METTLER TOLEDO
Filter
Showing 481–510 of 567 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 770MAX |
| Input Channels | 6 (up to 16 measurement results) |
| Sensor Types Supported | 8 (including pH/ORP, conductivity/resistivity, dissolved oxygen, ozone, TOC, flow, temperature, pressure, level) |
| Output Options | 4 or 8 analog outputs (0/4–20 mA), RS232 serial interface, up to 4 relay outputs (optional) |
| Display | Multi-line scrolling LCD with customizable parameter labeling |
| Power Supply | Universal AC 100–240 V, 50–60 Hz |
| Enclosure | 1/4 DIN, IP65-rated front panel, sealed rear cover |
| Calibration | NIST-traceable verification & calibration via optional 1875 Smart Calibrator |
| Smart Sensor Compatibility | Thornton intelligent sensors with embedded NVRAM for auto-recognition, calibration data storage, and plug-and-play operation |
| Measurement Units | 35 configurable units across parameters |
| Temperature Compensation | Integrated, parameter-specific algorithms |
| Data Timestamping | Internal real-time clock for all measurements and calibration events |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | InPro7250 Series |
| Sensor Principle | Toroidal (Electrodeless) Induction |
| Measurement Parameters | Conductivity, Resistivity, Salinity (TDS-derived), Temperature |
| Output Protocols | HART, PROFIBUS PA, FOUNDATION Fieldbus |
| Enclosure Rating | IP66/IP67, ATEX/IECEx Certified Options Available |
| Channel Configuration | Single- or Dual-Channel Transmitter Options |
| Compliance | FDA 21 CFR Part 11 (with ISM software), ASTM D1125, ISO 7888, USP <645>, EP 2.2.38 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA 2+ IC/600 / LF/1100 / LN/600 |
| Temperature Range | –80 to 600 °C |
| Temperature Accuracy | ±0.005 °C |
| Force Range | –0.1 to 1 N |
| Displacement Resolution | 0.5 nm |
| Frequency Range | 0.01–1 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | LF/1100, HT/1600, IC600, LN600 |
| Temperature Range | –150 °C to 1600 °C |
| Temperature Accuracy | ±0.005 °C |
| Force Resolution | 0.01–1 Hz (dynamic frequency range) |
| Displacement Range | 20 mm |
| Length Resolution | 0.5 nm |
| Operating Modes | Compression, Tension, Penetration, Expansion |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA840, TMA/SDTA841e |
| Temperature Range | −150–600 °C (TMA/SDTA841e), RT–1100 °C (TMA/SDTA840) |
| Temperature Accuracy | ±0.25 °C |
| TMA Resolution | 1 nm (TMA/SDTA841e), 10 nm (TMA/SDTA840) |
| Measurement Modes | Expansion, Penetration, Bending, Tension, Dynamic Load TMA (DLTMA) |
| SDTA Capability | Yes |
| Environmental Control | Hermetic sample chamber |
| Coupling Options | MS, FTIR |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TMA/SDTA861e |
| Temperature Range | −150 to 600 °C (standard), up to 1100 °C with gas-tight furnace option |
| Temperature Accuracy | ±0.5 °C |
| Force Range | 0.001–40 mN |
| Displacement Range | ±1.6 mm |
| Frequency Range | 0.001–1000 Hz |
| Resolution | 1 nm |
| Measurement Modes | Static TMA, Dynamic Load TMA (DLTMA), Simultaneous Differential Thermal Analysis (SDTA) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TOPEM™ TMDSC |
| Category | Imported Instrument |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TT DMA |
| Temperature Range | −190 °C to 600 °C |
| Frequency Range | 0.001 Hz to 1000 Hz |
| Fixture Configurations | Dual-cantilever, single-cantilever, 3-point bending, shear, tension, compression |
| Operating Modes | Creep, constant-force (TMA), stress–strain, stress relaxation, isothermal, step-isothermal, multi-ramp thermal profiles |
| Environmental Options | Humidity chamber (up to 85 °C / 85 % RH), liquid immersion cell, gas purge (N₂, air, Ar) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Laboratory Service |
| Service Model | Customized Training & Process Consulting |
| Training Experience | 10+ Years |
| Equipment Scope | Laboratory Weighing, In-line Process Analytics, Calibration & Metrology Systems |
| Pricing | Upon Consultation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV-DSC1 |
| Temperature Range | −150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| UV Wavelength Range | 240–400 nm (optional extension to 400–700 nm, visible) |
| UV Irradiance | 4500 mW/cm² (at 365 nm) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | UV5 |
| Wavelength Range | 190–1100 nm |
| Detector Type | CCD (Charge-Coupled Device) |
| Optical Design | Dual-Wavelength |
