Nanobase
Filter
Showing all 6 results
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Instrument Type | Confocal Raman Microspectroscopy Platform with Integrated Photoconductive Mapping Capability |
| Laser Compatibility | 400–730 nm (VIS) and 780–1000 nm (NIR) |
| Spatial Resolution | 1 µm (X/Y/Z) |
| Scan Area | 200 × 200 µm |
| Objective Options | 5×, 40× Long Working Distance |
| Compatible SMUs | Keithley 2400 & 2600 Series |
| Software | NanoPhotocurrent v3.x (GLP-compliant data logging, CSV export, multi-region mapping) |
| Compliance | ASTM E2971 (Raman Microspectroscopy), ISO/IEC 17025 traceable calibration support, FDA 21 CFR Part 11 ready (audit trail & electronic signature optional) |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Type | Confocal Micro-Raman Spectrometer with Integrated Maskless Spatial Light Modulation |
| Excitation Architecture | DMD + SLM Dual-Modulated Wideband Illumination Platform |
| Optical Configuration | Upright Research-Grade Microscope Coupled to Broadband Source & Tunable Monochromatic Selection (VIS–NIR–MIR) |
| Software Integration | NanoSpectrum Suite with Keithley 2400/2600 Series SMU Compatibility |
| Compliance | GLP/GMP-ready data logging, ASTM E2587-compliant measurement traceability, ISO/IEC 17025-aligned calibration framework |
| Environmental Operation | Compatible with cryogenic stages (4 K–300 K), in-plane/out-of-plane magnetic fields (up to 9 T), and controlled-atmosphere chambers |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelengths (Standard) | 532 nm, 633 nm, 785 nm |
| Laser Linewidth | ≤1 MHz |
| SMSR | ≥30 dB |
| Wavelength Stability | ≥1 pm |
| Power Stability (8 h) | ±1% |
| Spectrometer Focal Length | 833 mm |
| Grating Options | 1800 lp/mm @ 400 nm, 1200 lp/mm @ 650 nm, 300 lp/mm @ 500 nm |
| Spectral Resolution (Reference) | 0.033 nm / 29.25 cm⁻¹ (with 1800 lp/mm grating, 25 µm pixel) |
| Minimum Detectable Raman Shift | 125 cm⁻¹ |
| Optical Filter Options | Edge filter (<100–3750 cm⁻¹), Optional ultra-low-frequency filter (<250 cm⁻¹) with bandpass + OD3 dual-stage rejection |
| Detector | Back-illuminated deep-depletion CCD, 2000 × 256 pixels, 15 µm × 15 µm pixel size |
| Scanning Method | Galvo-based laser scanning (non-contact, sample-static mapping) |
| Mapping Precision | ≤20 nm lateral positioning accuracy |
| Objective Options | 10×, 20×, 40× (default), 50×, 100×, Long WD 20×/40× |
| Software | NanoSpectrum Suite (supports .txt, .csv, .spm export), NanoControl mobile app for remote monitoring |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Model | PL_Mapping_System |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Photocurrent Mapping Capability |
| Spectral Range | 30–6000 cm⁻¹ |
| Spectral Resolution | < 0.02 µm (equivalent to < 0.5 cm⁻¹ at 532 nm) |
| Spatial Resolution | < 0.02 µm (diffraction-limited, dependent on objective NA and excitation wavelength) |
| Spectral Reproducibility | < 0.1 µm (wavelength stability over time and position) |
| Excitation Wavelengths | 445, 532, 635, 808, 1530 nm |
| Field of View | 200 µm × 200 µm (with 40×, NA = 0.75 objective) |
| XY Stage Travel | 150 mm × 150 mm (5 µm resolution) |
| Z-Travel | ±10 mm (1 µm resolution) |
| Probe Station | 6-inch vacuum chuck, gold/tungsten probes, PH-C15 high-precision manipulators, leakage current < 10 fA |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Model | CONFOCAL_RAMAN_IMAGING_SYSTEM |
| Excitation Laser | 532 nm (up to 100 mW DPSS), optional 660 nm / 785 nm |
| Objective | 40×, NA = 0.75 |
| Scan Area | ≥200 µm × 200 µm |
| Spectral Resolution (FWHM) | ~0.12 nm |
| Dispersion | ~0.038 nm/pixel |
| Grating | 1800 lp/mm VPHG (transmission-type volume phase holographic grating) |
| Polarization Control | Excitation (0–180° continuous rotation), Collection (extinction ratio >200:1, transmission >83%) |
| Notch Filter | OD >6 (blocking >99.9999%), bandwidth <0.5 nm FWHM |
| Bandpass Filter | OD7, bandwidth <0.3 nm, diffraction efficiency >90% |
| Detector Compatibility | Andor, Princeton Instruments CCD/CMOS cameras |
| Software Platform | LabVIEW-based control with real-time spectral acquisition and mapping engine |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Nanobase |
|---|---|
| Origin | South Korea |
| Instrument Type | Confocal Micro-Raman Spectrometer |
| Spectral Range | 50–5900 cm⁻¹ |
| Spectral Resolution | 2.5 cm⁻¹ |
| Spatial Resolution | < 0.02 µm |
| Minimum Wavenumber | < 250 cm⁻¹ |
| Spectral Reproducibility | < 0.1 µm |