METTLER TOLEDO
Filter
Showing 451–480 of 567 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T5 / T7 / T9 |
| Measurement Range | ±2000 mV / −26.0 to +40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T50 / T70 / T90 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | −2000 to +2000 mV |
| Titration Resolution | 0.1 mV |
| Electrode Interfaces | pH/mV, Conductivity, Coulometric (modular) |
| Built-in Titration Drivers | 1 internal + up to 7 external (T90) |
| Sample Capacity per Series | up to 300 samples |
| Method Storage Capacity | 100 methods |
| Communication Interfaces | Ethernet, USB Host (3×), USB Client (1×), RS-232 (COM, 3–5 ports), CAN Bus (optional) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T7 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | ±2000 mV / –26.0 to 40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T7 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Measurement Range | −2000 to +2000 mV |
| Meter Accuracy | ±0.2 mV |
| Meter Resolution | 0.1 mV |
| Titration Precision | ±0.2 mV |
| Compliance | Designed for GLP/GMP environments with full audit trail support per FDA 21 CFR Part 11 requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T7 |
| Measurement Range | −2000 to +2000 mV |
| Meter Accuracy | ±0.2 mV |
| Meter Resolution | 0.01 mV |
| Burette Precision | ±0.3% (v/v) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T9 |
| Titration Type | Universal Potentiometric Titrator |
| Measurement Range | ±2000 mV / −26.0 to +40.0 pH |
| Meter Accuracy | 0.01% |
| Meter Resolution | 0.1 mV / 0.001 pH |
| Titration Precision | 0.2 mV / 0.003 pH |
| Integrated Burettes | 1 internal + 7 external |
| Parallel Titration Capability | Yes (up to 30 tasks, max 8 concurrent) |
| GLP Compliance | Yes |
| Software Logic | IF…THEN conditional method control |
| Supported Techniques | Acid-base, redox, complexometric, non-aqueous, photometric, coulometric & volumetric Karl Fischer titration |
| Auto-sampler Compatibility | InMotion™, Rondolino, Stromboli |
| Sensor Interfaces | Up to 3 sensor boards, plug-and-play sensors |
| Language Support | English, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese, Chinese |
| User Profiles | Password-protected, role-based access control |
| Connectivity | USB (printer, barcode scanner), RS-232 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | T9 |
| Measurement Range | −2000 to +2000 mV |
| Meter Accuracy | ±0.2 mV |
| Meter Resolution | 0.01 mV |
| Titration Precision | ±0.3 µL |
| Titrant Drive Units | 1 internal + 7 external |
| Parallel Titration Capacity | up to 30 tasks, 8 concurrent |
| IF-THEN Logic Support | Yes |
| GLP Compliance | Yes |
| Language Support | English, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese, Chinese |
| Interface | USB (printer, barcode reader), RS-232 |
| SmartSample Integration | Yes |
| Auto Electrode & Burette Recognition | Yes |
| InMotion™ Auto-sampler Compatible | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | Tablex2 |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Pre-sterilized, Recyclable Tip Rack System |
| Material Composition | Primarily PETE (Polyethylene Terephthalate) |
| Sterilization | Gamma-irradiated, ISO 11137 compliant |
| Environmental Certification | 100% recyclable per ISO 14021 |
| Packaging Efficiency | 50% less plastic vs. conventional tip racks |
| Compressibility | High — post-use volume reduction >60% in waste stream |
| Regulatory Compliance | Meets EU Directive 2002/96/EC (WEEE) and EN 13432 for recoverability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Excellence |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Heat Flow Resolution | 0.00003 °C |
| Enthalpy Accuracy (metal standards) | ±1% |
| Compliance | ASTM E1131, ISO 11358, USP <1234>, FDA 21 CFR Part 11 (with optional audit trail) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 Professional |
