MINSPEC
Filter
Showing all 6 results
| Brand | MINSPEC |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MP-5600 |
| Instrument Type | Linear Ion Trap Mass Spectrometer |
| Chromatography Configuration | Low Thermal Mass (LTM) Gas Chromatograph |
| Mass Range | 15–550 m/z |
| Scan Speed | 10,000 Da/s |
| Mass Accuracy | High (typical ≤ 0.2 Da RMS error under calibration) |
| Oven Ramp Rate | Up to 30 °C/s |
| Detection Limit | Sub-ppt (v/v) for target VOCs in air matrix |
| Dimensions | 420 × 320 × 210 mm |
| Weight | <12.5 kg |
| Sample Introduction | Direct gas, headspace, liquid injection, and thermal desorption (solid-phase microextraction compatible) |
| Brand | MINSPEC |
|---|---|
| Model | MP-5600 |
| Origin | Shandong, China |
| Instrument Type | Portable GC-MS |
| Mass Range | AMU (atomic mass units) |
| Dynamic Range | 7 decades |
| Mass Resolution | <1.0 amu at FWHM |
| Scan Modes | Full Scan, Selected Ion Monitoring (SIM), Tandem MS (MS/MS) |
| Sensitivity | 10× higher than conventional portable GC-MS systems |
| Weight | Not specified |
| Brand | MINSPEC |
|---|---|
| Model | MP-5600Plus |
| Mass Range | 15–550 Da |
| Scan Speed | 10,000 Da/s |
| Mass Analyzer Type | Linear Ion Trap |
| Detection Principle | Electron Ionization (EI) with Inert High-Temperature Ion Source |
| Sample Introduction | Triple-mode (Gas, Liquid, Solid) |
| Compliance | GB/T 11606–2007, GB/T 32210–2015, GJB 150.16A–2009, HJ 1223–2021, HJ 1227–2021 |
| Brand | MINSPEC |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MP-5600Plus |
| Instrument Type | Portable GC-MS |
| Mass Range | 15–550 Da |
| Dynamic Range | 7 decades |
| Mass Resolution | Unit Mass Resolution |
| Maximum Scan Rate | 10,000 scans/s |
| Sensitivity | sub-ppt (gas-phase VOCs) |
| Weight | <18 kg |
| Brand | MINSPEC |
|---|---|
| Model | MP-5600Plus |
| Origin | Shandong, China |
| Detection Targets | ODS (CFCs, HCFCs, Halons, Methyl Bromide), VOCs, SVOCs |
| Sample Matrices | Ambient Air, Water (via Headspace), Soil (via Purge-and-Trap or Thermal Desorption), Refrigerant Gases |
| Compliance | GB/T 32210–2015, HJ 11223–2021, HJ 1227–2021, HJ 1058–2019 |
| Detection Principle | Capillary GC separation coupled with linear ion trap MS detection |
| Ionization Mode | Electron Ionization (EI), inertized high-temperature source (up to 300 °C) |
| Preconcentration | Integrated cryogenic trapping (down to 0 °C) |
| Mass Analyzer | Dual-curved linear ion trap |
| Dynamic Range | 7 orders of magnitude |
| Internal Standard Delivery | Automated, inertized, programmable syringe-based introduction |
| Brand | MINSPEC |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MP-5600Plus |
| Instrument Type | Portable GC-MS |
| Mass Range | Not Specified (AMU) |
| Dynamic Range | 7 decades |
| Mass Resolution | <1.0 amu at FWHM |
| Scan Modes | Full Scan, Selected Ion Monitoring (SIM), Tandem MS (MS/MS) |
| Sensitivity | ~10× higher than conventional portable GC-MS for ODS compounds |
| Weight | Not Specified (kg) |