METTLER TOLEDO
Filter
Showing 91–120 of 567 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Range | 10 ppm to 100% |
| Measurement Resolution | ±2300 mV / 0.1 mV |
| Detection Limit | 0.1 µg H₂O |
| Minimum Water Delivery | 0.2 mg per sample (RSD ≤ 1%) |
| Titration Precision | 120,000 steps |
| Titration Mode | Fully Automated Volumetric Titration |
| Compliance | FDA 21 CFR Part 11, ISO/IEC 17025, ASTM E203, USP <921>, EP 2.5.12 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland (manufactured in METTLER TOLEDO facilities) |
| Instrument Type | Volumetric Karl Fischer Titrator with Integrated Heated Autosampling System |
| Compliance | ASTM D6304, ISO 8534, USP <921>, EP 2.5.12, GLP/GMP-ready |
| Sample Capacity | 26 positions (heated sample carousel) |
| Temperature Control Range | Ambient to 150 °C (adjustable per vial) |
| Titration Resolution | 0.001 mL reagent dispense |
| Reagent Delivery | Dual-piston burette with integrated moisture-tight sealing |
| Software Platform | LabX® with 21 CFR Part 11 compliance, audit trail, electronic signatures |
| Connectivity | Ethernet, USB, RS-232 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Manufactured in China (for global distribution) |
| Manufacturer Type | Authorized Distribution Channel |
| Model | EVA V1 |
| Pricing Range | USD 19,500 – 22,000 (FOB) |
| Titration Principle | Volumetric Coulometric/KF Endpoint Detection via Bipotentiometric Electrode System |
| Dispensing Resolution | 120,000 steps per burette revolution |
| Control Algorithm | Fast Feedback Algorithm (FFA) for dynamic reagent dosing |
| Software Platform | LabX™ PC-based titration software with audit trail and electronic signature support |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EVA V1/V3 |
| Application Scope | Liquid and soluble solid samples |
| Titration Principle | Volumetric Karl Fischer (Iodine-based redox titration) |
| Electrode Type | Digital polarizable dual-platinum electrode |
| Control Algorithm | Fast Forward Algorithm (FFA) for real-time current-based endpoint prediction |
| Sample Weight Transfer | Direct integration with METTLER TOLEDO balances via RS232/USB |
| Data Export | CSV, PDF via Ethernet or USB drive |
| Printer Support | METTLER TOLEDO thermal & dot-matrix printers (A4/letter) |
| Software Platform | LabX™ PC-based software with optional Active Directory integration |
| Security Features | User-level access control, audit trail, 21 CFR Part 11–compliant electronic signatures (with LabX validation package) |
| Solvent Handling | Fully automated solvent exchange and burette purging |
| Optional Accessories | Homogenizer kit, micro-vial holders, 2.5 m remote terminal cable for fume hood operation |
| Reproducibility | ≤0.3% RSD for triplicate analysis under GLP conditions |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Manufactured in China (for global distribution) |
| Manufacturer Type | Authorized Distribution Channel |
| Model | EVA V3 |
| Pricing Range | USD 24,000 – 27,000 (FOB) |
| Titration Principle | Volumetric Karl Fischer (KF) |
| Electrode Type | Dual-platinum generator and indicator electrodes |
| Reagent Delivery Precision | ±0.001 mL per 120,000-step motorized burette |
| Sample Throughput | Up to 30 samples per hour (with autosampler option) |
| Compliance | Fully compatible with FDA 21 CFR Part 11, ISO/IEC 17025, and GLP/GMP data integrity requirements |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Refractive Index (nD) Range | 1.3200–1.7000 |
| Brix Range | 0–100% w/w |
| nD Accuracy | ±0.0001 (near calibration point), ±0.00002–±0.00004 (full range) |
| nD Repeatability | ±0.00005 (R4), ±0.00001 (R5) |
| nD Resolution | 0.0001 (R4), 0.00001 (R5) |
| Brix Accuracy | ±0.05% (R4), ±0.014% (R5) |