| Temperature Range | RT to 1100 °C or RT to 1600 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| DSC Sensor | Dual Pt–Pt/Rh thermocouples |
| Calorimetric Temperature Resolution | 0.0001 °C |
| Calorimetric Accuracy (metal standards) | ±2% |
| Compliance | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1 |
| Temperature Range | RT to 1600 °C |
| Mass Resolution | Sub-microgram |
| Automation | Integrated Robotic Sample Changer |
| 炉 Atmosphere Control | Hermetic Furnace Design |
| Coupling Compatibility | MS and FTIR for Evolved Gas Analysis |
| Modular Architecture | Field-upgradable Hardware Modules |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1100 |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.25 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-disk SDTA with Pt–Pt/Rh thermocouples |
| Modular Configuration | Optional autosampler, vacuum pump, MS/FTIR coupling, humidity control module |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 1/1600 |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.5 °C |
| Balance Sensitivity | 0.1 µg or 0.01 µg |
| Baseline Repeatability | ±10 µg (full temperature range) |
| Sensor Type | Single-Pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 2 |
| Instrument Type | Universal |
| Temperature Range | RT to 1100 °C or 1600 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (model-dependent) |
| Heating/Cooling Rate | 0.02–150 K/min (standard furnace) / up to 250 K/min (fast furnace) |
| Dynamic Weighing Range | 1 g / 5 g (model-dependent) |
| Balance Accuracy | 0.005% |
| Balance Precision | 0.0025% |
| Resolution | Sub-microgram across full weighing range |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Advanced |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt-Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Standard |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1163>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02–150 K/min / 0.02–250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Sample Capacity | Multi-sample (with optional autosampler) |
| Instrument Type | Modular, general-purpose simultaneous TGA/DSC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA/DSC 3+ Standard |
| Temperature Range | RT to 1100 °C / 1600 °C |
| Temperature Accuracy | ±0.05 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.02 to 150 K/min / 0.02 to 250 K/min |
| DSC Sensor | 6-pair Pt/Pt–Rh thermocouples |
| Simultaneous Measurement Capability | Yes |
| Modular Configuration | Yes |
| Compliance Ready | ASTM E1131, ISO 11358, USP <1227>, FDA 21 CFR Part 11 (with optional software module) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 LF (Large Furnace) / TGA2 SF (Small Furnace) |
| Temperature Range | Up to 1100 °C (LF), Up to 600 °C (SF) |
| Temperature Accuracy | ±0.5 K |
| Balance Sensitivity | 0.1 µg |
| Heating/Cooling Rate | 0.001–100 K/min |
| Furnace Type | Dual-furnace modular architecture |
| Compliance | ASTM E1131, ISO 11358, USP <41>, FDA 21 CFR Part 11 ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | RT to 1100 °C |
| Balance Sensitivity | 0.1 µg / 1 µg (depending on balance module) |
| Heating/Cooling Rate | 0.02 to 150 K/min |
| Temperature Accuracy | ±1 K |
| Blank Curve Repeatability | < ±10 µg across full temperature range |
| Sensor Type | Single-pan SDTA (Simultaneous Differential Thermal Analysis) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TGA2 |
| Temperature Range | 30 °C – 1,100 °C |
| Sampling Rate | 10 data points/second |
| Atmosphere Control | Integrated Mass Flow Controller (MFC) for programmable gas switching |
| Buoyancy Correction | Automatic, model-based, no blank required |
| One-Click Method Launch | Yes |
| Optional Couplings | FTIR, MS, Micro GC, GC/MS |
| Sensor Output | Mass & Temperature |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Product Type | Technical Reference Handbook |