| Wavelength Accuracy | ±1.0 nm |
| Measurement Speed | Full-spectrum scan in <1 second |
| Light Source | Xenon flash lamp |
| Warm-up Time | Zero |
| Automation Level | Fully automated wavelength selection and measurement execution |
| Sample Compartment | Open-access, motor-free design |
| Software Platform | LabX UV-Vis PC software (21 CFR Part 11 / EU Annex 11 compliant) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5, UV7 |
| Optical Design | Single-beam with pulsed xenon lamp |
| Detector | 2048-pixel CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm (UV5), ±0.8 nm (UV7) |
| Stray Light | <0.01% T at 198 nm (KCl) |
| Scan Speed | Full spectrum in ≤1 s |
| Photometric Accuracy | ±0.01 A (K₂Cr₂O₇) |
| Wavelength Resolution (toluene in n-hexane) | >1.5 nm (UV5), >1.9 nm (UV7) |
| Display | 7″ QVGA color TFT touchscreen (400 × 800 px) |
| Dimensions (L×W×H, without controller) | 208 × 255 × 228 mm |
| Weight (with controller) | 6.4 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5 / UV7 / UV5Bio |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.9 nm |
| Spectral Bandwidth | 1 nm |
| Stray Light | <0.03% T (at 220 nm, KI solution) |
| Automation Level | Automatic Wavelength Selection |
| Lamp Type | Xenon Flash Lamp |
| Warm-up Time | None |
| Dimensions | Compact footprint (~A4 size) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV5Bio / UV5Nano |
| Optical Design | Dual-wavelength |
| Detector | CCD array |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light (at 198 nm, KCl) | >2.0 A |
| Scan Time (full spectrum) | 1 s |
| Automation | Automatic wavelength selection, integrated cuvette changer, FillPalMini peristaltic pump |
| Compliance | ASTM E275, ISO 6425, USP <857>, FDA 21 CFR Part 11 ready (via LabX®) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | UV5Nano |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 190 nm – 1,100 nm |
| Wavelength Automation | Automatic |
| Spectral Bandwidth | 1.5 nm |
| Wavelength Accuracy | ±0.9 nm |
| Stray Light | <0.03% T (at 220 nm, KI solution) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UV5Nano |
| Instrument Architecture | Dual-wavelength |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190 nm – 1,100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Photometric Accuracy (K₂Cr₂O₇) | ±0.01 A |
| Path Length Options | 0.1 mm and 1.0 mm |
| Cuvette Holder | Yes |
| Automation Level | Automatic Wavelength Selection |
| Sample Volume Requirement | As low as 0.3 µL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | V20S |
| Titration Method | Volumetric Karl Fischer |
| Display | 7-inch full-color capacitive touchscreen |
| User Interface Languages | Chinese, English, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese |
| Connectivity | USB, Ethernet (TCP/IP), LabX PC software compatible |
| Preloaded Methods | Up to 5 user-defined methods |
| Customizable One Click™ shortcuts | Up to 12 per user |
| Compliance | Designed for ISO/IEC 17025, ASTM E203, USP <921>, EP 2.5.12, and FDA 21 CFR Part 11-ready environments (when used with LabX) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Model | V20S |
| Moisture Range | 10 ppm to 100% (w/w) |
| Accuracy | ±0.3% relative |
| Minimum Dispensing Volume | 1 µL |
| Compliance | ASTM E203, ISO 760, USP <921>, EP 2.5.12, GLP/GMP-ready |
| Software | titrando® with One Click™ workflow engine |
| Electrode Options | Membrane-free or membrane-separated generator electrodes |
| Solvent Management | Integrated Solvent Manager with LevelSens™ level monitoring |
| Sample Introduction | Direct addition, oven coupling (up to 300 °C), and headspace extraction |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 ppm to 100% (w/w) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Drive Precision | 20,000 steps per revolution |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric/Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 ppm to 100% (V20S: volumetric |
| V30S | coulometric, down to 1 ppm) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Control Precision | 20,000 steps |
| Compliance | Designed for GLP/GMP environments with audit trail capability per FDA 21 CFR Part 11 requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Moisture Range | 10 ppm to 100% |
| Resolution | 0.1 µL (burette resolution) |
| One-Click Method Shortcuts | 12 (V20S), 4 (V30S), 12 (C10S), 12 (C20S), 12 (C30S) |
| Solvent Manager | Hardware-integrated, hot-pluggable |