| Brix Repeatability | ±0.05% (R4), ±0.01% (R5) |
| Temperature Range | 5–100 °C (R4), 5–75 °C (R5) |
| Temp. Accuracy | ±0.1 °C (5–100 °C, R4), ±0.03 °C (15–50 °C, R5), ±0.05 °C (5–75 °C, R5) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Benchtop Refractometer |
| Temperature Control | Yes |
| Digital Display | Yes |
| Measurement Range | 0–100 % w/w (Brix or refractive index equivalent) |
| Accuracy | ±0.05 % w/w |
| Compliance | FDA 21 CFR Part 11 ready (with LabX software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP55 / MP70 / MP80 / MP90 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Capillary Diameter Compatibility | <1.8 mm |
| Sample Capacity | Up to 6 samples simultaneously |
| Compliance | GLP/GMP-ready, ISO/IEC 17025-aligned calibration traceability |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MP70 / MP90 |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Sample Capacity | Up to 6 capillaries per run |
| Compliance | USP <741>, Ph. Eur. 2.2.14, JP 17, ISO 11357-3, ASTM D1519 |
| Safety | Integrated optical monitoring with simultaneous transmittance measurement and reflected-light imaging |
| User Interface | One Click® color touchscreen with pre-stored method recall |
| Qualification Support | Factory-supplied IQ/OQ documentation and on-site qualification services available |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Temperature Range | RT to 350 °C |
| Heating Rate | 0.1 to 20 °C/min |
| Temperature Accuracy | ±0.2 °C (30–200 °C), ±0.5 °C (200 °C to Tmax) |
| Sample Capacity | Up to 4 samples |
| Display | 5.7" VGA color touch screen |
| Video Resolution | Color AVI, >6× magnification |
| Data Export | PDF reports, GLP/GMP-compliant audit trail |
| Compliance | 21 CFR Part 11 ready (with LabX software) |
| Power Consumption | 120 W |
| Dimensions | 18 × 35 × 19 cm |
| Weight | 4.4 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Benchtop |
| Model | FE20 |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| Relative pH Accuracy | ±0.01 |
| mV/ORP Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| Relative mV Accuracy | ±1 mV |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with 4 pre-defined buffer sets |
| Display | LCD |
| Power Supply | External AC adapter |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE20K |
| Instrument Type | Benchtop (not portable) |
| Parameter Type | Single-parameter (pH/mV/ORP) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 mV |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with auto-buffer recognition for 4 pre-defined IUPAC/NIST-compatible buffers |
| Data Storage | 99 measurement records |
| Interface | RS232 |
| Display | Backlit LCD showing pH/mV value, temperature, endpoint status, and calibration indicators |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE28 / S210-K |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH + mV/ORP) |
| pH Range | −2.00–16.00 pH (FE28) / −2.000–20.000 pH (S210-K) |
| pH Resolution | 0.01 pH (FE28) / 0.001–0.1 pH selectable (S210-K) |
| pH Accuracy | ±0.01 pH (FE28) / ±0.002 pH (S210-K) |
| mV Range | ±2000 mV (FE28) / ±2000.0 mV (S210-K) |
| mV Resolution | 1 mV (FE28) / 0.1 or 1 mV selectable (S210-K) |
| mV Accuracy | ±1 mV (FE28) / ±0.2 mV (S210-K) |
| Temperature Range | −5 to 105 °C (FE28, manual/auto) / −30.0 to 130.0 °C (S210-K, manual) |
| Temperature Accuracy | ±0.1 °C (S210-K) |
| Calibration Points | Up to 5-point pH calibration |
| Buffer Recognition | Automatic (NIST, DIN, JIS, ISO, METTLER TOLEDO standard buffers) |
| Data Storage | 200 measurement records |
| Connectivity | RS232 and USB |
| Electrode Interface | Standard BNC (FE28) / ISM-enabled Smart Socket (S210-K) |
| Temperature Compensation | Automatic and manual |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | FE28-Meter |