| Model | Thermal Analysis Application Handbook – Evolved Gas Analysis |
| Compliance | Compatible with TGA-FTIR and TGA-MS coupling configurations per ISO 11358, ASTM E1131, and USP <1031> guidelines |
| Format | Printed and digital PDF (English edition) |
| Intended Use | Method development & interpretation support for thermal decomposition gas-phase characterization |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Distribution Type | Authorized Distributor |
| Product Category | Thermal Analyzer Accessory / Reference Publication |
| Model | Thermal Analysis Application Handbook Series – Thermoplastic Polymers |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Thermal Analysis Application Handbook Series – Thermosetting Resins |
| Price | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Product Type | Technical Reference Handbook |
| Model | Thermal Analysis Applications Handbook – Elastomers |
| Language | English |
| Format | Printed Book + Digital PDF (upon request) |
| Compliance | Aligned with ISO 11357, ISO 11358, ASTM D3418, ASTM E1356, USP <1159> |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 2300Na |
| Measurement Range | 0.001–100,000 ppb Na⁺ |
| Calibration | Unattended 3-point incremental or manual 1-/2-point |
| Dimensions | 900 × 450 × 190 mm |
| Analog Outputs | (4) 0/4–20 mA |
| Electrode Activation | Automatic during calibration |
| Enclosure Options | Fully enclosed locked cabinet or semi-enclosed with service door |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 2800Si |
| Detection Limit | 0.8 ppb |
| Measurement Range | 0–5000 ppb |
| Accuracy | ±5% of reading or ±1 ppb (whichever is greater) |
| Cycle Time | Adjustable, typically 20 minutes |
| Maximum Sample Pressure | <7 bar (100 psig) |
| Compliance | Designed for ASTM D4582, ASTM D5116, ISO 14687-2, and power plant water chemistry guidelines per EPRI TR-102328 & IAPWS RP-7 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 4000TOCe |
| Instrument Type | Online TOC Analyzer |
| Measurement Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.05–1000 ppb C |
| Accuracy | ±0.1 ppb (TOC < 2 ppb) |
| Resolution | 0.001 ppb |
| Detection Limit | 0.025 ppb |
| Repeatability | ±0.05 ppb (<5 ppb) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 450TOC |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.05 – 1000 ppb C (μg C/L) |
| Accuracy | ±0.1 ppb C for TOC < 2.0 ppb |
| Resolution | 0.001 ppb C (μg C/L) |
| Detection Limit | 0.025 ppb C |
| Repeatability | ±0.05 ppb C (< 5 ppb), ±1.0% (> 5 ppb) |
| Sample Temperature | 0–70 °C |
| Particle Size Limit | < 100 µm |
| Conductivity Requirement | ≥0.5 MΩ·cm (≤2 µS/cm) |
| pH Limit | < 7.5 |
| Flow Rate | 20 mL/min |
| Inlet Pressure | 4–85 psig (0.3–5.8 bar) |
| Dimensions | 334 × 185 × 324 mm |
| Weight (with base) | 7.0 kg |
| Enclosure Material | UL 94 V-0 Flame-Retardant Polystyrene |
| Wetted Materials | 316 Stainless Steel, Quartz, PEEK, Titanium, PTFE, Silicone, FFKM, EPDM |
| Environmental Operating Range | 5–50 °C / 5–80% RH (non-condensing) |
| Power | 100–240 VAC, 50/60 Hz, max. 40 W |
| Certifications | CE, cULus |
| Traceability | NIST-traceable conductivity & temperature sensors per ASTM D1125 and D5391 |
| Compliance | ASTM D5173, USP <643>, EP 2.2.44, JP 2.59, ChP 0912 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 770MAX |
| Input Channels | 6 (up to 16 measured parameters) |
| Sensor Types Supported | 8 (e.g., conductivity/resistivity, pH/ORP, dissolved oxygen, ozone, TOC, flow, temperature, pressure, level) |
| Output Options | 4 or 8 × 0/4–20 mA analog outputs |
| Communication | RS232 serial interface |
| Relay Outputs | 4 (optional) |
| Display | Multi-line scrolling LCD with customizable parameter naming |
| Power Supply | Universal 100–240 VAC, 50–60 Hz |
| Enclosure | 1/4 DIN, IP65-rated with sealed rear cover |
| Calibration Support | NIST-traceable verification via optional 1875 Smart Calibrator |