration |
| Instrument Type | Analytical Instruments |
| Service Experience | 100 Years |
| Response Time | Within 24 Hours |
| Certification/Calibration Scope | Traceable calibration ensuring reliable weighing results compliant with local and international regulatory requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Laboratory Equipment Calibration Service |
| Service Type | Instrument Calibration |
| Instrument Types | General Laboratory Equipment |
| Industry Experience | 100 Years |
| Response Time | Within 24 Hours |
| Scope of Calibration | Comprehensive metrological verification and uncertainty evaluation for laboratory weighing instruments and ancillary measurement devices |
| Compliance Coverage | ISO/IEC 17025, ASTM E898, USP <41>, EU GMP Annex 11, FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP traceability requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Laboratory Instrument Maintenance and Repair Service |
| Quotation | Upon Request |
| Service Fee | USD 7,000–14,000 (approx.) |
| Technical Experience | 100 years in precision instrumentation support |
| Instrument Scope | General-purpose laboratory instruments (balances, pipettes, pH meters, titrators, thermal analyzers, etc.) |
| Response Time | Within 0–24 hours |
| Service Coverage | Nationwide (China) |
| Compliance Framework | ISO/IEC 17025-aligned procedures, traceable to METTLER TOLEDO global service standards |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Compatibility | Titration, Moisture Analysis, Density & Refractometry, Melting Point, UV/Vis Spectrophotometry, pH/Conductivity, Analytical & Precision Balances, Automated Dispensing Systems |
| Architecture | Client-Server |
| Base Instrument Licenses | 11 |
| Additional Instrument Licenses (any type) | up to 360 |
| Regulatory Compliance | FDA 21 CFR Part 11, ALCOA+ principles, GLP/GMP-ready |
| Software Modules | User Management, Auto Import/Export, Product Database, Regulatory Module, Advanced Report Designer, System Integration, Statistical Evaluation, STAReX Integration, OpenLab CDS Interface |
| Supported Instruments | T50/T70/T90/T5/T7/T9/G20/G20S, V20/V30/C20/C30/V20S/V30S/C20S/C30S, DM40/DM45/DM50/RM40/RM50/DX40/DX45/DX50/RX40/RX50/D4/D5/D6/R4/R5/RX4/RX5, MP70/MP80/MP90, UV5/UV7/UV5Bio/UV5Nano, XP/XS/XPE/XSE/XPR/XSR, SevenExcellence™, Quantos™ |
| Deployment | Network-based, centralized SQL database, domain-authenticated access |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | LabX® Software |
| Type | Laboratory Information Management System (LIMS) / Instrument Control & Data Management Platform |
| Regulatory Compliance Support | 21 CFR Part 11, Annex 11, GLP/GMP-ready |
| Deployment | Client-server or cloud-hosted architecture |
| Integration Capability | Native drivers for METTLER TOLEDO balances, titrators, pH meters, melting point apparatuses, thermal analyzers, and third-party instruments via OPC UA, ASCII, or TCP/IP protocols |
| User Management | Role-based access control (RBAC), electronic signatures, audit trail with immutable timestamped records |
| Reporting | Customizable PDF/Excel reports with metadata embedding and digital signature support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Beijing, China |
| Model | LE104E |
| Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Calibration | External |
| Pan Diameter | 80 mm |
| Power Supply | AC Mains |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Beijing, China |
| Model | LE2002E |
| Type | Analytical Balance |
| Max Capacity | 2200.0 g |
| Readability | 0.01 g |
| Accuracy | ±0.02 g |
| Repeatability | ±0.01 g |
| Calibration | External |
| Pan Size | 180.0 mm |
| Power Supply | AC Mains |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-sourced) |
| Model | LE203E |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 1.0 mg |
| Calibration Method | External |
| Pan Diameter | 100 mm |
| Power Supply | AC Mains |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | LE3002E |
| Type | Precision Balance |
| Max Capacity | 3200.0 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | External |
| Pan Size | 180.0 mm |
| Power Supply | AC |