| Instrument Type | Portable |
| Parameter Types | pH, Conductivity, Dissolved Oxygen |
| pH Measurement Range | −2.00 to 16.00 |
| pH Resolution | 0.01 |
| pH Accuracy | ±0.01 (at 25 °C) |
| pH Calibration Points | Up to 5 |
| Predefined Buffer Sets | 4 |
| Temperature Range | 0 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Compensation | Automatic (ATC) and Manual (MTC) |
| Data Storage | 200 measurement records + active calibration data |
| Interface | RS232 and USB |
| Reference Input | Yes |
| Audible Signal | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Italy |
| Model | FE28 |
| Instrument Type | Benchtop |
| Parameter Types | pH and mV (single-channel) |
| pH Measurement Range | -2 to 16 |
| pH Resolution | 0.01 / 0.1 |
| pH Accuracy | ±0.01 |
| mV Measurement Range | 0 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±1 |
| Temperature Range | -5 °C to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Data Storage Capacity | 200 measurements |
| Connectivity | RS232 and USB |
| Electrode Included | LE438 pH electrode |
| ISM Support | Not supported |
| Calibration Solution Compatibility | China-specific calibration buffers |
| Compliance | Designed for GLP-compliant routine lab use |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Model | FE28-Standard |
| Instrument Type | Benchtop (not portable — corrected per technical specification) |
| Parameter Types | pH, mV, Temperature |
| Measurement Range | -2.00 to 16.00 pH |
| Resolution | 0.01/0.1 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±1 mV, ±0.3 °C |
| Temperature Compensation | Automatic and Manual |
| Calibration Points | Up to 5-point |
| Calibration Modes | Linear and Segmented |
| Predefined Buffers | 4 sets (including US, NIST, DIN, and Chinese standards) |
| Data Storage | 200 measurement records + current calibration data |
| Connectivity | BNC, Cinch, NTC 30 kΩ, RS232, USB |
| Display | 4.3-inch segmented LCD |
| Housing Material | ABS |
| Dimensions / Weight | 227 × 147 × 70 mm / 0.63 kg |
| Power Supply | 100–240 V AC, 50–60 Hz / 12 V DC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE30 / FE30K |
| Instrument Type | Benchtop |
| Parameter Types | Conductivity, TDS, Salinity, Resistivity, Temperature |
| Measurement Range | 0.00 µS/cm – 199.9 mS/cm (equivalent to 0.00 mg/L – 199.9 g/L TDS) |
| Resolution | Automatic, 0.01 µS/cm to 0.1 mS/cm (conductivity) |
| Accuracy | ±0.5% of reading |
| Calibration Solutions | Standardized US-type conductivity standards (e.g., 84 µS/cm, 1413 µS/cm, 12.88 mS/cm) |
| Temperature Compensation | Linear, with selectable reference temperature (15–25 °C default) |
| Compliance | Designed per IEC 61010-1 for laboratory electrical safety |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE30 |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Conductivity Range | 0.00 µS/cm to 199.9 mS/cm |
| TDS Range | 0.00 mg/L to 199.9 g/L |
| Conductivity Accuracy | ±0.5% of reading |
| Display | LCD |
| Power Supply | External AC adapter |
| Operating Environment | 5–40 °C, 5–80% RH |
| Compliance | Designed for GLP-compliant workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | FE30K |
| Form Factor | Benchtop |
| Conductivity Range | 0.1 μS/cm to 199.9 mS/cm |
| TDS Range | 0.1 mg/L to 199.9 g/L |
| Resistivity Range | 0.1 Ω·m to 19.99 MΩ·cm |
| Salinity Range | 0.00 to 19.99 psu |
| Temperature Range | 0.0 to 100.0 °C |
| Conductivity Accuracy | ±0.5% of reading |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Linear, adjustable from 0.000 to 10.000 %/°C |
| reference temperatures | 20 °C and 25 °C |
| Calibration | Single-point with three pre-stored standard solutions (84 μS/cm, 1413 μS/cm, 12.88 mS/cm) |