| Smart Burette | RFID-enabled, auto-recognized |
| User Management | 4-level permission system with password protection |
| Software Integration | LabX Express / LabX Server via USB or TCP/IP |
| GLP-Compliant Printing | USB printer or METTLER TOLEDO P25 thermal printer |
| Optional Automation | InMotion KF Heated Autosampler |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 mV |
| Moisture Range | 10 ppm to 100% (w/w) |
| Accuracy | ±0.3% (for samples containing >10 mg H₂O) |
| Minimum Dispensing Volume | 0.05 µL |
| Titration Control Precision | 20,000 steps |
| Supported Languages | 10 (English, German, French, Italian, Spanish, Chinese, Russian, Polish, Korean, Portuguese) |
| Preloaded Methods | 11 METTLER TOLEDO Expert Methods |
| User-Defined Methods | Up to 100 |
| Task Queue Capacity | 10 tasks |
| Optional Dryer | DO308 (manual) or Stromboli (automated, 14-position) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model Series | WMC / PDX / FWC |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HX204 / HS153 / HB43 |
| Readability | 0.1 mg / 1 mg |
| Moisture Content Readability | 0.001% / 0.01% |
| Repeatability (sd, 2 g sample) | 0.05% / 0.05% / 0.10% |
| Repeatability (sd, 10 g sample) | 0.01% / 0.01% / 0.02% |
| Weighing Range | 200 g / 150 g / 54 g |
| Temperature Range | 40–230 °C / 40–230 °C / 50–230 °C |
| Heating Source | Second-generation halogen lamp |
| Calibration | FACT® automated temperature-triggered calibration (HX204 only) |
| Drying Programs | Standard, Gentle, Rapid, Step (HX204) |
| Method Storage | 300 / 99 / 100 |
| Real-time drying curve display | Yes / Yes / No |
| LevelControl™ | Active (HX204) / Visual indicator (HS153/HB43) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Country of Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X12 X-ray Inspection System User Guide |
| Training Experience | 10+ Years |
| Instrument Type | Physical Property Testing Instrument |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | United Kingdom |
| Model | X3305 |
| IP Rating | IP65 (standard), IP69K (optional) |
| X-ray Source Power | 20 W |
| System Length | 1.8 m |
| Compliance | GMP, NSF/ANSI 169, EHEDG Guideline Doc. 8.2 |
| Application Scope | Small-to-medium packaged food, pharmaceutical, and consumer goods |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | XG 300/6 |
| Throughput | Up to 120 pcs/min |
| Max. Product Weight | 300 g |
| Max. Product Length | 250 mm |
| Standard Weight Zones | 6 (expandable to 12) |
| IP Rating | IP65 |
| Construction | Stainless Steel Frame + Food-Grade Polyoxymethylene (POM) Conveyor Belt |
| Interface | RS232 (compatible with METTLER TOLEDO Garvens checkweighers) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | XP Micro Balance |
| Readability | down to 0.001 mg |
| Repeatability (sd) | as low as 0.002 mg |
| Linearity error | ≤ 0.006 mg |
| Typical stabilization time | 3.5 s |
| Pan dimensions | 40 × 40 mm |
| Compliance | GWP® Excellence, USP <41>/<1251>, ISO/IEC 17025, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Range | XP105DR, XP205, XP205DR, XP204, XP504, XP504DR |
| Maximum Capacity | 31 g / 120 g to 101 g / 520 g |
| Readability | 0.01 mg to 1 mg |
| Repeatability (sd) | 0.015 mg – 0.6 mg |
| Linearity Error | 0.1 mg – 0.5 mg |
| Eccentricity Error | 0.2 mg – 0.5 mg |
| Sensitivity Drift | 2 × 10⁻⁶ to 4 × 10⁻⁶ × Rnt |
| Temperature Coefficient of Sensitivity | 1 × 10⁻⁶ /°C × Rnt |
| Stability | 1 × 10⁻⁶ /a × Rnt |
| Typical Stabilization Time | 1.5 s – 2.5 s |
| Six Preloaded Applications | Weighing, Counting, Percentage, Density, Statistics, Formulation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Variants | XP26 / XP56 / XP26DR / XP56DR / XP6 / XP2U / XP6U |
| Maximum Capacity | 2 g – 5 g |
| Readability | 0.000001 g (1 µg) |
| Repeatability | ≤ ±0.001 mg |
| Calibration | Fully Automatic proFACT Technology (Temperature- and Time-Triggered Internal Calibration) |
| Compliance | GxP, USP <41>, USP <1251>, ISO/IEC 17025, GLP/GMP Audit Trail Ready |
| Sample Pan | SmartGrid Mesh Pan (XP26/XP56 only) |
| Interface | RS232 Standard + Modular Communication Slot (Bluetooth / Ethernet / LocalCAN / PS/2 Optional) |
| Display | 4.3″ TFT Color Touchscreen with SmartScreen UI |
| Environmental Monitoring | LevelControl Auto-Leveling Alert System |
| Regulatory Features | MinWeigh Function (GWP® Verified), BalanceCheck Prompt, GWP® Excellence Integrated Risk Management |