| Display | Backlit LCD showing conductivity/TDS/salinity/resistivity, temperature, stability indicator, calibration status, and compensation settings |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| Parameter Capability | Multi-parameter (pH, mV, °C, Conductivity) |
| pH Range | –2.00 to 16.00 |
| mV Range | –2000 to +2000 mV |
| Temperature Range | 5 to 105 °C |
| pH Resolution | 0.01 / 0.1 |
| mV Resolution | 1 mV |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 |
| mV Accuracy | ±1 mV |
| Temperature Accuracy | ±0.3 °C |
| Calibration Points | Up to 5-point (linear or segmented) |
| Predefined Buffers | 4 sets |
| Data Storage Capacity | 200 measurement records |
| Electrode Interfaces | BNC, Cinch, NTC 30 kΩ |
| Connectivity | RS232, USB |
| ATC Support | Yes (optional probe, P/N 12997876) |
| Display | 4.3-inch segment LCD |
| Housing Material | ABS |
| Dimensions (W × H × D) | 227 × 147 × 70 mm |
| Weight | 0.63 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FG2 |
| Instrument Type | Portable |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 |
| pH Accuracy (relative) | ±0.01 |
| mV Range | −1999 to +1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy (relative) | ±1 |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | Up to 3-point, with 4 predefined buffer sets |
| Data Storage | 30 measurements |
| Display | LCD |
| Power Supply | 4 × AAA 1.5 V batteries |
| IP Rating | IP54 |
| Operating Environment | 0–40 °C, 5–80 % RH |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FG3 |
| Conductivity Range | 0.01 µS/cm to 199.9 mS/cm |
| TDS Range | 0.01 mg/L to 199.9 g/L |
| Salinity Range | 0.00–19.99 psu |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| Conductivity Accuracy | ±0.5 % of reading |
| Calibration | Single-point automatic calibration |
| Display | LCD with simultaneous readout of conductivity/TDS/salinity, temperature, endpoint status, and system symbols |
| Protection Rating | IP54 |
| Power Supply | 4 × AAA 1.5 V batteries |
| Operating Environment | 0–40 °C, 5–80 % RH |
| Data Storage | 30 measurement records |
| Compensation | Linear temperature compensation with selectable reference temperature (e.g., 20 °C or 25 °C) |
| Auto-Endpoint Detection | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FG4 |
| Measurement Principle | Galvanic Cell (Zero-Polarization) |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C |
| DO Range (%) | 0.00–199.9% (extended to 400%) |
| DO Range (mg/L & ppm) | 0.0–45.0 mg/L (ppm) |
| DO Resolution | 0.1% / 0.01 mg/L / 0.01 ppm |
| DO Accuracy | ±1% of reading or ±1 mg/L (whichever is greater) |
| Salt Range | 0.0–50.0 ppt (0.1 ppt resolution) |
| Atmospheric Pressure Range | 375–825 mmHg / 500–1100 mbar / 500–1100 hPa |
| Pressure Resolution | 1 unit |
| Calibration Points | 2-point (0% and 100% O₂) |
| Data Storage | 30 measurements |
| Display | Backlit LCD with simultaneous readout of DO value, temperature, endpoint status, and compensation indicators |
| Enclosure Rating | IP54 |
| Power Supply | 4 × 1.5 V AAA batteries |
| Operating Environment | 0–40 °C, 5–80% RH (non-condensing) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Series | FillPal™, InMotion™, SC1(H), SC30(H) |
| Application Scope | Fully automated sample introduction, rinsing, drying, and (where applicable) heating for density and refractive index measurement |
| Compliance Context | Designed to support GLP/GMP workflows with audit-trail-capable software integration |
| Fluid Handling Architecture | Positive-pressure filling (SC-series), peristaltic pumping (FillPal/InMotion), chemically resistant wetted materials (e.g., PTFE, ETFE, sapphire, Hastelloy C-276 where specified) |
| Temperature Control | Ambient-only (FillPal, InMotion, SC1/SC30) or heated up to 100 °C (SC1H/SC30H) |
| Sample Capacity | 1 (FillPal, SC1, SC1H) or up to 303 positions (InMotion), or 30 vials (SC30, SC30H) |
| Cleaning Protocol | Full-cycle automated rinse-dry sequence with configurable solvent selection and dwell times |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Filter Paper Weighing Solution |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop |
| Parameter Type | Single-Parameter (pH) |
| Measurement Range | −2.00 to 16.00 pH |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Calibration Standards | Chinese JJG 119 / USP |
| Display | Large backlit LCD |
| Connectivity | RS232 and USB ports |
| Electrode Holder | Removable and stowable |
| Dimensions | 227 × 147 × 70 mm |
| Weight | 0.63 kg |
| Compliance | Designed for GLP-compliant workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | FE30, FG3 |
| Conductivity Range | 0.00 µS/cm to 199.9 mS/cm |
| Resolution | 0.01 µS/cm to 0.1 mS/cm (auto-ranging) |
| Accuracy | ±0.5% of reading |
| Temperature Range | 0.0–100.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C |
| TDS Range | 0.0 mg/L to 199.9 g/L |
| Calibration | Single-point with three pre-programmed standards (84 µS/cm, 1413 µS/cm, 12.88 mS/cm) |
| Data Storage | 30 readings (FG3 only) |
| Ingress Protection | IP54 (FG3) |
| Power Supply | AC adapter (FE30) |
| Form Factor | Benchtop (FE30), Portable (FG3) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FE20 / FE30 |
| pH Range | 0.00–14.00 |
| Conductivity Range | 0.00 µS/cm–199.9 mS/cm |
| mV Range | −1999–+1999 mV |
| TDS Range | 0.0 mg/L–199.9 g/L |
| Temperature Range | 0.0–100.0 °C |
| Salinity Range | 0.00–19.99 psu |
| pH Resolution | 0.01 pH |
| Conductivity Resolution | 0.01 µS/cm–0.1 mS/cm (auto-ranging) |
| mV Resolution | 1 mV |
| TDS Resolution | 0.1 mg/L–0.1 g/L (auto-ranging) |
| Temperature Resolution | 0.1 °C |
| pH Accuracy | ±0.01 pH |
| Conductivity Accuracy | ±0.5 % of full scale |
| mV Accuracy | ±1 mV |
| TDS Accuracy | ±0.5 % of full scale |
| Temperature Accuracy | ±0.5 °C (±0.3 °C for built-in sensor) |
| Calibration | Up to 3-point pH with 4 predefined buffer sets |
| Power Supply | 220 V/50 Hz AC adapter or 9 V DC battery |
| Data Storage | 99 measurement records |
| Interface | RS232 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveEasyPlus™ |
| Form Factor | Benchtop |
| Application Environment | Laboratory |
| Conductivity Range | 0.01 µS/cm to 500 mS/cm |
| Salinity Range | 0.00–42 psu |
| Temperature Range | 0–105 °C |
| Minimum Conductivity Resolution | 0.01 µS/cm |
| TDS Range | 0.01 mg/L to 300 g/L |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.3 °C |
| Temperature Compensation | Linear, 0.00–10.00 %/°C, reference temperatures 20 °C and 25 °C |
| Data Storage | 200 measurement records + current calibration data |
| Interface | RS232 and USB |
| Electrode Compatibility | LE703 (included) |
| Compliance | Designed for GLP-compliant workflows with audit-ready calibration logging |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FiveEasyPlus™ Benchtop |
| Conductivity Range | 0.01 µS/cm to 500 mS/cm |
| Resolution (Conductivity) | 0.01 µS/cm (auto-ranging) |
| Accuracy (Conductivity) | ±0.5% of reading |
| Temperature Range | 0–105 °C |
| Temperature Resolution/Accuracy | 0.1 °C / ±0.3 °C |
| Temperature Compensation | Linear, 0.00–10.00 %/°C |
| Reference Temp | 20 °C or 25 °C |
| TDS Range | 0.01 mg/L to 300 g/L |
| Salinity Range | 0.00–42 psu |
| Data Storage | 200 measurement records + current calibration data |
| Interfaces | RS232 and USB |
| Electrode Included | LE703 (for aqueous samples, medium-to-high conductivity) |
| Calibration Standards Supplied | 1413 µS/cm and 12.88 mS/cm pre-filled pouches |